Search results for: ODD RANDOM PHASE ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY
-
In-situ odd random phase electrochemical impedance spectroscopy study on the electropolymerization of pyrrole on iron in the presence of sodium salicylate – The influence of the monomer concentration
PublicationIn this work, the potentiostatic electropolymerization of polypyrrole (PPy) on iron in aqueous solution of sodium salicylate and pyrrole is studied in situ by odd random phase electrochemical impedance spectroscopy (ORP-EIS). The influence of the pyrrole concentration on the electrosynthesis process is investigated. The ORP-EIS technique ensures a reliable analysis of the PPy electrosynthesis on iron by means of an advanced data...
-
Kazimierz Darowicki prof. dr hab. inż.
PeopleStudia wyższe ukończyłem w czerwcu 1981 roku po zdaniu egzaminu dyplomowego i obronie pracy magisterskiej. Opiekunem pracy magisterskiej był dr hab. inż. Tadeusz Szauer. W roku 1991, 27 listopada uzyskałem stopień naukowy broniąc pracę doktorską zatytułowaną „Symulacyjna i korelacyjna analiza widm immitancyjnych inhibitowanej reakcji elektrodowej”. Promotorem pracy był prof. dr hab. inż. Józef Kubicki (Wydział Chemiczny...
-
Tailoring the electrochemical degradation of iron protected with polypyrrole films for biodegradable cardiovascular stents
PublicationThe degradation of polypyrrole (PPy) coated iron is studied in phosphate buffer saline solution at 37 °C by odd random phase multisine electrochemical impedance spectroscopy (ORP-EIS). PPy is electropolymerized with anti-inflammatory salicylates incorporated in the film, as a drug release system. The modelling of EIS over time provides the quantitative description of the corrosion behaviour of the material. Thus, the reliable...
-
Conducting polymers for biodegradable metallic implants
PublicationNowadays permanent metallic cardiovascular stents are long-term implants. The long-time presence of such an implant in human body can cause overgrowth of tissue within the treated portion of the vessel, blockage of the circulatory system and many other clinical complications, such as thrombosis, prolonged physical irritations or chronic inflammation. Therefore, in recent years, there is an interest to create biodegradable metallic...
-
Controlling crystallites orientation and facet exposure for enhanced electrochemical properties of polycrystalline MoO3 films
PublicationThis study focuses on the development and optimization of MoO3 films on commercially available FTO substrates using the pulsed laser deposition (PLD) technique. By carefully selecting deposition conditions and implementing post-treatment procedures, precise control over crystallite orientation relative to the substrate is achieved. Deposition at 450 °C in O2 atmosphere results in random crystallite arrangement, while introducing...
-
Electrochemical Evaluation of Sustainable Corrosion Inhibitors via Dynamic Electrochemical Impedance Spectroscopy
PublicationFinding suitable measurement methods for the effective management of electrochemical problems is of paramount importance, particularly for improving efficiency in corrosion protection. The need for accurate measurement techniques specific to nonstationary conditions has long been recognized, and promising approaches have emerged. This chapter introduces dynamic electrochemical impedance spectroscopy as a novel advancement in electrochemistry...
-
Local electrochemical impedance spectroscopy in dynamic mode of galvanic coupling
PublicationA novel method that combines local electrochemical impedance spectroscopy and mapping in dynamicmode is proposed. Method was validated over two galvanic couplings, namely zinc/copper and cad-mium/copper. Impedance spectrum response for all measuring points was obtained by means ofsimultaneous implementation of selected range of frequencies. Proposed method allows the measure-ment in a more time-efficient manner, at the same time...
-
Evaluation of Temperature Influence on Electrochemical Processes Occurring in a Lithium-Ion Supercapacitor with the Use of Dynamic Electrochemical Impedance Spectroscopy
PublicationIn order to obtain the full impedance characteristics of a lithium-ion capacitor as a function of temperature, the authors proposed the use of dynamic electrochemical impedance spectroscopy. Impedance tests were carried out under wide range of dynamic temperature changes for lithium-ion supercapacitors. Significant differences in electrochemical processes were observed as a result of working temperature. Moreover, the quality of...
-
Sensing the onset of epoxy coating degradation with combined Raman spectroscopy/atomic force microscopy/electrochemical impedance spectroscopy
PublicationThe paper presents the results of investigation on epoxy resin durability upon 12-week exposure to UV radiation. The aim was early determination of the onset of epoxy degradation and for this purpose an epoxy film on steel substrate systems were periodically inspected using Raman spectroscopy, atomic force microscopy and electrochemical impedance spectroscopy. The behaviour of examined polymer could be divided into three periods: immunity,...
-
Validity of impedance spectra obtained by dynamic electrochemical impedance spectroscopy verified by Kramers-Kronig transformation.
PublicationArtykuł przedstawia weryfikację wiarygodności widm impedancyjnych otrzymanych za pomocą niedawno wprowadzonej techniki eksperymentalnej - Dynamicznej Elektrochemicznej Spektroskopii Impedancyjnej (Dynamic Electrochemical Impedance Spectroscopy, DEIS). Technika ta zakłada, że badany system jest pseudostacjonarny jeśli czas pomiaru jest odpowiednio krótki. Czas potrzebny na otrzymanie pojedynczego spektrum zależy od długości okna...
-
Biosilica from sea water diatoms algae—electrochemical impedance spectroscopy study
PublicationHere, we report on an electrochemical impedance study of silica of organic origin as an active electrode material. The electrode material obtained from carbonized marine biomass containing nanoporous diatoms has been characterised by means of XRD, IR, SEM and EIS. Dif- ferent kinds of crystallographic phases of silica as a result of thermal treatment have been found. The electrode is electrochemically stable during subsequent cyclic...
-
Investigation of the electrochemical behaviour of AA1050 aluminium alloy in aqueous alkaline solutions using Dynamic Electrochemical Impedance Spectroscopy
PublicationThe paper presents the electrochemical behaviour of aluminium alloy AA1050 in aqueous alkaline media in the pH range 14–8.5. Electrochemical study was applied in order to obtain comprehensive information on the mechanism and kinetics of the process of anodic dissolution of aluminium, supplemented by monitoring of surface topography using an electron microscope. The corrosion rate of AA1050 increases with increasing concentration...
-
Study of Direct Methanol Fuel Cell Process Dynamics Using Dynamic Electrochemical Impedance Spectroscopy
PublicationA new technique, which was developed to characterize the direct methanol fuel cell under work conditions, has been presented in this paper. The impedance measurements were made using dynamic electrochemical impedance spectroscopy research technique in the galvanostatic mode, using multiple sinusoidal excitation. Obtained results show, that together with an increase of the temperature and working load, the global impedance...
-
New Method of Non-Linear Electrochemical Impedance Spectroscopy with an Amplitude-Modulated Perturbation Signal
PublicationThe paper presents a new method of non-linear electrochemical impedance spectroscopy (NLEIS), which allows fast and nondestructive evaluation of the corrosion rate and determination of the Tafel coefficients values for a corrosion system under investigation. This method employs amplitude modulation of the ac perturbation signal. The study demonstrated that it was possible to obtain impedance characteristic as a function of the...
-
Three modes of electrochemical impedance spectroscopy measurements performed on vanadium redox flow battery
PublicationThis article presents an innovative approach to monitor working redox flow batteries using dynamic electrochemical impedance spectroscopy, diverging from the commonly sequential impedance methods carried out under potentiostatic or galvanostatic conditions close to the open circle voltage. The authors introduce a fresh variation of dynamic impedance measurement that leverages an amplitude-modulated multi-frequency alternating current...
-
A Comprehensive Analysis of Impedance of the Electrochemical Cell
PublicationA comprehensive impedance characteristics of two electrodes electrochemical cell has been pre sented. In this method a multisinusoidal current excitation signal is used. The change of potential of both the electrodes are all registered as a function of time. The proposed method gives the possibility of determining the impedance of both electrodes individually as well as the impedance of a twoelectrode system. Additional application...
-
Dynamic Electrochemical Impedance Spectroscopy (DEIS) as a Tool for Analyzing Surface Oxidation Processes on Boron-Doped Diamond Electrodes
PublicationSurface oxidation processes play a key role in understanding electrochemical properties of boron-doped diamond (BDD) electrodes. The type of surface termination groups, which create the potential window of electrolytic water stability or hydrophobicity, influences such properties. In this study the kinetics of oxidation process under anodic polarization were studied in situ by means of Dynamic Electrochemical Impedance Spectroscopy...
-
Instantaneous electrochemical impedance spectroscopy of electrode reactions
Publication -
Instantaneous electrochemical impedance spectroscopy of electrode reactions.
PublicationUstalona została ciągła transformata STFT sinusoidalnego sygnału pobudzeniai odpowiedzi prądowej dla pierwszorzędowej reakcji elektrodowej. Impedancja elektrodowa wyznaczona została w łącznej dziedzinie czasowo-częstotliwościowej. Wykonano pomiary reakcji redukcji Cd(II) na kapiącej elektrodzie rtęciowej w funkcji czasu. Zaprezentowano możliwość wyznaczania chwilowych widm impedancyjnych. Opisano czasowe charakterystyki rezystancji...
-
A Probe into the Corrosion Behavior of a WE43B Magnesium Alloy in a Simulated Body Fluid using Dynamic Electrochemical Impedance Spectroscopy
PublicationWE43B is one of the newest Mg alloys with practical application in biomedical implant technology. This work attempts to scrutinize the corrosion characteristics of WE43B alloy in a simulated body fluid (SBF) at a typical body temperature. The dynamic-electrochemical impedance spectroscopy with the capacity to track changes on surfaces in a dynamic corrosive system is used in combination with other classical techniques namely, linear...
-
Electrical and mechanical characterization of two-phase alloys by means of scanning probe microscopy in dynamic impedance spectroscopy mode
PublicationDynamic impedance spectroscopy, evaluated for measuring non-stationary systems, was used in combination with scanning probe microscope. Using this approach, localized impedance measurements in the AFM contact mode could be carried out. Additionally, impedance–force curves were made at each phase of investigated materials to illustrate the relation between impedance and the force applied to a probe. Therefore, correlation of electrical...
-
Application of the dynamic electrochemical impedance spectroscopy to investigation of spontaneous electrochemical oscillations
PublicationPrzedstawione zostały wyniki impedancyjne uzyskane podczas oscylacji prądowych miedzi w kwaśnym środowisku zawierającym jony chlorkowe. Kształt chwilowych widm impedancyjnych jest skorelowany z uzyskanym przebiegiem prądowym. Badany proces anodowego roztwarzania miedzi kontrolowany jest na przemian aktywacyjnie i dyfuzyjnie.
-
Validation of dynamic electrochemical impedance spectrograms using autocorrelation function
PublicationValidation of impedance data is essential for checking the reliability of experimental data. Kramers – Kronig transformation is used to verify data obtained from classical Electrochemical Impedance Spectroscopy (EIS) measurements. Data obtained from Dynamic Electrochemical Impedance Spectroscopy (DEIS) could be validated in the same way, but in this case, there is no information about internal consistency between every single spectrum...
-
Characterization of Bi6Fe2Ti3O18 Ceramics with Impedance Spectroscopy
PublicationIn the present research the tool of impedance spectroscopy was utilized to characterize dielectric behavior of Aurivillius-type ceramics of Bi6Fe2Ti3O18 composition fabricated by hot pressing method from the stoichiometric mixture of oxides Bi2O3, TiO2 and Fe2O3. Impedance spectroscopy was applied to characterize dielectric response of bulk, grain boundary, and material/electrode interfaces of the fabricated polycrystalline ceramic...
-
Detection of the Plant Pathogen Pseudomonas Syringae pv. Lachrymans on Antibody-Modified Gold Electrodes by Electrochemical Impedance Spectroscopy
PublicationThe present work describes an impedimetric immunosensor for Pseudomonas syringae pv. lachrymans (Psl) detection. This pathogen infects many crop species causing considerable yield losses, thus fast and cheap detection method is in high demand. In the assay, the gold disc electrode was modified with 4-aminothiophenol (4-ATP), glutaraldehyde (GA), and anti-Psl antibodies, and free-sites were blocked with bovine serum albumin (BSA)....
-
The electrochemical impedance spectroscopy studies of the anode material based on polymer and starch derived ceramic for lithium ion batteries
PublicationThe anode materials derived of preceramic polymer poly(1,2-dimethylsilazane) (PSN) and starch was study. Commercially available polysilazane (poly(1,2-dimethylsilazane (PSN 2M01 Gelest) was mixed with commercially available starch (POCH Gliwice). The ratio polymer/starch (PSN/starch) was 1/1 or 3/7. The polysialazane/starch blend was cross-linked at 230 ºC for 2 h followed by heating to the final temperature (500 ºC, 700 ºC and...
-
Application of Impedance Spectroscopy for Bi1−xNdxFeO3 Ceramics Characterization
PublicationIn the present paper the synthesis conditions for fabrication of Bi1−xNdxFeO3 ceramics are reported. The single phase polycrystalline samples of Bi1−xNdxFeO3 were prepared by standard solid state reaction method from the mixture of oxides viz.: Bi2O3, Fe2O3 and Nd2O3. The samples were characterized by impedance spectroscopy in the frequency range 10Hz – 1MHz at room temperature.
-
Corrosion rate measurements by non-linear electrochemical impedance spectroscopy
Publication -
Evaluation of pitting corrosion by means of dynamic electrochemical impedance spectroscopy
Publication -
Evaluation of pitting corrosion by means of dynamic electrochemical impedance spectroscopy.
PublicationPrzeprowadzono badania stali stopowej 304L metodą dynamicznej elektrochemicznej spektroskopii impedancyjnej w warunkach liniowo zmieniającego się potencjału. Określono ogólny schemat układu elektrycznego dla elektrody ulegającej korozji. Przeprowadzone badania pozwalają na jednoczesne badanie zachowania się stali stopowej w stanie pasywnym, podczas stanu przejściowego (metastabilne tworzenie się i repasywacja wżerów) oraz w stanie...
-
Dynamic electrochemical impedance spectroscopy of the first order electrode reaction
PublicationCiągłe transformaty STFT sinusoidalnego sygnału pobudzenia i odpowiedzi prądowej zostały wyznaczone dla reakcji elektrodowej pierwszego rzędu. Wyznaczono impedancję elektrody w łącznej dziedzinie czasu i częstotliwości. Wykonano pomiary dla reakcji redukcji Cd(II) na rtęciowej elektrodzie kroplowej w funkcji potencjału. Przedstawiono możliwość wyznaczenia chwilowych widm impedancyjnych. Opisano zależność rezystancji przeniesienia...
-
Selection of excitation signals for high-impedance spectroscopy
PublicationA method of fast impedance spectroscopy of technical objects with high impedance (|Zx| > 1 GOhm) is evaluated in this paper. An object is excited with a signal generated by a digital-to-analog converter (DAC) located on the U2531A DAQ module. Response signals proportional to current flowing through and voltage across the measured object are sampled by analog-to-digital converters (ADC) in the DAQ module. The object impedance spectrum...
-
Novel application of dynamic electrochemical impedance monitoring to a cataphoretic coating process
PublicationThe paper presents a novel method of on-line impedance monitoring of cataphoretic coating application process. Utilization of dynamic electrochemical impedance spectroscopy (DEIS) overcame the fundamental problem connected with non-stationarity of the aforementioned coating deposition process, which eliminates classical impedance spectroscopy technique from a real-time description of cataphoresis. The paper illustrates selected examples...
-
Electrochemical Impedance Spectroscopy data of PDA-modified TiO2 nanotubes
Open Research DataThis dataset contains Electrochemical Impedance Spectroscopy data of the samples from TiO2 nanotubes modified with polydopamine. The studies were presented as a part of the research on "Band Gap Engineering toward Semimetallic Character of Quinone-Rich Polydopamine" (DOI: 10.1021/acs.jpcc.2c08804).
-
Application of quartz crystal microbalance and dynamic impedance spectroscopy to the study of copper corrosion inhibitors
PublicationThe study investigates the application of Dynamic Electrochemical Impedance Spectroscopy (DEIS) and Electrochemical Quartz Crystal Microbalance (EQCM) techniques to examine the corrosion inhibition of copper by Benzotriazole and Sodium Folate in a 0.1 M NaCl solution. DEIS, an advanced version of Electrochemical Impedance Spectroscopy (EIS), allows for real-time monitoring of non-stationary electrochemical systems,...
-
Investigations of the passive layer cracking by means of Dynamic Electrochemical Impedance Spectroscopy
Publication -
Detection of stress corrosion cracking dynamics by dynamic electrochemical impedance spectroscopy
Publication -
Investigations of the passive layer cracking by means of dynamic electrochemical impedance spectroscopy.
PublicationDynamiczna elektrochemiczna spektroskopia impedancyjna została wykorzystana do badania pękania warstwy pasywnej na austenitycznej stali wysokostopowej.Zbadano efekt narzuconego potencjału oraz naprężeń rozciągających na pękanie korozyjne stali wysokostopowej 304L w środowisku 0.5M NaCl w temperaturze pokojowej. Praca przedstawia chwilowe widma impedancyjne uzyskane dla badanego układu przy różnych wartościach potencjałów. Uzyskane...
-
Detection of stress corrosion cracking dynamics by dynamic electrochemical impedance spectroscopy.
PublicationKlasyczne badania korozji naprężeniowej nie dają precyzyjnych informacji o dynamice takiego procesu korozyjnego. Nowa technika dynamicznej elektrochemicznej spektroskopii impedanyjnej, która została opracowana w Katedrze Elektrochemii, Korozji i Inżynierii Materiałowej stwarza takie możliwości. Fakt ten związany z zastosowaną metodologią analizy umożliwiającą selektywną analizą czasowo-częstotliwościową danych pomiarowych.Praca...
-
The application of dynamic electrochemical impedance spectroscopy for stress corrosion cracking studies
PublicationElektrochemiczna Spektroskopia Impedancyjna (ESI) od wielu lat stanowi jedno z najważniejszych narzędzi wykorzystywanych do badania różnych procesów elektrochemicznych. Możliwość przeprowadzania badań w łącznej dziedzinie czasowo-częstotliwościowej ułatwia analizę pomiarów impedancyjnych w czasie. ESI pozwala również na analizę mechanizmu procesów elektrochemicznych w dziedzinie czasu z uwzględnieniem bardzo szybkich zjawisk, takich...
-
Diagnosis of reference electrodes in cathodic protection systems by electrochemical impedance spectroscopy
PublicationPrzedstawiono wyniki badań laboratoryjnych i terenowych przeprowadzonych techniką elektrochemicznej spektroskopii impedancyjnej (EIS). Zaprezentowano widma impedancyjne następujących układów: elektroda odniesienia/elektroda pomocnicza; rurociąg/zakopane i przenośne elektrody odniesienia. Pokazano, że omawiana technika umożliwia badanie stanu technicznego elektrod odniesienia, co zwiększa pewność wyników pomiarów potencjału chronionej...
-
Application of dynamic impedance spectroscopy to scanning probe microscopy.
PublicationDynamic impedance spectroscopy, designed for measuring nonstationary systems, was used in combination with scanning probe microscopy. Using this approach, impedance mapping could be carried-out simultaneously with topography scanning. Therefore, correlation of electrical properties with particular phases of an examined sample was possible. The sample used in this study was spheroidal graphite cast iron with clearly defined phases...
-
Time evolution of Electrochemical Impedance spectra of cathodically protected steel in artificial seawater
PublicationUsability of Electrochemical Impedance Spectroscopy data for better cathodic protection control was investigated. Carbon steel – S235JR2 grade specimen were exposed in artificial seawater environment. Samples were polarized and their potentials corresponded to four different cathodic protection degrees. Time evolution of Electrochemical Impedance spectra was investigated. Goodness of fit function (X2) was analysed in terms of proper...
-
Fast High-Impedance Spectroscopy Method Using SINC Signal Excitation
PublicationIn this paper the method of fast impedance spectroscopy of technical objects with high impedance (|Zx| > 1 Gohm) is evaluated by means of simulation and practical experiment. The method is based on excitation of an object with a sinc signal and sampling response signals proportional to current flowing through and voltage across the measured impedance. The object impedance spectrum is obtained with use of continuous Fourier transform...
-
Novel fast non-linear electrochemical impedance method for corrosion investigations
PublicationThe paper presents a novel approach to corrosion rate monitoring using non-linear electrochemical impedance spectroscopy. The authors propose a new variant of non-linear impedance measurement using amplitude-modulated multi-frequency ac perturbation signal. It allows shortening of measurement duration so it is possible to monitor corrosion rate of the systems experiencing rapid changes. In this way a limitation resulting from lack...
-
The electrochemical impedance spectroscopy studies of cataphoretic-grown epoxy-based coatings
Open Research DataThe dataset contains electrochemical impedance spectroscopy spectra collected for epoxy-based cataphoretic coatings in order to determine the offered anti-corrosion protection. Particular spectra pertain to the coatings applied for the different magnitude of polarization potential imposed, namely 10V, 20V and 30V. The results were obtained within the...
-
Evaluation of the fast impedance spectroscopy method in the laboratory measurement system
PublicationIn this paper the method for fast impedancespectroscopy of technical objects with very high impedance(|Zx| ≥ 1 GΩ) is evaluated by means of simulation and practicalexperiment. The method is based on excitation of an object, witha square pulse and measurements of voltage and currentresponses with DAQ card. The object impedance spectrum isobtained with use of continuous Fourier transform. Someimprovements of the method concerned...
-
Biomolecular influenza virus detection based on the electrochemical impedance spectroscopy using the nanocrystalline boron-doped diamond electrodes with covalently bound antibodies
PublicationNew rapid pathogen detection methods with improved cost-effectiveness and efficiency are currently in the focus of the scientists from all over the world. Based on the experiences from the rapid spread of the influenza virus pandemic in 2009 it is clear that the development of the system for early diagnosis of this infection is essential. The crucial stage of the treatment is the detection of the viral infection during its initial...
-
Comparison of corrosion resistance of al-alloys by means of dynamic electrochemical impedance spectroscopy
PublicationPrzeprowadzono badania metodą dynamicznej elektrochemicznej spektroskopii impedancyjne stopów 1100 i 5162. Zaproponowano zastępcze modele elektryczne opisujące zachowanie się stopów w warunkach ekspozycji w roztworach zawierających wysokie stężenie jonów chlorkowych. Wyznaczono zmiany podstawowych parametrów elektrycznych układów zastępczych od potencjału. Stwierdzono wyższą podatność na korozję stopu 5162 w porównaniu ze stopem...
-
Application of Electrochemical Impedance Spectroscopy to evaluate cathodically protected coated steel in seawater
PublicationTwo types of organic coated carbon steel (S235JR2 grade) electrodes were exposed to artificial seawater environment. One prepared type was defect free while the other one had an intentionally introduced φ0,5 cm coating defect. Both kinds of samples were polarized during the exposure to four potentials corresponding to four different cathodic protection levels. Evolution of their EIS spectra is presented in this paper. Results obtained...