Search results for: LOCALIZATION MODEL
-
Stability of trusses with linear elastic side-supports
PublicationThe present research is devoted to study of a lateral buckling of truss with linear elastic side supports. The elastic support reaction in relation to force in compressed chord and coefficient of buckling length related to side support distance are also calculated. The effect of slope of side support on limit force is also considered. The nonlinear analysis of two roof trusses are carried out. The results are compared to design...
-
Robust unsupervised georeferencing algorithm for aerial and satellite imagery
PublicationIn order to eliminate a human factor and fully automate the process of embedding the spatial localization information in a remote sensed image the integrated georeferencing method was proposed. The paper presents this unsupervised and robust approach which is comprised of pattern recognition, using SIFT-based detector, and RANSAC based outlier removal with matching algorithm.
-
Intracranial electrophysiological recordings from the human brain during memory tasks with pupillometry
PublicationData comprise intracranial EEG (iEEG) brain activity represented by stereo EEG (sEEG) signals, recorded from over 100 electrode channels implanted in any one patient across various brain regions. The iEEG signals were recorded in epilepsy patients (N=10) undergoing invasive monitoring and localization of seizures when they were performing a battery of four memory tasks lasting approx. 1 hour in total. Gaze tracking on the task...
-
New Method for Increasing Precision of Position Estimation in Hybrid Inertial Navigation System
PublicationIn article new method for increasing precision of position estimation by using inertial navigation in hybrid localization system with reduced number of reference nodes for radio distance measurements was presented. Measuring campaign using developed measuring stand were carried out to verify precision of position estimation of moving person in indoor environment.
-
The Methodology of identifying the place to install shunt compensators in the transmission network
PublicationThis methodology of selection and localization of static com- paper presents pensators in wide network. Proposed method is based on analysis of voltage area power profiles in the nodes of the power grid, and designating locations, In Which Voltages ex- cessively tend to change in time. Practical way of modeling the SVC device in PLANS program you Presented, as well as some example results of research.
-
Supramolecular junctions of the PDA tetramers
Open Research DataIn this dataset, a set of polydopamine (PDA) supramolecular junctions with linear and cyclic tetramers in different oxidation states (indolequinone , IQ or dihydroxyindole, DHI) in the scattering region are investigated. Electronic structure of the supramolecular junction with cyclic and linear PDA tetramers, including Electron density maps for the...
-
Optimal configuration of an electrode array for measuring ventricles' contraction
PublicationAn influence of an electrode-array configuration on an impedance signal composition for a fixed spatial distribution of its sources is examined in the paper. The Finite Element Method and Geselowitz relationship were used for examining three different electrode-arrays. A sensitivity approach was used to evaluate each configuration assuming that localization of the signal source is known. A conductivity change, thus the source of...
-
Position Estimation in Mixed Indoor-Outdoor Environment Using Signals of Opportunity and Deep Learning Approach
PublicationTo improve the user's localization estimation in indoor and outdoor environment a novel radiolocalization system using deep learning dedicated to work both in indoor and outdoor environment is proposed. It is based on the radio signatures using radio signals of opportunity from LTE an WiFi networks. The measurements of channel state estimators from LTE network and from WiFi network are taken by using the developed application....
-
A method of self-testing of analog circuits based on fully differential op-amps with theTCBF classifier
PublicationA new approach of self-testing of analog circuits based on fully differential op-amps of mixed-signal systems controlled by microcontrollers is presented. It consists of a measurement procedure and a fault diagnosis procedure. We measure voltage samples of a time response of a tested circuit on a stimulation of a unit step function given at the common-mode reference voltage input of the op-amp. The fault detection and fault localization...
-
Interictal high-frequency oscillations in focal human epilepsy
PublicationPURPOSE OF REVIEW: Localization of focal epileptic brain is critical for successful epilepsy surgery and focal brain stimulation. Despite significant progress, roughly half of all patients undergoing focal surgical resection, and most patients receiving focal electrical stimulation, are not seizure free. There is intense interest in high-frequency oscillations (HFOs) recorded with intracranial electroencephalography as potential...
-
Investigation of abdomen surface deformation due to life excitation: implications for implant selection and orientation in laparoscopic ventral hernia repair
PublicationVentral hernia is a common medical problem. Statistically there are around 10% recurrences of the sickness. The authors' former investigation proved edges of the hernia orifice displacements to be one of the factors causing recurrence. Thus, experimental investigation of the abdomen surface deformation due to some normal activities of people is studied.The extreme strains, their localization and directions are identified. The acquired...
-
A solution of the integrated µBIST for functional and diagnostic testing in mixed-signal electronic embedded systems
PublicationMain problem of the paper is testing of analog circuits and blocks in mixed-signal electronic embedded systems (EESs), using the built-in self-test (BIST) technique. The integrated mBIST based on reusing signal blocks already present in an EES, such as processors, memories, ADCs, is presented. The novelty of the solution is the extended functionality of the mBIST. It can perform 2 testing functions: functional testing and fault...
-
A telemedical and an outpatient thoracic impedance measurements - a validation algorithm of the electrodes placement
PublicationThis paper presents the algorithm for validation of electrodes locations for the thoracic impedance measurements. In particular the presented algorithm was designed to perform the telemetric sleep apnea monitoring. One of the problems, during the clinical tests of a developed device, was to preserve the repeatability of measurements. It strongly depended on the appropriate electrodes placement on the examined person’s thorax. It...
-
A testing method of analog parts of mixed-signal electronic systems equipped with the IEEE1149.1 test bus
PublicationA new solution of the JTAG BIST for testing analog circuits in mixed-signal electronic microsystems controlled by microcontrollers and equipped with the IEEE1149.1 bus is presented. It is based on a new fault diagnosis method in which an analog circuit is stimulated by a buffered signal from the TMS line, and the time response of the circuit to this signal is sampled by the ADC equipped with the JTAG. The method can be used for...
-
Cartographic Representation of Route Reconstruction Results in Video Surveillance System
PublicationThe video streams available in a surveillance system distributed on the wide area may be accompanied by metadata are obtained as a result of video processing. Many algorithms applied to surveillance systems, e.g. event detection or object tracking, are strictly connected with localization of the object and reconstruction of its route. Drawing related information on a plan of a building or on a map of the city can facilitate the...
-
Analysis of magnetic field of Helmholtz's coils
PublicationThe 3-axis fluxgate magnetometer requires conducting a precise calibration in the magnetic field whose value is determined and which is characterized by the high uniformity of the distribution of the field, especially along the axis of the sensors. The generation of the magnetostatic field characterized by the high uniformity, can be achieved by using the Helmholtz's coils. The requirements of the uniformity of distribution of...
-
RF Indoor Positioning System Supported by Wireless Computer Vision Sensors
PublicationIn this paper the possibility of increase the accuracy of RF fingerprinting indoor tracking system by the use of additional information from simple vision system is examined. As the distances in signal space differs from ones in real environment the ambiguity in decision process of fingerprinting algorithm can occur when set of closest distances between tag and map points in signal space corresponds to big distances differences...
-
Marcinkiewicz Averages of Smooth Orthogonal Projections on Sphere
PublicationWe construct a single smooth orthogonal projection with desired localization whose average under a group action yields the decomposition of the identity operator. For any full rank lattice \Gamma ⊂ R^d , a smooth projection is localized in a neighborhood of an arbitrary precompact fundamental domain R^d / \Gamma. We also show the existence of a highly localized smooth orthogonal projection, whose Marcinkiewicz average under the...
-
Analysis of magnetic field of Hemholtz's coils and ferromagnetic objects
PublicationThe 3-axis fluxgate magnetometer requires conducting a precise calibration in the magnetic field whose value is determined and which is characterized by the high uniformity of the distribution of the field, especially along the axis of the sensors. The generation of the magnetostatic field characterized by the high uniformity, can be achieved by using the Helmholtz's coils. The requirements of the uniformity of distribution of...
-
Magnetic properties of ferromagnetic Pu2Pt3Si5
PublicationThe structural, magnetic, and thermodynamic properties of a new plutonium based compound, Pu2Pt3Si5, are reported. Single crystals produced by a Sn-flux technique have been analyzed showing a ferromagnetic behavior at 58 K. Pu2Pt3Si5 crystallizes in the U2Co3Si5-type orthorhombic Iabm structure (s.g. 72) with atomic parameters a = 9.9226(2) Å, b = 11.4436(2) Å and c = 6.0148(1) Å. The effective (leff 0.74 lB/Pu) and saturated (rsat...
-
New semi-causal and noncausal techniques for detection of impulsive disturbances in multivariate signals with audio applications
PublicationThis paper deals with the problem of localization of impulsive disturbances in nonstationary multivariate signals. Both unidirectional and bidirectional (noncausal) detection schemes are proposed. It is shown that the strengthened pulse detection rule, which combines analysis of one-step-ahead signal prediction errors with critical evaluation of leave-one-out signal interpolation errors, allows one to noticeably improve detection results...
-
The conditions of the business services sector in Poland and its competitiveness in the global market
PublicationThe following article presents the conditions of the business services sector (BSS) in Poland and the assessment of its competitiveness in the global market. The first section discusses the BSS sector and the categories of the provided services, in the division of business process outsourcing, shared services center, information technology outsourcing, research and development. Next the authors presents the status of the business...
-
Squamous cell carcinoma, NOS - Male, 69 - Tissue image [8190729597429231]
Open Research DataThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Squamous cell carcinoma, NOS - Male, 69 - Tissue image [12060630017627691]
Open Research DataThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Typical carcinoid - Female, 46 - Tissue image [8180729594146951]
Open Research DataThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Typical carcinoid - Female, 46 - Tissue image [818072959414301]
Open Research DataThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Typical carcinoid - Female, 46 - Tissue image [8180729594147711]
Open Research DataThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Typical carcinoid - Female, 46 - Tissue image [8180729594141961]
Open Research DataThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Atypical carcinoid tumor - Male, 61 - Tissue image [8180729594131521]
Open Research DataThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Carcinoid tumor, NOS - Female, 46 - Tissue image [8230729577645461]
Open Research DataThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
A variational approach of homogenization of piezoelectric composites towards piezoelectric and flexoelectric effective media
PublicationThe effective piezoelectric properties of heterogeneous materials are evaluated in the context of periodic homogenization, whereby a variational formulation is developed, articulated with the extended Hill macrohomogeneity condition. The entire set of homogenized piezoelectric moduli is obtained as the volumetric averages of the microscopic properties of the individual constituents weighted by the displacement and polarization...
-
The ONETEP linear-scaling density functional theory program
PublicationWe present an overview of the ONETEP program for linear-scaling density functional theory (DFT) calculations with large basis set (planewave) accuracy on parallel computers. The DFT energy is computed from the density matrix, which is constructed from spatially localized orbitals we call Non-orthogonal Generalized Wannier Functions (NGWFs), expressed in terms of periodic sinc (psinc) functions. During the calculation, both the...
-
Typical carcinoid - Female, 46 - Tissue image [8180729594146601]
Open Research DataThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Squamous cell carcinoma, NOS - Male, 69 - Tissue image [8190729597422021]
Open Research DataThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Squamous cell carcinoma, NOS - Male, 69 - Tissue image [8190729597422241]
Open Research DataThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Squamous cell carcinoma, NOS - Male, 69 - Tissue image [8190729597421991]
Open Research DataThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Atypical carcinoid tumor - Male, 61 - Tissue image [818072959413671]
Open Research DataThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Squamous cell carcinoma, NOS - Male, 69 - Tissue image [8190729597424991]
Open Research DataThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Using an IEEE1149.1 Test Bus for Fault Diagnosis of Analog Parts of Electronic Embedded Systems
PublicationThe new solution of a BIST called the JTAG BIST for self-testing of analog parts of electronic embedded systems is presented in the paper. The JTAG BIST consists of the BCT8244A and SCANSTA476 integrated circuits of Texas Instruments controlled via the IEEE 1149.1 bus. The BCT8244A is a scan test device with octal buffers, and the SCANSTA476 is a 12-bit ADC with 8 analog input channels. Self-testing approach is based on the fault...
-
Two‐functional μBIST for Testing and Self‐Diagnosis of Analog Circuits in Electronic Embedded Systems
PublicationThe paper concerns the testing of analog circuits and blocks in mixed‐signal Electronic Embedded Systems (EESs), using the Built‐in Self‐Test (BIST) technique. An integrated, two‐functional, embedded microtester (μBIST) based on reuse of signal blocks already present in an EES, such as microprocessors, memories, ADCs, DACs, is presented. The novelty of the μBIST solution is its extended functionality. It can perform 2 testing functions:...
-
Influence of a Radio Frequency on RF Fingerprinting Accuracy Based on Ray Tracing Simulation
PublicationIn this paper the influence of a radio signal frequency on performance of Indoor Positioning System based on fingerprinting has been examined using ray-tracing simulations. It has been simulated how spatial distribution of an RF signal strength change with the signal’s frequency. The results were used to show its’ impact on the behavior of localization algorithms that are employing RSS measurements to determine node’s position...
-
Pulmonary hamartoma - Female, 34 - Tissue image [8310729566963171]
Open Research DataThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Pulmonary hamartoma - Female, 34 - Tissue image [8310729566963891]
Open Research DataThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Small cell carcinoma, NOS - Male, 75 - Cell image [8190729597422441]
Open Research DataThis is the histopathological image of BRONCHUS AND LUNG cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Squamous cell carcinoma, NOS - Male, 69 - Tissue image [8190729597421731]
Open Research DataThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Visual Object Tracking System Employing Fixed and PTZ Cameras
PublicationThe paper presents a video monitoring system utilizing fixed and PTZ cameras for tracking of moving objects. First type of camera provides image for background modelling, being employed for foreground objects localization. Estimated objects locations are then utilised for steering of PTZ cameras when observing targeted objects with high close-ups. Objects are classified into several classes, then basic event detection is being...
-
Asynchronous Wide Area Multilateration System
PublicationA new method for a location service in the wide area multilateration (WAM) system is outlined. This method, which is called asynchronous WAM (AWAM), enables calculation of the geographical position of an aircraft without knowledge of relative time differences (RTDs) between measuring ground stations (sensors). The AWAM method is based on the measurement of round trip times (RTTs) between the aircraft and the serving ground station,...
-
Analysis of Properties of an Active Linear Gesture Sensor
PublicationBasic gesture sensors can play a significant role as input units in mobile smart devices. However, they have to handle a wide variety of gestures while preserving the advantages of basic sensors. In this paper a user-determined approach to the design of a sparse optical gesture sensor is proposed. The statistical research on a study group of individuals includes the measurement of user-related parameters like the speed of a performed...
-
A Comprehensive Experimental and Theoretical Study on the[{(η5-C5H5)2Zr[P(µ-PNEt2)2P(NEt2)2P]}2O Crystalline System
PublicationThe structure of tetraphosphetane zirconium complex C52H100N8OP10Zr21 was determined by single crystal X-ray diffraction analysis. The crystal belongs to the monoclinic system, space group P21/c, with a = 19.6452(14), b = 17.8701(12), c = 20.7963(14)Å, α = γ = 90°, β = 112.953(7)°, V = 6722.7(8)Å3, Z = 4. The electronic structure of the organometallic complex has been characterized within the framework of Quantum Chemical Topology....
-
Typical carcinoid - Female, 46 - Tissue image [8180729594145661]
Open Research DataThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.