Filters
total: 10651
displaying 1000 best results Help
Search results for: NICKEL-BASED ELECTRODES
-
Lead(II)-selective ionophores for ion-selective electrodes: A review
Publication -
Tuning of the Electrochemical Properties of Transparent Fluorine-doped Tin Oxide Electrodes by Microwave Pulsed-plasma Polymerized Allylamine
PublicationWe report here the dry, one-step, and low-temperature modification of FTO surfaces using pulsed plasma polymerization of allylamine (PPAAm). PPAAm/FTO surfaces were characterized by X-ray photoelectron spectroscopy, spectroscopic ellipsometry, and contact angles to understand the morphological, structural, and optical properties. FTO were coated with a very thin layer of adherent cross-linked, pinhole-, and additive-free allylamine...
-
Redetermination of bis(O,O′-diethyl dithiophosphato-κ2S,S′)nickel(II)
Publication -
The effect of temperature during soybean oil hydrogenation on nickel catalyst poisoning by phospholipids.
Publication.
-
Chlorido(1-pyrrolidinecarbodithioato-k2S,S')(triphenylphosphine)nickel(II)chloroform hemisolvate
PublicationTytułowy kompleks chloro(1-pirolidynoditiokarbaminiano-S,S')(trifenylofosfina)-nikiel(II), będący hemisolwatem chloroformu zawiera płaski rdzeń o składzie NiClS2P. Molekuły chloroformu oddziałują z kompleksem poprzez słabe wiązania C-H...S.
-
Enhanced Degradation of Ethylene in Thermo-Photocatalytic Process Using TiO2/Nickel Foam
Publication -
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the knees - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, drl at the buttocks - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, drl at the knees - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the buttocks - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, bath simulation - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
Knowledge-based performance-driven modeling of antenna structures
PublicationThe importance of surrogate modeling techniques in the design of modern antenna systems has been continuously growing over the recent years. This phenomenon is a matter of practical necessity rather than simply a fashion. On the one hand, antenna design procedures rely on full-wave electromagnetic (EM) simulation tools. On the other hand, the computational costs incurred by repetitive EM analyses involved in solving common tasks...
-
Worldviews on Evidence-Based Nursing
Journals -
Journal of Evidence-Based Psychotherapies
Journals -
Bio-based and Applied Economics
Journals -
Evidence-Based Mental Health
Journals -
Journal of Location Based Services
Journals -
Evidence Based Care Journal
Journals -
Journal of Evidence-Based Medicine
Journals -
Journal of Gender-Based Violence
Journals -
BMJ Evidence-Based Medicine
Journals -
Study of oxygen electrode reactions on symmetrical porous SrTi0.30Fe0.70O3-δ electrodes on Ce0.8Gd0.2O1.9 electrolyte at 800 °C–500 °C
PublicationIron doped strontium titanates (SrTi1-xFexO3-δ) are an interesting mixed ionic-electronic conductor model used to study basic oxygen reduction/oxidation reactions. In this work, we performed an impedance spectroscopy study on symmetrical porous SrTi0.30Fe0.70O3-δ (STF70) electrodes on a ceriabased electrolyte. The sample was measured in varying oxygen concentration: from 0.3% to 100% in 800 °C - 500 °C temperature range. Low polarisation...
-
An agent-based approach to ANN training
Publication -
Mn-Co nanofilms on nickel foam measured by XPS mehod
Open Research DataManganium-Cobaltium based thin films were electrochemically deposited on a Ni based subsrates in a one-step process at −1.1 V vs. Ag/AgCl in an aqueous solution of differently concentrated Mn(NO3)2·4H2O and Co(NO3)2·6H2O with the deposition time limited by charges of 60, 120, and 200 mC at 25 °C. The concentration ratios of Mn(NO3)2·4H2O to Co(NO3)2·6H2O...
-
Marek Adamowicz dr hab. inż.
PeopleStopień naukowy doktora uzyskał w 2008 r. na Wydziale Elektrotechniki i Automatyki Politechniki Gdańskiej. W latach 2005 – 2011 pracował na Akademii Morskiej w Gdyni. W 2010 r. jako laureat programu NCBR LIDER wybrał Wydział Elektrotechniki i Automatyki Politechniki Gdańskiej jako jednostkę realizującą swój projekt z zakresu szerokopasmowych przyrządów półprzewodnikowych i ich zastosowań w elektrowniach wiatrowych. Od 2011 roku...
-
Effect of oxygenation time on signal of a sensor based on ionic liquids
PublicationThe paper presents an oxygen sensor based on ionic liquids and solid electrodes. The following ionic liquids have been employed: [BMIM][BF4], [HMIM][Cl], [BMIM][N(CN2)]. Minimum time of the sensor exposure to analyte, after which the signal (current intensity) was stable, has been evaluated. An impact of volumetric flow rate of analyte on the sensor exposure time and signal has been determined. A product of permeability coefficient...
-
A novel hierarchically-porous diamondized polyacrylonitrile sponge-like electrodes for acetaminophen electrochemical detection
PublicationA novel composite electrode material consisting of tangled fibrous polyacrylonitrile-based hierarchically-struc- tured nanocomposites has been produced by wet-spinning, carbonized and decorated with a carbon nano- architecture by microwave plasma-enhanced chemical vapor deposition and investigated as a metal-free electrode for the enhanced electrochemical detection of acetaminophen. Surprisingly, the hierarchical fiber ar- chitecture...
-
Helium-assisted, solvent-free electro-activation of 3D printed conductive carbon-polylactide electrodes
PublicationFused filament fabrication is one of the most rapidly developing 3D printing techniques, with numerous applications, including in the field of applied electrochemistry. Here, the utilisation of conductive carbon black polylactic acid (CB-PLA) for 3D printouts is the most promising. To use CB-PLA as an electrode material, an activation process must be performed, removing the polymer matrix and uncovering the electrically conductive...
-
Effects of thermal history on the performance of low-temperature solid oxide fuel cells with Sm0.2Ce0.8O2-δ electrolyte and LiNi0.81Co0.15Al0.04O2 electrodes
PublicationIn this study, low-temperature solid oxide fuel cells with an ∼560 μm thick Sm0.2Ce0.8O2−δ (SDC) electrolyte and ∼890 μm thick LiNi0.81Co0.15Al0.04O2−δ (NCAL) electrodes are constructed and characterized under three experimental conditions. The cell with an NCAL cathode pre-reduced under an H2 atmosphere at 550 °C presents the best electrochemical performance. This is ascribed to facts that the reduction reaction generating Ni–Co...
-
Evidence-based Complementary and Alternative Medicine
Journals -
ECG measurement in the bathtub - electrodes at the feet, drl behind the back - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, sitting motionless - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, placed on the back - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, bath simulation - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - sitting on measuring electrodes, drl in water - men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
Polypyrrole based gas sensor for ammonia detection
PublicationThe nature of polypyrrole response to toxic gases does not allow using the sensor in a conventional way. The main aim of this study is to acquire the information about the concentration using different approaches: a linear approximation, a non-linear approximation and a tangent method. In this paper a two-steps procedure for sensor response measurements has been utilized. Polypyrrole films were electrochemically synthesized on...
-
Investigation of sour substances by a set of all-solid-state membrane electrodes
PublicationTestowano elektrody typu all solid state (ASS) w roztworach elektrolitów zawierających substancje o smaku kwaśnym. Elektrody typu ASS zawierają dwa typy membran. Badano wpływ grubości membrany oraz stosunku związek lipofilowy/ chlorek poliwinilu na odpowiedzi elektrod. Stwierdzono, że grubość elektro aktywnego polimeru, nie ma wpływu na czułość i stabilność elektrod w przeciwieństwie do grubości membrany składającej się ze związku...
-
Preparation and characterisation of visible light responsive iodine doped TiO2 electrodes
PublicationPraca przedstawia charakterystykę domieszkowanego jodem ditlenku tytanu (I-TiO2) otrzymanego na drodze hydrotermicznej syntezy, gdzie prekursor stanowiły komplesy tytanu (IV) z ligandami zawierającymi atom jodu. Struktura nowego materiału została opisana za pomocą technik XPS, XRD, UV-vis i FT-IR-ATR. Badania te potwierdziły, że otrzymany proszek I-TiO2 ma zmniejszoną przerwę energetyczną. Praca prezentuje również badania elektrochemiczne...
-
Plasticized PVC Membrane Modified Electrodes: Voltammetry of Highly Hydrophobic Compounds
Publication -
Diagnosis of reference electrodes in cathodic protection systems by electrochemical impedance spectroscopy
PublicationPrzedstawiono wyniki badań laboratoryjnych i terenowych przeprowadzonych techniką elektrochemicznej spektroskopii impedancyjnej (EIS). Zaprezentowano widma impedancyjne następujących układów: elektroda odniesienia/elektroda pomocnicza; rurociąg/zakopane i przenośne elektrody odniesienia. Pokazano, że omawiana technika umożliwia badanie stanu technicznego elektrod odniesienia, co zwiększa pewność wyników pomiarów potencjału chronionej...
-
Electrochemical oxidation of ionic liquids at highly boron doped diamond electrodes
PublicationUtlenianie elektrochemiczne przy zastosowaniu elektrod diamentowych wysoko domieszkowanych borem (BDD) było badane pod względem przydatności do utylizacji roztworów zawierających ciecze jonowe (ILs). Dwustronne elektrody Si/BDD przygotowano metodą chemicznego osadzania z fazy lotnej wspomaganego plazmą (MW PE CVD). Badanie przy użyciu skaningowej mikroskopii elektronowej (SEM) potwierdziło, że wytworzone warstwy były ciągłe i miały...
-
Electrochemical oxidation of ionic liquids at highly boron doped diamond electrodes
Publication -
On stability of iodine doped TiO2 electrodes in pH varied aqueous electrolytes
PublicationW pracy przedstaiono charakterystykę elektrochemiczną warstwy domieszkowanego jodem TiO2 na podłożu platynowym. Wyniki badań prowadzone w elektrolitach o różnym pH pozowoliły na określenie właściwości na granicy faz elektroda - elektrolit. Wyznaczono zależność potencjału pasma płaskiego od pH elektrolitu, a charakter otrzymanej funkcji potwirdził stabilność proszku I-TiO2 w kontakcie s roztworem.
-
Enzymatic electrodes nanostructured with functionalized carbon nanotubes for biofuel cell applications
PublicationNanostructured bioelectrodes were designed and assembled into a biofuel cell with no separating membrane.
-
Carbon nanoarchitectures as high-performance electrodes for the electrochemical oxidation of landfill leachate
PublicationNanomaterials and assemblies of the aforementioned into complex architectures constitute an opportunity to design efficient and selective solutions to wide spread and emerging environmental issues. The limited disposal of organic matter in modern landfills generates extremely concentrated leachates characterised by high concentrations of refractory compounds. Conventional biochemical treatment methods are unsuitable, while advanced...
-
Silicon Oxycarbide-Graphite Electrodes for High-Power Energy Storage Devices
PublicationHerein we present a study on polymer-derived silicon oxycarbide (SiOC)/graphite composites for a potential application as an electrode in high power energy storage devices, such as Lithium-Ion Capacitor (LIC). The composites were processed using high power ultrasound-assisted sol-gel synthesis followed by pyrolysis. The intensive sonication enhances gelation and drying process, improving the homogenous distribution of the graphitic...
-
Application of electrochemical impedance spectroscopy to monitoring discharging process of nickel/metal hydride battery
Publication -
Increase in wear resistance of nickel plasma coatings under traditional and combined treatment conditions
Publication -
Application of TiO2 Supported on Nickel Foam for Limitation of NOx in the Air via Photocatalytic Processes
Publication -
The anisotropic photorefractive effect in lithium sulfo-phosphate glass system doped with nickel ions
Publication