Search results for: SOFTWARE DESIGN
-
A Device for Measuring Auditory Brainstem Responses to Audio
PublicationStandard ABR devices use clicks and tone bursts to assess subjects’ hearing in an objective way. A new device was developed that extends the functionality of a standard ABR audiometer by collecting and analyzing auditory brainstem responses (ABR). The developed accessory allows for the use of complex sounds (e.g., speech or music excerpts) as stimuli. Therefore, it is possible to find out how efficiently different types of sounds...
-
ECG measurement in the bathtub - drl on the outside of the bathtub on one side- men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, drl behind the back - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at buttocks, strengthening 2x smaller, drl at buttocks - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the buttocks, drl at the feet - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - one side of the bathtub is grounded, drl outside the bathtub - men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the knees - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, sitting motionless - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the knees, signal amplification x2 - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the buttocks, drills at the feet, grounding the bathtub - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, placed on the back - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - sitting on the measuring electrodes, drl outside the bathtub - men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl on the outside of the bathtub on both sides, measuring electrodes on the front and back of the bathtub- men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl in the water, measuring electrodes on the sides of the bathtub - men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl on one side of the bath mass on the other - the person is moving- men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl outside the bathtub on both sides- men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl in water, front and back measuring electrodes - men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, bath simulation - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - sitting on measuring electrodes, drl in water - men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, drl at the buttocks - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl on one side of the bath, the mass of the system on the other- men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - conversation during measurement, electrodes on the sides of the bathtub, drl in water - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl in the bathtub, electrodes on the sides of the bathtub - men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, drl at the knees - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the buttocks - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, bath simulation - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - buttocks electrodes, reinforcement 2x smaller, drl on knees - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
Stabalization of solar-panel energy system for Pakistani household
PublicationRenewable energy resources such as Sun and wind are getting popular and easier to use day by day. It is a better method to fulfill our demands as sun is a continuous source of energy for Earth. Many countries are fulfilling their demands by Solar Panels. Solar panel is used as a converter between sunlight and electrical energy. This research paper is going to tell that how to obtain electrical energy from sunlight more efficiently...
-
Experimental study and numerical optimization of tensegrity domes – A case study
PublicationThe paper deals with the design, experimental analysis and numerical optimization of tensegrity dome models. Two structures are analyzed – a Geiger system dome (preliminary dome), with PVC-U bars and PA6/PP/PET tendons and a Fuller system dome (target dome), with wooden bars and steel cables as tendons. All used materials are experimentally tested in terms of Young's modulus and yield stress values, the compressed bars are also...
-
CAD. Integrated Architectural Design BSc in Arch., sem 3 2022/2023
e-Learning CoursesDuring the course students will learn how to use BIM (Building Information Modelling) tools to model the project site and to develop preliminary design concept.Students will work in pairs or groups, using Autodesk Revit software for terrain, site and building modelling.
-
The dynamic performance analysis of the Micro-turbine's rotor supparted on slide and roling element bearings
PublicationThis article presents the results of investigations of dynamic characteristics of a small-dimension rotor with slide and rolling element bearings. The object of investigations was the rotor-bearing system designed for the ORC based low-power steam micro-turbine. The investigations were performed using MESWIR series programs, as well as commercial FEA software ABAQUS and MADYN 2000. The results of modal analysis of the micro-rotor...
-
Justifying the prolongation of the service life of the bearing structure of a tank car when using Y25 bogies
PublicationThis paper substantiates the use of Y25 bogies under tank cars in order to prolong their service life. The reported study has been carried out for a tank car with rated parameters, as well as the actual ones, registered during full-scale research. Mathematical modeling was performed to determine the basic indicators of the tank car dynamics. The differential equations of motion were solved by a Runge-Kutta method using the Mathcad...
-
Investigation of the Effects of Tool Positioning Factors on Peak Temperature in Dissimilar Friction Stir Welding of AA6061-T6 and AA7075-T6 Aluminum Alloys
PublicationAmong the emerging new welding techniques, friction stir welding (FSW) is used frequently for welding high-strength aluminum alloys that are difficult to weld by conventional fusion-welding techniques. This paper investigated the effects of tool-positioning factors on the maximum temperature generated in the dissimilar FSW joint of AA6061-T6 and AA7075-T6 aluminum alloys. Three factors of plunge depth, tool offset, and tilt angle...
-
On topology optimization of large deformation contact-aided shape morphing compliant mechanisms
PublicationA topology optimization approach for designing large deformation contact-aided shape morphing compliant mechanisms is presented. Such mechanisms can be used in varying operating conditions. Design domains are described by regular hexagonal elements. Negative circular masks are employed to perform dual task, i.e., to decide material states of each element and also, to generate rigid contact surfaces. Each mask is characterized by...
-
Loosely-Tied Distributed Architecture for Highly Scalable E-Learning System
PublicationVast majority of modern e-learning products are based on client-server architecture and utilization of web-based technologies (WBT). Such approach permits easy creation of e-learning systems that do not require a complex, operating system dependant client software. Unfortunately there are also drawbacks of such solution. Because of the majority of mechanisms are located on the server, its usage levels trend to build up quickly...
-
ECG measurement in the bathtub - drl on one side of the bathtub, the other side of the bathtub is grounded and the system ground is grounded- men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
Universal autonomous control and management system for multipurpose unmanned surface vessel
PublicationThe paper presents design, structure and architecture of the Universal Autonomous Control and Management System (UACAMS) for multipurpose unmanned surface vessel. The system was designed, installed and implemented on the multipurpose platform - unmanned surface vessel named HydroDron. The platform is designed to execute hydrographic survey missions with multi-variant configuration of the survey system (payload? ) including multi-beam...
-
The Ellenbogen’s “Matter as Software” Concept for Quantum Computer Implementation: IV. The X@C60 Molecular Building Blocks (MBBs) and Computing System Lifetime Estimation
PublicationThe problem of approximate lifetimes of individual X@C60 MBBs and tip-based nanofabricated quantum computing device systems is discussed under the conservative assumption of single-point failure. A single chemical transformation of the C60 cage into high-energy opened o-C60 isomer which forms the communication canal for the low energy transfer of an X atom from X@C60 MBB to the outside environment was studied. According to the...
-
Hybrid Fuzzy-Ontological Project Framework of a Team Work Simulation System
PublicationThe aim of this article is to present the project framework for constructing a Software Process Simulation Modeling (SPSM) system. SPSM systems can be used as a virtual environment for the selection of methods and tools of project management in IT support organizations. The constructed system simulates the Scrum methodology, including the management processes and the project roles. For the implementation of Scrum processes, the...
-
Greenhouse control system design
PublicationCoraz większa populacja i zmniejszające się tereny uprawne wymusza efektywniejsze metody uprawy roślin. Zaradzić temu mogą układu hydroponiczne, które dzięki rozwojowi techniki są w stanie osiągać znacznie większe oraz bardziej jednorodne plony. Jest to możliwe dzięki zaawansowanym systemom opartym na dokładnych urządzeniach pomiarowych, sterowaniu w zamkniętej pętli oraz mikrokontrolerom umożliwiającym...
-
Arsalan Muhammad Soomar Doctoral Student
PeopleHi, I'm Arsalan Muhammad Soomar, an Electrical Engineer. I received my Master's and Bachelor's Degree in the field of Electrical Engineering from Mehran University of Engineering and Technology, Jamshoro, Sindh, Pakistan. Currently enrolled as a Doctoral student at the Gdansk University of Technology, Gdansk, Poland. Also worked in Yellowlite. INC, Ohio as a Solar Design Engineer. HEADLINE Currently Enrolled as a Doctoral...
-
Feasibility Study GaN Transistors Application in the Novel Split-Coils Inductive Power Transfer System with T-Type Inverter
PublicationA promising solution for inductive power transfer and wireless charging is presented on the basis of a single-phase three-level T-type Neutral Point Clamped GaN-based inverter with two coupled transmitting coils. The article focuses on the feasibility study of GaN transistor application in the wireless power transfer system based on the T-type inverter on the primary side. An analysis of power losses in the main components of the...
-
Toolchain Modeling: Comprehensive Engineering Plans for Industry 4.0
PublicationThe fourth industrial revolution (Industry 4.0) elevates the complexity and autonomy of industrial systems and engineering environments to levels not seen before. The novel challenges involve not only the software running on the partaking autonomous devices, but also architectural considerations and the technological infrastructure around the entire engineering process. In this paper, complementing the trends in industrial systems...
-
NUMERICAL ANALYSIS OF RUBBER BUMPERS INFLUENCE ON THE COLLIDING STEEL STRUCTURES
PublicationProblem of collisions of neighbouring structures is one of the important issues related to the safety of civil engineering structures. The safety and reliability of steel structures under impact loading is among a number of different aims during the design state. The aim of this paper is to present the results of numerical investigation of dynamic behavior of closely-separated steel structures under seismic excitation. Modal and transient...
-
Cognitum Ontorion: Knowledge Representation and Reasoning System
Publication“If knowledge can create problems, it is not through ignorance that we can solve them.” (Isaac Asimov). Nevertheless, at any point of human activity, knowledge (besides practice) is a key factor in understanding and solving any given problem. Nowadays, computer systems have the ability to support their users in an efficient and reliable way. In this paper we present and describe the functionality of the Cognitum Ontorion system....
-
Behaviour of steel columns under impact
PublicationOne of import issues related to the idea of sustainable society is the safety of civil engineering structures. The safety and reliability of steel structures under impact loading is among a number of different aims during the design state. The aim of this paper is to present the results of investigation focused on dynamic behaviour of steel columns under impact loading. Modal and transient dynamic analyses using Finite Element...
-
Analiza obudowy wykopu dla budynku z kondygnacją podziemną
PublicationW pracy poruszono tematykę analizy obudowy wykopu dla budynku z jedną kondygnacją podziemną, zlokalizowanego w gęstej zabudowie śródmiejskiej. Obliczenia przeprowadzono za pomocą dwóch programów obliczeniowych: GEO5 (moduł: Ściana analiza) i Autodesk Robot Structural Analysis Professional. Całość wyników podsumowano, a wnioski sformułowano w odniesieniu do obecnej sytuacji na rynku budowlanym, charakteryzującej się coraz to trudniejszymi...
-
<title>Software layer for SIMCON ver. 2.1. FPGA based LLRF control system for TESLA FEL part II: application layer, networking, examples</title>
Publication -
Evaluation of open drone map toolkit for geodetic grade aerial drone mapping – case study
PublicationAn open source tool’s popularity has increased considerably, as well as micro aerial vehicles (MAV) technologies based on open source hardware. An open source software and hardware delivers a wide variety of applications and technology. The world’s most successful open source projects have their roots in the academy, and now its participation includes a wide variety of academic programs and research. Based on open source technology,...
-
AGREEMIP: The Analytical Greenness Assessment Tool for Molecularly Imprinted Polymers Synthesis
PublicationMolecular imprinting technology is well established in areas where a high selectivity is required, such as catalysis, sensing, and separations/sample preparation. However, according to the Principles of Green Chemistry, it is evident that the various steps required to obtain molecularly imprinted polymers (MIPs) are far from ideal. In this regard, greener alternatives to the synthesis of MIPs have been proposed in recent years....