Search results for: ELECTRICAL MEASUREMENT
-
A Thermographic Measurement Approach to Assess Supercapacitor Electrical Performances
PublicationThis paper describes a proposal for the qualitative assessment of condition of supercapacitors based on the conducted thermographic measurements. The presented measurement stand was accompanied by the concept of methodology of performing tests. Necessary conditions, which were needed to minimize the influence of disturbing factors on the performance of thermal imaging measurements, were also indicated. Mentioned factors resulted...
-
Virtual Models of Analog-Digital Converters in Education of Electrical Measurements and Instrumentation.
PublicationPrzedstawiono opracowane przez autorów przyrządy wirtualne do demonstracji działania przetworników analogowo-cyfrowych: integracyjnego, kompensacyjnego, sigma-delta, z pośrednim sygnałem częstotliwościowym. Programy umożliwiają obserwację zmian napięcia w punktach charakterystycznych układów w spowolnionej skali czasowej. Możliwe jest również zadawanie zakłóceń.
-
Optical Fibre Control-Measurement Systems Of Compound HV/HP Electrical Equipment
Publication -
Assessment of copper surface coverage with corrosion inhibitor using AFM-based local electrical measurements
PublicationThe paper presents a new method of assessment of metal surface coverage with corrosion inhibitor and thus of inhibitor protective performance. It is based on the atomic force microscopy measurement performed in a contact mode. Apart from topography images the proposed approach allows acquisition of local DC maps and local electrical impedance spectra via application of DC bias voltage or AC perturbation signal between the conductive...
-
Application of electrical capacitance tomography (ECT) to measurement of sand concentration changes during silo flow
PublicationW artykule przedstawiono wyniki doświadczeń pomiaru zmian koncentracji materiału granulowanego podczas przepływu silosowego. Zmiany zostały pomierzone przy pomocy tomografu. Doświadczenia wykonano w silosie cylindrycznym dla 2 różnych szorstkości ścian.
-
Electrical measurement data for SOFC fueled by H2 and biogas mixture at 750 C
Open Research DataThe dataset contains the Electrical measurement data for SOFC fueled by H2 (30h) and biogas mixture at 750 C (60:40 CH4:CO2). The investigation of long-term electrical stability was performed during initial SOFC feeding with hydrogen (for 30 h) and further with biogas (for 90 h). The electrical properties of the fuel cell were measured using the HAMEG...
-
The Effect of Full-Cell Impregnation of Pine Wood (Pinus sylvestris L.) on Changes in Electrical Resistance and on the Accuracy of Moisture Content Measurement Using Resistance Meters
PublicationThe impact of the full-cell impregnation of pine wood was investigated with respect to changes in electrical resistance and the accuracy of moisture content measurement. This study compared the resistance of impregnated and untreated pine timber harvested from the northern part of Poland (Pomeranian region). The wood was impregnated by the vacuum-pressure method. The preservative (TANALITH E 3475) and coloring (TANATONE 3950) agents...
-
Electrical power measurement of reference SOFC fueled by biogas mixture at 750 C
Open Research DataThe dataset contains the electrical measurements of IV curves for SOFC without La0.27Sr0.54Ce0.09Ni0.1Ti0.9O3-s layer working under biogas and H2 feeding stream. The SOFC was reduced at 900C and conditioned for 12 h under H2 prior the measurements. The measurements were performed using Gamry potentiostat/galvanostat
-
Electrical power measurement of LSCNT modified SOFC fueled by biogas mixture at 750 C
Open Research DataThe dataset contains the electrical measurements of IV curves for SOFC with La0.27Sr0.54Ce0.09Ni0.1Ti0.9O3-s layer working under biogas and H2 feeding stream. The SOFC was reduced at 900C and conditioned for 12 h under H2 prior the measurements. The measurements were performed using Gamry potentiostat/galvanostat
-
Electrical performance measurement of reference and SOFC with LSCNT layer fueled by H2 and 20ppm H2S/biogas mixture at 750 C - cyclic measurements (12h per cycle)
Open Research DataThe dataset contains the electrical IV measurements collected during the cyclic measurements of H2S poisoning in DIR-SOFC with/-out LSCNT layer. The H2S poisoning and H2 regenrating cycles were 12 h each. The spectra were collected every 10 min.
-
Electrical measurements of the dewetting of metal thin films
Open Research DataIn situ observations of dewetting of thin films is very complicated. One of the method, that helps to observe it, could be electrical measurements. For experiments, thin gold, silver and gold-silver nanoalloy films were deposited by magnetron sputtering method. Films were deposited on a Corning glass substrates. Samples were measured by four point method...
-
D.C. electrical measurements of Bi2VO5.5 ceramic measured at high temperature region
Open Research DataD.C. electrical properties of Bi2VO5.5 ceramic was measured.
-
Effect of Time Varying Measurement Conditions on Antenna Pattern in Near Field Measurement and Its Correction Procedure
PublicationAuthors present the procedure of taking into account the changes of electrical parameters of setup due to the time drift of temperature during the procedure of near field measurement. It is proposed to make additional measurements in determined positions of probe are next used the results to introduce corrections terms in measured data. Such approach was verified practically in experimental near field measurement system.
-
Effects of mechanical stress on electrical arameters and noise of supercapacitors
PublicationResults of noise and electrical parameters measurements of prototype electrochemical double layer capacitors (EDLC) are reported at the presence of selected mechanical stress. This issue is of great importance due to future applications in wearable technology. The measurement results are compared, and we may conclude than flicker noise is more sensitive to any stress than other considered electrical parameters.
-
Electrical conductivity relaxation measurements - oxidation and reduction of BaCe0.6Zr0.2Y0.1Tb0.1O3-δ
Open Research DataThe dataset consists of 2 main catalogs: measurements performed for oxidation/reduction in dry conditions and in humid conditions. For Electrical Conductivity Relaxation (ECR) measurements, platinum reversible electrodes were applied in a four-probe arrangement and the sample was measured in the ProboStat™ measurement system. The ECR measurements were...
-
Wood Moisture-Content Measurement Accuracy of Impregnated and Nonimpregnated Wood
PublicationThe influence of the impregnation process of pine wood (Pinus sylvestris L.) samples on the electrical resistance changes and the moisture-content measurement accuracy is presented in this paper. In this study, the resistances of impregnated and nonimpregnated green pine timber harvested from northern Poland were compared. An impregnation method based on a vacuum-pressure chamber was used. Copper salts were applied as the impregnated...
-
Remote current measurement with FPGA digital processing
PublicationThe work presents an implementation of a modular measurement and control systemthat controls variants of mains supply of 230V electrical equipment. The system allowsto supervise power consumption in the office electronic equipment. The system detectsthe instant of the reduced power consumption by a device and makes possible itsswitch-off in order to reduce energy cost. The current is measured with integratedcurrent/voltage converters....
-
Electrical conductivity relaxation measurements - water uptake of BaCe0.6Zr0.2Y0.1Tb0.1O3-δ
Open Research DataFor Electrical Conductivity Relaxation (ECR) measurements, platinum reversible electrodes were applied in a four-probe arrangement and the BaCe0.6Zr0.2Y0.1Tb0.1O3-δ sample was measured in the ProboStat™ measurement system. The ECR measurements were performed in air in the temperature range of 450-800 ℃ after switching water partial pressure between...
-
Piotr Chrzan prof. dr hab. inż.
PeopleUrodził się w 1954 r. w Sopocie. Jest absolwentem Wydziału Elektroniki Politechniki Gdańskiej (1978). W 1980 r. podjął pracę na Wydziale Elektrycznym w zespole prof. Jerzego Jaczewskiego. W 1988 r. uzyskał stopień naukowy doktora nauk technicznych, habilitację w 1999 r., w zakresie elektrotechniki: energoelektroniki i automatyki napędu, a tytuł profesora w 2017 r. Był promotorem 6 obronionych prac doktorskich (w tym 3 z wyróżnieniem)....
-
Atomic force microscopy images of copper electrical contacts wear under the influence of friction
Open Research DataMeasurement of wear of copper electrical contacts under the influence of friction. Imaging in contact mode in the variant of scanning spreading resistance microscopy. Additionally, there are spectroscopic current-voltage curves showing local changes in electrical conductivity. NTEGRA Prima (NT-MDT) device. Probe NSG 01Pt.