Filters
total: 377
Search results for: aqueous samples
-
Comparison of High Performance Liquid Chromatography Methods with Different Detectors for Determination of Steroid Hormones in Aqueous Matrices
PublicationThis paper presents the development and comparison of procedures for the qualitative and quantitative determination of five estrogenic compounds (17-a-ethynylestradiol, estrone, estradiol, estriol, and progesterone) in drinking water and wastewater samples. Five extraction columns and two disks were tested for their efficiency. The C18 columns were superior on the basis of cost for solid phase extraction of drinking water or sewage....
-
VUV irradiation studies of plasmid DNA in aqueous solution
PublicationInteractions of VUV light and DNA samples in aqueous solutions are reported. The damage induced by such radiation is quantified by monitoring both loss of supercoiled DNA and formation of single and double strand breaks using agarose gel electrophoresis. Irradiations were performed using synchrotron VUV photons of 130, 150, 170 and 190 nm. VUV irradiation experiments revealed enhanced damage upon irradiation with 170 nm photons...
-
Optical-Spectrometry-Based Method for Immunosuppressant Medicine Level Detection in Aqueous Solutions
PublicationIn this paper, an investigation into detecting immunosuppressive medicine in aqueous solutions using a spectrometry-based technique is described. Using optical transmissive spectrometry, absorbance measurements in the spectra range from 250 nm to 1000 nm were carried out for different cyclosporine A (CsA) concentrations in aqueous solutions. The experiment was conducted for samples both with and without interferent substances—glucose...
-
Corrosion monitoring by harmonic analysis in aqueous environments
PublicationThis paper presents tests concerning the rate of corrosion in non-alloy steel (type S235JR) in an aqueous environment, with an additive of sodium chloride by means of polarization resistance measurements and harmonic analysis. The tests have been carried out for steel samples exposed to the testing environment for six weeks, in order to obtain a constant rate of corrosion in the function of time. The measurements have aimed at...
-
The XRD diffraction patterns of Ce(Gd,Pr)O2-s samples
Open Research DataThe dataset includes XRD diffraction patterns of Ce0.8Gd0.2O2-s and Ce0.8Pr0.2O2-s sintered at 600oC under air atmosphere for 4 h. Samples were produced using aqueous soft chemistry methods (Pechini).
-
The XRD diffraction patterns of LSCNT sintered at various temperatures
Open Research DataThe dataset includes XRD diffraction patterns of La0.27Sr0.54Ce0.09Ni0.1Ti0.9O3-s sintered at various temperatures under air atmosphere for 12 h. Samples were produced using aqueous soft chemistry methods (Pechini).
-
The XRD diffraction patterns of LSCNT of different A site nonstoichiometry
Open Research DataThe dataset includes XRD diffraction patterns of La0.27Sr0.54Ce0.09Ni0.1Ti0.9O3-s and La0.3Sr0.6Ce0.1Ni0.1Ti0.9O3-s sintered at 1200oC under air atmosphere for 12 h. Samples were produced using aqueous soft chemistry methods (Pechini).
-
Elucidation of transformation pathway of ketoprofen, ibuprofen, and furosemide in surface water and their occurrence in the aqueous environment using UHPLC-QTOF-MS
PublicationThe identification and determination of transformation products (TPs) of pharmaceuticals is essential nowadays, in order to track their fate in the aqueous environment and, thus, to estimate the actual pollution. However, this is a challenging task due to the necessity to apply high-resolution instruments enable to detect known and unknown compounds. This work presents the use of liquid chromatography quadrupole time-of-flight...
-
The XRD diffraction patterns of Ce(Pr,Sm)O2-s samples
Open Research DataThe dataset includes XRD diffraction patterns of Ce(Pr,Sm)O2-s samples of various stoichiometries of Pr and Sm dopants. Samples were produced using aqueous soft chemistry methods (microemulsion method).
-
The SEM images of LSCNT reduced at 900 degrees C under H2
Open Research DataThe dataset includes SEM image of La0.27Sr0.54Ce0.09Ni0.1Ti0.9O3-s sintered at 1200oC under air atmosphere for 12 h and reduced at 900oC under H2 for 10 h. Samples were produced using aqueous soft chemistry methods (Pechini).
-
The SEM images of LSCNT reduced at 800 degrees C under H2
Open Research DataThe dataset includes SEM images of La0.27Sr0.54Ce0.09Ni0.1Ti0.9O3-s sintered at 1200oC under air atmosphere for 12 h and reduced at 800oC under H2 for 10 h. Samples were produced using aqueous soft chemistry methods (Pechini).
-
The SEM images of LSCNT reduced at 1000 degrees C under H2
Open Research DataThe dataset includes SEM images of La0.27Sr0.54Ce0.09Ni0.1Ti0.9O3-s sintered at 1200oC under air atmosphere for 12 h and reduced at 1000oC under H2 for 10 h. Samples were produced using aqueous soft chemistry methods (Pechini).
-
The SEM images of LSCNT sintered at 1200 degrees C in air
Open Research DataThe dataset includes SEM images of La0.27Sr0.54Ce0.09Ni0.1Ti0.9O3-s sintered at 1200oC under air atmosphere for 12 h. Samples were produced using aqueous soft chemistry methods (Pechini). The grain structure can be seen on higher resolution image.
-
XRD and electrochemical results for MoO3 films deposited using pulsed laser deposition system
Open Research DataThe attached data contains XRD and electrochemical results for MoO3 films deposited on fluorine-doped tin oxide glasses. Films were deposited using a pulsed laser deposition system at different conditions. Part of the samples was deposited at room temperature and then annealed at 575°C for given times (samples labeled PLD_RT_575C_xmin, where x stands...
-
Removal efficiency of phenol by ozonation process with calcium peroxide from aqueous solutions
PublicationPhenol has been introduced as a priority pollutant by the US Environmental Protection Agency. Advanced oxidation processes (AOPs) are one of the most efcient methods for removal of non-degradable organic pollutants in aqueous solutions. The removal efciencies of phenol and COD under optimal conditions pH=3, phenol concentration=5 mg/L, CaO2 concentration=0.025 mg/L, temperature 25 °C, 1 g/min ozonation rate and contact time=90...
-
‘Green’ multi - residue methods for the determination of high importance currently used pesticides in environmental samples
PublicationThe purpose of the research has been to develop and apply ‘green’ analytical methodologies to control and monitor the level of currently used pesticides from different chemical groups in aqueous samples. For extraction of analytes solid - phase microextraction (SPME) and dispersive liquid - liquid microextraction (DLLME) have been applied and compared. For SPME, commonly used materials for coating fibers include: polydimethylsiloxane...
-
Occurrence and seasonal variations of 25 pharmaceutical residues in wastewater and drinking water treatment plants
PublicationThousands of tons of pharmaceuticals are introduced into the aqueous environment due to their incomplete elimination during treatment process in wastewater treatment plants (WWTPs) and water treat- ment plants (WTPs). The presence of pharmacologically active compounds in the environment is of a great interest because of their potential to cause negative effects. Furthermore, drugs can undergo different pro- cesses leading to the...
-
Evaluation of polycaprolactone as a new sorbent coating for determination of polar organic compounds in water samples using membrane–SPME
PublicationCommercially available solid-phase microextraction fibers used for isolation of polar analytes are based on the adsorption phenomenon. In consequence, typical limitations bonded with analytes displacement and matrix effects are very frequent. In the present study, alternative solution is described. Polycaprolactone (PCL) was used for the first time as sorbent to isolate polar organic compounds from water samples using the membrane–solid-phase...
-
Hydrophobic deep eutectic solvents in microextraction techniques–A review
PublicationOver the past decade, deep eutectic solvents (DES) have been widely studied and applied in sample preparation techniques. Until recently, most of the synthesized DES were hydrophilic, which prevented their use in the extraction of aqueous samples. However, after 2015 studies on the synthesis and application of hydrophobic deep eutectic solvents (HDES) has rapidly expanded. Due to unique properties of HDES i.e. density, viscosity,...
-
A procedure for the determination of dichloromethane and tetrachloroethene in water using pervaporation and gas chromatography
PublicationIn the present study, pervaporation was applied to the determination of tetrachloroethene (PCE) and dichloromethane (DCM) in liquid samples. PCE is the most commonly used solvent in dry-cleaning processes. PCE belongs to group 2A of carcinogens (probably carcinogenic to humans) according to the classification of the International Agency for Research on Cancer (IARC). DCM is also widely used as an industrial solvent for the purification...