Filters
total: 5638
filtered: 958
-
Catalog
- Publications 4175 available results
- Journals 23 available results
- Conferences 5 available results
- People 67 available results
- Inventions 2 available results
- Projects 7 available results
- Laboratories 1 available results
- Research Teams 2 available results
- Research Equipment 4 available results
- e-Learning Courses 261 available results
- Events 43 available results
- Offers 1 available results
- Open Research Data 1047 available results
Chosen catalog filters
Search results for: REPREZENTACJA TEKSTU
-
Ultrasonic wave propagation and digital image correlation measurements of polyolefin fibre-reinforced concrete beams under 3-point bending (beam B-002)
Open Research DataThe DataSet contains the results of the mechanical behaviour of a concrete beam under a 3-point bending test. The beams had dimensions 15 x 15 x 70 cm3. The beam B-Con was made of concrete without fibres (as the reference beam), while beams B-002, B-004, and B-006 were manufactured from the concrete mix containing 2 kg/m3, 4 kg/m3 and 6 kg/m3 of fibres,...
-
Ultrasonic wave propagation and digital image correlation measurements of polyolefin fibre-reinforced concrete beams under 3-point bending (beam B-Con)
Open Research DataThe DataSet contains the results of the mechanical behaviour of a concrete beam under a 3-point bending test. The beams had dimensions 15 x 15 x 70 cm3. The beam B-Con was made of concrete without fibres (as the reference beam), while beams B-002, B-004, and B-006 were manufactured from the concrete mix containing 2 kg/m3, 4 kg/m3 and 6 kg/m3 of fibres,...
-
Ultrasonic wave propagation and digital image correlation measurements of polyolefin fibre-reinforced concrete beams under 3-point bending (beam B-004)
Open Research DataThe DataSet contains the results of the mechanical behaviour of a concrete beam under a 3-point bending test. The beams had dimensions 15 x 15 x 70 cm3. The beam B-Con was made of concrete without fibres (as the reference beam), while beams B-002, B-004, and B-006 were manufactured from the concrete mix containing 2 kg/m3, 4 kg/m3 and 6 kg/m3 of fibres,...
-
Ultrasonic wave propagation and digital image correlation measurements of polyolefin fibre-reinforced concrete beams under 3-point bending (beam B-006)
Open Research DataThe DataSet contains the results of the mechanical behaviour of a concrete beam under a 3-point bending test. The beams had dimensions 15 x 15 x 70 cm3. The beam B-Con was made of concrete without fibres (as the reference beam), while beams B-002, B-004, and B-006 were manufactured from the concrete mix containing 2 kg/m3, 4 kg/m3 and 6 kg/m3 of fibres,...
-
Results after grinding C45 steel
Open Research DataThe database contains results from nanoindenter, scanning microscope and also X-ray diffractometer. To determine the residual stresses and the size of the crystallites in the ferrite grains in the grinded surface layer, the Williamson Hall analysis of the X-ray diffraction patterns was performed. XRD diffraction patterns were also used to perform a...
-
Measurement of mass flow of viscous liquid through a Cylindrical Orifice under laminar flow (CylOr)
Open Research DataThe data was obtained as part of the project "Measurement of mass flow of viscous liquid through a Cylindrical Orifice under laminar flow (CylOr)", in which flow tests of hydraulic oil through a cylindrical orifice with a thickness of l = 25 mm and a throat b = 0.5 (diameter pipes D = 50 mm, orifice diameter d = 25 mm) on the test stand at the Department...
-
DLC coating in ring-on-ring sliding with water lubrication 10MPa/0.1m/s
Open Research DataWear tests in sliding friction of DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 10MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: WATER. Tribometer: PT-3. Overall test time >15h. The test was augmented by vibration...
-
DLC coating in ring-on-ring sliding with saline solution (0.9% wt.) lubrication 20MPa/0.1m/s
Open Research DataWear tests in sliding friction of DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 20MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: SALINE SOLUTION (0.9% wt.). Tribometer: PT-3. Overall test time >15h. The test was augmented...
-
DLC coating in ring-on-ring sliding with saline solution (0.9% wt.) lubrication 10MPa/0.1m/s
Open Research DataWear tests in sliding friction of DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 10MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: SALINE SOLUTION (0.9% wt.). Tribometer: PT-3. Overall test time >15h. The test was augmented...
-
DLC coating in ring-on-ring sliding with water lubrication 20MPa/0.1m/s
Open Research DataWear tests in sliding friction of DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 20MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: WATER. Tribometer: PT-3. Overall test time >15h. The test was augmented by vibration...
-
DLC coating doped with W in ring-on-ring sliding with water lubrication 20MPa/0.1m/s
Open Research DataWear tests in sliding friction of 1% W (tungsten) doped DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 20MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: WATER. Tribometer: PT-3. Overall test time >15h. The test was...
-
DLC coating doped with W in ring-on-ring sliding with water lubrication 10MPa/0.1m/s
Open Research DataWear tests in sliding friction of 1% W (tungsten) doped DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 10MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: WATER. Tribometer: PT-3. Overall test time >15h. The test was...
-
Acoustic emission signals in concrete beams under 3-point bending (beams #1, #2, #3)
Open Research DataThe DataSet contains the results of the mechanical behaviour of concrete beams with dimensions 40 x 40 x 160 cm3under the 3-point bending. The beams were made of concrete with the following ingredients: cement CEM I 42.5R (330 kg/m3), aggregate 0/2 mm (710 kg/m3), aggregate 2/8 mm (664 kg/m3), aggregate 8/16 mm (500 kg/m3), water (165 kg/m3) and super-plasticizer...
-
Ultrasonic wave propagation, digital image correlation and X-ray micro-computed tomography measurements of concrete during splitting (cube #3)
Open Research DataThe DataSet contains the results of the mechanical behaviour of a concrete cube under the splitting test. The cube had dimensions 70 x 70 x 70 cm3 and was made of concrete with the following ingredients: cement type CEM I 42.5R (330 kg/m3), water (165 kg/m3), aggregate 0/2 mm (710 kg/m3), aggregate 2/8 mm (664 kg/m3), aggregate 8/16 mm (500 kg/m3),...
-
Ultrasonic wave propagation, digital image correlation and X-ray micro-computed tomography measurements of concrete during splitting (cube #1)
Open Research DataThe DataSet contains the results of the mechanical behaviour of a concrete cube under the splitting test. The cube had dimensions 70 x 70 x 70 cm3 and was made of concrete with the following ingredients: cement type CEM I 42.5R (330 kg/m3), water (165 kg/m3), aggregate 0/2 mm (710 kg/m3), aggregate 2/8 mm (664 kg/m3), aggregate 8/16 mm (500 kg/m3),...
-
Ultrasonic wave propagation, digital image correlation and X-ray micro-computed tomography measurements of concrete during splitting (cube #4)
Open Research DataThe DataSet contains the results of the mechanical behaviour of a concrete cube under the splitting test. The cube had dimensions 70 x 70 x 70 cm3 and was made of concrete with the following ingredients: cement type CEM I 42.5R (330 kg/m3), water (165 kg/m3), aggregate 0/2 mm (710 kg/m3), aggregate 2/8 mm (664 kg/m3), aggregate 8/16 mm (500 kg/m3),...
-
Ultrasonic wave propagation, digital image correlation and X-ray micro-computed tomography measurements of concrete during splitting (cube #2)
Open Research DataThe DataSet contains the results of the mechanical behaviour of a concrete cube under the splitting test. The cube had dimensions 70 x 70 x 70 cm3 and was made of concrete with the following ingredients: cement type CEM I 42.5R (330 kg/m3), water (165 kg/m3), aggregate 0/2 mm (710 kg/m3), aggregate 2/8 mm (664 kg/m3), aggregate 8/16 mm (500 kg/m3),...
-
DLC coating doped with W in ring-on-ring sliding with saline solution (0.9% wt.) lubrication 20MPa/0.1m/s
Open Research DataWear tests in sliding friction of 1% W (tungsten) doped DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 20MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: SALINE SOLUTION (0.9% wt.). Tribometer: PT-3. Overall test time >15h....
-
DLC coating doped with W in ring-on-ring sliding with saline solution (0.9% wt.) lubrication 10MPa/0.1m/s
Open Research DataWear tests in sliding friction of 1% W (tungsten) doped DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 10MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: SALINE SOLUTION (0.9% wt.). Tribometer: PT-3. Overall test time >15h....
-
Validation of polyurethane-wood composites properties
Open Research DataThis study focuses on the development of the PU-WC manufacturing method, the determination of properties of this type of composite, and the indication of its potential application. The mechanical properties of PU-WC were characterized by flexural tests. To determine the thermal properties, dynamic mechanical analysis (DMA) and thermogravimetric analysis...
-
The electrochemical response to Au electrode modification steps towards viral electrochemical immunosensor preparation
Open Research DataThe dataset contains the electrochemical measurements (CV/EIS) carried out for the consecutive steps of the Au electrode functionalization, in separate subfolders, as described. The cyclic voltammetry (CV) was conducted using a Palmsens 4 potentiostat/galvanostat system (Methrom, Autolab, Netherlands) in the standard three-electrode configuration, with...
-
Wear in siding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specim. sets #20-#21, #22-#23, #24-#25, #26-#27, #28-#29,#30 - #31. Run time: 4-8h.
Open Research DataWear in sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer.Running time: 4-8h.Specimen sets:Specim. sets (# [upper, rotating] - #[lower, non-rotating]):#20-#21, #22-#23, #24-#25, #26-#27,...
-
Wear in siding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specim. sets #20-#21, #22-#23, #24-#25, #26-#27, #28-#29,#30 - #31. Run time: 0-4h.
Open Research DataWear in sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer.Running time: 0 - 4h.Specimen sets:Specim. sets (# [upper, rotating] - #[lower, non-rotating]):#20-#21, #22-#23, #24-#25, #26-#27,...
-
The electrochemical response to glassy carbon electrode modification steps towards viral electrochemical immunosensor preparation
Open Research DataThe dataset contains the electrochemical measurements (CV/EIS) carried out for the consecutive steps of the glassy carbon GC electrode functionalization, in separate subfolders, as described. The cyclic voltammetry (CV) was conducted using a Palmsens 4 potentiostat/galvanostat system (Methrom, Autolab, Netherlands) in the standard three-electrode configuration,...
-
Evaluation of antimicrobial activity of porous composites based on chitosan/poly (vinyl alcohol)
Open Research DataThe dataset contains the results of microbiological tests of composite porous materials whose activity was assessed for their ability to reduce the number of Escherichia coli and Staphylococcus aureus strain, representing the Gram (-) and Gram (+) bacteria, respectively.
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen AMA1-MIC3-ROP1
Open Research DataThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen SAG1-SAG2-GRA7
Open Research DataThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen SAG1-SAG2-AMA1F
Open Research DataThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen SAG1-SAG2-P35
Open Research DataThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen SAG1-SAG2-GRA9
Open Research DataThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen SAG1-SAG2-GRA6
Open Research DataThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen SAG1-SAG2-MIC1L
Open Research DataThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen SAG1-SAG2-GRA1
Open Research DataThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen SAG1-SAG2-MAG1L
Open Research DataThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen SAG1-SAG2-LDH2
Open Research DataThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen SAG1-SAG2-MIC3
Open Research DataThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen SAG1-SAG2-ROP1
Open Research DataThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen SAG1-SAG2-AMA1
Open Research DataThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen SAG1-SAG2-GRA5
Open Research DataThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen SAG1-SAG2-GRA2
Open Research DataThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Measurements of drive system properties of the "Magnetic SpeedLine" ultra-fast robot prototype for IML labeling
Open Research DataTests of the drive system of the ultra-fast robot "SpeedLine magnetic" for labeling with the IML method were carried out in order to analyze the influence of the operating parameters of the drive system on the correctness and quality of the drive system.
-
API 5L X65 steel - tensile properties in room temperature -10°C, along rolling direction
Open Research DataSteel designated as API 5L X65 is often used for oil and gas transportation pipelines. It is caused due to its high ductility, weldability and good corrosion resistance. API 5L X65 is a low alloy steel with carbon content less than 0.3% (depends on delivery condition). Once installed, a pipeline remains in place for many years. Throughout its life,...
-
API 5L X65 steel - CMOD-force record in -10°C, along rolling direction
Open Research DataSteel designated as API 5L X65 is often used for oil and gas transportation pipelines. It is caused due to its high ductility, weldability and good corrosion resistance. API 5L X65 is a low alloy steel with carbon content less than 0.3% (depends on delivery condition). Once installed, a pipeline remains in place for many years. Throughout its life,...
-
API 5L X65 steel - tensile properties in room temperature +20°C, across rolling direction
Open Research DataSteel designated as API 5L X65 is often used for oil and gas transportation pipelines. It is caused due to its high ductility, weldability and good corrosion resistance. API 5L X65 is a low alloy steel with carbon content less than 0.3% (depends on delivery condition). Once installed, a pipeline remains in place for many years. Throughout its life,...
-
API 5L X65 steel - tensile properties in room temperature -10°C, across rolling direction
Open Research DataSteel designated as API 5L X65 is often used for oil and gas transportation pipelines. It is caused due to its high ductility, weldability and good corrosion resistance. API 5L X65 is a low alloy steel with carbon content less than 0.3% (depends on delivery condition). Once installed, a pipeline remains in place for many years. Throughout its life,...
-
API 5L X65 steel - CMOD-force record in -10°C, across rolling direction
Open Research DataSteel designated as API 5L X65 is often used for oil and gas transportation pipelines. It is caused due to its high ductility, weldability and good corrosion resistance. API 5L X65 is a low alloy steel with carbon content less than 0.3% (depends on delivery condition). Once installed, a pipeline remains in place for many years. Throughout its life,...
-
API 5L X65 steel - tensile properties in room temperature +20°C, along rolling direction
Open Research DataSteel designated as API 5L X65 is often used for oil and gas transportation pipelines. It is caused due to its high ductility, weldability and good corrosion resistance. API 5L X65 is a low alloy steel with carbon content less than 0.3% (depends on delivery condition). Once installed, a pipeline remains in place for many years. Throughout its life,...
-
Wear in siding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specim. sets #20-#21, #22-#23, #24-#25, #26-#27, #28-#29,#30 - #31. Run time: 0-4h. High frequency burst recording.
Open Research DataWear in sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer. High frequency burst recording.Running time: 0 - 4h.Specimen sets:Specim. sets (# [upper, rotating] - #[lower, non-rotating]):#20-#21,...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen SAG1-SAG2-MAG1S
Open Research DataThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen AMA1-MIC1-MIC3
Open Research DataThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...