Filters
total: 2629
filtered: 1501
-
Catalog
- Publications 1501 available results
- Journals 16 available results
- Conferences 1 available results
- Publishing Houses 1 available results
- People 112 available results
- Inventions 1 available results
- Projects 9 available results
- Laboratories 2 available results
- Research Equipment 7 available results
- e-Learning Courses 43 available results
- Events 5 available results
- Open Research Data 931 available results
Chosen catalog filters
displaying 1000 best results Help
Search results for: contactless ecg
-
Electrodes array for contactless ECG measurement of a bathing person - a sensitivity analysis
PublicationAn applicability of a remote (contactless) electrocardiogram (ECG) measurements in a bathtub is presented in the paper. Possibility of ECG measurements in shallowly filled tube with a water was examined. A bathing person was, both, sitting and lying during experiments performed. The problem became non-trivial when the bathing person was moving in reference to a fixed set of electrodes and located at the longer walls of the bathtub....
-
A nanoscaled contactless thermometer for biological systems
Publication -
Contactless hearing aid designed for infants
PublicationIt is a well known fact that language development through home intervention for a hearing-impaired infant should start in the early months of a newborn baby's life. The aim of this paper is to present a concept of a contactless digital hearing aid designed especially for infants. In contrast to all typical wearable hearing aid solutions (ITC, ITE, BTE), the proposed device is mounted in the infant's bed with any parts of its set-up...
-
Towards Contactless, Hand Gestures-Based Control of Devices
PublicationGesture-based intuitive interactions with electronic devices can be an important part of smart home systems. In this paper, we adapt the contactless linear gesture sensor for the navigation of smart lighting system. Set of handled gestures allow to propose two methods of active light source selection, continuous dimming, and turning on and off based on discrete gestures. The average gesture recognition accuracy was 97.58% in the...
-
The control of the contactless hybrid short-cicruit current limiter
PublicationPrzedstawiono podstawowe zasady sterowania praca bezstykowego ogranicznika prądów zwarciowych. Dokonano analizy czynników wpływających na poprawną pracę bezstykowego ohranicznik aprądów zwarciowych ze szczególnym uwzględnieniem poprawy jakosci energii elektrycznej poprzez eliminację zapadów napiecia.
-
Optimal ECG lead for deriving respiratory signal
PublicationEDR is an interesting measuring technique that allows an indirect assessment of respiratory activity. This is an alternative solution to direct methods that are based on the measurement of air flow, which require a specialized sensor or even a system. However, due to inter-personal anatomical differences, the optimal ECG lead (placement of the electrodes) ensuring the best EDR signal quality is not fixed. An influence of ECG lead...
-
Smart Weighing Scale with Feet-Sampled ECG
PublicationIn a smart home, health and well-being monitoring systems could be embedded in everyday devices providing a pervasive care. A home bathroom scale is an example of such a device, typically used to measure body weight and very often its composition (e.g. body water/fat percentage). In this paper, we analyzed a potential use of the bathroom scale to measure electrocardiogram (ECG) from electrodes located on the scale's tile. In particular...
-
Estimation of electrode contact in capacitive ECG measurement
PublicationIn the paper a method of electrode’s contact estimation in capacitive electrocardiogram (CECG) is presented. Proposed solution allows estimation of contact quality for each individual electrode. This enables construction of multi-electrode CECG systems, where electrode pairs can be selected on the basis of the individual electrode contact quality.
-
A body position influence on ECG derived respiration
PublicationAn influence of a human body position on ECG derived respiration (EDR) signal is presented in the paper. Examinations were performed during deep, suspended and normal breathing for eight people in four different body positions. EDR and thoracic impedance signals were compared using correlation and standard deviation coefficients. Obtained results have shown that it is possible to monitor breath activity of people being in different...
-
Voltage dips reducyion with a hybrid contactless short circuit limiter.
PublicationW artykule przedstawiono działanie bezstykowego ogranicznika prądów zwarciowych w oparciu o symulację komputerową. Szczególną uwagę zwrócono na możliwość poprawy jakości dostarczanej energii, poprzez ograniczenia trwania zapadów napięcia w sieci elektroenergetycznej, dzięki zastosowaniu wyłącznika hybrydowego. Modelowanie matematyczne wykonano w programie MATLAB i PSPICE.
-
Effect of hybrid contactless short-cicruit limiters on power quality
PublicationPrzedstawiono działanie bezstykowego ogranicznika prądów zwarciowych w oparciu o symulację komputerową. Szczególną uwagę zwrócono na problem jakości dostarczanej energii elektrycznej poprzez ograniczanie zapadów napięcia za pomocą bezstykowego ogranicznika prądów zwarciowych. W modelowaniu elementów systemu elektroenergetycznego i zapadów napięcia, będących skutkiem zwarć wykorzystano program MATLAB z biblioteką Power System Blockset....
-
ECG-based prediction of ventricular fibrillation by means of the PCA
PublicationA Sudden Cardiac Death (SCD) is a death resulting from cardiac failure with no significant symptoms earlier than one hour before occurrence. It is the cause of for approximately 400000 deaths per year in United States and millions of deaths worldwide. The proposed system, including two-stage algorithm and wearable diagnostic device allows for SCD risk estimation and continuous monitoring of high risk patients. A single channel...
-
Capacitively coupled ECG measurements - a CMRR circuit improvement
PublicationA typical galvanic-connected electrocardiogram (ECG) measurement system utilizes two signal’s electrodes and a third one in driven-right-leg (DRL) circuit for improving a common-mode rejection ratio(CMRR) of the acquisition system. In capacitive-coupled ECG similar techniques are used, however it is expected, that the utilized DRL subsystem is formed using a capacitive coupling approach, too. An improvement of the acquisition system...
-
A scale with ECG measurements capability for home cardiac monitoring
PublicationPresented device -a scale developed for enabling extra measurements, in addition to body weight and composition, the electrical activity of the heart (electrocardiogram - ECG) and the level of oxygen saturation in the blood SaO2. Electrical activity is recorded in the form of six leads, socalled - limb leads. The device allows measurement of all standard limb leads and without the need for additional procedures. ECG, although the...
-
Effect of contactless hybrid current limiter on voltage dips in power system
PublicationW referacie przedstawiono działanie hybrydowego niskonapięciowego ogranicznika prądu zwarciowego, składającego się z ultraszybkiego bezpiecznika, tranzystora mocy i warystora. W szczególności omówiono możliwości polepszenia jakości dostarczanej do odbiorców energii elektrycznej. Zastosowanie hybrydowego ogranicznika prądu znacznie ogranicza czasy trwania zapadów napięcia w systemie elektroenergetycznym. Obliczenia wykonano przy...
-
Effect of contactless hybrid current limiter on voltage dips in power system.
PublicationW referacie przedstawiono działanie hybrydowego niskonapięciowego ogranicznika prądu zwarciowego, składającego się z ultraszybkiego bezpiecznika, tranzystora mocy i warystora. W szczególności omówiono możliwości polepszenia jakości dostarczanej do odbiorców energii elektrycznej. Zastosowanie hybrydowego ogranicznika prądu znacznie ogranicza czasy trwania zapadów napięcia w systemie elektroenergetycznym. Obliczenia wykonano przy...
-
A New Coupler Concept for Contactless High-Speed Data Transmission Monitoring
PublicationThis paper presents a new concept of a couplerthat can be applied to high-speed data transmission contactlessmeasurements. The proposed approach is dedicated for differentialsignal transmission monitoring in microstrip coupled lineson printed circuit boards (PCBs). The coupler, produced on aseparate PCB, is overlayed on the transmission line with thedifferential signal and delivers decoupled differential signal tothe main measurement...
-
The contactless method of chip-to-chip high-speed data transmission monitoring
PublicationThis paper presents a technique of decoupling differential signals transmitted in a pair of microstrip lines on a printed circuit board (PCB), using dedicated coupler for high speed data transmission monitoring in chip-to-chip interconnections. The coupler used for signal probing is overlayed on the pair of microstrip lines under test, and provides a signal to the next blocks of the measurement system without disturbing transmission...
-
Control system for contactless electrical energy transfer with varying air gap
PublicationInductive power transfer (IPT) is a system by which electrical energy may be transmitted without electrical connection through a large air gap between coils. Systems usually considered in the literature are the ones with a constant air gap. The paper describes the analysis of IPT, which allows for supplying an electrical load in the conditions of slow, in relation to the dynamics of power supply, changes in the dimensions of the...
-
Binocular Vision Impairments Therapy Supported By Contactless Eye-gaze Tracking System
PublicationBinocular vision impairments often result in partial or total loss of stereoscopic vision. The lack of binocular vision is a serious vision impairment that deserves more attention. Very important result of the binocular vision impairments is a binocular depth perception. This paper describes also a concept of a measurement and therapy system for the binocular vision impairments by using eye-gaze tracking system.
-
Influence of the method of the control of the hybrid contactless short-circuit limiter on power quality
PublicationW artykule przedstawiono wpływ sterowania bezstykowego ogranicznika prądów zwarciowych na ograniczanie zapadów napięcia. Scharakteryzowano podstawowe własności ogranicznika oraz układu sterowania jego pracą. Ponieważ prąd zwarciowy jest detekowany przez dedykowany superkrótki bezpiecznik sterowanie musi być dostosowane do czasu przedrukowego i łukowego topika, które zależą od aktualnej wartości prądu i aktualnej konfiguracji obwodu....
-
Non-Contact Monitoring of ECG in the Home Environment—Selecting Optimal Electrode Configuration
PublicationCapacitive electrocardiography (cECG) is most often used in wearable or embedded measurement systems. The latter is considered in the paper. An optimal electrocardiographic lead, as an individual feature, was determined based on model studies. It was defined as the possibly highest value of the R-wave amplitude measured on the back of the examined person. The lead configuration was also analyzed in terms of minimizing its susceptibility...
-
Improving Accuracy of Contactless Respiratory Rate Estimation by Enhancing Thermal Sequences with Deep Neural Networks
PublicationEstimation of vital signs using image processing techniques have already been proved to have a potential for supporting remote medical diagnostics and replacing traditional measurements that usually require special hardware and electrodes placed on a body. In this paper, we further extend studies on contactless Respiratory Rate (RR) estimation from extremely low resolution thermal imagery by enhancing acquired sequences using Deep...
-
APPLICATION OF STATISTICAL FEATURES AND MULTILAYER NEURAL NETWORK TO AUTOMATIC DIAGNOSIS OF ARRHYTHMIA BY ECG SIGNALS
PublicationAbnormal electrical activity of heart can produce a cardiac arrhythmia. The electrocardiogram (ECG) is a non-invasive technique which is used as a diagnostic tool for cardiac diseases. Non-stationarity and irregu- larity of heartbeat signal imposes many difficulties to clinicians (e.g., in the case of myocardial infarction arrhythmia). Fortunately, signal processing algorithms can expose hidden information within ECG signal contaminated...
-
DETECTION OF BREATHING AND HEART RATE USING AN ECG SIGNAL MEASURED WHILE BATHING IN THE BATHTUB
PublicationNowadays a new area of interest is gaining importance - it is home biomedical examination. Intelligent home can be supported by set of devices for habitants observation. It can be particularly useful for elders or person with some health risks but living alone. One of critical locations within the house is bathroom. One of utilities in the bathroom is a bathtub which is sometimes preferred over shower. There are reports of problems...
-
Energy Efficiency Analysis of Railway Turnout Heating With a Simplified Snow Model Using Classical and Contactless Heating Method
PublicationElectrical heating of railway turnouts is a considerable technical and economic challenge, hence the need to conduct research for optimisation of a railway turnouts heating system. This paper presents results of a numerical analysis and experimental research on heating systems mounted on rail turnouts in line with the classical method and including a heater thermally insulated from the base of a rail. The numerical calculations...
-
Determination of fluoroacetate and fluoride in blood serum by capillary zone electrophoresis using capacitively coupled contactless conductivity detection
Publication -
Entropy Measures of heart rate variability for short ECG datasets in patients with congestive heart failure
PublicationWe investigated the usefulness of entropy measures calculated for short ECG series in distinguishing healthy subjects from patients with congestive heart failure (CHF). Four entropy measures were tested: Approximate Entropy (ApEn), Sample Entropy (SampEn), Fuzzy Entropy (Fuzzy En) and Permutation Entropy (PE), each computed for ECG series of 1000, 500, 250 and 100 RR intervals. We found that with a reduction of the data set length...
-
Entropy measures of heart rate variability for short ECG datasets in patients with congestive heart failure
PublicationWe investigated the usefulness of entropy measures calculated for short ECG series in distinguishing healthy subjects from patients with congestive heart failure (CHF). Four entropy measures were tested: Approximate Entropy (ApEn), Sample Entropy (SampEn), Fuzzy Entropy (FuzzyEn) and Permutation Entropy (PE), each computed for ECG series of 1000, 500, 250 and 100 RR intervals. We found that with a reduction of the data set length...
-
Asymmetric Properties of the Heart Rate Microstructure in Healthy Adults during 48 h ECG Recordings
Publication -
Simultaneous determination of creatinine and acetate by capillary electrophoresis with contactless conductivity detector as a feasible approach for urinary tract infection diagnosis
Publication -
Fully Automated AI-powered Contactless Cough Detection based on Pixel Value Dynamics Occurring within Facial Regions
PublicationIncreased interest in non-contact evaluation of the health state has led to higher expectations for delivering automated and reliable solutions that can be conveniently used during daily activities. Although some solutions for cough detection exist, they suffer from a series of limitations. Some of them rely on gesture or body pose recognition, which might not be possible in cases of occlusions, closer camera distances or impediments...
-
Joint Analysis of National Eco-Efficiency, Eco-Innovation and SDGs in Europe: DEA Approach
PublicationThe growing complexity and intertwining of different socio-economic issues both in individual countries and internationally mean that single-theme analyses do not consider all the relationships and thus have cognitive limitations. Therefore, studies that combine several research areas are increasingly common in the literature to clarify the connections and relationships. In this study, considering the sequential nature of the...
-
JOINT ANALYSIS OF NATIONAL ECO-EFFICIENCY, ECO-INNOVATION AND SDGS IN EUROPE: DEA APPROACH
Publication -
Blood Pressure Estimation Based on Blood Flow, ECG and Respiratory Signals Using Recurrent Neural Networks
PublicationThe estimation of systolic and diastolic blood pressure using artificial neural network is considered in the paper. The blood pressure values are estimated using pulse arrival time, and additionally RR intervals of ECG signal together with respiration signal. A single layer recurrent neural network with hyperbolic tangent activation function was used. The average blood pressure estimation error for the data obtained from 21 subjects...
-
A comprehensive survey on low-cost ECG acquisition systems: Advances on design specifications, challenges and future direction
Publication -
A comprehensive survey on low-cost ECG acquisition systems: Advances on design specifications, challenges and future direction
PublicationAvailability of low-cost, reliable, and portable Electrocardiography (ECG) devices is still very important in the medical world today. Despite the tremendous technological advancement, Cardiovascular Diseases (CVDs) remain a serious health burden claiming millions of lives on an annual basis globally. This is more prevalent in Low and Middle-Income Countries (LMICs) where there are huge financial instability and lack of critical...
-
Techniki śródoperacyjnego monitorowania EKG
PublicationZ badania EKG lekarze uzyskują szereg cennych informacji niezbędnych do prawidłowego podejmowanie ważnych decyzji terapeutycznych. EKG stało się pierwszym parametrem monitorowanym standardowo i w sposób ciągły podczas znieczulenia. Współczesna technika umożliwia nie tylko ciągłe monitorowanie zapisu EKG, a także transmisję danych on-line do dowolnego miejsca w szpitalu, i ich cyfrową rejestrację. Najistotniejszym kryterium przydatności...
-
Contactless Hearing Aid for Infants Employing Signal Processing Algorithms. [Bezkontaktowy aparat słuchowy dla niemowląt wykorzystujący algorytmy przetwarzania sygnału]
PublicationZaprojektowany bezkontaktowy aparat słuchowy umiejscawiany jest w łóżeczku niemowlęcia. Aparat składający się z matrycy 4 mikrofonów oraz prototypowej karty z procesorem DSP pracuje w polu swobodnym. Przetworzony sygnał mowy emitowany jest z wykorzystaniem miniaturowych głośników. Opracowane algorytmy pozwalają na elminację akustycznych sprzężeń zwrotnych, które mogą wystepować ze względu na niewielką odległość mikrofonów od głośników...
-
Balance recognition on the basis of EEG measurement.
PublicationAlthough electroencephalography (EEG) is not typically used for verifying the sense of balance, it can be used for analysing cortical signals responsible for this phenomenon. Simple balance tasks can be proposed as a good indicator of whether the sense of balance is acting more or less actively. This article presents preliminary results for the potential of using EEG to balance sensing....
-
Heart Rate Asymmetry, Its Compensation, and Heart Rate Variability in Healthy Adults during 48-h Holter ECG Recordings
Publication -
Metody redukcji artefaktów w zapisie EEG.
PublicationPrzegląd i opis metod badania EEG jego uwarunkowań technicznych oraz problemy z tym związane. Dokonano przeglądu metod pozwalających na zredukowanie bądź eliminacje artefaktów w zapisie EEG.
-
Jednokanałowy rejstrator EKG z transmisją radiową.
PublicationW referacie zaprezentowano jednokanałowy rejestrator EKG z możliwością przesyłania pomiarów do komputera PC za pomocą transmisji radiowej. Dzięki zastosowaniu układów o niskim poborze mocy, oraz mikrokonwertera ADuC812 otrzymano urządzenie charakteryzujące się dobrymi parametrami pomiarowymi, przy niewielkiej komplikacji układowej i małym poborze prądu. Zastosowanie gotowych modułów teletransmisyjnych uprościło konstrukcję...
-
Arm EMG Wavelet-Based Denoising System
PublicationThese paper presents research results of muscle EMG signal denoising. In the same time two muscles were examined - an adductor muscle (biceps brachii) and an abductor muscle (tricpeps brachii). The EMG signal was filtered using the wavelet transform technique, having selected the crucial parameters as: wavelet basis function (Daubechies 4), 10 th decomposition level, threshold selection algorithm (Heurestic) and a sln rescaling...
-
Tensor Decomposition for Imagined Speech Discrimination in EEG
PublicationMost of the researches in Electroencephalogram(EEG)-based Brain-Computer Interfaces (BCI) are focused on the use of motor imagery. As an attempt to improve the control of these interfaces, the use of language instead of movement has been recently explored, in the form of imagined speech. This work aims for the discrimination of imagined words in electroencephalogram signals. For this purpose, the analysis of multiple variables...
-
Labeler-hot Detection of EEG Epileptic Transients
PublicationPreventing early progression of epilepsy and sothe severity of seizures requires effective diagnosis. Epileptictransients indicate the ability to develop seizures but humansoverlook such brief events in an electroencephalogram (EEG)what compromises patient treatment. Traditionally, trainingof the EEG event detection algorithms has relied on groundtruth labels, obtained from the consensus...
-
Bezstykowe zródła zasilania alternatywš przekazywania energii elektrycznej. - Tł. z Plant Engineering. - Tyt. oryg.: Contactless energy transfer: mobile power on the go
PublicationW artykule podano rozwišzania techniczne bezstykowego przenoszenia energii elektrycznej o mocy nawet do 16 kW w systemach zasilania. W komentarzu zestawiono szczegółowe dane mocy i sprawnoci kilku rozwišzań bezstykowych ródeł zasilania.
-
GROWTH AND STRUCTURAL CHANGES IN TRANSITION COUNTRIES: THE CHICKEN OR THE EGG?
PublicationThe objective of this study is to test empirically the relationship between structural changes (changes in gross value added and employment) and economic growth. We used a panel Granger-causality analysis based on annual data for eight transition countries, covering the period 1995–2011. The main finding is that the causality relations analysed are heterogeneous processes and are identified more often...
-
Expression of hCG and GnRHs and Their Receptors in Endometrial Carcinoma and Hyperplasia
Publication -
Entropy analysis of surface EMG for classification of face movements
Publication