Filters
total: 927
-
Catalog
Search results for: DRAE ADHESIN
-
The Effect of Pt-type Catalysts on Self-adhesive Properties of Silicone Pressure-sensitive Adhesives
Publication -
Enhancing the Seismic Resistance of Columns by GFRP Confinement Using Flexible Adhesive-Experimental Study
PublicationIn this paper, the results of two experiments, focused on testing the effectiveness of a method of enhancing the seismic (dynamic) resistance of masonry columns with the use of flexible polymer adhesive, are shown. The first experiment was devoted to investigate the damping properties of a polymer working between two stiff layers, whereas the aim of the second one was to verify if the identified damping properties of the polymer...
-
Failure Monitoring and Condition Assessment of Steel-Concrete Adhesive Connection Using Ultrasonic Waves
PublicationAdhesive bonding is increasingly being incorporated into civil engineering applications. Recently, the use of structural adhesives in steel-concrete composite systems is of particular interest. The aim of the study is an experimental investigation of the damage assessment of the connection between steel and concrete during mechanical degradation. Nine specimens consisted of a concrete cube and two adhesively bonded steel plates...
-
Wave Frequency Effects on Damage Imaging in Adhesive Joints Using Lamb Waves and RMS
PublicationStructural adhesive joints have numerous applications in many fields of industry. The gradual deterioration of adhesive material over time causes a possibility of unexpected failure and the need for non-destructive testing of existing joints. The Lamb wave propagation method is one of the most promising techniques for the damage identification of such connections. The aim of this study was experimental and numerical research on...
-
The Idea of Using Adhesive Bonds in Shaping of Cold-formed Thin-walled Beam-columns
PublicationThe chapter concerns the idea of using adhesive bonds in the shaping of cold-formed thin-walled beam-columns. The idea of adhesive-bonded connections is not new but is unlikely to have been used in the design and shaping of thin-walled beam-columns in civil engineering up to date. Metal bar structures, including (due to economic reasons) thin-walled structures, are the most common and effective means to build engineering superstructures/loadbearing...
-
Fatal sepsis in a pregnant woman with pyelonephritis caused by Escherichia coli bearing Dr and P adhesins: diagnosis based on postmortem strain genotyping
PublicationW pracy został opisany pierwszy śmiertelny przypadek młodej kobiety w ciąży z powodu przewlekłego zapalenia odmiedniczkowego nerek spowodowany przez szczepy E. coli z fimbriami typu Dr + i P. Badania pośmiertne wykazały, że śmierć nastąpiła z powodu posocznicy do której doszło na skutek zakażenia szczepami E. coli Dr + . Odmiedniczkowe zapalenie nerek w ciąży jest związane z wieloma powikłaniami, w tym ograniczeniem wzrostu płodu,...
-
Wave energy attenuation in fields of colliding ice floes – Part 1: Discrete-element modelling of dissipation due to ice–water drag
Publication -
Influence of Illite and Its Amine Modifications on the Self-Adhesive Properties of Silicone Pressure-Sensitive Adhesives
Publication -
Influence of diatomite and its base modifications on the self-adhesive properties of silicone pressure-sensitive adhesives
Publication -
Carboxymethylated starch and cellulose derivatives-based film as human skin equivalent for adhesive properties testing
Publication -
Development and Characterization of Silicone Pressure-Sensitive Adhesives Modified Sepiolite for Self-Adhesive Tape Applications
Publication -
Fracture Surface Topography Parameters for S235JR Steel Adhesive Joints After Fatigue Shear Testing
PublicationThis paper presents the experimental results of a study investigating the effect of holes and notches made on the overlap ends on the strength of adhesive joints. Single-lap joints made of S235JR steel sheets bonded with Araldite 2024-2 epoxy adhesive were tested. For comparative reasons, static shear strength tests and high-cycle fatigue strength tests were performed. Adhesive-filled joints having three holes, each with a diameter...
-
Double layer adhesive silicone dressing as a potential dermal drug delivery film in scar treatment
PublicationThe present studies focused on the evaluation of design of an adhesive silicone film intended for scar treatment. Developed silicone double layer film was examined in terms of its future relevance to therapy and applicability on the human skin considering properties which included in vitro permeability of water vapor and oxygen. In order to adapt the patches for medical use in the future there were tested such properties as...
-
Double layer adhesive silicone dressing as a potential dermal drug delivery film in scar treatment
Publication -
Biochemical characteristic of biofilm of uropathogenic Escherichia coli Dr+ strains.
PublicationUrinary tract infections caused by Escherichia coli are very common health problem in the developed countries. The virulence of the uropathogenic E. coli Dr+ IH11128 is determined by Dr fimbriae, which are homopolymeric structures composed of DraE subunits with the DraD protein capping the fiber. In this study, we have analyzed the structural and biochemical properties of biofilms developed by E. coli strains expressing Dr fimbriae...
-
Comparative genomics and functional analysis of a highly adhesive dairy Lactobacillus paracasei subsp. paracasei IBB3423 strain
Publication -
Microscopic and Spectroscopic Imaging and Thermal Analysis of Acrylates, Silicones and Active Pharmaceutical Ingredients in Adhesive Transdermal Patches
PublicationDermal or transdermal patches are increasingly becoming a noteworthy alternative ascarriers for active pharmaceutical ingredients (APIs), which makes their detailed physicochemical evaluation essential for pharmaceutical development. This paper demonstrates mid-infrared (FTIR) and Raman spectroscopy with complementary microscopic methods (SEM, optical and confocal Raman microscopy) and differential scanning calorimetry...
-
Microscopic and Spectroscopic Imaging and Thermal Analysis of Acrylates, Silicones and Active Pharmaceutical Ingredients in Adhesive Transdermal Patches
Publication -
Effect of the Concentration of Hop Cone Extract on the Antibacterial, Physico-Chemical and Functional Properties of Adhesive Toilet Cleaners
Publication -
Evaluation of the resistance of steel–concrete adhesive connection in reinforced concrete beams using guided wave propagation
PublicationThe development of the nondestructive diagnostic methods is of significant importance in the last decades. A special attention is paid to diagnostics of reinforced concrete structures, which are very popular in the civil engineering field. A possible use of the guided waves in the estimation of the resistance of steel–concrete adhesive connection is studied in the following paper. The relationships relating adhesive connection...
-
Genes Involved in the Processes of Cell Proliferation, Migration, Adhesion, and Tissue Development as New Potential Markers of Porcine Granulosa Cellular Processes In Vitro: A Microarray Approach
Publication -
Genes responsible for proliferation, differentiation, and junction adhesion are significantly up-regulated in human ovarian granulosa cells during a long-term primary in vitro culture
Publication -
“Biological Adhesion” is a Significantly Regulated Molecular Process during Long-Term Primary In Vitro Culture of Oviductal Epithelial Cells (Oecs): A Transcriptomic and Proteomic Study
Publication -
The role of uropathogenic Escherichia coli adhesive molecules in inflammatory response- comparative study on immunocompetent hosts and kidney recipients
Publication -
Evaluation of adhesive forces and the specific surface energy of zirconia stabilized by yttria with alumina additions ceramic by AFM method
PublicationThe adhesive forces and the specific surface energy of ceramic material surfaces are very important for further tribological and biomedical applications of ceramics. Partially stabilized zirconia (zirconium oxide) is popular for manufacturing various medical products. ZrO2 stabilized by Y2O3 with additions of 5 wt% alumina was produced by slip casting method with a subsequent sintering. Structure and chemical composition of ceramic...
-
Physical and Mechanical Evaluation of Silicone-Based Double-Layer Adhesive Patch Intended for Keloids and Scar Treatment Therapy
PublicationGrowing interest in silicone elastomers for pharmaceutical purposes is due to both theirbeneficial material effect for scar treatment and their potential as drug carriers. Regarding their morphological structure, silicone polymers possess unique properties, which enable a wide range of applicability possibilities. The present study focused on developing a double-layer adhesive silicone film (DLASil) by evaluating its physical...
-
Physical and Mechanical Evaluation of Silicone-Based Double-Layer Adhesive Patch Intended for Keloids and Scar Treatment Therapy
Publication -
Monitoring of crosslinking of a DGEBA-PAMAM adhesive in composite/aluminium bonded joint using mechanical and ultra-sound techniques
PublicationAdhesive cure is an important and determining aspect of strength and stability of bonded structures. Crosslinking of the polymer leads to the adhesive strength, stiffness and durability. Depending on the resin and curing agent used, cure time can vary from minutes to weeks, even then 100% crosslinking not being guaranteed. Standard methods based on dynamic mechanical analysis (DMA) or calorimetric techniques (DSC, DTA) are valuable...
-
Recent progress in ultra-low formaldehyde emitting adhesive systems and formaldehyde scavengers in wood-based panels: a review
PublicationTraditional wood-based panels are produced with synthetic, formaldehyde-based adhesives, commonly made from fossil-derived constituents, such as urea, phenol, melamine, etc. Along with their numerous advantages, such as chemical versatility, high reactivity and excellent adhesive performance, these adhesives are characterized by certain problems, connected with the hazardous volatile organic compounds (VOCs), mostly free formaldehyde...
-
L1 Cell Adhesion Molecule Overexpression Down Regulates Phosphacan and Up Regulates Structural Plasticity-Related Genes Rostral and Caudal to the Complete Spinal Cord Transection
PublicationL1 cell adhesion molecule (L1CAM) supports spinal cord cellular milieu after contusion and compression lesions, contributing to neuroprotection, promoting axonal outgrowth, and reducing outgrowth-inhibitory molecules in lesion proximity. We extended investigations into L1CAM molecular targets and explored long-distance effects of L1CAM rostral and caudal to complete spinal cord transection (SCT) in...
-
A subset of two adherence systems, acute pro-inflammatory pap genes and invasion coding dra, fim, or sfa, increases the risk of Escherichia coli translocation to the bloodstream
PublicationAn analysis of the phylogenetic distribution and virulence genes of Escherichia coli isolates which predispose this bacteria to translocate from the urinary tract to the bloodstream is presented. One-dimensional analysis indicated that the occurrence of P fimbriae and α-hemolysin coding genes is more frequent among the E. coli which cause bacteremia. However, a two-dimensional analysis revealed that a combination of genes coding...
-
RMS-based damage identification in adhesive joint between concrete beam and steel plate using ultrasonic guided waves
PublicationAdhesive joints have numerous applications in many branches of industry, such as civil engineering, automotive, aerospace and shipbuilding. As with most structural elements, adhesive joints can experience any damage mechanism, which induces the need for diagnostic testing. Ultrasonic waves are widely used for non-destructive inspection of many structures and their elements, including adhesive joints. Guided wave propagation method...
-
Damage imaging algorithm for non-destructive inspection of CFRP/steel adhesive joints based on ultrasonic guided wave propagation
PublicationThe paper concerns assessing the quality of the adhesive connection between a steel plate and the reinforcing CFRP laminate. A three-stage algorithm for non-destructive damage imaging was developed. As the first step, an initial study involving dispersion curves of joint components was executed to determine the material parameters and the appropriate excitation frequency. During the second step, damage identification in three-layer...
-
Experimental study of the impact of notches and holes made in the front edge of adherends on the properties of static and fatigue strength of adhesive joints
PublicationThe paper presents the results of experimental studies aimed at determining the effect of holes and notches at the front edge of adherends on the strength of adhesive joints. Single-lap joints made of S235JR steel sheets joined with Araldite 2014-2 epoxy adhesive were tested. Comparative tests of static strength in the shear test as well as high-cycle fatigue strength tests were carried out. Joints with three holes with a diameter...
-
Female pelvic peritoneal adhesions - Female, 64 - Tissue image [5240730032372671]
Open Research DataThis is the histopathological image of OTHER AN UNSPECIFIED FEMALE GENITAL ORGANS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Female pelvic peritoneal adhesions - Female, 64 - Tissue image [5240730032375901]
Open Research DataThis is the histopathological image of OTHER AN UNSPECIFIED FEMALE GENITAL ORGANS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Female pelvic peritoneal adhesions - Female, 64 - Tissue image [5240730032378531]
Open Research DataThis is the histopathological image of OTHER AN UNSPECIFIED FEMALE GENITAL ORGANS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Female pelvic peritoneal adhesions - Female, 64 - Tissue image [5240730032375041]
Open Research DataThis is the histopathological image of OTHER AN UNSPECIFIED FEMALE GENITAL ORGANS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Statistical radii associated with amino acids to determine the contact map: fixing the structure of a type I cohesin domain in theClostridium thermocellumcellulosome
Publication -
Detection and Imaging of Debonding in Adhesive Joints of Concrete Beams Strengthened with Steel Plates Using Guided Waves and Weighted Root Mean Square
PublicationStrengthening of engineering structures is an important issue, especially for elements subjected to variable loads. In the case of concrete beams or slabs, one of the most popular approaches assumes mounting an external reinforcement in the form of steel or composite elements by structural adhesives. A significant disadvantage of adhesive joints is the lack of access to the adhesive film for visual condition assessment, thus, there...
-
Technology of an adhesive silicone film as drug carrier in transdermal therapy I. Analytical methods used for characterization and design of the universal elastomer layers
PublicationSilicone polymers possess unique properties, which make them suitable for many different applications, for example in the pharmaceutical and medical industry. To create an adhesive silicone film, the appropriate silicone components have to be chosen first. From these components two layers were made: an adhesive elastomer applied on the skin, and a non-adhesive elastomer on the other side of the film. The aim of this study was...
-
Biofilm bakteryjny uropatogennych szczepów E. coli Dr+ jako czynnik indukujący przewlekłość zakażeń dróg moczowych ograniczający ich leczenie
PublicationZakażenia dróg moczowych (ZUM) stanowią jedne z najczęściej występujących infekcji bakteryjnych, dotykających każdego roku miliony osób na świecie. Problematyka tych zakażeń wynika z ich przewlekłości i nawrotów, pomimo stosowania terapii antybiotykowej oraz ciągle wzrastającej lekooporności uropatogenów je wywołujących. Dominującym czynnikiem etiologicznym ZUM są uropatogenne szczepy E. coli (UPECs), wykazujące zdolność do adhezji,...
-
Chimeric Dr fimbriae with a Herpes Simplex virus type 1 epitope as a model for a recombinant vaccine.
PublicationBiałko adhezyny DraE uropatogennych szczepów E. coli Dr+ zostało wykorzystane jako nośnik 11a a determinanty antygenowej glikoproteiny D wirusa HSV ty-pu 1. Sekwencja kodująca epitop HSV została wklonowana do genu draE w obrębie regionu N- terminalnego eksponowanej powierzchniowo domeny 2. Ekspresjachimerycznych białek DraE-HSV została potwierdzona za pomocą mikroskopii immunofluorescencyjnej i elektronowej.
-
Mussel‐inspired biomaterials: From chemistry to clinic
PublicationAfter several billions of years, nature still makes decisions on its own to identify, develop, and direct the most effective material for phenomena/challenges faced. Likewise, and inspired by the nature, we learned how to take steps in developing new technologies and materials innovations. Wet and strong adhesion by Mytilidae mussels (among which Mytilus edulis—blue mussel and Mytilus californianus—California mussel are the most...
-
Beata Zalewska-Piątek dr hab.
People -
Virulence gene profiles in Staphylococcus aureus isolated from cows with subclinical mastitis in eastern Poland
PublicationStaphylococcus aureus is arguably the most important pathogen involved in bovine mastitis. The aim of this study was to determine the virulence gene profiles of 124 Staph. aureus isolates from subclinical mastitis in cows in eastern Poland. The presence of 30 virulence genes encoding adhesins, proteases and superantigenic toxins was investigated by PCR. The 17 different combinations of adhesin genes were identified. Occurrence...
-
Essais de fissuration sur adhésif au moyen d'un essai de clivage en coin instrumente, mise en œuvre et application.
PublicationL'essai de clivage en coin, plus communément appelle 'boeing wedge' test, est une méthode de référence pour qualifier la tenue mécanique a long terme des collages structuraux. Cette technique est particulièrement appréciée de par son faible cout et la simplicité de sa mise en ouevre. Elle consiste a précontraindre la colle en insérant un coin entre deux plaques assembles. L'énergie élastique ainsi stockée dans la structure...
-
Measurements of guided wave propagation in CFRP/steel adhesive joints obtained by scanning laser vibrometry
Open Research DataThe DataSet contains guided wave signals measured in adhesive joints of steel plates (steel of type S355 with a thickness of 11.9 mm ) and carbon fibre reinforced polymer (CarboDur S1012 with a thickness of 1.24 mm). The samples were as follows: #0 – intact; #1 – 10% disbond; #2 – 20% disbond; #3 – 50% disbond; #4 – 80% disbond; #5 – 100% disbond.
-
Effects of electrophoretic deposition times and nanotubular oxide surfaces on properties of the nanohydroxyapatite/nanocopper coating on the Ti13Zr13Nb alloy
PublicationLoad-bearing implants are developed with a particular emphasis placed on an application of ceramic hydroxyapatite coatings in order, to enhance the bioactivity of titanium implants and to shorten the healing time. Therefore, thin, fully crystalline coatings that are, highly adhesive, hydrophilic and demonstrating antibacterial properties are ly looked for. The aim of this research was to develop and characterize the properties...
-
Results of nanoindentation test to calculate residual stress in an eyelet of undercarriage drag strut after laser treatment
Open Research DataIn order to determine the residual stress in the laser-processed an eyelet of undercarriage drag strut, a nanoindentation test was performed before and after stress relief annealing. For this purpose, after the hardness test, the sample was subjected to stress relief annealing at 270 °C for 2 hours. Annealing was performed in a vacuum furnace. Hardness...