Filters
total: 2410
-
Catalog
- Publications 1125 available results
- Journals 24 available results
- People 53 available results
- Inventions 2 available results
- Projects 2 available results
- Research Equipment 1 available results
- e-Learning Courses 9 available results
- Events 5 available results
- Open Research Data 1189 available results
displaying 1000 best results Help
Search results for: ELECTROMAGNETIC%20CLOAKINGWAVE%20PROPAGATIONMAXWELL%E2%80%99S%20EQUATIONSFRACTIONAL%20CALCULUS
-
Accurate Modeling of a Lossy Ferrite Circular Guide Section Magnetized Through a Rotary Four-Pole Magnetic Field
PublicationKorzystając z metody rodzajów sprzężonych opracowano model matematyczny umożliwiający określenie parametrów falowych i rozkładów pola em. fal występujących w ferrytowym falowodzie cylindrycznym magnesowanym czterobiegunowym polem magnetycznym. W oparciu o model określono macierz rozproszenia sekcji falowodu. Opracowane oprogramowanie pozwoliło na zbadanie charakterystyk częstotliwościowych sekcji ferrytowej i wskazanie możliwości...
-
Variable Order Differential Models of Bone Remodelling * *This work was supported by FCT, through IDMEC, under LAETA, projects UID/EMS/50022/2013, BoneSys, joint Polish-Portuguese project Modelling and controlling cancer evolution using fractional calculus, PERSEIDS (PTDC/EMS-SIS/0642/2014) and IF/00653/2012
Publication -
Michał Michna dr hab. inż.
PeopleMichal Michna received the M.Sc. and Ph.D. degrees in electrical engineering from the Gdansk University of Technology (GUT), Gdansk, Poland, in 1998 and 2005, respectively. Since 2004, he was employed at the Department of Power Electronics and Electrical Machines of the Gdańsk University of Technology (assistant, assistant professor, senior lecturer). In 2010-2015 he was a deputy of head of the Department of Power Electronics and...
-
The conducted immunity test of an AC adaptor in accordance with EMC standards
Open Research DataThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the ac adaptor PHILIPS DC power supply SBC 6654. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 150 kHz...
-
Invasive breast carcinoma of no special type - Female, 80 - Tissue image [4120730022888241]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
LYMPH NODES, Obturator lymph node - Male, 80 - Tissue image [6160730013039831]
Open Research DataThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
LYMPH NODES, Ileocolic lymph node - Female, 80 - Tissue image [6110730021445131]
Open Research DataThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
LYMPH NODES, Ileocolic lymph node - Female, 80 - Tissue image [6110730021442271]
Open Research DataThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
LYMPH NODES, Ileocolic lymph node - Female, 80 - Tissue image [6110730021442411]
Open Research DataThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Squamous cell carcinoma, keratinizing, NOS - Male, 80 - Tissue image [630073002827101]
Open Research DataThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 80 - Tissue image [4120730022887961]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
LYMPH NODES, Ileocolic lymph node - Female, 80 - Tissue image [6110730021447491]
Open Research DataThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
LYMPH NODES, Ileocolic lymph node - Female, 80 - Tissue image [6110730021449861]
Open Research DataThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
LYMPH NODES, Obturator lymph node - Male, 80 - Tissue image [6160730013038611]
Open Research DataThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
LYMPH NODES, Ileocolic lymph node - Female, 80 - Tissue image [6110730021447611]
Open Research DataThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 80 - Tissue image [4120730022883271]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
LYMPH NODES, Ileocolic lymph node - Female, 80 - Tissue image [6110730021446331]
Open Research DataThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 80 - Tissue image [4120730022888351]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
OTHER AND UNSPECIFIED URINARY ORGANS, Urethra - Male, 80 - Tissue image [6160730013037641]
Open Research DataThis is the histopathological image of OTHER AND UNSPECIFIED URINARY ORGANS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 80 - Tissue image [4120730022886871]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
LYMPH NODES, Obturator lymph node - Male, 80 - Tissue image [6160730013044911]
Open Research DataThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
OTHER AND UNSPECIFIED URINARY ORGANS, Urethra - Male, 80 - Tissue image [7040347232573121]
Open Research DataThis is the histopathological image of OTHER AND UNSPECIFIED URINARY ORGANS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
LYMPH NODES, Obturator lymph node - Male, 80 - Tissue image [616073001304661]
Open Research DataThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Invasive breast carcinoma of no special type - Female, 80 - Tissue image [4120730022888781]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Alicja Sekuła dr hab. inż.
People- 2017 PhD with “habilitation” of Economics, discipline – finance, Warsaw School of Economics Collegium of Management and Finance, - 2003 Doctor of Economics, discipline – economics, Gdańsk University of Technology, Faculty of Management and Economics; - 1997 Master of Engineering: Gdańsk University of Technology, Faculty of Management and Economics, - 1996 Master of Engineering: Gdańsk University of Technology,...
-
Analiza trwałości zmęczeniowej asfaltów drogowych i modyfikowanych z wykorzystaniem testu liniowego zwiększania amplitudy / Analysis of the fatigue life of neat and modified bitumens using linear amplitude sweep test
PublicationThe paper presents an evaluation of the fatigue resistance of selected Polish bituminous binders: neat bitumen 50/70, polymer modified bitumen PMB 45/80-55 and polymer highly modified bitumen PMB 45/80-80. The linear amplitude sweep (LAS) test, which is a new bitumen performance grading test developed in the USA, and was used to assess the fatigue life of the bitumens. Highly modified bitumen 45/80-80 showed 10-20 times higher...
-
Properties of ordered titanium templates covered with Au thin films for SERS applications
PublicationtCurrently, roughened metal nanostructures are widely studied as highly sensitive Raman scattering sub-strates that show application potential in biochemistry, food safety or medical diagnostic. In this workthe structural properties and the enhancement effect due to surface enhanced Raman scattering (SERS) ofhighly ordered nano-patterned titanium templates covered with thin (5–20 nm) gold films are reported.The templates are formed...
-
EDISOn Electromagnetic Design of fexIble SensOrs
ProjectsProject realized in Department of Microwave and Antenna Engineering according to POIR.04.04.00-00-1DC3/16 (nowy nr umowy); TEAM TECH/2016-1/6 (stary nr umowy) agreement from 2016-12-06
-
Non-Newtonian Mathematics Instead of Non-Newtonian Physics: Dark Matter and Dark Energy from a Mismatch of Arithmetics
PublicationNewtonian physics is based on Newtonian calculus applied to Newtonian dynamics. New paradigms such as ‘modified Newtonian dynamics’ (MOND) change the dynamics, but do not alter the calculus. However, calculus is dependent on arithmetic, that is the ways we add and multiply numbers. For example, in special relativity we add and subtract velocities by means of addition β1⊕β2=tanh(tanh−1(β1)+tanh−1(β2)), although multiplication β1⊙β2=tanh(tanh−1(β1)⋅tanh−1(β2)),...
-
Measurements of radiation emission of a portable power bank with a capacity of 5200 mAh
Open Research DataThe dataset contains the emission measurement results that are part of comprehensive tests carried out for portable power banks with different capacities. The measurements were performed in the frequency range from 30 MHz to 3 GHz using a Gigahertz Transverse Electromagnetic (GTEM) cell. The test setup was configured to measure a portable power bank...
-
Results and models for Novel high frequency components with non-conventional shape employing smooth geometry deformation of 3D solid with FFD
Open Research DataThe project aims to investigate the possibility of developing and manufacturing novel high frequency devices having non-standard geometries, allowing for improved electromagnetic performance over what is achievable with currently available design tools. The non-conventional geometry will be obtained by employing the free-form shape deformation technique...
-
The conducted immunity test of a power supply unit in the frequency range from 19 MHz to 26 MHz for the RF voltage level of 3 V
Open Research DataThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the DF1723003TC NDN power supply unit. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 19 MHz to 26 MHz were...
-
The conducted immunity test of a power supply unit in the frequency range from 19 MHz to 26 MHz for the RF voltage level of 1 V
Open Research DataThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the DF1723003TC NDN power supply unit. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 19 MHz to 26 MHz were...
-
The conducted immunity test of a power supply unit in the frequency range from 19 MHz to 26 MHz for the RF voltage level of 10 V
Open Research DataThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the DF1723003TC NDN power supply unit. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 19 MHz to 26 MHz were...
-
Nuts 43 (voj. lubuskie). Number of accidents, injuries, seriously Injured and fatalities
Open Research DataThe data contains information about the number of accidents, injuries, seriously Injured and fatalities between 1999 and 2019 in months in voj. lubuskie (Poland, nuts 43)
-
Information Processing and Fechner’s Problem as a Choice of Arithmetic
PublicationFechner’s law and its modern generalizations can be regarded as manifestations of alternative forms of arithmetic, coexisting at stimulus and sensation levels. The world of sensations may be thus described by a generalization of the standard mathematical calculus.
-
Fractional Order Dynamic Positioning Controller
PublicationImproving the performance of Dynamic Positioning System in such applications as station keeping, position mooring and slow speed references tracking requires improving the position and heading control precision. These goals can be achieved through the improvement of the ship control system. Fractional-order calculus is a very useful tool which extends classical, integer-order calculus and is used in contemporary modeling and control...
-
OTHER AND UNSPECIFIED MALE GENITAL ORGANS, Vas deferens - Male, 80 - Tissue image [6160730013038061]
Open Research DataThis is the histopathological image of OTHER AND UNSPECIFIED MALE GENITAL ORGANS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
OTHER AND UNSPECIFIED MALE GENITAL ORGANS, Seminal vesicle - Male, 80 - Tissue image [6160730013031691]
Open Research DataThis is the histopathological image of OTHER AND UNSPECIFIED MALE GENITAL ORGANS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
OTHER AND UNSPECIFIED MALE GENITAL ORGANS, Vas deferens - Male, 80 - Tissue image [6160730013036191]
Open Research DataThis is the histopathological image of OTHER AND UNSPECIFIED MALE GENITAL ORGANS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Szkice miasta. Sem. VI GP 2022/2023
e-Learning CoursesSzkic, jako narzędzie poznania architektury i przestrzeni miasta, analizy struktury i relacji przestrzennych oraz sposobów funkcjonowania.
-
WRF-METEOPG: numerical weather forecast data for Poland - Days 99-105, Year 2021
Open Research DataWRF-METEOPG is a numerical weather forecast system developed at the Faculty of Civil and Environmental Engineering, Gdansk University of Technology, Poland. The system was built on the basis of the Weather Research and Forecast model version 4.2 and implemented at Centre of Informatics Tricity Academic Supercomputer & Network. Physics parametrization...
-
Drgania i hałaśliwość silników asynchronicznych - weryfikacja nowych hipotez
PublicationArtykuł zawiera nowe spojrzenie na postaci drgań kadłuba i tarcz silników asynchronicznych wymuszanych siłami elektromagnetycznymi. Omówiono badania postaci drgań własnych i eksploatacyjnych kadłuba i tarcz łożyskowych. Poddano analizie związki przyczynowo-skutkowe postaci drgań tarcz łożyskowych z łożyskami tocznymi i ślizgowymi. Wykazano, że wibracyjne eksploatacyjne odkształcenia tarcz silników klatkowych małej i średniej mocy,...
-
Modification of structured bio‑carbon derived from spongin-based scaffolds with nickel compounds to produce a functional catalyst for reduction and oxidation reactions: Potential for use in environmental protection
PublicationThree different 3D fibrous-like NiO/Ni(OH)2/Ni‑carbonized spongin-based materials were prepared via a simple sorption–reduction method. Depending on the support used, the catalysts were composed of carbon, nickel oxide, nickel hydroxide and zero-valent nickel, with the surface content of the nickel-containing phase in the range 15.2–26.0 wt%. Catalytic studies showed promising activity in the oxidation of phenolic compounds in water...
-
Skorygowana nomenklatura rodników, jonów, jonorodników i podobnych indywi-duów chemicznych. (Zalecenia IUPAC 1993). Z ang. przełożyli: M. Hoffmann, S. Milewski, W. Przychodzeń, T. Sokołowska, D. Witt. Red. nauk. T. Sokołow- ska, A. Wiśniewski. Wrocław: Uniw. Wroc.**2001, 123 s. 4 tab. bibliogr. 21 poz. Biblioteka Wiadomości Chemiczne. Org.: W. H. Powell. Revised nomenclature for radicals, ions, radical ions and related species (IUPAC recommendations 1993). Pure Appl. Chem. vol. 65.
PublicationDokument zawiera reguły tworzenia nazw systematycznych cząstek wymienionychw tytule. Reguł jest 110. Numerowane są od RC-80 do RC-85, z podpunktami.Zastępują one Reguły C-80 do C-85 Nomenklatury Związków Organicznych IUPAC zroku 1979. Reguły są ilustrowane wzorami (ok. 600), którym przypisano nazwęlub nazwy systematyczne.
-
Reverberation chamber in emc tests of naval systems
PublicationPaper covers the techniques of emission and immunity testing to the electromagnetic field in reverberation chamber. The procedure of he chamber calibration and field homogeneity assessment were covered. The naval forces' product as selected as an example for discussing the testing procedure in the chamber. The paper's summary gives the assortment of methodology in radiation emission testing and immunity to the electromagnetic field...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 80 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Etyczne przesłanki teorii ekonomicznych w interpretacji Amartyi Sena. W:Etyczne podstawy ekonomii - teoria i praktyka. Red.nauk. J. Kubka. Gdansk:Zakł. Nauk. Filoz. Wydz. Zarz. i Ekon. P. Gdań.**2003 s. 99-104
PublicationArtykł zawiera prezentację pogladów A.Sena zawartych w pracy ''On Ethics andEconomics''(1987). Uwaga skoncentrowana na krytycznej analizie przez Sena za-łożeń A. Smitha dotyczących relacji etuki i ekonomiki.
-
Modelowanie ryzyka w ruchu drogowym szeregami czasowymi.**2003, 142 s. 48rys. bibliogr. 99 poz. maszyn. Rozprawa doktorska /17.12.2003/. P. Gdań., Wydz. Inż. Ląd. Promotor: prof. dr. hab. inż. Ryszard Krystek.
PublicationW pracy przedstawiono metodę modelowania wielkości ryzyka w ruchu drogowym z wykorzystaniem teorii szeregów czasowych, umożliwiającą wykrywanie i interpretację zmian poziomu bezpieczeństwa ruchu drogowego oraz wnioskowanie o przyszłych tendencjach tych zmian. Na jej podstawie zbudowano modele, dzięki którym możliwe było określenie związku pomiędzy poziomem bezpieczeństwa ruchu drogowego w Polsce, mierzonym liczbą śmiertelnych ofiar...
-
Ryszard Katulski prof. dr hab. inż.
People