Publications
Filters
total: 805
Catalog Publications
Year 2013
-
Investigation of electrocatalytic gas sensor properties in presence of chlorine
PublicationProperties of sensor based on Nasicon with two round shaped platinum electrodes are investigated. Influence of different chlorine concentrations on the sensor response is presented. Measurements in different temperatures have been performed in order to determine optimal sensor working temperature.
-
Investigation of functional layers of solid oxide fuel cell anodes for synthetic biogas reforming
PublicationSolid oxide fuel cells (SOFCs) are one of the most promising energy conversion devices due to their high efficiency, low pollution and fuel flexibility. Unfortunately, when hydrocarbons are used as a fuel, for example in the form of a biogas, solid carbon can deposit on the anode surface. This process leads to the degradation of the fuel cell performance. A possible solution to this problem is to apply an additional catalytic material,...
-
Investigation of sensing mechanism of Nasicon electrocatalytic sensors in nitrogen dioxide and ammonia
PublicationIn this paper a sensing mechanism of Nasicon electrocatalytic sensor in nitrogen dioxide and ammonia is investigated. Both gases are environmentally hazardous and contain nitrogen atom in the molecule. However, it seems that their sensing mechanism in electrocatalytic sensor could be totally different. Namely, the maximum sensitivity for each gas was obtained at different temperatures. Also, different auxiliary layers are formed...
-
IR-THERMAL IMAGING IN CARDIOSURGERY
PublicationA method for monitoring the state of the myocardium during cardiosurgical interventions based on thermal IR imaging is presented. These methods called Static Thermography and Active Dynamic Thermography (ADT) uses information about distribution of temperature on the surface and an external excitation source to induce thermal transient processes in a tested object. Recording time series of thermograms allows to calculate parametric...
-
Klawiatura ekranowa dla osób posługujących się jedną kończyną górną
Publicationrtykuł prezentuje układ symboli na klawiaturze wirtualnej dedykowanej osobom niepełnosprawnym posługującym się jedną kończyną górną. Rozmieszczenie znaków zostało ustalone na podstawie przeprowadzonej analizy częstotliwości występowania poszczególnych liter w języku polskim. Uwzględniono również najczęściej występujące pary liter, a odpowiadające im klawisze ułożono blisko siebie. Zaproponowany kształt klawiatury jest wynikiem...
-
Liniowe i nieliniowe modele wielowymiarowej kalibracji do predykcji stężenia substancji z pomiarów woltamperometrycznych
PublicationPomiary woltamperometryczne znajdują zastosowanie w wielu dziedzinach nauki i techniki, np. w przemyśle farmaceutycznym. Dane uzyskane w wyniku takich pomiarów zawierają informację odnośnie rodzaju i stężenia badanej substancji, jednakże są one często kłopotliwe w bezpośredniej interpretacji. Z tego powodu, istnieje konieczność wykorzystania odpowiednich metod matematycznych, które umożliwiają uzyskanie bezpośredniej i precyzyjnej...
-
Modelowanie matematyczne systemów fizjologicznych i farmakokinetycznych dla wspomagania diagnostyki terapii
PublicationKsiążka jest poświęcona matematycznemu modelowaniu systemów biomedycznych, ze szczególnym uwzględnieniem systemów fizjologicznych i farmakokinetycznych. W tym obszarze bardzo przydatne są metody modelowania kompartmentowego, wykorzystujące opis systemu w kategoriach zmiennych stanu. W tych kategoriach sformułowana jest także teoria filtracji stochastycznej Kalmana. Filtracja stochastyczna stosowana jest do usuwania zakłóceń z sygnału...
-
Novel method of lung area extraction in chest perfusion computed tomography
PublicationChest perfusion computed tomography (pCT) is a useful technique in the medical diagnosis of how organs function. Perfusion CT scans are used to calculate perfusion parameters. In the case of automated methods of lung perfusion parameters calculation, the prior extraction of the lung area is desired to avoid unnecessary calculation in an area outside the lung cross-section and to avoid wasting time on processing signals of no diagnostic...
-
Nowa metoda kalibracji woltamperometrii stałoprądowej
PublicationW artykule omówiono no wą metodę kalibracji elektrod woltamperometrycznych opierającą się na wykorzystaniu wyłącznie jednego roztworu wzorcowego. Przedstawiono podstawy teoretyczne zaproponowanej metody oraz wyniki jej weryfikacji laboratoryjnej. Weryfikacja ta potwierdziła możliwość zastosowania zaproponowanej metody do kalibracji elektrod woltamperometrycznych w zakresie stężeń znacznie mniejszych od stężenia jonów depolaryzatora...
-
Obrazowanie termiczne w podczerwieni w diagnostyce medycznej – stan i perspektywy
PublicationOmówiono stan i perspektywy rozwoju techniki obrazowania termicznego w podczerwieni w diagnostyce medycznej. Jest to dziedzina szybko rozwijająca się, o sporych możliwościach aplikacyjnych ze względu na unikalne cechy łączące możliwości obrazowania zarówno procesów fizjologicznych, funkcjonalnych, jak i badań o charakterze strukturalnym. W szczególności omówiono postępy w rozwoju Aktywnej Termografii Dynamicznej. Przedstawiono...
-
Optimal configuration of an electrode array for measuring ventricles' contraction
PublicationAn influence of an electrode-array configuration on an impedance signal composition for a fixed spatial distribution of its sources is examined in the paper. The Finite Element Method and Geselowitz relationship were used for examining three different electrode-arrays. A sensitivity approach was used to evaluate each configuration assuming that localization of the signal source is known. A conductivity change, thus the source of...
-
OPTIMIZATION OF NASICON PREPARATION METHOD
PublicationNasicon is a solid conductor which has an ability to conduct Na+ ions and it is used in solid gas sensors. In this article a method of Nasicon preparation appropriate for gas sensing application by solgel technique is presented. Influence of the fabrication process parameters on properties of obtained samples was determined. Results of X-Ray diffraction, density, porosity, conductivity, and activation energies measurement are presented.
-
PROJEKT I IMPLEMENTACJA WIELOKANAŁOWEGO DETEKTORA BEZDECHU SENNEGO
PublicationDiagnostyka obturacyjnego bezdechu senne-go opiera się na szczegółowym wywiadzie medycznym i badaniu polisomnograficznym. Jest ono drogie i mało kom-fortowe dla pacjenta. Opisywane urządzenie pozwala na przeniesienie procesu diagnostycznego ze specjalistycznych klinik do domu pacjenta. Całonocna rejestracja szeregu biosygnałów pozwoli na automatyczną detekcję obturacyj-nego bezdechu sennego
-
PROJEKTOWANIE GRAFICZNEGO INTERFEJSU UŻYTKOWNIKA DLA OSÓB STARSZYCH
Publication: W artykule opisano zagadnienia dotyczące tworzenia optymalnego interfejsu użytkownika przeznaczonego dla osób starszych i przewlekle chorych.
-
Przydatność badania spirometrycznego w diagnostyce mikroangiopatii płucnej
PublicationMikroangiopatia płucna jest słabo poznanym upośledzeniem funkcji układu oddechowego w wyniku długotrwałej cukrzycy. Do chwili obecnej nie opracowano prostej i skutecznej metody wykrywania mikroangiopatii płucnej. Celem tej publikacji jest przedstawienie przeprowadzonych badań nad praktycznym wykorzystaniem wyników badania spirometrycznego w diagnostyce mikroangiopatii płucnej. Badanie spirometryczne jest tanie i powszechnie stosowane...
-
Quantitative Active Dynamic Thermal IR-Imaging and Thermal Tomography in Medical Diagnostic
PublicationPrinciples of Active dynamic thermal (ADT) IR-imaging and Thermal Tomography are described in details. Basic medical applications of this new modality are also discussed.
-
RARE-EARTH ELEMENTS DOPING OF BARIUM CERATE AND ZIRCONATE SOLID SOLUTION
PublicationThe properties of doped barium cerate barium zirconate solid solution are presented in presented work. It was found that doping of solid solution of barium cerate and zirconate by rare-earth elements have an influence on microstructure and electrical properties of the samples.
-
Real-time working gas recognition system based on the array of semiconductor gas sensors and portable computer Raspberry PI
PublicationThe gas-analyzing systems based on the array of partially selective gas sensors and pattern-recognition techniques are potentially fast and low-cost alternative for other devices, like gas analysers. They give the possibility of recognition the type and the concentration of measured volatile compounds in their working environment. In this work we present the implementation of gas recognition system, in which the signals from an...
-
Reflektancyjny pulsoksymetr mocowany na klatce piersiowej
PublicationPulsoksymetria to nieinwazyjna i nowoczesna metoda badania wysycenia krwi tlenem oraz pulsu. Istnieją dwie metody pomiaru: transmisyjna i reflektacyjna, różniące się wzajemnym położeniem źródła światła i fotodetektora. Niniejszy artykuł przedstawia pierwszą fazę projektu reflektancyjnego pulsoksymetru mocowanego na klatce piersiowej.
-
System inteligentnego budynku w oparciu o sieci bezprzewodowe
PublicationW artykule przedstawiono prototypowy system automatyki inteligentnego budynku wykorzystujący protokół ZigBee. W ramach pracy przedstawiono ogólne rozważania konstrukcji elementów aktywnych sieci. Przedstawiono też oryginalne opracowania węzłów sieci stanowiących rozszerzenie idei intelignetnego budynku o urządzenia pomocne w diagnostyce medycznej. Przeanalizowano problem i zaproponowano koncepcję poprawy bezpieczeństwa danych transmitowanych...
-
Śledzenie wzroku w środowisku wielo-ekranowym
PublicationW tym artykule przedstawiona jest zasada działania interfejsu pozwalającego na śledzenie wzroku w środowisku wieloekranowym. Opisane zostały wyniki jakie możn uzyskać stosując algorytm detekcji ekranów korzystając z markerów identyfikacyjnych oraz algorytmu detekcji ekranów z chmury punktów. Użyty algorytm zaostał przetestowany na wirtualnej reprezentacji potencjalnych modułów środowiska wieloekranowego. Wyniki zostały przedstawione...
-
Taguchi sensors under temperature modulation
PublicationSemiconductor gas sensors are widely used in gas- analyzing applications for various gas species determination due to their low cost and possibility to detect number of different gases. However, one of the main problems with such sensors is their lack of selectivity. To overcome this issue different ap- proaches can be used. One of them is the operation with sensor temperature modulation combined with dedicated data process- ing...
-
The Role of Thermal Monitoring in Cardiosurgery Interventions
PublicationThe results of a research project devoted to the analysis of the value of IR-thermal imaging in monitoring the quality of cardiosurgery interventions are presented. The role of the ADT is underlined.
-
Thermal ablation modeling via bioheat equation
PublicationWe consider Pennes’ bioheat equation and discuss an implicit numerical scheme which has better stability properties than other approaches. Our discussion concerns Carthesian geometry problems, however it carries over to spherical geometry models and more complicated shapes.
-
TOXIC GASES IDENTIFICATION USING SINGLE ELECTROCATALYTIC SENSOR RESPONSES AND ARTIFICIAL NEURAL NETWORK
PublicationThe need for precise detection of toxic gases drives development of new gas sensors structures and methods of processing the output signals from the sensors. In literature, artificial neural networks are considered as one of the most effective tool for the analysis of gas sensors or sensors arrays responses. In this paper a method of toxic gas components identification using a electrocatalytic gas sensor as a detector and an artificial...
-
VOLTAMMETRIC DETERMINATION OF DEOXYRIBONUCLEIC ACID PRESENCE ON A CARBON ELECTRODE
PublicationThis paper presents a voltammetry as a useful method to analyse DNA from different species. This electrochemical method is well know and used in different analyses. The influence of an area of working electrode and the capacity component, is shown at equals and the measurement. In voltammetry DNA measurement the capacity component is very important and must be taken into consideration. All mathematical analyses were verify at laboratory.
-
Wpływ konfiguracji elektrod pomiarowych oraz parametrów pomiaru na EDR
PublicationW pracy przebadano wplyw wybranych konfiguracji elektrod na jakość uzyskiwanego sygnału EDR. Analizie poddane zostały również częstotliwość próbkowania sygnału EKG i rozdzielczość przetwornika AC/DC. Optymalną konfiguracją elektrod jest odprowadzenie kończynowe pierwsze. Minimalne parametry układu pomiarowego do uzyskania wysokiej jakości sygnału EDR, to częstotliwość probkowania 2,5kHz oraz 14-bitowy przetwornik AC-DC.
-
Wpływ metodyki obliczania mózgowej objętości krwi na wiarygodność diagnozy udaru niedokrwiennego w badaniach DSC-MRI
PublicationNiedokrwienny udar mózgu jest jednym z najczęściej spotykanych oraz najlepiej udokumentowanych incydentów mózgowo-naczyniowych (Dani et al., Ann Neurol 2011, 70(3), 384-401), a obrazowanie mózgu metodą DSC-MRI (ang. Dynamic Susceptibility Contrast - Magnetic Resonance Imaging) wskazuje się jako umożliwiające m.in. diagnozę niedokrwionej tkanki, prognozę jej dalszych losów, oraz rozróżnienie niedokrwienia odwracalnego od nieodwracalnego...
-
WYKORZYSTANIE SPEKTROSKOPII IMPEDANCYJNEJ DO BADANIA ZANIECZYSZCZENIA GLEB METALAMI CIĘŻKIMI
PublicationJednym z największym problemów obecnych czasów jest zanieczyszczenie środowiska metalami ciężkimi. Z przeprowadzonego studium literaturowego wynika, że w celu określenia stopnia zanieczyszczenia gleb metalami ciężkimi można zastosować metody elektrochemiczne, w tym spektroskopię impedancyjną. Przy czym, w celu zapewnienia odpowiedniej dokładności wykonywanych oznaczeń, należy zmodyfikować procedurę pomiarową oraz opracować odpowiednią...
-
WYKORZYSTANIE SZTUCZNYCH SIECI NEURONOWYCH DO ANALIZY ODPOWIEDZI MATRYC CZUJNIKÓW GAZU
PublicationW pracy zaprezentowano efekt wykorzystania sztucznych sieci neuronowych w procesie analizy odpowiedzi matryc czujników gazu. Przedstawione zostały podstawy teoretyczne sieci neuronowej jednokierunkowej oraz dwóch algorytmów uczenia tej sieci, następnie została ona wykorzystana do klasyfikacji substancji lotnych na podstawie pomiarów matrycy sześciu rezystancyjnych półprzewodnikowych czujników gazu. Przy użyciu środowiska obliczeniowego...
-
Wykorzystanie termografii dynamicznej w ocenie ukrwienia płatów złożonych w zabiegach rekonstrukcyjnych piersi
PublicationJedną z najczęściej wykorzystywanych technik operacyjnych w chirurgii rekonstrukcyjnej piersi tkankami wła- snymi są zabiegi przy użyciu płata skórno-mięśniowego typu TRAM. Są one obarczone ryzykiem niedokrwiennym. Dlatego dokładne określenie ukrwienia płata jest niezbędne do osiągnięcia zamierzonego efektu operacji. Spośród licznych metod uzupełniających kliniczną ocenę ukrwienia płatów, wybrano termografię dynamiczną (TD) ze...
-
YSZ Thin film deposited on porous substrate by spray pyrolysis
PublicationIn this work the results of deposition of YSZ layer on a porous substrate using an ultrasonic Spray Pyrolysis are presented.
Year 2012
-
A Special Issue on Ubiquitous Computing in Healthcare
PublicationPrzetwarzanie bez granic w opiece zdrowotnej jest szczególnie istotne w konteście starzejącego się społeczeństwa. W pracy przedstawiono omówienie roli przetwarzania bez granic oraz opisano powiązane dziedziny tematyczne i prezentowane w numerze specjalnym zagadnienia.
-
Adjusted subpixel method enables optimisation of bronchial measurements in high-resolution CT
PublicationArtykuł przedstawia metodę korekcji pomiaru rozmiaru oskrzeli w techice HRCT. W celu walidacji metody zastosowano fantom. W efekcie opracowano metodę nieliniowej predykcji rzeczywistych rozmiarów ścianek małych oskrzeli w obrazach HRCT.
-
Application of adjusted subpixel method (ASM) in HRCT measurements of the bronchi in bronchial asthma patients and healthy individuals
PublicationBackground: Recently, we described a model system which included corrections of high-resolution computedtomography (HRCT) bronchial measurements based on the adjusted subpixel method (ASM).Objective: To verify the clinical application of ASM by comparing bronchial measurements obtained bymeans of the traditional eye-driven method, subpixel method alone and ASM in a group comprised ofbronchial asthma patients and healthy individuals.Methods:...
-
Aproksymacja zmian stężenia znacznika w badaniach pCT płuc
PublicationW artykule zaproponowano nową metodę aproksymacji zmian stężenia znacznika w badaniach pCT płuc. Zmiany stężenia znacznika są skanowane z częstotliwością kilkakrotnie większą niż częstotliwość oddechu. Metoda opiera się na spostrzeżeniu, że częstotliwość występowania pików na krzywych zmian stężenia znacznika jest równa częstotliwości oddechu badanego. Zaprezentowano przykładowe dopasowanie funkcji regresji w postaci krzywej Gaussa...
-
Assessment of cardiovascular risk in assisted living
PublicationWady i choroby układu krążenia są jedną z podstawowych przyczyn problemów zdrowotnych oraz przyczyn śmierci. Wczesne ich wykrycie jest szczególnie cenne jako, że może zapobiec przez poważnymi incydentami (np. zawał, udar, itp.). W artykule przedstawiono nasobny system pomiarowy integrujący wiele pomiarów przydatnych do oceny problemów kardiologicznych.Disorders of the heart and blood vessels are the leading cause of health problems...
-
Badanie przewodnictwa jonowego materiału katodowego do ogniw SOFC na bazie La1-xSrxMnO3-δ
PublicationMieszane przewodniki jonowo-elektronowe na bazie domieszkowanego manganianu lantanu znajdują powszechne zastosowanie m.in. jako elektrody w ogniwach paliwowych, czujnikach gazów lub jako warystory. Jednak wciąż niepoznane do końca mechanizmy występowania zjawiska mieszanego przewodnictwa sprawiają, że prace nad tymi materiałami wciąż trwają. Określenie składowej jonowej tego typu materiałów perowskitowych wymaga zastosowania...
-
Badanie właściwości czujnika elektrokatalitycznego na bazie tytanianu litowo-lantanowego
PublicationW pracy przedstawiono wyniki badań wpływu stężenie ditlenku azotu na kształt charakterystyk prądowo-napięciowych (I-V) nowego czujnika elektrokatalitycznego na bazie elektrolitu stałego z mobilnymi jonami litu LiLaTiO3. Czujnik ten został wykonany w technologii ceramicznej w formie pastylki z porowatymi elektrodami złotymi naniesionymi po obu jej stronach. Wykonano pomiary odpowiedzi czujnika w temperaturach 175ºC i 300ºC. Stężenie...
-
Chemiresistive gas sensors based on carbon nanotubes - fabrication and application
PublicationOpisano przygotowanie i możliwości zastosowania chemirezystancyjnych czujników gazów wykonanych z nanorurek węglowych.
-
Chemiresistive gas sensors based on carbon nanotubes - fabrication and application
PublicationMany types of sensors have been invented to identify and quantify chemical contamination in the gas phase. Sensors based on carbon nanotubes are particularly attractive because of their wide range of applicaions and potential use in electronic nose that can be controlled using algorithms of Artificial Intelligence. Sensor functions, fabrication and selected applications are reviewed and discussed with focus on chemiresistors. Drawbacks...
-
Conducting Polymer Microelectrodes Anchored to Hydrogel Films
PublicationArtykuł prezentuje wytwarzanie organicznych hydrożeli z mikroelektrodami poli(3,4-ethylenedioxythiophene, PEDOT), które wykazują obniżoną rezystywność 100 Ω/□. Proces przygotowania rozpoczyna się elektroosadzania przewodzącego PEDOT (ok. 20 S/cm) na mikroelektrodach Pt. Elektrolityczne wiąże się film PEDOT z hydrożelem. Tak wytworzona struktura jest odrywana elektrycznie pd podłoża.
-
Data analysis of FTIR spectra for study of outlet gases of Solid Oxide Fuel Cells fuelled by biogas
PublicationW pracy przedstawiono system umożliwiający połączenie spektroskopii FTIR z specjalnie zaprojektowanym oprogramowaniem w celu uzyskania informacji o stężeniach gazów wylotowych z ogniw paliwowych SOFC. Przebadane zostały główne produkty reformingu biogazu: tlenek węgla, dwutlenek węgla, metan oraz wodór. Opisane oprogramowanie umożliwia w prosty i szybki sposób uzyskanie informacji o gazach wylotowych ogniwa paliwowego.
-
DETEKTOR BEZDECHU SENNEGO DO UŻYTKU DOMOWEGO
PublicationDiagnostyka obturacyjnego bezdechu sennego zazwyczaj polega na analizie całonocnego badania polisomnograficznego, które wymaga niestety całonocnego pobytu w specjalistycznej klinice i jest mało komfortowe dla pacjenta. Urządzenie opisane w niniejszym dokumencie umoŜliwia całonocną rejestrację trzech kanałów czynności elektrycznej serca (EKG), funkcji oddechu, sygnału z akcelerometru oraz odgłosów chrapania. Pomiar moŜe odbywać...
-
Donor-substituted SrTi1+xO3−δ anodes for SOFC
PublicationNonstoichiometric Nb-substituted SrTiO3 compounds were investigated in order to discuss the influence of nonstoichiometry at the sample properties in the light of recent results reported in the literature. Structural and electrical properties of samples were characterized. Investigated compounds were also applied as anodes for Solid Oxide Fuel Cells and their reactivity with YSZ electrolyte was examined. The defect chemistry explaining...
-
Donor-substituted SrTi1+xO3−δ anodes for SOFC
PublicationPrzebadano wpływ niestechiometrii na właściwości tytanianu strontu domieszkowanego niobem. Zaproponowano chemię defektów dla tego typu związków.
-
Effective dielectric constant of two phase dielectric systems
PublicationW tym artykule model brick-layer ścianie został rozszerzony na dwufazowe systemy perkolacyjne. Porównano wyniki obliczeń z danymi eksperymentalnymi. Stałe dielektryczne obu faz oraz próg perkolacji pozwala na wyznaczenie efektywnej stałej dielektrycznej systemu dwufazowego.
-
Effective dielectric constant of two phase systems: Application to mixed conducting systems
PublicationW pracy przedstawiono wyniki badań spektroskopii impedancyjnej systemów dwufazowych oraz ich porównanie z wynikami oczekiwanymi przez różne modele.
-
Electrocatalytic sensor based on Nasicon with auxiliary layer = Czujnik elektrokataliczny na bazie Nasiconu z warstwą dodatkową
PublicationW pracy zostały przedstawione wyniki pomiarów czujnika na bazie Nasiconu pracującego w trybie elektrokatalitycznym. Czujniki takie pobudzane są zmieniającym się napięciem przy jednoczesnym pomiarze odpowiedzi prądowej. Przygotowano czujniki ceramiczne o dwóch różnych typów. Pierwszy z nich to czujnik posiadający dwie identyczne elektrody złote, pomiędzy którymi znajduje się elektrolit stały. Drugi czujnik posiada złote elektrody...
-
Evaluation of porous ferritic Fe22Cr stainless steel for solid oxide fuel cells at high temperature
PublicationW pracy przedstawiono wyniki badań korozji stali Fe22Cr w wysokich temperaturach.