dr hab. inż. Rafał Andrzejczyk
Zatrudnienie
- Profesor uczelni w Instytut Energii
Publikacje
Filtry
wszystkich: 111
Katalog Publikacji
Rok 2024
-
A New Approach of Solidification Analysis in Modular Latent Thermal Energy Storage Unit Based on Image Processing
PublikacjaThe solidification process of RT18HC in a cylindrical shell and tube storage unit has been studied using a new methodology based on image processing. The main idea of the algorithm is to label the region of solidification and use statistical functions to calculate the dimensions of the solidification front over time. Said analysis includes two methods. The first method is to measure the solid fraction changes during solidification....
Rok 2023
-
The In-House Method of Manufacturing a Low-Cost Heat Pipe with Specified Thermophysical Properties and Geometry
PublikacjaVarious types of heat pipes are available to purchase off the shelf, from various manufacturers, but most of them have strictly defined geometry and technical parameters. However, when there is a need to use a heat pipe (HP) with an unusual size and shape or working conditions other than the standard ones, it becomes very costly to order them from manufacturers, especially in small quantities, and only a few producers are willing...
-
Study on effective front region thickness of PCM in thermal energy storage using a novel semi-theoretical model
PublikacjaThermal energy storage in mobile applications, particularly battery of electric vehicles, is currently gaining a lot of importance. In this paper, a semi-theoretical time-dependent mathematical model of the phase change in a double shell thermal energy storage module has been developed where the inner tube is a heat exchange surface. An effective front region thickness for the melting and solidification process has been studied....
-
Recent advances of selected passive heat transfer intensification methods for phase change material-based latent heat energy storage units: A review
PublikacjaThe following article overviews recent studies regarding heat transfer enhancement methods, explicitly focusing on fins and coils utilization, in phase change material-based latent heat thermal energy storage systems. It discusses the influence of various geometrical and material parameters on the melting and solidification processes, as well as the orientation of the heat transfer surface within the storage tank. Additionally,...
-
Heat transfer enhancement of modular thermal energy storage unit for reversible heat pump cooperation
PublikacjaThe following article presents experimental comparison research on a hexagonal shelland-tube latent thermal energy storage (TES). Such shape of a shell was deliberately chosen instead of a cylindrical one due to its high modularity and with intent for future applications in automobiles (EV and PHEV) air conditioning systems (HVAC). Two geometries of helical coils, acting as tubes, were studied in this article. One was a simple...
-
Experimental and numerical investigation on shell and coil storage unit with biodegradable PCM for modular thermal battery applications
PublikacjaThermal energy storage (TES) in automotive applications is currently growing in importance. TES can visibly reduce primary energy consumptions, decrease CO2 emission, and improve thermal comfort in electric as well as hybrid vehicles. However, to meet the new ambitious target (15% reduction of CO2 emissions in the new cars until 2025) it is required to use plug-in electric vehicles. For this reason, this paper focuses on the optimization...
-
A review of phase change materials and heat enhancement methodologies
PublikacjaPhase change materials (PCMs) are an efficient alternative to store and release heat at a specific range of temperature. Here PCMs and heat enhancement methodologies for PCM storage are reviewed. A short overview of PCMs and their applications is presented in addition to the progress during the last 10 years. Heat enhancement techniques, that is, extended surfaces, multiple and composite PCMs, and encapsulation techniques, are...
Rok 2021
-
Experimental and theoretical study of a vertical tube in shell storage unit with biodegradable PCM for low temperature thermal energy storage applications
PublikacjaThis article presents the experimental investigations of the coconut oil-based TES module for HVAC applications in the ambient and-sub ambient temperature range. To properly study this problem modular experimental module and test loop were developed. Special attention has been paid to study the physical mechanism of the melting/solidification process for natural substance (coconut oil) which has perspectives to be used in thermal...
-
Experimental and Computational Fluid Dynamics Studies on Straight and U-Bend Double Tube Heat Exchangers with Active and Passive Enhancement Methods
PublikacjaIn this work, the authors wanted to demonstrate the possibility to increase the heat transfer efficiency by using simple wire coil inserts to create turbulent flow in the boundary layer as well as air blowing into the annulus of the pipe. Experimental investigations were carried out for four heat exchanger constructions, i.e., plain double tube, turbulized double tube, plain U-bend double tube, U-tube with turbulator, plain double...
Rok 2020
-
Experimental Investigations on the Influence of Coil Arrangement on Melting/Solidification Processes
PublikacjaThe latent heat thermal energy storage units are very popular because of their high energy density and almost close to constant temperature during the charging/discharging. In the present study has been proposed new shell-and-coil geometry with a shifted coil position to enhance the performance of phase change thermal magazine. The experimental investigations have been performed both for the melting and solidification process of...
Rok 2019
-
Thermal and economic investigation of straight and U-bend double tube heat exchanger with coiled wire turbulator
PublikacjaExperimental research has been carried out for four individual heat exchanger constructions, i.e., plain double tube, turbulized double tube, plain U-bend and U-bend with turbulator. Tests were made for the water-water system. The study covered a wide measuring range, i.e., Re = 800–9000 – on the shell side, for a constant cold water temperature of 9 ◦C and hot water of 50 ◦C. The heat exchangers were made from copper tubes with...
-
The impact of environmentally friendly refrigerants on heat pump efficiency
PublikacjaThis paper discusses the issue of heat pump simulation. Lower operating costs can be achieved through good equipment design and appropriate operation. Detailed technical and economic analysis inform the selection of system components with the highest possible efficiency and lower energy demand. The use of systems based on environmentally friendly refrigerants can deliver long product life, which is associated with a shorter payback...
-
Heat transfer and pressure drop characteristics of the silicone-based plate heat exchanger
PublikacjaThe paper presents an experimental investigation of a silicone based heat exchanger, with passive heat transfer intensification by means of surface enhancement. The main objective of this paper was to experimentally investigate the performance of a heat exchanger module with the enhanced surface. Heat transfer in the test section has been examined and described with precise measurements of thermal and flow conditions. Reported...
-
Experimental study on single phase operation of microjet augmented heat exchanger with enhanced heat transfer surface
PublikacjaThe article presents experimental investigations on a prototype heat exchanger. Presented research is focused on combined active and passive enhancement techniques of surface modification and microjet impingement. The results were compared to reference plate heat exchanger without microjet impingement. The Wilson plot method was applied to determine the heat transfer coefficients in the single phase operation. The heat exchanger...
-
Experimental investigation of heat transfer enhancement in straight and U-bend double-pipe heat exchanger with wire insert
PublikacjaIn this paper, the possibility of heat transfer enhancement in the U-bend exchanger was presented. Experimental research has been carried out for four individual heat exchanger constructions i.e. plain tube in tube, turbulized tube in tube, plain U-bend and U-bend with turbulator. Also, heat transfer experiments for various boundary conditions were performed to obtain reference values. In case of U-bend exchanger with and without...
Rok 2018
-
Wykorzystanie magazynu chłodu w kompaktowej komorze przechowalniczej
PublikacjaNiniejszy artykuł został poświęcony możliwości wykorzystania pasywnych systemów chłodzenia w mobilnych komorach przechowalniczych. Dokonano przeglądu rozwiązań dostępnych na rynku komór termicznych wraz z wykorzystywanymi w nich technologiami chłodzenia. Przeprowadzono analizę możliwych do zastosowania nośników chłodu w systemach pasywnego chłodzenia. Wykazano, iż oprócz popularnych na rynku materiałów zmiennofazowych (PCM – ang....
-
Response to the queries raised by Dr M.M. Awad in a letter to editor comments on “Pressure drop of HFE7000 and HFE7100 during flow condensation in minichannels”
Publikacja.
-
Experimental validation of pressure drop models during flow boiling of R134a – effect of flow acceleration and entrainment
PublikacjaA crucial step to assure proficient work of power and process apparatus is their proper design. A wide array of those devices operates within boiling or condensation of the working fluid to benefit from high heat transfer rates. Two-phase flows are associated with high heat transfer coefficients because of the latent heat of evaporation and high turbulence level between the liquid and the solid surface. Predicting heat transfer...
-
Experimental Investigations On The Momentum Pressure Drop During Flow Boiling Of R134a
PublikacjaThe article presents experimental investigations of the pressure drop during twophase flow. Experiments were performed for both adiabatic and heated flow of R134a. Obtained flow patterns were compared with the literature. Obtained data is used to validate momentum pressure drop predictions, a set of graphs showing comparisons, for a representative set of experimental conditions, of the two-phase frictional pressure gradients for...
-
Experimental investigations on heat transfer enhancement in shell coil heat exchanger with VARIABLE Baffles GEOMETRY
PublikacjaThe paper presents the possibility of using passive intensification of heat transfer in the form of baffles to increase the energy efficiency of the shell and coil heat exchanger. The experiment was carried out by using a modular coil heat exchanger in the form of an electric heater. Water was used as a working fluid with constant thermal-flow parameters at the inlet of the module. It should be noted that experiments were made...
-
Experimental investigation on straight and u-bend double tube heat exchanger with active and passive enhancement methods
PublikacjaAuthors in this work want to demonstrate the possibility to increase the heat transfer efficiency by using simple wire coil inserts to create turbulent flow in the boundary layer as well as air blowing into the annulus of the pipe. In the study, Wilson plot approach was applied in order to estimate heat transfer coefficients for all heat exchanger (HX) configurations. The study focuses on experimental values of heat transfer coefficient...
-
Experimental Investigation of the Thermal Performance of a Wickless Heat Pipe Operating with Different Fluids: Water, Ethanol, and SES36. Analysis of Influences of Instability Processes at Working Operation Parameters
PublikacjaIn this study, the influences of different parameters on performance of a wickless heat pipe have been presented. Experiments have been carried out for an input power range from 50 W to 300 W, constant cooling water mass flow rate of 0.01 kg/s, and constant temperature at the inlet to condenser of 10 C. Three working fluids have been tested: water, ethanol, and SES36 (1,1,1,3,3-Pentafluorobutane) with different filling ratios (0.32,...
-
Experimental and comparative study on the two-phase pressure drop of air-water mixture in U-bend and straight pipe annuli
PublikacjaIn this paper, the experimental and theoretical analysis of pressure drop in singlephase and two phase-flow were presented for straight and U-bend smooth tube annulus and tube annulus with wire coil insert. Experiments for various boundary conditions were performed. In case of U-tube and straight tube with and without turbulator, tests were made for the water-water and air-water systems. The study covered a wide measuring range,...
-
An experimental investigation on the effect of new continuous core-baffle geometry on the mixed convection heat transfer in shell and coil heat exchanger
PublikacjaIn the article, the authors presented the influence of continuous core-baffle geometry at mixed convection heat transfer in shell and coil heat exchanger. Experiments were carried out for a large power range, i.e. from 100W to 1200W and mass flow rates ranging from 0.01 kg/s to 0.025 kg/s. During the experiments, the mass flow rate of cooling water, the temperature of water at the inlet and outlet as well as the wall temperature...
Rok 2017
-
Tradycyjna lodownia – ekoenergetyczny magazyn żywności
PublikacjaW artykule omówiono konstrukcję oraz zasadę działania naturalnych przechowalni żywności, tzw. lodowni. Przedstawiono kilka przykładów takich konstrukcji wraz z opisem ich budowy. Na przykładzie jednego rozwiązania szczegółowo opisano zasadę działania procesów zachodzących wewnątrz przechowalni. Podkreślono neutralność tego typu budowli wobec środowiska. Przedstawiono zalety i wady analizowanego rozwiązania na tle sprężarkowych...
-
Thermodynamic and geometrical characteristics of mixed convection heat transfer in the shell and coil tube heat exchanger with baffles
PublikacjaThe article presents passive heat transfer enhancement method in the form of baffles to increase the energy efficiency of the shell coil heat exchanger. Conducted literature review shows that, despite numer- ous studies, there is little work on the intensification of heat transfer at the shell side. Most of the work focuses on the impact of geometrical parameters of the coil itself. This article successfully proves that it is possible...
-
The performance of H2O, R134a, SES36, ethanol, and HFE7100 two-phase closed thermosyphons for varying operating parameters and geometry
PublikacjaIn this study, the influences of different parameters at performance two-phase closed thermosiphon (TPCT) was presented. It has been confirmed that the working fluid, as well as operating parameters and fill ratio, are very important factors in the performance of TPCT. The article shows characteristics of gravitational tube geometr ies, as well as the technical characteristic of the most important system components, i.e., the evaporator/condenser....
-
Sposoby zagospodarowania ciepła odpadowego z silników napędowych jednostek pływających Cześć 1. Wykorzystanie ciepła do napędu urządzeń chłodniczych
PublikacjaEnergia chemiczna paliwa jest w wielu przypadkach zaledwie w połowie wykorzystana jako energia napędowa silnika. Pozostała część jako ciepło odpadowe przekazywana jest do otoczenia. Dzięki odpowiednim układom przetwarzania ciepło ze spalin można wykorzystać do wytwarzania chłodu lub jako ciepło użytkowe, w systemach HVAC (ang. heating, ventilation, air conditioning – ogrzewanie, wentylacja, klimatyzacja). Tym samym koszty pracy...
-
Sposoby zagospodarowania ciepła odpadowego z silników jednostek pływających Cześć 2. Wykorzystanie ciepła do ogrzewania
PublikacjaW pierwszej części artykułu (COW 2/2017) omówiono możliwości wykorzystania nieużytkowej energii chemicznej paliwa do chłodzenia jednostek pływających. W drugiej części autorzy opisali systemy pozwalające wykorzystać tę energię do ogrzewania. Oprócz opisania budowy układów pozwalających na wykorzystanie ciepła odpadowego do ogrzewania, porównano je pod względem wydajności. Podjęto także próbę wskazania rozwiązania o najwyższej efektywności...
-
Projekt wężownicowego wymiennika ciepła
PublikacjaPrzedmiotem niniejszego artykułu jest zaprezentowanie konstrukcji wężownicowego wymiennika ciepła powstałej w ramach pracy inżynierskiej w Katedrze Energetyki i Aparatury Przemysłowej. Podstawowym założeniem pracy było zoptymalizowanie aparatu cieplnego w taki sposób, aby możliwe było jak najefektywniejsze przekazywanie ciepła do przepływającego płynu. Oparto się tu przede wszystkim na rozważaniach dotyczących wpływu modyfikacji...
-
Moduł eksperymentalny do badania wężownicowych wymienników ciepła
PublikacjaArtykuł dotyczy badań eksperymentalnych modułu do badania wężownicowych wymienników ciepła. Opracowanie zawiera przykłady zastosowania wymienników z wężownicami, opis stanowiska oraz wstępne badania.
-
Metody intensyfikacji wymiany ciepła w kompaktowym wymienniku ciepła typu rura w rurze
PublikacjaAparaty cieplne typu rura w rurze ze względu na prostotę swojej geometrii oraz łatwo powtarzalny proces produkcji nadal są jednymi z czołowych rozwiązań wykorzystywanych w wielu przemysłowych aplikacjach . Wykorzystuje się je od systemów chłodniczych i klimatyzacyjnych po instalacje cieplne czy nawet układy spotykane na stacjach kosmicznych lub statkach powietrznych. W zależności od systemu technicznego pierwszoplanowa rolę przy...
-
Metody intensyfikacji wymiany ciepła "po stronie płaszcza" w kompaktowym wężownicowym wymienniku ciepła
PublikacjaZe względu na rosnącą populację i zwiększające się zanieczyszczenie środowiska naturalnego coraz aktualniejsza staje się tematyka wysokosprawnych wymienników ciepła . Elementy te mają duże znaczenie dla systemów energetycznych, instalacji chłodniczych i wentylacyjnych oraz inżynierii spożywczej i chemicznej . Jedną z częściej spotykanych konstrukcji jest wężownicowy aparat cieplny . Ten typ aparatu cieplnego został opracowany w...
-
Kurs na energię
PublikacjaJednym z nadrzędnych celów, jakie stawia przed sobą Unia Europejska, jest realizacja tzw. polityki zrównoważonego rozwoju. Ma ona polegać na implikacji sprzyjających warunków dla powstania konkurencyjnej gospodarki niskoemisyjnej.
-
Investigations on mixture preparation for two phase adiabatic pressure drop of R134a flowing in 5 mm diameter channel
PublikacjaThe article presents detailed two-phase adiabatic pressure drops data for refrigerant R134a. Study cases have been set for a mass flux varying from 200 to 400 kg/m2 s, at the saturation temperature of 19.4 ◦C. Obtained experimental data was compared with the available correlations from the literature for the frictional pressure drop during adiabatic flow. Influence of mixture preparation on pressure drop was investigated, for...
-
INTENSYFIKACJA WYMIANY CIEPŁA W WYMIENNIKU WĘŻOWNICOWYM Z WYKORZYSTANIEM PRZEGRÓD O RÓŻNEJ GEOMETRII
PublikacjaW pracy zaprezentowano możliwości wykorzystania pasywnej intensyfikacji wymiany ciepła w postaci przegród dla podniesienia efektywności energetycznej wymiennika wężownicowego. Badania zostały przeprowadzone z wykorzystaniem modułowego wymiennika z wężownicą w postaci grzałki elektrycznej. Medium odbierającym ciepło była woda o stałych parametrach cieplnoprzepływowych na wlocie do modułu. Pomiary przeprowadzono dla szerokiego zakresu...
-
Experimental investigations on adiabatic frictional pressure drops of R134a during flow in 5mm diameter channel
PublikacjaThe article presents detailed two-phase adiabatic pressure drops data for refrigerant R134a at a saturation pressure of 5.5 bar corresponding to the saturation temperature of 19.4 °C. Study cases have been set for a mass flux varying from 100 to 500 kg/m2 s. The frictional pressure drop was characterized for the refrigerant R134a, for vapor qualities ranging from 0 to 1. Long-time thermal stability of test facility allowed to gather...
-
Detailed experimental investigations on frictional pressure drop of R134a during flow boiling in 5 mm diameter channel: The influence of acceleration pressure drop component =Études expérimentales détaillées sur la chute de pression frictionnelle du R134a lors de l'ébullition en écoulement dans un canal de 5 mm de diamètre : influence de la composante d'accélération de la chute de pression
PublikacjaThis article presents detailed two-phase diabatic pressure drop data for refrigerant R134a at a saturation pressure of 5.5 bar corresponding to the saturation temperature of 19.4 °C. Study cases have been set for a mass flux varying from 100 to 500 kg m−2 s−1. The obtained data are used as a validation of the void fraction literature models, a set of graphs shows comparisons, for a representative set of experimental conditions,...
-
CHARAKTERYSTYKA WYMIANY CIEPŁA I OPORÓW PRZEPŁYWU OMYWANIA MIKROSTRUGAMI ROZWINIĘTEJ POWIERZCHNI
PublikacjaW artykule przedstawiono eksperymentalne badania kompaktowego wymiennika ciepła z intensyfikacją przejmowania ciepła przy użyciu mikrostrug. Niniejszy artykuł przedstawia projekt i testy prototypu, wymiennika ciepła typu mikrostrugowego. Modułowa konstrukcja wymiennika umożliwia zmianę wymiarów geometrycznych, a także zmianę materiału przegrody wymiennika ciepła. Metoda graficzna Wilsona została z zastosowana w celu określenia...
-
Badania eksperymentalne U-rurowego wymiennika ciepła z turbulizacją pasywną
PublikacjaArtykuł dotyczy badań eksperymentalnych wymiennika U-rurowego. W wymienniku została zastosowana turbulizacja pasywna w postaci spiralnej wkładki. Artykuł zawiera opis stanowiska oraz wstępne wyniki badań.
-
Badania eksperymentalne intensyfikacji wymiany ciepła wymiennika U-rurowego z wykorzystaniem turbulizatora helikoidalnego
PublikacjaW niniejszej pracy zostały zaprezentowane możliwości intensyfikacji wymiany ciepła po stronie płaszcza wymiennika U-rurowego. Badania eksperymentalne zostały przeprowadzone zarówno dla wymienników referencyjnych tj. prosty – rura w rurze, U-rurowy bez turbulizacji jak i wymiennika z turbulizatorem helikoidalnym. Dla konstrukcji rura w rurze w celu uzyskania wartości referencyjnych przeprowadzono pomiary w układzie woda-woda oraz...
Rok 2016
-
Wyznaczanie współczynnika wymiany ciepła metodą Wilsona w kompaktowym mikrostrugowym wymienniku ciepła
PublikacjaArtykuł przedstawia konstrukcję prototypowego, modułowego mikrostrugowego wymiennika ciepła. Przeprowadzone badania cieplno-przepływowe w układzie woda-woda, umożliwiają określenie efektywności wymiany ciepła, charakterystyk cieplno przepływowych, oraz wielkości współczynnika przejmowania ciepła. Przeprowadzone eksperymenty posłużyły do weryfikacji stosowalności istniejących korelacji opisujących wymianę ciepła w obszarze uderzającej...
-
Wpływ właściwości czynników chłodniczych na straty egzergii w pompie ciepła (Influence of Refrigerants Properties for Exergy Losses in Heat Pump)
PublikacjaArtykuł poświęcony jest wpływowi występujących w pompie ciepła strat egzergii na jej efektywność energetyczną, a co za tym idzie koszty funkcjonowania instalacji. Autorzy prezentują tu metodologię obliczeniową, która może być zastosowana w procesach projektowania układów cieplno-przepływowych. Obliczenia zostały wykonane na podstawie typowego układu powietrznej pompy ciepła pracującej w klimacie środkowo-europejskim. Ponadto w...
-
Wpływ ekologicznych czynników roboczych na efektywność układu sprężarkowej pompy ciepła (The impact of environmentally friendly refrigerants on heat pump efficiency)
PublikacjaArtykuł poświęcony jest zagadnieniu symulacji pracy układu sprężarkowej pompy ciepła. Prawidłowe zaprojektowanie instalacji oraz jej właściwe użytkowanie pozwala na zmniejszenie kosztów eksploatacji. Dokładna analiza techniczno-ekonomiczna umożliwia natomiast dobór elementów systemu o możliwie największej sprawności, a zatem niskim zapotrzebowaniu na energię. Zastosowanie układów opartych o perspektywiczne, proekologiczne czynniki...
-
Wizualizacja dwufazowego przepływu adiabatycznego: podstawy teoretyczne i budowa stanowiska pomiarowego.
PublikacjaW artykule zaprezentowano stanowisko przeznaczone do wizualizacji przepływu adiabatycznego. W założeniach do jego konstrukcji autorzy przyjęli jako priorytet walor wizualizacyjny, czyli możliwość realizacji pokazów, a również rzeczywistej pracy instalacji zapewniającej prowadzenie pomiarów laboratoryjnych.
-
Raport z oględzin technicznych Chillera NECS/B 1314 celem określenia przyczyn wystąpienia jego częściowej awarii .
PublikacjaAutorzy niniejszego raportu dokonali dokładnych oględzin stanu faktycznego urządzenia NECS/B 1314. Nie stwierdzono nieprawidłowości pracy układu diagnostycznego urządzenia. Urządzenie jest zainstalowane na właściwym podłożu i we właściwym otoczeniu zgodnie z postanowieniami normy EN378-1 dotyczącymi bezpieczeństwa instalacji wykorzystujących czynniki chłodnicze. Należy podkreślić że wytwornica wody lodowej znajduje się na zewnątrz,...
-
Pressure drop of HFE7000 and HFE7100 during flow condensation in minichannels
PublikacjaAttention is focused on the issues of flow resistance and pressure drop of perspective refrigeration fluids during condensation in the two-phase flow in minichannels. The case of the flow through a cylindrical single channel of 2.3 mm inner diameter was carefully analyzed. Pressure drop tests have been performed in diabatic flow conditions. The effect of heat flux, mass flux, vapour quality and saturation temperature on the two-phase...
-
Performance analyses of helical coil heat exchangers. The effect of external coil surface modification on heat exchanger effectiveness
PublikacjaThe shell and coil heat exchangers are commonly used in heating, ventilation, nuclear industry, process plant, heat recovery and air conditioning systems. This type of recuperators benefits from simple construction, the low value of pressure drops and high heat transfer. In helical coil,centrifugal force is acting on the moving fluid due to the curvature of thetube results in the development. It has been long recognized that the...
-
Opracowanie studium wykonalności zamierzenia inwestycyjnego pn.: „Zasobnik ciepła ze stratyfikacją termiczną”
PublikacjaMożna zauważyć wyraźną dysproporcję pomiędzy poziomem komplikacji technicznej wśród producentów krajowych i w firmach zagranicznych. Przedsiębiorstwa zagraniczne z reguły wykorzystują m.in. wężownice wykonane z rur karbowanych lub ożebrowanych w zasobnikach ciepła często można spotkać również zmienna geometrię wężownicy oraz zmodyfikowane układy „ładowania” i ”rozładowywania” zasobnika. Wśród krajowych firm dominują konstrukcję...
-
Nowe czynniki chłodnicze i zmiany w instalacjach chłodniczych. Cz.3
PublikacjaArtykuł jest kontynuacją tematyki przedstawionej w części pierwszej (nr 9 -2015) oraz części drugiej (nr 10-2015). Autorzy nawiązują do konsekwencji jakie niosą ze sobą ograniczenia stosowania syntetycznych czynników chłodniczych z grupy CFC i HFC. W artykule przedstawiono analizę wpływu rodzaju czynnika chłodniczego na efektywność sprężarkowego układu chłodzenia przeznaczonego do współpracy z komorą chłodniczą do przechowywania...
wyświetlono 3967 razy