Filtry
wszystkich: 6765
wybranych: 5212
-
Katalog
- Publikacje 5212 wyników po odfiltrowaniu
- Czasopisma 47 wyników po odfiltrowaniu
- Konferencje 24 wyników po odfiltrowaniu
- Osoby 78 wyników po odfiltrowaniu
- Projekty 7 wyników po odfiltrowaniu
- Kursy Online 30 wyników po odfiltrowaniu
- Wydarzenia 3 wyników po odfiltrowaniu
- Dane Badawcze 1364 wyników po odfiltrowaniu
Filtry wybranego katalogu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: HIGH-VOLTAGE TRANSFORMERS
-
Voltage Harmonics Transfer through Medium Voltage Instrument Transformers
PublikacjaVoltage transformers are widely used in power quality monitoring systems in medium and high voltage grids. This paper presents accuracy problems related to voltage harmonics transfer through instrument transformers. A simplified lumped-parameters wideband circuit model of the voltage transformer is proposed and verified by simulation and experimental investigations. A number of voltage transformers have been tested in the frequency...
-
Voltage Transients Transfer over Medium Voltage Instrument Transformers
PublikacjaThis paper presents voltage harmonic transfer accuracy problems through voltage transformers which are used in power quality monitoring systems in medium and high voltage grids. A simplified lumped parameters circuit model of the voltage transformer is proposed and verified by simulation and experimental investigations. A number voltage transformers typically used in medium voltage grid has been tested in the conducted disturbances...
-
High voltage protective assembly.
PublikacjaW referacie opisano zestaw zabezpieczeniowy, składający się z bezpiecznika i ogranicznika przepięć, przeznaczony dla napowietrznych słupowych stacji transformatorowych średnich napięć. Zastosowany warystorowy ogranicznik przepięć spełnia jednocześnie rolę wspornika dla bezpiecznika gazowydmuchowego. W referacie przedstawiono budowę, podstawowe parametry, przykłady zastosowania oraz wyniki badań zwarciowych zestawu.
-
A Development of a Capacitive Voltage Divider for High Voltage Measurement as Part of a Combined Current and Voltage Sensor
PublikacjaThis article deals with the development of capacitive voltage divider for high voltage measurements and presents a method of analysis and optimization of its parameters. This divider is a part of a combined voltage and current sensor for measurements in high voltage power networks. The sensor allows continuous monitoring of the network distribution status and performs a quick diagnosis and location of possible network failures....
-
High - voltage thin - layer fuses
PublikacjaZaprezentowano nową technologię i konstrukcję bezpieczników wysokonapięciowych wykorzystując technologie stosowane w mikroelektronice. Cienką warstwę topika naniesiono na quasiceramiczne podłoże. Wykonane modele bezpieczników charakteryzują się wysoką pewnością działania oraz małymi stratami I2t.
-
Improving sensitivity of residual current transformers to high frequency earth fault currents
PublikacjaFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when high frequency earth fault current occurs. Serious hazard of electrocution exists then. In order to detect such a current, it is necessary to modify parameters of residual current devices, especially the operating point of their current transformer. The authors proposed...
-
Diagnostics of high-voltage varistors by acoustic emission
PublikacjaWarystory, szeroko stosowane w ogranicznikach przepięć, powinny być testowane na końcowym etapie ich wytwarzania. Stosowane metody testowania wymagają użycia wysokich napięć i prądów o dużych natężeniach, co jest nidogodne, destrukcyjne i wymaga poboru relatywnie dużych pocy. W artykule zaproponowano zastosowanie analizy sygnału emisji akustycznej do predykcji jakości struktury warystora. Opisano system przygotowany do tej aplikacji,...
-
A Combined TOPSIS and FA Based Strategic Analysis of Technical Condition of High Power Transformers
PublikacjaThe paper presents mathematical model { TOPSIS method, which was utilized on insulating state of distribution transformer to analyze and sensibility of individual measurements methods mutual comparison. We can uniquely determine the importance of these measurements methods with this mathematical appara- tus in these measurements methods in insulating state of transformers.
-
Determination of Complex Permeability of Silicon Steel for Use in High-Frequency Modeling of Power Transformers
Publikacja -
Modification of the operating point of residual current transformers for high frequency earth fault currents detection
PublikacjaFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when earth fault current with high frequency components occurs. Serious hazard of electrocution exists then. One of the most important element of residual current devices is a residual current transformer with iron core. Tripping characteristic of residual current devices strictly...
-
Classification of high-voltage varistors into groups of differentiated quality
PublikacjaThe research was aimed on defining a factor of quality for high-voltage varistors using Non-Destructive Testing (NDT) techniques, which could be applied during the production testing. The newly proposed parameter Q determined on the basis of the lowest resonant frequency fr measured within the preselected frequency range was taken into account. The parameter Q was defined for ZnO structures after firing, without metallized contacts....
-
Resonant ultrasonic spectroscopy in high-voltage varistor spectroscopy
PublikacjaResonant spectroscopy is an effective non-destructive testing method focused on defects in tested objects. The testing procedure, based on the resonant pattern, allows rejection of the tested samples with defects which do not fit the pattern. A sweeping frequency method has been used to measure the spectrum of resonances in high-voltage varistors. As a result we can observe resonances that depend directly on inhomogeneity of the...
-
A High-Efficient Low-Voltage Rectifier for CMOS Technology
PublikacjaA new configuration of rectifier suiting CMOS technology is presented. The rectifier consists of only two nchannel MOS transistors, two capacitors and two resistors; for this reason it is very favourable in manufacturing in CMOS technology. With these features the rectifier is easy to design and cheap in production. Despite its simplicity, the rectifier has relatively good characteristics, the voltage and power efficiency, and...
-
Quality assessment of high voltage varistors by third harmonic index
PublikacjaHigh voltage varistors that consist of grained ZnO have to be tested before assembling into a surge arrester. The existing methods demand a usage of high voltages and intensive currents that is inconvenient, destructive and needs extensive power consumption. Additionally, these methods require metallization of the prepared varistor structures that increases costs. We propose another method of varistors quality assessments by a...
-
Third harmonic index as a diagnostic tool of high-voltage varistors
PublikacjaThe recommended methods for standard testing of high-voltage varistors demand application of high voltages and intensive currents that is inconvenient and needs extensive power consumption. These methods require metallization of the prepared ZnO structures that increases costs of testing. Another method of varistor quality and endurance evaluation by the third harmonic index measurement at relatively low voltage range has been...
-
The Issues of Reactive Power Compensation in High-voltage Transmission Lines
PublikacjaThis paper discusses the selection of compensation shunt reactors for a double-circuit 400 kV transmission line using the example of the newly built Elk Bis – Alytus transmission line. The analysis takes into account various conditions of the power system. The published results relate to voltage levels in steady states and during switching processes and short circuits.
-
New Architecture of Solid-State High-Voltage Pulse Generators
PublikacjaThe application of the nanosecond pulsed electric field (nsPEF) for biomedical treatments has gained more interest in recent decades due to the development of pulsed power technologies which provides the ability to control the electric field dose applied during tests. In this context, the proposed paper describes a new architecture of solid-state high-voltage pulse generators (SSHVPG) designed to generate fully customised sequences...
-
Analysis of pressure ratio in the intake in dependence on high-voltage behaviours
PublikacjaPower control in spark ignition engines by regulating the intake air is performed. The control unit needs information about the air pressure conditions which then enters the combustion chamber. The information about the intake air pressure is an important quantity for optimal control of combustion mixtures. The paper describes some types of sensors that are used to measure the air intake temperature. Air pressure in the intake...
-
Improving Accuracy of Respiratory Rate Estimation by Restoring High Resolution Features With Transformers and Recursive Convolutional Models
PublikacjaNon-contact evaluation of vital signs has been becoming increasingly important, especially in light of the COVID- 19 pandemic, which is causing the whole world to examine people’s interactions in public places at a scale never seen before. However, evaluating one’s vital signs can be a relatively complex procedure, which requires both time and physical contact between examiner and examinee. These re- quirements limit the number...
-
Problems of Selecting Protection for Shunt Reactors Working in Extra-High Voltage Grids
PublikacjaThis paper presents difficulties encountered when designing protection devices for shunt reactors connected directly to extra-high voltage grids. Using the example of the 400 kV Ełk Bis substation, it has been demonstrated that protection of a shunt reactor based on equipment using measurements of electrical signals from voltage and current transformers has its limitations and, in some cases, may be insufficient.
-
Evaluative analysis of 2- and 3-level DC/DC converters for high-voltage high-power applications
Publikacja -
The Effect of Protrusions on the Initiation of Partial Discharges in XLPE High Voltage Cables
PublikacjaThis paper is focusing on 3D Finite Elements Analysis (FEA) based modelling of protrusions as defects or imperfections in the XLPE high voltage cable. This study is aiming to examine the impact protrusions have on the initiation of partial discharges. Spherical and ellipsoidal protrusions with different sizes at the conductor screen of the high voltage cable is an essential content of this paper. In addition, a spherical gas-filled...
-
Synchronized six-step voltage generation in high-speed PMSM drive
PublikacjaSynchronized voltage generation has already been considered in the context of pulse width modulation (PWM). References prove that synchronized PWM substantially decreases subharmonics in inverter output voltage when operating with low switching-to-fundamental frequency ratio. This paper identifies problems of unsynchronized voltage generation in electric drives under six-step inverter operation. Guidelines for the synchronization...
-
Diagnostics of high-voltage varistor quality using resonant ultrasound spectroscopy
PublikacjaResonant spectroscopy is an effective nondestructive testing method focused on defects detection in tested objects. Resonance spectrum contains an information about the mechanical properties and particularly about the structural homogeneity of the whole object. A swept frequency method has been used to measure the selected resonant frequencies range. The system for measurement of resonant ultrasound spectroscopy of high-voltage...
-
High power, medium voltage, modular active power filtering system
Publikacja -
The effect of cable duct diameter on the ampacity of high-voltage power cables
PublikacjaThe ampacity of power cables depends, among others, on the conditions of heat dissipation from the cable to the environment. Cables are usually laid directly in the ground, but in some sections, they may be placed in ducts, which adversely affects the ampacity of the cable line. The paper presents heat transfer phenomena for cables installed in pipe-type ducts filled with air. The effect of cable duct diameter on this ampacity...
-
Protection of Earthing Reactor Connected to the Star Point of a High Voltage Shunt Reactor
PublikacjaThe article presents the problem of protection of earthing reactors connected to the star point of shunt reactors in high voltage lines, with particular regard to the detection of internal faults. Model analyses for an actual system commissioned in 2015, which is intended to be provided with earthing reactors, are included.
-
Computer-Aided Calculations of Earth Potential Rise in High Voltage Overhead Lines
PublikacjaHigh voltage overhead power lines with earth wires comprise towers made of conductive material. Some towers are in locations where people can be expected to be either for a long time or for a short time but very frequently. Evaluation of shock hazard near such towers requires calculation of line-to-earth short-circuit current, earth current and especially earth potential rise. Number of towers in high voltage power lines can exceed...
-
Optimization of thermal backfill configurations for desired high-voltage power cables ampacity
PublikacjaThe ampacity of high-voltage power cables depends, among others, on their core cross-sectional area as well as thermal resistivity of the thermal backfill surrounding the cables. The cross-sectional area of the power cables’ core is selected according to the expected power to be transferred via the cable system. Usually, the higher the power transfer required, the higher the cross-sectional area of the core. However, the cost of...
-
Response of high voltage disconnector under seismic excitation - experimental and numerical study
PublikacjaThe efficiency of the energetic infrastructure system is a very import safety issue in the region experienced by the ground motion. The aim of the present paper is to show the results of the experimental and numerical study focused on the earthquake-induced response of the high voltage disconnector, which is an important element of energetic network. First, the impact tests as well as the sweep-sine shaking table tests were conducted....
-
Analysis of Ferroresonance Mitigation Effectiveness in Auxiliary Power Systems of High-Voltage Substations
PublikacjaFerroresonance in power networks is a dangerous phenomenon, which may result in overcurrents and overvoltages, causing damage to power equipment and the faulty operation of protection systems. For this reason, the possibility of the occurrence of ferroresonance has to be identified, and adequate methods need to be incorporated to eliminate or reduce its effects. The aim of this paper is to evaluate the effectiveness of ferroresonance...
-
Electrical Tree Growth Behavior Under AC and DC High Voltage in Power Cables
PublikacjaThis work investigates the impact of an applied AC and DC high voltage on the electrical tree behavior in extruded cross-linked polyethylene (XLPE) insulation based on simulation and experimental validation. Extensive partial discharge (PD) testing methods are being implemented for high voltage cables under AC voltage for monitoring their condition. However, these PD testing methods cannot be utilized for power cables under DC...
-
Computer-aided Analysis of Induced Sheath Voltages in High Voltage Power Cable System
PublikacjaThis paper concerns the effect of configuration of high voltage power cables on induced voltages in their metallic sheaths. One, two or three cables per phase and phase sequence of the cables are considered. Computing of the voltages was performed for a normal operation and in case of earth fault. Various ways of the sheaths bonding are considered as well. Shock hazard and voltage stress of non-metallic outer sheath of cables are...
-
Case studies of resonance phenomena in high voltage overhead power lines with shunt reactors
PublikacjaMisguided design of the towers of power transmission lines can lead to serious problems such as voltage asymmetry, overvoltages, electric arc extinction difficulties or resonance – in case of double circuit line with shunt reactors. The paper points out those threats on example of 400 kV double circuit overhead transmission line with shunt reactors.
-
Safety issues referred to induced sheath voltages in high-voltage power cables – case study
PublikacjaLoad currents and short-circuit currents in high-voltage power cable lines are sources of the induced voltages in the power cables’ concentric metallic sheaths. When power cables operate with single-point bonding, which is the simplest bonding arrangement, these induced voltages may introduce an electric shock hazard or may lead to damage of the cables’ outer non-metallic sheaths at the unearthed end of the power cable line. To...
-
Application of 3D graphic software and GIS in visual impact assessment of high-voltage overhead transmission lines
Publikacja -
Magnetic and capacitive couplings influence on power losses in double circuit high voltage overhead transmission line
PublikacjaPurpose – The paper aims to discuss problems of power and energy losses in a double-circuit overhead transmission line. It was observed from energymeters’ readings, that in such a line, active power losses can be measured as “negative”. The “negative” active power losses appear when the active power injected to the circuit is lower than the active power received at the circuit end. The purpose of this paper is to explain this phenomenon. Theoretical...
-
Magnetic and capacitive couplings influence on power and energy measurement in double circuit high voltage overhead transmission line
PublikacjaThe paper discusses influence of magnetic and capacitive couplings on power and energy measurement in case of double circuit high voltage overhead transmission line. There are presented and discussed various factors influencing the power flow among the line‟s circuits. Mathematical model based calculations results are compared to the real transmission line measurements.
-
Analysis of Induced Voltages and Power Losses in High Voltage Power Cables for Selected Methods of Cables Sheaths Bonding
PublikacjaPower is increasingly supplied to city centres with 110 kV cable lines. This is a convenient way to supply power, and practically the only one possible in areas of dense urban development. A high-voltage cable contains a coaxial metallic sheath, in which in normal operation and in fault conditions (during short-circuits) significant line-to-earth voltages can be induced, which threatens electric shock and/or damage to the cable’s...
-
The Finite Elements Method application to assesment the impact of turbulence generated by wind turbines on their lacation inclose proximity of overhead high voltage power transmissionlines
PublikacjaThe paper presents selected aspects of construction of wind turbines location concerning aerodynamic impact on power lines. Reaserch is based on the source data concerning the aerodynamic impact of a wind farm consisting of 8 turbines and 400 kV power line, an analysis of the possibility of wind farm locating in the immediate vicinity of the line was carried out. There are serious problems with locating higher capacity wind farms...
-
Potential of silicon carbide MOSFETs in the DC/DC converters for future HVDC offshore wind farms
Publikacja -
Dynamics of fault arc traveling along busbars in high voltage switchboards = Dynamika łuku zwarciowego przemieszczającego się wzdłuż szyn rozdziel-nic wysokiego napięcia
PublikacjaThe paper presents the results of magnetic induction and electrodynamic force calculations acting on arc column during short-circuit in medium voltage air-insulated bus-bars. The gap between the bars was 120 mm and the prospective short-circuit currents ranged from 4 kA to 8 kA. The paper also shows the measurement results of average velocity fault arc depending on currents arc diameter and arc current was established and described....
-
Voltage Harmonic Distortion Measurement Issue in Smart-Grid Distribution System
PublikacjaThis paper presents the investigation results ofvoltage harmonic transfer accuracy problems through voltagetransformers which are widely used in power quality monitoringsystems in medium and high voltage grids. A simplified lumpedparameters circuit model of the voltage transformer is presentedand verified by simulation and experimental investigations. Anumber voltage transformers typically used in medium voltagegrid has been tested...
-
Dielectric Barrier Discharge Systems with HV Generators and Discharge Chambers for Surface Treatment and Decontamination of Organic Products
PublikacjaThe article presents applications of systems with power electronic converters, high voltage transformers, and discharge chambers used for nonthermal, dielectric barrier discharge plasma treatment of a plastic surface and decontamination of organic loose products. In these installations, the inductance of the high voltage transformers and the capacitances of the electrode sets form resonant circuits that are excited by inverters....
-
Frequency Diagnostics of Transformer Insulating Parameters
PublikacjaIn the article is presented experimental analysis and diagnostics of insulating system oil-paper for power transformers, mainly by progressive frequency method – dielectric spectroscopy. In the 1-st part of the article is described base theory about measurement and diagnostics insulating part (oil and paper) of power transformers. In the 2-nd part of article is described measuring method of insulating frequency diagnostics - frequency...
-
Multi-transformer primary-side regulated flyback converter for supplying isolated IGBT and MOSFET drivers
PublikacjaThis paper presents primary-side voltage regulated multi-transformer quasi-resonant flyback converter (MTFC) for supplying isolated power switch drivers. The proposed topology offers distinct advantages over frequently used flyback converter possessing one high frequency transformer with isolated multiple outputs. Particularly, when a large number of separate dc supply units is required, then MTFC enables improved regular distribution...
-
Power electronic transformer based on cascaded H-bridge converter
PublikacjaIn this paper the control strategy of power electronic transformer (PET) is proposed. The analyzed structure of PET uses two seven-level cascaded H-bridge (CHB) rectifiers. The electrical power of PET is transferred between DC-links of CHB converters using dual-active-bridges (DABs) and low voltage high frequency transformers. The roposed solution allows for controlling the active and reactive power with a low level of harmonic...
-
Power Electronic Transformer For Smart Grid Application
PublikacjaIn this paper the control system of Power Electronic Transformer (PET) for the Smart Grid application is proposed. The structure of PET is based on two Cascaded H-bridge (CHB) converters. The electrical energy is transferred between converters using Dual-Active-Bridges (DAB) and high-frequency transformers. This type of coupling has been used to connect the DC-links of all H-bridges. The proposed control system for PET makes it...
-
Experimental test results of an automatic voltage regulator with independent phase voltage controllers
PublikacjaThe growing number of distributed renewable energy sources and dynamic constant-power loads (e.g. electric vehicle charging stations) pose new challenges for network operators. These changes result in alterations to network load profiles and load flows, leading to greater voltage volatility. One effective solution to these problems can be the use of automatic voltage regulators (AVRs), which stabilize and symmetrize voltage output,...
-
Wielopoziomowe przekształtniki średniego napięcia (SN) o budowie modułowej
PublikacjaW artykule omówiono wybrane zagadnienia dotyczące zastosowań wielopoziomowych przekształtników średniego napięcia (SN) w układach napędowych o regulowanej prędkości, zwłaszcza w układach z izolacją od sieci zasilającej. W opracowanym przekształtniku zastosowano izolację galwaniczną od sieci zrealizowaną za pomocą izolowanych przetwornic dc-dc z transformatorami wysokiej częstotliwości (> 5 kHz). Przedstawiono zarejestrowane przebiegi...