Filtry
wszystkich: 1118
wybranych: 893
Wyniki wyszukiwania dla: X-RAY COMPUTED TOMOGRAPHY
-
Use of X-Ray Computed Tomography for Ice Detection Applied to Organ Cryopreservation
Publikacja -
Ovarian tissue cryopreservation by stepped vitrification and monitored by X-ray computed tomography
Publikacja -
Assessment of the cryoprotectant concentration inside a bulky organ for cryopreservation using X-ray computed tomography
Publikacja -
An optimized controlled rate slow cooling protocol for bovine ovarian tissue cryopreservation by means of X-ray computed tomography
Publikacja -
Bimodal Nd-Doped LuVO4 Nanoprobes Functionalized with Polyacrilic Acid for X-Ray Computed Tomography and NIR Luminescent Imaging
Publikacja -
Application of the X-ray micro computed tomography to the analysis of the structure of polymeric materials
PublikacjaIn this paper the application of X-ray micro-computed tomography (micro-CT) as a non-destructive testing method of polymeric materials is presented. Increasing applicability of polymers in variedend-use industries such as automotive, building and construction, consumer goods, and packaging is propelling the growth of the global polymer processing market. However, controlling of the polymer structure is one of the most important...
-
Experimental investigations of fracture process in concrete by means of x-ray micro-computed tomography
PublikacjaW artykule pokazano doświadczalne wyniki badań procesu pękania w betonie stosując mikro-tomografię. Doświadczenia wykonano dla zginanych belek betonowych. Wyniki doświadczalne modelowano stosując MES na bazie modelu z degradacją sztywności sprężystej z nielokalnym osłabieniem. Beton symulowano jako materiał 4-fazowy. Uzyskano dobra zgodność wyników MES z doświadczeniami.
-
Mechanical and radiation shielding properties of concrete reinforced with boron--basalt fibers using Digital Image Correlation and X--ray micro--computed tomography
PublikacjaThe paper presents experimental investigations of the radiation shielding, mechanical and fracture properties of concrete reinforced with 5 kg/m3 of novel basalt fibers infused with boron oxide (BBF). However, further studies concerning other dosages i.e. 1 kg/m3, 10 kg/m3, 15 kg/m3 and 20 kg/m3 are currently carried out. Experiments with neutron source revealed that addition of BBF as a dispersed concrete reinforcement could improve...
-
Mechanical and fracture properties of concrete reinforced with recycled and industrial steel fibers using Digital Image Correlation technique and X-ray micro computed tomography
PublikacjaPaper presents investigation of fracture phenomenon in plain concrete and in concrete reinforced with both recycled steel fibers (RSF) and industrial steel fibers (ISF). The wedge splitting test (WST), which enables stable crack propagation for quasi-brittle materials, was carried out on 75 75 75 mm cube samples. Initially, fracture process zone development was investigated only on the surface of samples using Digital Image Correlation...
-
Monitoring the fracture process of concrete during splitting using integrated ultrasonic coda wave interferometry, digital image correlation and X-ray micro-computed tomography
PublikacjaThe paper deals with the continuous-time monitoring of mechanical degradation in concrete cubes under splitting. A series of experiments performed with integrated coda wave interferometry (CWI) and digital image correlation (DIC), supported with X-ray micro-computed tomography (micro-CT) is reported. DIC and micro-CT techniques were used to characterize the fracture process in detail. CWI method was proved to be effective in the...
-
Tome-lapse X-ray tomography imaging of flow patterns in versatile silo model
PublikacjaThe paper introduces a new versatile silo model that was especially designed for in situ X-ray tomography studies of silo discharge for various flow conditions, namely concentric and eccentric. The presented work focuses on organic granular materials where low fraction of short-grain white rice is mixed with spheroidal sorghum particles. The high-quality tomography images combined with adequate image processing strategy allows...
-
X-Ray Computer Tomography Study of Degradation of the Zircaloy-2 Tubes Oxidized at High Temperatures
PublikacjaThe investigations of high-temperature oxidation of zirconium alloys, applied for fuel pellets in nuclear power plants, are usually limited to oxidation kinetics, phase transformations and microstructural characterization. The purpose of this research was to characterize the degradation phenomena occurring within oxide layer and at the interface oxide/metal, on internal and external Zircaloy-2 tube...
-
Shear fracture of longitudinally reinforced concrete beams under bending using Digital Image Correlation and FE simulations with concrete micro-structure based on X-ray micro-computed tomography images
PublikacjaThe paper presents experimental and numerical investigations of the shear fracture in rectangular concrete beams longitudinally reinforced with steel or basalt bar under quasi-static three point bending. Shear fracture process zone formation and development on the surface of beams was investigated by Digital Image Correlation (DIC) whereas thorough analyses of 3D material micro-structure, air voids, width and curvature of shear...
-
Analysis of the bulk solid flow during gravitational silo emptying using X-ray and ECT tomography
PublikacjaW pracy przedstawiono wyniki pomiarów zmian koncentracji piasku bezkohezyjnego zachodzących w prostokątnym modelu silosu opróżnianym grawitacyjnie. Pomiary wykonano z zastosowaniem kontynualnego promieniowania rentgenowskiego oraz z użyciem tomografii pojemnościowej. Badania wykonano dla zróżnicowanego zagęszczenia początkowego piasku oraz różnego stopnia szorstkości ścian. Szczególny nacisk położono na zachowanie sie materiału...
-
Quantitative estimation of volume changes of granular materials during silo flow using X-ray tomography.
PublikacjaW artykule przedstawiono wyniki badań doświadczalnych nad zmianami objętościowymi materiału granulowanego podczas przepływu silosowego. Badania wykonano przy zastosowaniu tomografii rentgenowskiej. Wyniki porównano z wynikami doświadczalnymi przy zastosowaniu cyfrowej obróbki zdjęć płynącego materiału.
-
Selection of material for X-ray tomography analysis and DEM simulations: comparison between granular materials of biological and non-biological origins
PublikacjaPhysical properties and X-ray tomography images of five different granular materials: glass bead, glass grit, short grain white rice, sorghum and clay granules (Seramis) are investigated to select the most promising materials for numerical simulations and time-lapse X-ray tomography imaging. The examined materials represent granular materials of non-biological origin (glass bead, glass grit and Seramis) and granular plant materials...
-
Reconstructing human impact on peatland development during the past 200 years in CE Europe through biotic proxies and X-ray tomography
Publikacja -
Internal imaging of concrete fracture based on elastic waves and ultrasound computed tomography
PublikacjaThe condition assessment of concrete structures belongs to the greatest challenges of non-destructive testing. Monitoring the fracture process of concrete and detecting cracks at the earliest possible stage is a vital aspect to ensure the safety of civil engineering objects. The use of ultrasound tomography enables imaging the internal structure of a tested element. This study aims at the visualization of fracture damage in concrete...
-
MODELLING OF CONCRETE FRACTURE AT AGGREGATE LEVEL USING DEM BASED ON X-RAY mu CT IMAGES OF INTERNAL STRUCTURE
PublikacjaThe paper describes two-dimensional meso-scale numerical results of fracture in notched concrete beams under quasi-static three-point bending. Concrete was modelled as a random heterogeneous 4-phase material composed of aggregate particles, cement matrix, interfacial transitional zones (ITZs) and air voids. As a numerical approach, the discrete element method (DEM) was used. The concrete micro-structure in calculations was directly...
-
Wykorzystanie tomografii komputerowej przy analizie jakości zacementowania - migracja gazu
PublikacjaArtykuł przedstawia opis zjawiska znanego w wiertnictwie otworowym jako migracja gazu. Opisano główne przyczyny powstawania tego negatywnego zjawiska polegającego na przepływie gazów a także płynów w zaczynie cementacyjnym lub kamieniu cementowym. Przygotowano próbki imitujące zacementowany odcinek rur okładzinowych. Skupiono się na wykorzystaniu tomografii komputerowej, oraz analizie zrekonstruowanego trójwymiarowego obrazu, w...
-
Analysis of the relationship between cutting forces and local structural properties of Scots pine wood aided by computed tomography
PublikacjaX-ray computed tomography (CT) is utilised in some sawmills today, primarily for enhancing value yield and for process automation, which includes log sorting and sawing optimisation. Nevertheless, there is a scarcity of recent research utilising CT to assess the local cutting process. As a preliminary study, this paper addresses this gap by using CT to investigate the connections between local cutting force and local wood properties...
-
Experimental investigations of damage evolution in concrete during bending by continuous micro-CT scanning
PublikacjaThe paper describes experimental investigation results of fracture in notched concrete beams under quasi-static three-point bending. To visualize 3D fracture in concrete under bending, an extended X-ray micro-computed tomography system was used, i.e. the tomography system SkyScan 1173 was connected to the loading machine ISTRON 5569. This combined system enabled to shot images of deforming concrete beams during a continuous deformation...
-
The Effect of Fly Ash Microspheres on the Pore Structure of Concrete
PublikacjaThe fly ash microspheres (FAMs) formed during the mineral transformation stage in coal combustion are hollow spherical particles with a density less than water. This paper presents the results of X‐ray micro‐computed tomography and an automatic image analysis system of the porosity in the structure of hardened concrete with microspheres. Concrete mixtures with ordinary Portland cement and two substitution rates of cement by microspheres—5%...
-
SIMULATIONS OF FRACTURE IN CONCRETE BEAMS UNDER BENDING USING A CONTINUUM AND DISCRETE APPROACH
PublikacjaThe paper describes two-dimensional meso-scale results of fracture in notched concrete beams under bending. Concrete was modelled as a random heterogeneous 4-phase material composed of aggregate particles, cement matrix, interfacial transitional zones and air voids. Within continuum mechanics, the simulations were carried out with the finite element method based on a isotropic damage constitutive model enhanced by a characteristic...
-
Detection of debonding in reinforced concrete beams using ultrasonic transmission tomography and hybrid ray tracing technique
PublikacjaThis paper concerns inspection of reinforced concrete elements, with particular emphasis on assessing the quality of the adhesive connection between steel and concrete. A novel theoretical model was developed to determine the paths of transmitted, refracted and reflected elastic waves as well as a creeping wave propagated along the inclusion surface. Imaging the internal structure of tested beams was based on wave propagation measurements...
-
EXPERIMENTAL AND NUMERICAL INVESTIGATIONS OF CONCRETE BEHAVIOUR AT MESO-LEVEL DURING QUASI-STATIC SPLITTING TENSION
PublikacjaThe paper describes experimental and numerical results of quasi-static splitting tensile tests on concrete specimens at meso-scale level. The loading strip was made of plywood or steel. Fracture in concrete was detected at the aggregate level by means of three non-destructive methods: 3D x-ray micro-computed tomography, 2D scanning electron microscope and manual 2D digital microscope. The discrete element method was used to directly...
-
Non-uniqueness of fracture parameter choice in simulations of concrete cracking at mesoscale level
PublikacjaIn the paper a non-uniqueness of fracture parameter choice in simulations of cracking process in plain concrete specimens at mesoscale level under monotonic static loading is analysed. The Finite Element Method is used, where cracks are defined in a discrete way using interface cohesive elements with nonlinear material law including softening. The concrete mesostructure (such as: cement matrix, air voids, aggregates, and Interfacial...
-
Imaging of Increasing Damage in Steel Plates Using Lamb Waves and Ultrasound Computed Tomography
PublikacjaThis paper concerns inspection of steel plates, with particular emphasis on the assessment of in-creasing damage. Non-destructive tests were performed on four plates, one of which was un-damaged, while the remaining three had a defects in the form of circular holes with a diameter of 2, 5, and 10 cm. Guided Lamb waves were used in the research, and the image reconstruction was performed using ultrasound computed tomography. The...
-
Mechanical Properties of Additively Manufactured Polymeric Materials—PLA and PETG—For Biomechanical Applications
PublikacjaThe study presented herein concerns the mechanical properties of two common polymers for potential biomedical applications, PLA and PETG, processed through fused filament fabrication (FFF)—Material Extrusion (ME). For the uniaxial tension tests carried out, two printing orientations—XY (Horizontal, H) and YZ (Vertical, V)—were considered according to the general principles for part positioning, coordinates, and orientation typically...
-
Insight into the microstructural and durability characteristics of 3D printed concrete: Cast versus printed specimens
PublikacjaThis study presents the comparison of microstructural and durability characteristics of 3D printed concrete (3DPC) depending on its production method (printing or casting). Printed samples with different numbers of layers, as well as a cast specimen with an identical mix composition, were produced and compared, with their microstructural pore and solid characteristics quantitatively and qualitatively investigated. For this purpose,...
-
Investigations on fracture in reinforced concrete beams in 3-point bending using continuous micro-CT scanning
PublikacjaThis study explores a fracture process in rectangular reinforced concrete (RC) beams subjected to quasi-static three-point bending. RC beams were short and long with included longitudinal reinforcement in the form of a steel or basalt bar. The ratio of the shear span to the effective depth was 1.5 and 0.75. The focus was on the load–deflection diagram and crack formation. Three-dimensional (3D) analyses of the size and distribution...
-
Adaptive Hounsfield Scale Windowing in Computed Tomography Liver Segmentation
PublikacjaIn computed tomography (CT) imaging, the Hounsfield Unit (HU) scale quantifies radiodensity, but its nonlinear nature across organs and lesions complicates machine learning analysis. This paper introduces an automated method for adaptive HU scale windowing in deep learning-based CT liver segmentation. We propose a new neural network layer that optimizes HU scale window parameters during training. Experiments on the Liver Tumor...
-
Novel method of lung area extraction in chest perfusion computed tomography
PublikacjaChest perfusion computed tomography (pCT) is a useful technique in the medical diagnosis of how organs function. Perfusion CT scans are used to calculate perfusion parameters. In the case of automated methods of lung perfusion parameters calculation, the prior extraction of the lung area is desired to avoid unnecessary calculation in an area outside the lung cross-section and to avoid wasting time on processing signals of no diagnostic...
-
Abdominal Aortic Aneurysm segmentation from contrast-enhanced computed tomography angiography using deep convolutional networks
PublikacjaOne of the most common imaging methods for diagnosing an abdominal aortic aneurysm, and an endoleak detection is computed tomography angiography. In this paper, we address the problem of aorta and thrombus semantic segmentation, what is a mandatory step to estimate aortic aneurysm diameter. Three end-to-end convolutional neural networks were trained and evaluated. Finally, we proposed an ensemble of deep neural networks with underlying...
-
Usefulness of chest perfusion computed tomography in the diagnosis of diabetic pulmonary microangiopathy
PublikacjaThis paper presents the usefulness of perfusion computed tomography (pCT) in the diagnosis of diabetic pulmonary microangiopathy. Our previous works have shown that perfusion parameters are useful in the diagnosis of diabetic pulmonary microangiopathy. We are looking for such measurements and perfusion parameters that provide the most accurate diagnosis. Two types of comparison were made based on the results of clinical trials:...
-
Enhancing Renal Tumor Detection: Leveraging Artificial Neural Networks in Computed Tomography Analysis
PublikacjaRenal cell carcinoma is one of the most common cancers in Europe, with a total incidence rate of 18.4 cases per 100 000 population. There is currently significant overdiagnosis (11% to 30.9%) at times of planned surgery based on radiological studies. The purpose of this study was to create an artificial neural network (ANN) solution based on computed tomography (CT) images as an additional tool to improve the differentiation of...
-
Investigation of energy deposition and its optical imaging in polymer gel dosimeters
PublikacjaThis following chapter describes methods for verifying the absorbed dose during radiotherapy. Special attention is paid to the method using polymer-gel dosimeters, the dose reading of which is performed by means of Laser Computed Tomography. The chapter also includes considerations on alternative solutions for dosimetric measurements and various types of radiotherapy and their pros and cons. In addition, both the methods of structural...
-
Role of quantitative chest perfusion computed tomography in detecting diabetic pulmonary microangiopathy
PublikacjaAims: Aimof the study was to determine the role of perfusion chest computed tomography(pCT) in evaluation of pulmonary diabetic angiopathy.Methods: 18 never-smoking patients (10 diabetic patients and 8 healthy controls) underwentchest high resolution CT (HRCT) and then pCT scanning. In both groups, blood tests,biochemical analysis, fibrinogen, HbA1c, spirometry, diffusion capacity for carbonmonoxide(DLCO) and body pletysmography...
-
Assessment of particular abdominal aorta section extraction from contrast-enhanced computed tomography angiography
PublikacjaThe aim of this work is to improve the accuracy of extraction of a particular abdominal aorta section and to reduce the distortion in three-dimensional Computed Tomography Angiography (CTA) images. Imaging modality and quality plays crucial role in the medical diagnostic process, thus ensuring high quality of images is essential at every stage of acquisition and processing.Noise is defined as a disturbance of the image quality...
-
Soft Tissue Retraction Maneuver in Cone Beam Computed Tomography Prior to Crown-Lengthening Procedure—A Technical Note
PublikacjaBackground: An accurate determination of the biological width and the relationship of the cemento-enamel junction with the border of the alveolar bone is crucial during a clinical crown-lengthening (CCL) procedure. The aim of this study was to present a technical note about the retraction techniques in cone beam computed tomography (CBCT) prior to CCL, highlighting the significant enhancement in procedural accuracy and predictability...
-
Computed tomography indicators of cerebral microperfusion improve long term after carotid stenting in symptomatic patients
PublikacjaOBJECTIVES: We tested the hypothesis that computed tomography (CT) perfusion markers of cerebral microcirculation would improve 36 months after internal carotid artery stenting for symptomatic carotid stenosis while results obtained 6-8 weeks after the stenting procedure would yield a predictive value. METHODS: We recruited consecutive eligible patients with >70% symptomatic carotid stenosis with a complete circle of Willis and...
-
Morphometric evaluation of the delayed cerebral arteries response to acetazolamide test in patients with chronic carotid artery stenosis using computed tomography angiography
PublikacjaBackground: The evidence accumulates that the response to acetazolamide test is delayed on the ipsilateral side to stenosis. However, the effect of acetazolamide beyond 30 minutes after acetazolamide administration remains unknown. The aim of this study was to assess the diameters of: anterior cerebral arteries (ACAs), middle cerebral arteries (MCAs) and posterior cerebral arteries (PCAs) before and 60 minutes after the acetazolamide...
-
Intracranial hemorrhage detection in 3D computed tomography images using a bi-directional long short-term memory network-based modified genetic algorithm
PublikacjaIntroduction: Intracranial hemorrhage detection in 3D Computed Tomography (CT) brain images has gained more attention in the research community. The major issue to deal with the 3D CT brain images is scarce and hard to obtain the labelled data with better recognition results. Methods: To overcome the aforementioned problem, a new model has been implemented in this research manuscript. After acquiring the images from the Radiological...
-
The effect of impacted third molars on second molar external root resorption, a cross-sectional cone beam computed tomography study
PublikacjaBackground: Third molars have the highest prevalence of impaction in teeth and can cause pathological damage on the adjacent second molars. This study aims to evaluate the effects of factors related to impacted third molars on external root resorption (ERR) in adjacent second molars using cone-beam computed tomography (CBCT). Material and Methods: In CBCTs, the effect of impacted third molars on the root surface of adjacent second...
-
Lung perfusion parameters in the diagnosis of diabetic pulmonary microangiopathy
PublikacjaThis paper presents the role of perfusion computed tomography (pCT) in the diagnosis of diabetic pulmonary microangiopathy. Our previous works have shown that perfusion parameters are useful in the diagnosis of diabetic pulmonary microangiopathy. In this article we focus on conditions that are necessary for such the diagnosis and introduce method of classification no microangiopathy vs. microangiopathy based on logistic regression....
-
Computational Methods for Liver Vessel Segmentation in Medical Imaging: A Review
PublikacjaThe segmentation of liver blood vessels is of major importance as it is essential for formulating diagnoses, planning and delivering treatments, as well as evaluating the results of clinical procedures. Different imaging techniques are available for application in clinical practice, so the segmentation methods should take into account the characteristics of the imaging technique. Based on the literature, this review paper presents...
-
Non-Destructive Assessment of Masonry Pillars using Ultrasonic Tomography
PublikacjaIn this paper, a condition assessment of masonry pillars is presented. Non-destructive tests were performed on an intact pillar as well as three pillars with internal inclusions in the form of a hole, a steel bar grouted by gypsum mortar, and a steel bar grouted by cement mortar. The inspection utilized ultrasonic stress waves and the reconstruction of the velocity distribution was performed by means of computed tomography. The...
-
Comparison of image pre-processing methods in liver segmentation task
PublikacjaAutomatic liver segmentation of Computed Tomography (CT) images is becoming increasingly important. Although there are many publications in this field there is little explanation why certain pre-processing methods were utilised. This paper presents a comparison of the commonly used approach of Hounsfield Units (HU) windowing, histogram equalisation, and a combination of these methods to try to ascertain what are the differences...
-
Three-dimensional modeling and automatic analysis of the human nasal cavity and paranasal sinuses using the computational fluid dynamics method
PublikacjaPurpose The goal of this study was to develop a complete workflow allowing for conducting computational fluid dynam- ics (CFD) simulation of airflow through the upper airways based on computed tomography (CT) and cone-beam computed tomography (CBCT) studies of individual adult patients. Methods This study is based on CT images of 16 patients. Image processing and model generation of the human nasal cavity and paranasal sinuses...
-
Study of the Layer-Type BST Thin Film with X-ray Diffraction and X-ray Photoelectron Spectroscopy
PublikacjaIn the present paper, results of X-ray photoelectron studies of electroceramic thin films of barium strontium titanate, Ba1xSrxTiO3 (BST), composition deposited on stainless-steel substrates are presented. The thin films were prepared by the sol-gel method. A spin-coating deposition of BST layers with different chemical compositions was utilized so the layer-type structure of (0-2) connectivity was formed. After the deposition,...