Wyniki wyszukiwania dla: CHEST PERFUSION TOMOGRAPHY
-
Novel method of lung area extraction in chest perfusion computed tomography
PublikacjaChest perfusion computed tomography (pCT) is a useful technique in the medical diagnosis of how organs function. Perfusion CT scans are used to calculate perfusion parameters. In the case of automated methods of lung perfusion parameters calculation, the prior extraction of the lung area is desired to avoid unnecessary calculation in an area outside the lung cross-section and to avoid wasting time on processing signals of no diagnostic...
-
Usefulness of chest perfusion computed tomography in the diagnosis of diabetic pulmonary microangiopathy
PublikacjaThis paper presents the usefulness of perfusion computed tomography (pCT) in the diagnosis of diabetic pulmonary microangiopathy. Our previous works have shown that perfusion parameters are useful in the diagnosis of diabetic pulmonary microangiopathy. We are looking for such measurements and perfusion parameters that provide the most accurate diagnosis. Two types of comparison were made based on the results of clinical trials:...
-
Role of quantitative chest perfusion computed tomography in detecting diabetic pulmonary microangiopathy
PublikacjaAims: Aimof the study was to determine the role of perfusion chest computed tomography(pCT) in evaluation of pulmonary diabetic angiopathy.Methods: 18 never-smoking patients (10 diabetic patients and 8 healthy controls) underwentchest high resolution CT (HRCT) and then pCT scanning. In both groups, blood tests,biochemical analysis, fibrinogen, HbA1c, spirometry, diffusion capacity for carbonmonoxide(DLCO) and body pletysmography...
-
Perfusion computed tomography: 4 cmversus8 cm coverage size in subjects with chronic carotid artery stenosis
PublikacjaOBJECTIVE: The impact of coverage size on global cerebral blood flow (CBF), cerebral blood volume (CBV), mean transit time (MTT) and time to peak (TTP) parameters has not been investigated in patients with chronic carotid artery stenosis. METHODS: 63 patients with stenosis of >70% within a single internal carotid artery and neurological symptoms were randomly assigned to two well-matched groups. Differences in CT perfusion scan...
-
Emphysema affects the number and appearance of solitary pulmonary nodules identified in chest low-dose computed tomography: a study on high risk lung cancer screenees recruited in Silesian District
Publikacja -
Lung perfusion parameters in the diagnosis of diabetic pulmonary microangiopathy
PublikacjaThis paper presents the role of perfusion computed tomography (pCT) in the diagnosis of diabetic pulmonary microangiopathy. Our previous works have shown that perfusion parameters are useful in the diagnosis of diabetic pulmonary microangiopathy. In this article we focus on conditions that are necessary for such the diagnosis and introduce method of classification no microangiopathy vs. microangiopathy based on logistic regression....
-
Computed tomography indicators of cerebral microperfusion improve long term after carotid stenting in symptomatic patients
PublikacjaOBJECTIVES: We tested the hypothesis that computed tomography (CT) perfusion markers of cerebral microcirculation would improve 36 months after internal carotid artery stenting for symptomatic carotid stenosis while results obtained 6-8 weeks after the stenting procedure would yield a predictive value. METHODS: We recruited consecutive eligible patients with >70% symptomatic carotid stenosis with a complete circle of Willis and...
-
Proposal of New Tracer Concentration Model in Lung PCT Study Comparison with Commonly Used Gamma-variate Model
PublikacjaPerfusion computed tomography (pCT) is one of the methods that enable non-invasive imaging of the hemodynamics of organs and tissues. On the basis of pCT measurements, perfusion parameters such as blood flow (BF), blood volume (BV), mean transit time (MTT) and permeability surface (PS) are calculated and then used for quantitative evaluation of the tissue condition. To calculate perfusion parameters it is necessary to approximate...
-
Novel methods for diagnosis of pulmonary microangiopathy in diabetes mellitus
PublikacjaLung microangiopathy is a little known negative influence of diabetes mellitus on the functioning of the lungs. In current medical practice lung microangiopathy is diagnosed by comparing two measurements of lung diffusing capacity - one with the subject standing and one with the subject lying. The necessity to take two measurements is inconvenient. In lung microangiopathy we observe a reduction of diffusing capacity, lung flow...
-
Carotid Artery Stenting and Blood–Brain Barrier Permeability in Subjects with Chronic Carotid Artery Stenosis
PublikacjaFailure of the blood-brain barrier (BBB) is a critical event in the development and progression of diseases such as acute ischemic stroke, chronic ischemia or small vessels disease that affect the central nervous system. It is not known whether BBB breakdown in subjects with chronic carotid artery stenosis can be restrained with postoperative recovery of cerebral perfusion. The aim of the study was to assess the short-term effect...
-
Regional resting state perfusion variability and delayed cerebrovascular uniform reactivity in subjects with chronic carotid artery stenosis
PublikacjaThe aim of this study was to assess regional perfusion at baseline and regional cerebrovascular resistance (CVR) to delayed acetazolamide challenge in subjects with chronic carotid artery stenosis.Sixteen patients (ten males) aged 70.94±7.71 with carotid artery stenosis ≥90% on the ipsilateral side and ≤50% on the contralateral side were enrolled into the study. In all patients, two computed tomography perfusion examinations were...
-
A MEASUREMENT SYSTEM FOR MONITORING CARDIOVASCULAR EVENTS IN SYNCOPE PATIENTS
PublikacjaSyncope phenomena is an abrupt and transient loss of consciousness leading to interruption of awareness of one’s surroundings and falls with risk of injury. Syncope is often followed by complete and usually rapid spontaneous recovery. It is said that half of all individuals experience syncopal event at least once during their life. The condition can occur at any age and happens in people with and without other medical problems....
-
Rating mathematical models for first-pass of tracer in pCT lung studies
PublikacjaThis paper presents a comparison of model based on the Gauss function and the most commonly used Gamma-variate model in perfusion computed tomography (pCT) lung studies. It also verifies whether used model affects value of blood volume parameter. Three mean concentration-time curves were created from actual pCT measurements: arterial input function, blood vessels in lungs and lung parenchyma. On the basis of these mean curves we...
-
Information Extraction from Polish Radiology Reports using Language Models
PublikacjaRadiology reports are vital elements of directing patient care. They are usually delivered in free text form, which makes them prone to errors, such as omission in reporting radiological findings and using difficult-to-comprehend mental shortcuts. Although structured reporting is the recommended method, its adoption continues to be limited. Radiologists find structured reports too limiting and burdensome. In this paper, we propose...
-
Tomography
Czasopisma -
The use of the static thermography in monitoring flap perfusion in breast reconstruction with TRAM flap
PublikacjaThis paper shows results of the static thermography for intraoperative and postoperative imaging of TRAM flap perfusion. The results were compared with the clinical examination of flap perfusion. The study was conducted on a group of 38 female patients who underwent breast reconstruction.
-
Active dynamic thermography method for TRAM flap blood perfusion mapping in breast reconstruction
PublikacjaThis paper presents the new method of the transverse rectus abdominis musculocutaneous flap blood perfusion mapping based on the active dynamic thermography. The method is aimed at aiding a surgeon during breast reconstruction procedure. A pair of dTnorm and t90_10 parameters were used as parametric image descriptors of the flap blood perfusion. The method was tested on 38 patients that were subjected to breast reconstruction procedure....
-
Perfusion (Germany)
Czasopisma -
PERFUSION-UK
Czasopisma -
A CNN based coronavirus disease prediction system for chest X-rays
PublikacjaCoronavirus disease (COVID-19) proliferated globally in early 2020, causing existential dread in the whole world. Radiography is crucial in the clinical staging and diagnosis of COVID-19 and offers high potential to improve healthcare plans for tackling the pandemic. However high variations in infection characteristics and low contrast between normal and infected regions pose great challenges in preparing radiological reports....
-
Dynamic characteristics of interaperitoneal perfusion.
PublikacjaPrzedstawiono wyniki badań laboratoryjnych perfuzyjnego przepływu przez model jamy brzusznej człowieka. Szczególną uwagę zwrócono na techniczne aspekty modelu oraz wyników badań. Omówiono technikę pomiarową oraz przeanalizowano rezultaty pod kątem teorii przepływów przez zbiorniki i reaktory.
-
Comparison of chest compressions with and without LUCAS3 mechanical chest compression system during resuscitation performed by novice physicians
Publikacja -
Shanghai Chest
Czasopisma -
Dual-Energy Computed Tomography in Loosening of Revision Hip Prosthesis
Publikacja -
1D portable optical coherence tomography system
Publikacja—Imaging methods are an expanding branch of technology, which involves data acquisition and analysis of images for research and diagnostics. This paper has been devoted to the description of the optical design for a one-dimensional, portable optical coherence tomography (OCT) system. The Mach-Zehnder interferometer has been designed in the presented study. The description of the construction and applied hardware solutions have...
-
Ultrasonic Tomography of Brick Columns Based on FEM Calculations
PublikacjaUltrasonic tomography is one of the most developed method of non-destructive testing. Despite being used mainly in medicine, it is becoming more and more popular as a method for monitoring of structural elements. It allows to examine the internal structure and technical condition of the tested element. This paper investigates the influence of crosssectional geometry on an obtained tomographic image. Wave propagation signals were...
-
Computer-Aided Diagnosis of COVID-19 from Chest X-ray Images Using Hybrid-Features and Random Forest Classifier
PublikacjaIn recent years, a lot of attention has been paid to using radiology imaging to automatically find COVID-19. (1) Background: There are now a number of computer-aided diagnostic schemes that help radiologists and doctors perform diagnostic COVID-19 tests quickly, accurately, and consistently. (2) Methods: Using chest X-ray images, this study proposed a cutting-edge scheme for the automatic recognition of COVID-19 and pneumonia....
-
Internal imaging of concrete fracture based on elastic waves and ultrasound computed tomography
PublikacjaThe condition assessment of concrete structures belongs to the greatest challenges of non-destructive testing. Monitoring the fracture process of concrete and detecting cracks at the earliest possible stage is a vital aspect to ensure the safety of civil engineering objects. The use of ultrasound tomography enables imaging the internal structure of a tested element. This study aims at the visualization of fracture damage in concrete...
-
Validity of MRI brain perfusion imaging method
PublikacjaW artykule zaprezentowano zbiór analiz dotyczących walidacji metody DSC-MRI. Zbadano wpływ rozmycia, opóźnienia, niskiego SNR bolusa oraz innych możliwych źródeł zakłócających wartość parametru perfuzji. Różne metody uzyskiwania parametrów perfuzji zostały zaprezentowane i porównane.
-
Validity of MRI brain perfusion imaging method
PublikacjaW artykule zaprezentowano zbiór analiz dotyczących walidacji metody DSC-MRI. Zbadano wpływ rozmycia, opóźnienia, niskiego SNR bolusa oraz innych możliwych źródeł zakłócających wartość parametru perfuzji. Różne metody uzyskiwania parametrów perfuzji zostały zaprezentowane i porównane.
-
Limitations of DSC-MRI for quantitative brain perfusion.
PublikacjaArtykuł przedstawia ograniczenia metody DSC-MRI w ilościowej ocenie przepływów mózgowych. W zakresie pięciu różnych grup zagadnień przeprowadzono testy symulacyjne oraz obliczenia na podstawie badań fantomowych i in-vivo. Pokazano i omówiono wyniki badań.
-
Chest Injuries Based on Medical Rescue Team Data
Publikacja -
Application of the X-ray micro computed tomography to the analysis of the structure of polymeric materials
PublikacjaIn this paper the application of X-ray micro-computed tomography (micro-CT) as a non-destructive testing method of polymeric materials is presented. Increasing applicability of polymers in variedend-use industries such as automotive, building and construction, consumer goods, and packaging is propelling the growth of the global polymer processing market. However, controlling of the polymer structure is one of the most important...
-
Gold nanoparticles evaluation using functional optical coherence tomography
PublikacjaThe main object of this research was to assess the ability to characterize the gold nanoparticles using optical modalities like optical coherence tomography. Since the nanoparticles, especially gold one, have been very attractive for medical diagnosis and treatment the amount of research activities have been growing rapidly. The nanoparticles designed for different applications like contrast agents or drugs delivery change the...
-
Microcrystalline diamond film evaluation by spectroscopic optical coherence tomography
PublikacjaThis study has focused on the microcrystalline diamond film (MCD) thickness evaluation. For this purpose, optical coherence tomography (OCT) enhanced by spectroscopic analysis has been used as a method of choice. The average thickness of the tested layer was about 1.5 µm, which is below the standard 2-point OCT resolution. In this case, the usefulness of the spectroscopic analysis was confirmed for the evaluation of the thickness...
-
Quantitative Active Dynamic Thermal IR-Imaging and Thermal Tomography in Medical Diagnostic
PublikacjaPrinciples of Active dynamic thermal (ADT) IR-imaging and Thermal Tomography are described in details. Basic medical applications of this new modality are also discussed.
-
CHEST
Czasopisma -
Estimation of flow for tissue perfusion of nutrient liquids in bioreactor.
PublikacjaPrzedstawione zostały problemy związane z wyznaczaniem pola prędkości w warstwie przyściennej opływanej tkanki miękkiej w bioreaktorze. Warunki brzegowe na powierzchni miękkiej tkanki o właściwościach porowatych zostały w niniejszej pracy sformułowane.
-
Efficient signal processing in spectroscopic optical coherence tomography
PublikacjaSpectroscopic optical coherence tomography (SOCT) is an extension of a standard OCT technique, which allows to obtain depth-resolved, spectroscopic information on the examined sample. It can be used as a source of additional contrast in OCT images e.g. by encoding certain features of the light spectrum into the hue of the image pixels. However, SOCT require computation of time-frequency distributions of each OCT A-scan, what is...
-
Detection of petroleum products using optical coherence tomography
PublikacjaIn this work, we present a novel method developed for the analysis of the properties of thin layers for detecting petroleum products on a water surface using a commercially available optical coherence tomography (OCT) system. The spectral density analysis of the signal from a spectroscopic OCT (S-OCT) enables us to perform the precision calculation of the thin layer thickness and other properties like homogeneity, and dispersion,...
-
Nanoparticles displacement analysis using optical coherence tomography
PublikacjaOptical coherence tomography (OCT) is a versatile optical method for cross-sectional and 3D imaging of biological and non-biological objects. Here we are going to present the application of polarization sensitive spectroscopic OCT system (PS-SOCT) for quantitative measurements of materials containing nanoparticles. The PS-SOCT combines the polarization sensitive analysis with time-frequency analysis. In this contribution the benefits...
-
Non-Destructive Assessment of Masonry Pillars using Ultrasonic Tomography
PublikacjaIn this paper, a condition assessment of masonry pillars is presented. Non-destructive tests were performed on an intact pillar as well as three pillars with internal inclusions in the form of a hole, a steel bar grouted by gypsum mortar, and a steel bar grouted by cement mortar. The inspection utilized ultrasonic stress waves and the reconstruction of the velocity distribution was performed by means of computed tomography. The...
-
Parallel multithread computing for spectroscopic analysis in optical coherence tomography
PublikacjaSpectroscopic Optical Coherence Tomography (SOCT) is an extension of Optical Coherence Tomography (OCT). It allows gathering spectroscopic information from individual scattering points inside the sample. It is based on time-frequency analysis of interferometric signals. Such analysis requires calculating hundreds of Fourier transforms while performing a single A-scan. Additionally, further processing of acquired spectroscopic information...
-
Polarization-sensitive optical coherence tomography for ceramic materials inspection
PublikacjaCeramics production is looking for a fast, reliable and non-destructive method that can be implemented on site for defect detection and analysis. In this paper we present polarization-sensitive optical coherence tomography (PS-OCT) as a method for defect inspection. Proposed extensions to standard OCT provide additional information for complete characterization of tested object. We compare OCT and microscope imaging that can easily...
-
Optical Coherence Tomography for nanoparticles quantitative characterization
PublikacjaThe unique features of nanocomposite materials depend on the type and size of nanoparticles, as well as their placement in the composite matrices. Therefore the nanocomposites manufacturing process requires inline control over certain parameters of nanoparticles such as dispersion and concentration. Keeping track of nanoparticles parameters inside a matrix is currently a difficult task due to lack of a fast, reliable and cost effective...
-
CLINICS IN CHEST MEDICINE
Czasopisma -
Chest Disease Reports
Czasopisma -
Journal of Chest Surgery
Czasopisma -
Adaptive Hounsfield Scale Windowing in Computed Tomography Liver Segmentation
PublikacjaIn computed tomography (CT) imaging, the Hounsfield Unit (HU) scale quantifies radiodensity, but its nonlinear nature across organs and lesions complicates machine learning analysis. This paper introduces an automated method for adaptive HU scale windowing in deep learning-based CT liver segmentation. We propose a new neural network layer that optimizes HU scale window parameters during training. Experiments on the Liver Tumor...
-
Integration and verification of meteorological observations and NWP model data for the local GNSS tomography
PublikacjaGNSS meteorology applies the Global Navigation Satellite Systems (GNSS) to derive information about the state of the atmosphere (particularly troposphere). The tomography is one of the methods used in GNSS meteorology. The input data of GNSS tomography are the signal troposphere delays, results of GNSS data processing and additionally meteorological observations and Numerical Weather Prediction (NWP) models data. Different types...