Filtry
wszystkich: 2335
-
Katalog
- Publikacje 2040 wyników po odfiltrowaniu
- Czasopisma 44 wyników po odfiltrowaniu
- Konferencje 3 wyników po odfiltrowaniu
- Osoby 40 wyników po odfiltrowaniu
- Projekty 2 wyników po odfiltrowaniu
- Kursy Online 28 wyników po odfiltrowaniu
- Wydarzenia 2 wyników po odfiltrowaniu
- Dane Badawcze 176 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: RESIDUAL DRIFT ASSESSMENT.
-
Machine learning-based prediction of residual drift and seismic risk assessment of steel moment-resisting frames considering soil-structure interaction
PublikacjaNowadays, due to improvements in seismic codes and computational devices, retrofitting buildings is an important topic, in which, permanent deformation of buildings, known as Residual Interstory Drift Ratio (RIDR), plays a crucial role. To provide an accurate yet reliable prediction model, 32 improved Machine Learning (ML) algorithms were considered using the Python software to investigate the best method for estimating Maximum...
-
Performance of Vector-valued Intensity Measures for Estimating Residual Drift of Steel MRFs with Viscous Dampers
PublikacjaViscous Dampers (VDs) are widely used as passive energy dissipation system for improving seismic performance levels especially in retrofitting of buildings. Residual Inter-story Drift Ratio (R-IDR) is another important factor that specifies the condition of building after earthquake. The values of R-IDR illustrates the possibility of retrofitting and repairing of a building. Therefore, this study aims to explore the vector-valued...
-
Advanced Scalar-valued Intensity Measures for Residual Drift Prediction of SMRFs with Fluid Viscous Dampers
PublikacjaMaximum Residual Inter-story Drift Ratio (RIDRmax) plays an important role to specify the state of a structure after severe earthquake and the possibility of repairing the structure. Therefore, it is necessary to predict the RIDRmax of Steel Moment-Resisting Frames (SMRFs) with high reliability by employing powerful Intensity Measures (IMs). This study investigates the efficiency and sufficiency of scalar-valued IMs for predicting...
-
An investigation on residual stress and fatigue life assessment of T-shape welded joints
PublikacjaThis paper aims to quantitatively evaluate the residual stress and fatigue life of T-type welded joints with a multi-pass weld in different direction. The main research objectives of the experimental test were to test the residual stress by changing direction along with multiple wielding passes and determine the fatigue life of the welded joints. The result shows that compressive residual stress increases in the sample gradually...
-
Effects of Welded Pipe-cutting on the Residual Stress Re-Distribution and Engineering Critical Assessment
Publikacja -
Assessment with mechanical Barkhausen effect of residual stress in grain oriented polycrystalline 3% Si-Fe sheet
PublikacjaW tym artykule zostały opisane badania naprężeń resztkowych w blachach wykonanych z 3% si-fe o zorientowanym ziarnie za pomocą mechanicznego efektu barkhausena (mebn). badano blachy o 3 różnych orientacjach ziaren względem głównej osi próbki: 0, 45, 90 stopni. badania mebn przeprowadzano wzbudzając drgania skrętne oraz drgania gięte. zmierzone maksima obwiedni napięcia skutecznego mebn znajdują się dla badanych próbek w regionie...
-
Assessment with mechanical Barkhausen effect of residual stress in grain oriented polycrystalline 3% Si-Fe sheet
PublikacjaZbadano za pomocą mechanicznego efektu Barkhausena poziom napręzeń wewnętrznych w plikrystalicznej płycie z 3% Si-Fe o zorientowanym ziarnie.
-
Corrigendum to “An investigation on residual stress and fatigue life assessment of T-shape welded joints” [Eng. Fail. Anal. 141 (2022) 106685]
PublikacjaThis paper aims to quantitatively evaluate the residual stress and fatigue life of T-type welded joints with a multi-pass weld in different direction. The main research objectives of the experimental test were to test the residual stress by changing direction along with multiple wielding passes and determine the fatigue life of the welded joints. The result shows that compressive residual stress increases in the sample gradually...
-
Seismic Response Analysis of Knee-Braced Steel Frames Using Ni-Ti Shape Memory Alloys (SMAs)
PublikacjaShape Memory Alloys (SMAs) are known as active materials that can be widely used for structural purposes due to their flag-shape behavior under loading and reloading. Their unique characteristics provided a potential solution for civil engi-neers especially to model buildings with the capability of dissipating seismic en-ergy. In this study, the main purpose is to explore the seismic behavior of Knee-Braced Frames (KBFs) and...
-
Active Learning on Ensemble Machine-Learning Model to Retrofit Buildings Under Seismic Mainshock-Aftershock Sequence
PublikacjaThis research presents an efficient computational method for retrofitting of buildings by employing an active learning-based ensemble machine learning (AL-Ensemble ML) approach developed in OpenSees, Python and MATLAB. The results of the study shows that the AL-Ensemble ML model provides the most accurate estimations of interstory drift (ID) and residual interstory drift (RID) for steel structures using a dataset of 2-, to 9-story...
-
Seismic performance evaluation of steel buckling-restrained braced frames including SMA materials
PublikacjaThe permanent deformation of the building after seismic excitations can be determined by the Maximum Residual Interstory Drift Ratio (MR-IDR), which may be used for measuring the damage states. Low-post yield stiffness of the steel buckling-restrained braced frame (BRBF) makes this system vulnerable to large MR-IDR after a severe earthquake event. To overcome this issue, this paper investigates the seismic limit state performances...
-
Seismic response and performance prediction of steel buckling-restrained braced frames using machine-learning methods
PublikacjaNowadays, Buckling-Restrained Brace Frames (BRBFs) have been used as lateral force-resisting systems for low-, to mid-rise buildings. Residual Interstory Drift (RID) of BRBFs plays a key role in deciding to retrofit buildings after seismic excitation; however, existing formulas have limitations and cannot effectively help civil engineers, e.g., FEMA P-58, which is a conservative estimation method. Therefore, there is a need to...
-
Enhancing seismic performance of buckling-restrained brace frames equipped with innovative bracing systems
PublikacjaNowadays, to improve the performance of conventional bracing systems, in which, buckling in the pressure loads is the main disadvantage, the buckling-restrained brace (BRB) is introduced as a solution. In this study, the performance of the BRB system was improved with innovative lateral-resisting systems of double-stage yield buckling-restrained brace (DYB), and a combination of DYB improved with shape memory alloy (SMA) materials...
-
Air flow phenomena in the model of the blind drift
PublikacjaIn the presented paper, Particle Image Velocimetry (PIV) has been used to investigate flow pattern and turbulent structure in the model of blind drift. The presented model exist in mining, and has been analyzed to resolve ventilation issues. Blind region is particularly susceptible to unsafe methane accumulation. The measurement system allows us to evaluate all components of the velocity vector in channel cross-section simultaneously....
-
Application of Multiplicative Drift Correction and Component Correction methods on simulated gas sensor array responses
PublikacjaSensor response drift is one of the most challenging problems in gas-analyzing systems. Such systems, commonly called electronic noses, are expected to be reliable and reproducible in the long term. Due to the drift phenomena, electronic noses usability is limited to the relatively short period of time, and frequent recalibrations of device are required. Because it is very hard to fabricate sensors without drift, this phenomenon...
-
Calibration of the CMS drift tube chambers and measurement of the drift velocity with cosmic rays
Publikacja -
Residual MobileNets
PublikacjaAs modern convolutional neural networks become increasingly deeper, they also become slower and require high computational resources beyond the capabilities of many mobile and embedded platforms. To address this challenge, much of the recent research has focused on reducing the model size and computational complexity. In this paper, we propose a novel residual depth-separable convolution block, which is an improvement of the basic...
-
Residual Current Devices: Selection, Operation, and Testing
PublikacjaIn this book, the idea for residual current protection has been presented. The evolution in construction types of residual current devices, which has taken place over decades, is discussed. Types and functional properties of the contemporary residual current devices are described. The main parameters of these devices, from the point of view of their selection and application, are indicated. Special constructions of the protective...
-
ENVIRONMENTAL MONITORING AND ASSESSMENT
Czasopisma -
ASSESSMENT of PERFORMANCE of UMV (2024)
Kursy Online(W) Assessment of Performance of Unmanned Maritime Vehicles (W-Lecture) - DAPE - WIMiO AP-of-UMV (W) -DAPE - WIMiO The course entitled "Assessment of Performance of Unmanned Maritime Vehicles (W-Lecture)" is conducted for the DAPE WIMiO Students. The AP-of-UMV (W) course is to discuss the following problems: - major areas of application of UMV unmanned maritime vehicles, - sea environment, - types of UMV vehicles, -...
-
Method of determining the residual fluxes in transformer core
PublikacjaThe article presents the method of calculating the residual induction in transformer columns. The method is based on measurement of the magnetic induction in selected points around the transformer core. The values of residual induction are calculated as linear combination of the results of measurement.
-
Low-frequency tripping characteristics of residual current devices
PublikacjaFast development of various types of converters makes their utilization in industry and in domestic installations very common. Due to converters, an earth fault current waveform in modern circuits can be distorted or its frequency can be different than 50/60 Hz. Frequency of earth fault (residual) current influences tripping of residual current devices which are widely used in low voltage systems. This paper presents the behaviour...
-
Microstructure and residual stresses in surface coatings with PTFE reservoirs
PublikacjaThe paper presents the results of experimental study into the microstructure and changes in residual stresses resulting from sliding and rolling/sliding loaded interaction between metallic surface coatings with embedded PTFE reservoirs and various counter faces. It was found that before testing surface coatings had compressive residual stresses. Molybdenum coating with all types of PTFE reservoirs displayed, as a result of testing,...
-
Measurements of electron drift velocity in OCS
PublikacjaWykonano pomiary prędkości dryfu elektronów w funkcji zredukowanego pola elektrycznego E/N. Wyniki tych pomiarów porównano z wynikami pomiarów w CO2 i N2O.
-
Wojciech Wojnowski dr inż.
OsobyUkończył V Liceum Ogólnokształcące w Gdańsku w klasie o profilu matematyczno-fizycznym z wykładowym językiem angielskim. W 2009 roku rozpoczął studia na Wydziale Chemicznym PG na kierunku technologia chemiczna, uzyskując w 2012 roku tytuł inżyniera, a w 2013 tytuł magistra. W latach 2013–2015 studiował sinologię na Uniwersytecie w Nankinie dzięki uzyskaniu Stypendium Rządu ChRL. Po powrocie do Polski w 2015 roku rozpoczął studia...
-
Detection of high frequency current components by residual current devices
PublikacjaThe negative impact of current harmonics on the main components of residual current devices is presented. A solution for the improvement of the operation of residual current devices is proposed.
-
Residual current devices in installations with PV energy sources
PublikacjaThe paper presents the principles of residual current devices (RCDs) application in photovoltaic (PV) installations. Provisions of standards in this regard are commented on, in particular, attention is drawn to the lack of obligation to use of RCDs in PV installations. The issue of the shape of the earth fault current and the level of leakage currents in such installations are discussed. These factors influence the selection of...
-
Tripping limitations of residual current devices in photovoltaic installations
PublikacjaIn electrical installations with photovoltaic sources of energy, earth fault current may comprise alternating current component and direct current component. The waveform shape of this earth fault current mainly depends on the point of the fault and the properties of a photovoltaic power electronics converter. The waveform shape of the current influences operation of protection devices, especially tripping threshold of residual...
-
Residual current devices in electric vehicles charging installations
PublikacjaThe main requirements of national regulations and international standards regarding protection against electric shock in electric vehicle charging installations are presented. The principles of using residual current devices (RCDs) in such installations are discussed. It is pointed out that RCDs are mandatory equipment for safe charging of electric vehicles. It is noted that the standards require the use of RCDs having an appropriate...
-
The effect of current delay angle on tripping of residual current devices
PublikacjaPower electronics converters applied in domestic or similar installations may utilize current delay (phase) angle control to change the level of transferred power. Due to application of such types of converters, earth fault current in the installation may be strongly distorted. The current distortion level depends on a value of current delay angle. This delay angle also influences the tripping threshold of residual current devices....
-
Tripping of F-type RCDs for high-frequency residual currents
PublikacjaResidual current devices (RCDs) are apparatus commonly used for protection against electric shock in low-voltage electrical installations. They protect people in the case of an earth fault or even in the case of direct contact with the live parts. However, to be effective protective devices, RCDs have to detect residual currents of various waveform shapes which appear in modern electrical installations. For this purpose, RCDs are...
-
Tripping of F-type RCDs for High-Frequency Residual Currents
PublikacjaResidual current devices (RCDs) are apparatus commonly used for protection against electric shock in low-voltage electrical installations. They protect people in the case of an earth fault or even in the case of direct contact with the live parts. However, to be effective protective devices, RCDs have to detect residual currents of various waveform shapes which appear in modern electrical installations. For this purpose, RCDs...
-
Requirements for Residual Current Devices Intended for Electric Vehicle Charging Systems
PublikacjaThe properties of residual current devices have been presented from the point of view of their ability to detect a specific shape of the residual current waveform. Moreover, the standard requirements relating to residual current protection used in electric vehicle charging installations have been pointed out. The operating characteristics of the IC-CPD and RDC-DD protections, which are intended for charging electric vehicles in...
-
Improving sensitivity of residual current transformers to high frequency earth fault currents
PublikacjaFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when high frequency earth fault current occurs. Serious hazard of electrocution exists then. In order to detect such a current, it is necessary to modify parameters of residual current devices, especially the operating point of their current transformer. The authors proposed...
-
Electrical safety in low-voltage DC microgrids with B-type residual current devices
PublikacjaResidual current devices (RCDs) are most popular devices used in low-voltage installations for protection against electric shock and fire. In cases of high risk of electric shock the application of RCDs is mandatory. Currently, the spread of local direct current (DC) microgrids is widely considered. This creates new challenges for protective systems, in particular those based on RCDs. The main purpose of the research is to test...
-
Immunity of residual current devices to the impulse leakage current in circuits with variable speed drives
PublikacjaThis paper concerns reliability of supply in variable speed drive circuits with residual current devices. During normal operation of these circuits high value of leakage current causes unwanted tripping of residual current devices. Immunity of residual current devices to the impulse leakage current should be evaluated. The system for testing of residual current devices and results of the test are presented
-
Identification of residual force in static load tests on instrumented screw displacement piles
PublikacjaOccurrence of the so-called residual force of an unknown value significantly disturbs interpretation of static load tests performed on piles equipped with additional measuring instruments. Screw displacement piles are the piling technology in which the residual force phenomenon is very common. Its formation mechanism is closely related to the installation method of this type of piles, which initiates generation of negative pile...
-
Performance of the CMS drift tube chambers with cosmic rays
Publikacja -
Mean drift detection using statistical process control
PublikacjaCelem niniejszego rozdziału jest opisanie narzędzi statystycznej kontroli procesu (ang. Statistical Process Control - SPC), służących do detekcji dryfu wartości średniej w procesie. W oparciu o dane pochodzące z modelu: karty wartości średniej, odchylenia standardowego, karty oparte na testach sekwencyjnych oraz wykładniczo ważonej średniej ruchomej (ang. Exponentially Weighted Moving Average - EWMA), zostały porównane z punktu...
-
ASSESSMENT
Czasopisma -
Modification of the operating point of residual current transformers for high frequency earth fault currents detection
PublikacjaFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when earth fault current with high frequency components occurs. Serious hazard of electrocution exists then. One of the most important element of residual current devices is a residual current transformer with iron core. Tripping characteristic of residual current devices strictly...
-
Behavior of residual current devices at frequencies up to 50 kHz
PublikacjaThe use of residual current devices (RCDs) is obligatory in many types of low-voltage circuits. They are devices that ensure protection against electric shock in the case of indirect contact and may ensure additional protection in the case of direct contact. For the latter purpose of protection, only RCDs of a rated residual operating current not exceeding 30 mA are suitable. Unfortunately, modem current-using equipment supplied...
-
Verification of safety in low-voltage power systems without nuisance tripping of residual current devices
PublikacjaLow-voltage power systems require initial and periodical verification to check the effectiveness of protection against electric shock. As a protection in case of fault, automatic disconnection of supply is most often used. To verify such a protection measure, the earth fault loop impedance or resistance is measured. This measurement is easy to perform in circuits without residual current devices. When residual current devices are...
-
Evaluation of applicability of classic methods of a fault loop impedance measurement to circuits with residual current devices
PublikacjaMeasurement of fault loop impedance in low voltage grids and systems is in most cases performed to verify the effectiveness of protection against electric shock by automatic disconnection of supply. For the sake of measurement accuracy, it is advisable to perform it using large current. Unfortunately, in circuits with residual current devices which are very widely used nowadays, a large measurement current may trigger those devices...
-
Behavior of residual current devices at earth fault currents with DC component
PublikacjaLow-voltage electrical installations are increasingly saturated with power electronic converters. Due to very high popularity of photovoltaic (PV) installations and the spread of electric vehicles (EV) as well as their charging installations, DC–AC and AC–DC converters are often found in power systems. The transformerless coupling of AC and DC systems via power electronic converters means that an electrical installation containing...
-
Drift, wow and flutter measurement and reduction in shrunken movie soundtracks
PublikacjaReferat przedstawia metodę i algorytmy do oceny i redukcji dryfu, kołysania i drżenia w skurczonych taśmach filmowych. Przedstawione algorytmy działają w oparciu o przetwarzaniu obrazu taśmy filmowej w celu wyznaczenia jej lokalnego skurczu, który jest jednym z powodów powstawania dryfu, kołysania i drżenia. Lokalny skurcz taśmy można wyznaczyć dzięki analizie wysokości: ramki obrazu, perforacji, lub innego, standaryzowanego elementu...
-
Fatigue life improvement using low transformation temperature weld material with measurement of residual stress
PublikacjaWelding processes often produce high levels of tensile residual stress. Low transformation temperature (LTT) welding wires utilise phase transformation strains to overcome the thermal contraction of a cooling weld. In this paper, the residual stress within each weld was quantified using the milling/strain gauge method, being the strain change measured as the weldment was milled away. The fatigue tests were conducted under uniaxial...
-
Experimental verification of a new method of loop resistance testing in low voltage systems with residual current devices
PublikacjaA periodical verification of the effectiveness of protection against electric shock shall be performed in low voltage systems. The scope of this verification includes loop impedance/resistance testing. If a residual current device is installed in a tested circuit, this testing is problematic. A residual current device trips out during the test, because of the high value of measurement current. This precludes the execution of the...
-
A new method of fault loop resistance measurement in low voltage systems with residual current devices
PublikacjaThis paper presents a new method of fault loop resistance measurement in low voltage systems with residual current devices. The method enables measuring fault loop resistance without nuisance tripping of residual current devices, by application an unconventional waveform of measurement current. It is important for proper verification of the effectiveness of protection against electric shock.
-
The Dominant Influence of Plastic Deformation Induced Residual Stress on the Barkhausen Effect Signal in Martensitic Steels
PublikacjaThe paper presents the results of investigation of the influence of plastic deformation on the magnetic properties of martensitic steel (P91 grade). The properties of the hysteresis loops as well as of the Barkhausen effect (BE) signal are analysed for both tensile and compressive loading up to ε = 10% of plastic deformation. The choice of the steel and of the deformation range is unique, since for such combination one can expect...