Wyniki wyszukiwania dla: ANALYTICAL METHOD
-
A device for measuring heat flux on a rocket skin surface
PublikacjaA novel method for measuring heat flux on a surface is presented. It is an extensive upgrade of currently known heat flux sensors used mostly in civil engineering. As the thermal environment of launchers, especially sounding rocket can have an enormous negative effect on payload, careful considerations have to be taken in the process of preparing insulation. Usually, thermal data provided by the launch vehicle manufacturer is limited...
-
Reaktory elektrochemiczne w przemyśle - konstrukcja i zastosowania
PublikacjaZ biegiem lat reakcje elektrochemiczne przestały być postrzegane jedynie jako eksperymenty laboratoryjne lub proste baterie. Chociaż mechanizm reakcji i budowa prostych reaktorów znana jest ludzkości już od ponad 100 lat w ostatnich latach można zauważyć największy wzrost zainteresowania tą dziedziną. Nowy stale opracowywane są lepsze projekty budowy reaktorów. Modyfikacje to nie tylko rodzaje i formy materiałów, z których wykonane...
-
Elective Project I _ Shelter_learning by doing
Kursy OnlineElective Project I _ Shelter - learning by doing “Your creativity and skills play an important role in making an impact in responding to humanitarian challenges and global crises” The world seems to be reeling from one crisis to another. Recently we experienced climate crises, global pandemic (Covid-19), economic uncertainty, wars, floods, wildfire, and earthquakes. Proceeding from the challenges facing humanity at the global...
-
Ekspertyza dotycząca bezzasadności zarzutów odnośnie parametrów metrologicznych analizatorów pyłu PM2,5 postawionych firmom EAS Envimet Polska Sp. z o.o. i EAS Envimet Analytical Systems GmbH przez spółkę MLU Sp. z o.o. z siedzibą w Katowicach w postępowaniu odwoławczym o sygn. akt: KIO/UZP 435/09
PublikacjaW ekspertyzie sporządzonej dla EAS Envimet Polska sp. z o.o. z siedzibą w Wieliczce wykazano bezzasadność zarzutów zgłoszonych przez Spółkę MLU w Katowicach w odniesieniu do urządzenia BAM1020 w postępowaniu odwoławczym toczącym się przed Prezesem Urzędu Zamówień Publicznych w związku z zaskarżeniem rozstrzygnięcia przetargu o zamówienie publiczne nr DM/5211-06-02/09/ABA na zakup automatycznego miernika pyłu zawieszonego PM2,5...
-
Analytical data on molecular umbrella: cispentacin and molecular umbrella: fluorescent probe conjugates
Dane BadawczeAnalytical data (NMR, MS, FTIR) for nine conjugates of molecular umbrella with cispentacin, Lys(Mca) or Nap-NH2. The conjugates have been rationally designed as potential antifungal agents. 1H NMR and 13C NMR spectra were obtained at 500 MHz Varian Unity Plus spectrometer and the deuterated solvents were used as internal locks. High-resolution mass...
-
Direct solid phase microextraction combined with gas chromatography – Mass spectrometry for the determination of biogenic amines in wine
PublikacjaA direct method based on immersion solid phase microextraction (DI-SPME) gas chromatography mass-spectrometry (GC-MS) was optimized and validated for the determination of 16 biogenic amines in Polish wines. In the analysis two internal standards were used: 1,7-diaminoheptane and bis-3-aminopropylamine. The method allows for simultaneous extraction and derivatization, providing a simple and fast mode of extraction and enrichment....
-
Improvement of derivatized amino acid detection sensitivity in micellar electrokinetic capillary chromatography by means of acid-induced pH-mediated stacking technique
PublikacjaDerivatization is a frequently used sample prepara-tion procedure applicable to the enhancement of analyte de-tection sensitivity. Amino acids mostly require derivatization prior to electrophoretic or chromatographic analysis, especial-ly if spectrophotometric detection is used. This study presents an on-line preconcentration technique for derivatized amino acids. The sensitivity of the method was improved by the utilization of...
-
Opinions and view of entrepreneurs regerding the single european Market-Analytical Model. W: Entrepreneurship and small business development in the21st century. Przedsiębiorczość i rozwój małych i średnich przedsiebiorstww XI wieku. Ed. B. Piasecki. Łódź: Uniw. Łódź**2002 s. 109-117.**2002 s. 109 - 117 Opinie i poglądy przedsiębiorców na temat Jednolitego Rynku Europejskiego - model analityczny.
PublikacjaArtykuł zawiera propozycje modelu czynników kształtujących świadomość pol-skich przedsiębiorców odnośnie szans i zagrożeń w związku z otwarciem gospodarki Polski na Jednolitu Rynek Europejski. Model ten musi być wykorzystany przy projektowaniu badań opinii i poglądów przedsiębiorców.
-
Plant-based meat substitute analysis using microextraction with deep eutectic solvent followed by LC-MS/MS to determine acrylamide, 5-hydroxymethylfurfural and furaneol
PublikacjaFor the analysis of plant-based meat substitutes and the determination of Maillard reaction products such as acrylamide, 5-hydroxymethylfurfural and furaneol, a novel and effective procedure based on hydrophobic natural deep eutectic solvent and liquid chromatography coupled with tandem mass spectrometry was developed for the first time. The 49 compositions of the deep eutectic solvents were designed and screened to select the...
-
Solid-Contact Ion-Selective Electrodes with Highly SelectiveThioamide Derivatives of p-tert-Butylcalix[4]arene for theDetermination of Lead(II) in Environmental Samples
PublikacjaThioamide derivatives of p-tert-butylcalix[4]arene were used as ionophores in the development of solid-contact ion-selective electrodes based on conducting polymer poly(3,4-ethylenedioxythiophene)/polystyrene sulfonate (PEDOT/PSS) which was synthesized by electrodeposition on the glassy carbon electrodes. The typical ion-selective membranes with optionally two different plasticizers [bis(2-ethylhexyl)sebacate (DOS) and 2-nitrophenyl...
-
Troubleshooting of the determination of bisphenol A at ultra-trace levels by liquid chromatography and tandem mass spectrometry
PublikacjaDetermination of trace amounts of bisphenol A (BPA) may cause problems mainly related to the presence of BPA in solvents (even in LC-MS grade), laboratory vessels, and plastic equipment used for sample preparation. Variable and sometimes significant amounts of BPA present in the background cause problems in obtaining good repeatability of measurements at the ultra-trace levels. Such observations (i.e., poor repeatability of results)...
-
Measurement of benzene concentration in urban air using passive sampling
PublikacjaAbstract The concentration of benzene in urban air in theTri-City area of Poland (Gdańsk-Sopot-Gdynia, andTczew) was assessed using diffusive passive samplers (Rad-iello). Samples were collected during a four-year monitoringcampaign (2007-2010) at selected monitoring stations man-aged by the Agency of Regional Air Quality Monitoring inthe Gdańsk Metropolitan Area (ARMAAG) Foundation.The performance of the passive samplers was investigatedin...
-
Efficiency and proportions of waste tyre pyrolysis products depending on the reactor type—A review
PublikacjaThis article discusses the current use of different pyrolytic reactors, their constructions and operating principles regarding the yields of main products of waste tyre pyrolytic recycling. Whether one makes a larger or smaller profit, or even a loss due to a surcharge being levied on waste tyre recycling, depends on the sale of the pyrolysis products (gas, char, oil), the proportions and market prices of which differ. The cheapest...
-
Suspended matter, composition and fluxes, Gdansk Deep, late spring 2001
Dane BadawczeParticulate organic carbon (POC) and nitrogen (PON) concentrations and fluxes were measured in the Gdańsk Deep (Gulf of Gdansk) from 30.05 to 06.06.2001. The vertical profiles of POC and PON were characterised by the highest values in the euphotic layer, a gradual decrease with depth, and an increase below the halocline. The hydrophysical conditions...
-
TEM imaging of Ag-Au nanoalloys
Dane BadawczeThe nanostructures of AuAg nanoalloys were prepared by sequential sputtering of metal thin layers (Au/Ag or Ag/Au) followed by annealing under 550 Celsius degree in an argon atmosphere. The basic single layer thickness was usually ca. 3 nm. For investigations two samples wih 50% Au and 50% Ag were selected and samples 1/3 Ag - 2/3 Au and 2/3 Ag - 1/3...
-
A nontargeted approach to determine the authenticity of Ginkgo biloba L. plant materials and dried leaf extracts by liquid chromatography-high-resolution mass spectrometry (LC-HRMS) and chemometrics
PublikacjaThe lack of stringent regulations regarding raw materials for herbal supplements used for medicinal purposes has been a constant challenge in the industry. Ginkgo biloba L. leaf extracts attract consumers because of the supposed positive effect on mental performance and memory. Supplements are produced using dried leaf materials and standardized leaf extracts such as EGb 761. Adulteration of Ginkgo biloba L. plants and extracts...
-
Application of normal-phase high-performance liquid chromatography followed by gas chromatography for analytics of diesel fuel additives
PublikacjaThe paper presents the results of investigations on new procedures of determination of selected cleaning additives in diesel fuel. Two procedures: one-step analysis using gas chromatography with flame ionization detection (GC-FID) or mass spectrometry (GC-MS) and a two-step procedure in which normal-phase high-performance liquid chromatography (NP-HPLC) was used for preliminary separation of the additives, were compared. The additive...
-
Research on the separation properties of empty-column gas chromatography (EC-GC) and conditions for simulated distillation (SIMDIS)
PublikacjaThe paper presents the results of investigations on new procedures of determination of selected cleaning additives in diesel fuel. Two procedures: one-step analysis using gas chromatography with flame ionization detection (GC-FID) or mass spectrometry (GC-MS) and a two-step procedure in which normal-phase high-performance liquid chromatography (NP-HPLC) was used for preliminary separation of the additives, were compared. The additive...
-
Comparability of Raman Spectroscopic Configurations: A Large Scale Cross-Laboratory Study
PublikacjaThe variable configuration of Raman spectroscopic platforms is one of the major obstacles in establishing Raman spectroscopy as a valuable physicochemical method within real-world scenarios such as clinical diagnostics. For such real world applications like diagnostic classification, the models should ideally be usable to predict data from different setups. Whether it is done by training a rugged model with data from many setups...
-
Sample preparation procedure for the determination of polycyclic aromatic hydrocarbons in petroleum vacuum residue and bitumen
PublikacjaThis paper describes a novel method of samplepreparation for the determination of trace concentrations ofpolycyclic aromatic hydrocarbons (PAHs) in high-boilingpetroleum products. Limits of quantitation of the investigatedPAHs in materials of this type range from tens ofnanograms per kilogram to <20 μg/kg. The studies revealedthat in order to separate most of interferences from theanalytes without a significant loss of PAHs, it...
-
Application of ion chromatography with pulsed amperometric detection for the determination of trace cyanide in biological samples, including breast milk
PublikacjaCyanide (CN) is the biomarker of exposure to the components of tobacco smoke, although its presence in biological samples is also due to the consumption of products containing cyanogenic glycosides. In this work, we determine the concentration of the free cyanide in urine, saliva and breast milk matrices, using ion chromatography with pulsed amperometric detection (IC-PAD). IC-PAD is an emerging method, with only few documented...
-
The topography of as-quenched and heat treated 58(2Bi2O3-V2O5)-42SrB4O7 glasses measured with confocal microscope
Dane BadawczeThe topography of as-quenched and heat treated 58(2Bi2O3-V2O5)-42SrB4O7 glasses measured with confocal microscope.
-
The morphology of as-quenched and heat treated 58(2Bi2O3-V2O5)-42SrB4O7 glasses measured with AFM
Dane BadawczeThe morphology of as-quenched and heat treated 58(2Bi2O3-V2O5)-42SrB4O7 glasses was measured with the use of atomic force microscope.
-
Determination of bromhexine and its metabolites in equine serum samples by liquid chromatography – Tandem mass spectrometry: Applicability to the elimination study after single oral dose
PublikacjaBromhexine (BH), expectorant used in the treatment of respiratory disorders associated with viscid or excessive mucus, is not permitted for use in the competing horse by many authorities in horseracing and Olympic disciplines. Metabolic studies are of the great importance in anti-doping field because they allow for updating the selection of the most appropriate markers for prohibited substances, such as metabolites present at higher...
-
Fatal N-Ethylhexedrone Intoxication
PublikacjaN-Ethylhexedrone [2-(ethyloamino)-1-phenylhexan-1-one; α-ethylaminohexanophenone; NEH] is one of the most recent synthetic cathinones that appeared on the illegal market in late 2015. The majority of information concerning the model of consumption of NEH and its impact on the body originates only from self-reports from grey literature websites and drug forums. There are only limited data associated with the concentrations of NEH...
-
The surface of the sensor used in the analysis of odorous substances
Dane BadawczeHuman industrial activity usually leads to smaller or larger interference with the ecosystem, contributing to changes affecting the quality of life. An example may be the emission of gaseous substances, not necessarily toxic, but due to their intense smell, they can cause discomfort to people exposed to their inhalation. The problem is so important...
-
Organochlorine pesticides and polichlorinated biphenyls concentrations in fresh snowfall or top layer of snow from Hornsund region, Svalbard, in the spring 2019
Dane BadawczeThe dataset contains concentration of organochlorine persistent organic pollutants in snow samples collected from top layer of snow, which corresponded to fresh snowfall in most cases (except DS location, where these are 20 cm top layer sampled weekly). All snow samples have been collected within one month during spring 2019, in the vicinity of the...
-
Boron-doped carbon nanowalls for fast and direct detection of cytochrome C and ricin by matrix-free laser desorption/ionization mass spectrometry
PublikacjaDetecting proteins via surface assisted laser desorption/ionization mass spectrometry (SALDI-MS) method is still highly challenging, and only few examples of nanomaterials have been demonstrated to perform such detection so far. In this study, carbon nanowalls (CNWs), vertically aligned graphene sheet-based materials, presenting specific morphology, dimensions, and boron doping levels have shown improved performances for both qualitative...
-
Thermal properties of ceramic Bi2VO5.5 and strontium–borate glass-ceramics containing crystalites of Bi2VO5.5. measured with DSC
Dane BadawczeThermal properties of ceramic Bi2VO5.5 and strontium–borate glass-ceramics containing Bi2VO5.5 crystallites was measured by DSC.
-
Agata Kot-Wasik prof. dr hab. inż.
OsobyAgata Kot-Wasik, urodzona w 1964 r. w Siedlcach (woj. mazowieckie), ukończyła studia magisterskie w 1988 r. na Wydziale Chemicznym Politechniki Gdańskiej, w specjalności Analityka Techniczna i Przemysłowa. W latach 1988–1992 była zatrudniona w Katedrze Chemii Organicznej na macierzystym wydziale na stanowisku naukowo-technicznym. W 1990 r. ukończyła na PG studia podyplomowe „Techniki Instrumentalne w Analizie Śladów i Ochronie...
-
Ocean mixed layer dynamics: high-resolution simulations of wind, wave and convective effects
Dane BadawczeThis dataset contains results of high-resolution numerical simulations of the ocean mixed layer (OML) forced by wind, waves and cooling from the atmosphere, i.e., under strongly turbulent, convective conditions. The goal is to provide detailed, three-dimensional information about OML circulation, turbulent kinetic energy, and temperature and salinity...
-
Measurements of raising of 160EC pantograph type
Dane BadawczeIn this description the results of the experiment and also simulation performed on the total assembly of the 160 EC pantograph type is given. Multibody dynamics of pantograph rising due to external torque and forces are measured for parameter validation of the pantograph model.
-
Estimation of the uncertainty of the AC/AC transducer output voltage
PublikacjaThe paper presents a methodology for estimating uncertainty of voltage transducers processing function, on the example of CYVS411D07 voltage transducers. The analysis was conducted using the method based on the GUM Guide propagation of uncertainty law and the determination of the coverage factor based on the effective number of degrees of freedom (t-Student distribution). The paper also presents example evaluation results of measured...