Wyniki wyszukiwania dla: HIGH-VOLTAGE - MOST Wiedzy

Wyszukiwarka

Wyniki wyszukiwania dla: HIGH-VOLTAGE

Wyniki wyszukiwania dla: HIGH-VOLTAGE

  • Reducing common mode voltage and bearing currents in quasi - resonant DC - link inverter

    In the paper, a concept of separation of an inverter-fed induction motor drive from its mains supply by two transistor switches inserted in the dc-link circuit is reexamined based on the proposed parallel quasi-resonant dc-link inverter (PQRDCLI). The objective of the paper is to show an advantage of the proposed topology in limiting high frequency common mode voltage and bearing currents. In the laboratory setup, an induction...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Design of Intelligent Low-Voltage Load Switch for Remote Control System in Smart Grid

    Publikacja

    Current low-voltage load switches do not support remote disconnect/connect and real-time monitoring of a disconnect/connect state. Addressing to these issues, this paper presents a low-voltage load switch for a smart remote control system, which uses a one-chip microcontroller board and a DC step motor drive mechanism and provides the feedback on the switch status also. Arrears disconnect and full-pay connect control is implemented...

    Pełny tekst do pobrania w portalu

  • Frequency measurement research with weight averaging of pulse output signal of voltage-to-frequency converter

    Publikacja

    - MEASUREMENT - Rok 2023

    The paper presents the essence and investigation of the efficiency of weight averaging of a pulse output signal of voltage-to-frequency converter. The effect of counting and the influence of interference on the result of weight averaging of frequency modulated pulses are analyzed. It is shown that from the point of view of counting error reduction, the best are polynomial weight functions. In the case of high interferences whose...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Experimental verification of a new method of loop resistance testing in low voltage systems with residual current devices

    Publikacja

    - Rok 2016

    A periodical verification of the effectiveness of protection against electric shock shall be performed in low voltage systems. The scope of this verification includes loop impedance/resistance testing. If a residual current device is installed in a tested circuit, this testing is problematic. A residual current device trips out during the test, because of the high value of measurement current. This precludes the execution of the...

  • Electrical safety in low-voltage DC microgrids with B-type residual current devices

    Publikacja

    Residual current devices (RCDs) are most popular devices used in low-voltage installations for protection against electric shock and fire. In cases of high risk of electric shock the application of RCDs is mandatory. Currently, the spread of local direct current (DC) microgrids is widely considered. This creates new challenges for protective systems, in particular those based on RCDs. The main purpose of the research is to test...

    Pełny tekst do pobrania w portalu

  • Voltage Conditions in Low Voltage Grid with Connected Mictogeneration

    Publikacja

    The introduction of distributed generation into a low voltage grid may cause voltage problems in it. The paper discusses the effect of microgeneration on voltage levels in a low voltage grid. A real low voltage grid of considerable length was selected for the analysis. The grid primarily supplies residential buildings in a rural area. Results of tests that consider potential measures which could be applied in this grid to improve...

    Pełny tekst do pobrania w portalu

  • Problems with microprocessor voltage-to-frequency and frequency-to-voltage converters implementation

    The article presents the problems of digital voltage-to-frequency and frequency-to-voltage processing. Transducer systems implemented in microprocessor technology are presented, the timing of signals and functioning algorithms are discussed. An analysis of processing errors has been performed and the results of experimental studies of realized systems are presented.

    Pełny tekst do pobrania w portalu

  • Voltage Harmonics Measuring Issues in Medium Voltage Systems

    Publikacja

    - Rok 2011

    W rozdziale przedstawiono zagadnienia związane z dokładnością pomiarów zniekształceń harmonicznych napięcia z wykorzystaniem przekładników napięciowych w sieciach średnich napięć.

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Adaptive Algorithm of a Tap-Changer Controller of the Power Transformer Supplying the Radial Network Reducing the Risk of Voltage Collapse

    Publikacja

    - ENERGIES - Rok 2020

    he development of renewable energy, including wind farms, photovoltaic farms as well as prosumer installations, and the development of electromobility pose new challenges for network operators. The results of these changes are, among others, the change of network load profiles and load flows determining greater volatility of voltages. Most of the proposed solutions do not assume a change of the transformer regulator algorithm....

    Pełny tekst do pobrania w portalu

  • Failure analysis of a high-speed induction machine driven by a SiC-inverter and operating on a common shaft with a high-speed generator

    Publikacja

    - Eksploatacja i Niezawodność - Maintenance and Reliability - Rok 2022

    Due to ongoing research work, a prototype test rig for testing high-speed motors/generators has been developed. Its design is quite unique as the two high- speed machines share a single shaft with no support bearings between them. A very high maximum operating speed, up to 80,000 rpm, was required. Because of the need to minimise vibration during operation at very high rotational speeds, rolling bearings were used. To eliminate...

    Pełny tekst do pobrania w portalu

  • Improving voltage levels in low-voltage networks with distributed generation – case study

    Publikacja

    - Rok 2018

    The use of distributed generation in low-voltage networks may cause the voltage variation in them, within the wide range. In unfavourable circumstances, the voltage may reach unacceptable values. The paper presents the effect of distributed generation on voltage levels in a selected low-voltage rural distribution network in Poland. An analysis of possible methods for improving voltage levels in this network is conducted. The most...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Increasing the Utilization of dc-link Voltage of a Five-Leg VSI Based on Rotor Angle Control of Dual Induction Motors

    Publikacja

    This paper introduces an increased utilization of the dc-link voltage of a five-leg voltage source inverter (VSI) based on the rotor flux angle control technique for dual induction motors, IM. The main purpose is to utilize additional abilities provided by a multi-motor drive system in limited operating conditions. Generally, a multi-motor drive system is widely used in electric vehicles (EVs), traction systems and in several industrial...

    Pełny tekst do pobrania w portalu

  • Method of earth fault loop impedance measurement without nuisance tripping of RCDs in 3-phase low-voltage circuits

    Verification of electrical safety in low-voltage power systems includes the measurement of earth fault loop impedance. This measurement is performed to verify the effectiveness of protection against indirect contact. The widespread classic methods and meters use a relatively high value of the measuring current (5–20) A, so that they are a source of nuisance tripping of residual current devices (RCDs). The meters dedicated to circuits...

    Pełny tekst do pobrania w portalu

  • Experimental test results of an automatic voltage regulator with independent phase voltage controllers

    The growing number of distributed renewable energy sources and dynamic constant-power loads (e.g. electric vehicle charging stations) pose new challenges for network operators. These changes result in alterations to network load profiles and load flows, leading to greater voltage volatility. One effective solution to these problems can be the use of automatic voltage regulators (AVRs), which stabilize and symmetrize voltage output,...

    Pełny tekst do pobrania w portalu

  • Voltage variations and their reduction in a rural low-voltage network with PV sources of energy

    Publikacja

    - Electronics - Rok 2021

    Renewable sources of energy (RES), especially photovoltaic (PV) micro-sources, are very popular in many countries. This way of clean power production is applied on a wide scale in Poland as well. The Polish legal regulations and tariffs specify that every prosumer in a low-voltage network may feed this network with a power not higher than the maximum declared consumed power. In power networks with RES, the voltage level changes...

    Pełny tekst do pobrania w portalu

  • Quasi-resonant DC-link voltage inverter with enhanced zero-voltage switching control

    A new topology modification of the parallel quasi-resonant circuit for a dc-link voltage inverter enables regulation of the zero voltage dc-link subperiods and the dc-link voltage gradient settings. The proposed circuit is based on four MOSFET switches with free-wheeling diodes for controlled quasi-resonant recharging between L-C tank in order to assure inverter zero voltage switching (ZVS) conditions. Design optimization of the...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Exact generation of voltage vector in voltage inverter with pulse width modulation

    W artykule zaproponowano metodę modulacji szerokości impulsów dla falownika napięcia. Proponowana metoda rozwiązuje problemy związane z kompensacją czasów martwych oraz kompensacją wpływu parametrów łączników energolelektronicznych na napięcie wjściowe falownika. W artykule zaprezentowano metodę kompensacji między innymi pojemności pasożytniczych tranzystorów, dyskretyzacji czasów załączeń tranzystorów. Przedstawiona metoda modulacji...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Voltage profiles improvement in a power network with PV energy sources – results of a voltage regulator implementation

    Publikacja
    • A. Szultka
    • S. Szultka
    • S. Czapp
    • R. Karolak
    • M. Andrzejewski
    • J. Kapitaniak
    • M. Kulling
    • J. Bonk

    - ENERGIES - Rok 2022

    The constant increase in the number of photovoltaic (PV) energy sources in distribution networks is the cause of serious voltage problems. The networks built at least a dozen years ago are not provided for the installation of a large number of micro-sources. It happens that the previously properly functioning power networks are not able to provide to consumers power with the required parameters, after installing many PV sources....

    Pełny tekst do pobrania w portalu

  • High Performance Control of AC Drives with Matlab/ Simulink

    Publikacja

    - Rok 2021

    Explore this indispensable update to a popular graduate text on electric drive techniques and the latest converters used in industry. The Second Edition of High Performance Control of AC Drives with Matlab®/Simulink delivers an updated and thorough overview of topics central to the understanding of AC motor drive systems. The book includes new material on medium voltage drives, covering state-of-the-art technologies and challenges...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Medium voltage drives - challenges and requirements

    Publikacja

    - Rok 2010

    The design and application of medium voltage (MV) drives are associated with different requirements related to the line side and motor side of the drive. This paper presents a brief review of the existing challenges and requirements for employing medium voltage drives in various industries. Line side, motor side, and converterproblems and requirements are described. The aim of the paper is to review the existing problems to allow...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Supercapacitors - charge redistribution and restoring voltage

    Publikacja

    - Rok 2014

    The charge in supercapacitor is stored on electrodes and in electrolyte. The charges on electrodes create the Helmholtz double layer which is formed immediately with time constant of the order of seconds, while the charge storage in electrolyte is going on with time constant of the order of hundreds seconds. When the charged supercapacitor is shorted for few seconds, the charge from electrodes is discharged while the charge in...

  • Marek Adamowicz dr hab. inż.

    Stopień naukowy doktora uzyskał w 2008 r. na Wydziale Elektrotechniki i Automatyki Politechniki Gdańskiej. W latach 2005 – 2011 pracował na Akademii Morskiej w Gdyni. W 2010 r. jako laureat programu NCBR LIDER wybrał Wydział Elektrotechniki i Automatyki Politechniki Gdańskiej jako jednostkę realizującą swój projekt z zakresu szerokopasmowych przyrządów półprzewodnikowych i ich zastosowań w elektrowniach wiatrowych. Od 2011 roku...

  • Marek Olesz dr hab. inż.

    Wydział Elektrotechniki i Automatyki, Prodziekan ds. rozwoju dr hab. inż. Marek Olesz, prof. PG data urodzenia 1966 wykształcenie   Politechnika Gdańska, Wydział Elektryczny (1990) stopień / tytuł naukowy doktor habilitowany – Politechnika Gdańska, Wydział Elektrotechniki i Automatyki (2017), doktor – Politechnika Gdańska, Wydział Elektrotechniki i Automatyki (1998) zatrudnienie Politechnika Gdańska: asystent stażysta (1989 –...

  • Static Shunt PE Voltage-Quality Controllers

    Publikacja

    - Rok 2007

    This chapter focuses on power electronics (PE)-based solutions used in distribution networks for reduction of supply-voltage-quality deterioration, from long interruptions to the harmonics. Various PE devices and their combinations are addressed for particular or a range of voltage disturbances. A particular solution is applied taking into account demands for voltage quality and network configuration. In general, there are three...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • CM Voltage Compensators for Power Electronic Interfaces

    Publikacja
    • R. Smoleński
    • J. Bojarski
    • P. Leżyński
    • A. Kempski
    • J. Łuszcz

    - IEEE Electromagnetic Compatibility Magazine - Rok 2015

    The experimental results presented in the paper have shown that the application of the PEIs might cause EMC related problems, especially in the case of the application of a group of connected converters. The most convenient way to reduce EMI currents and prevent aggregation of EMI currents introduced by a group of converters is through passive compensation of voltage interference sources inside of the single converters. In the...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Multipulse inverter structures with low voltage distortion

    Publikacja

    - Rok 2016

    A novel approach to the voltage source inverters (VSI) construction is presented in the paper. The invented inverter structures allow to operate several DC/AC converters in parallel resulting in lower voltage distortions at extremely low switching frequency. The research presented in the paper describes such a parallel operation of the VSI’s which is possible thanks to the use of coupled inductors. The eighteen-pulse three-level...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Control strategies and comparison of the Dynamic Voltage Restorer

    Publikacja

    - Rok 2008

    This paper focuses on a selection problems of mitigation of the voltage disturbance by of the Dynamic Voltage Restorers (DVR’s). In short form presented and discussed are the basis of different control strategies of the DVR. The main emphasis is placed on application of modern power electronic devices. Authors of this paper in particular occupy oneself with analysis of the power rating of the typically DVR topologies. These problems...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • AC Motor Voltage and Audible Noise Dataset

    Publikacja

    - Rok 2022

    The dataset titled AC motor voltage and audible noise waveforms in ship’s electrical drive systems with frequency converters contains the voltage and sound measurement results recorded in a marine frequency controlled AC drive system. The dataset is part of research focussing on the impact of the ship’s electrical drive systems with frequency converters on vibrations and the level of audible noise on ships. The dataset allows the...

    Pełny tekst do pobrania w portalu

  • The influence of SVC on the progress of voltage collapse

    Publikacja

    The article presents the simulation concerning the cooperation of SVC circuit with a generative set in time, when of power system reaches low values which may lead to the fall-out of generator from the synchronous operation.

  • Low voltage photovoltaic power system

    The use of photovoltaics is growing rapidly in the industry as well as households. Therefore, educating the public will help them understand solar cell technology, which is becoming more common in everyday life. This paper proposes a demonstrational set-up of photovoltaic panel for the purpose of science education. It was used in numerous outreach activities such as science fairs. Moreover, it proved to be a great tool for education...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Modern Arrangement for Reduction of Voltage Perturbations

    Publikacja

    - Rok 2007

    The contents of this chapter encompass general problems and the most important issues of power-supply-quality improvement in AC systems. In the context of the above, consideration is given to evaluation of bilateral interactions of receivers with an electrical power-distribution system and methods of their reduction. Also are discussed the basis of operation of the most important compensation-filtration devices and their applications...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Quality assessment of low voltage surge arresters

    Users expect reliable operation of the surge arrester during overvoltages, which may originate from a switching process or a lightning discharge. The necessary conditions to guarantee these expectations are: appropriate construction of the surge arrester, its production being maintained in accordance with technical standards, and a positive results of the type test (as well routine and acceptance tests). The recipient, especially...

    Pełny tekst do pobrania w portalu

  • Estimation of the uncertainty of the AC/AC transducer output voltage

    The paper presents a methodology for estimating uncertainty of voltage transducers processing function, on the example of CYVS411D07 voltage transducers. The analysis was conducted using the method based on the GUM Guide propagation of uncertainty law and the determination of the coverage factor based on the effective number of degrees of freedom (t-Student distribution). The paper also presents example evaluation results of measured...

    Pełny tekst do pobrania w portalu

  • The Impact of Micro-Sources on Voltage Distortions in a Power Grid

    Publikacja

    The increase in the number of photovoltaic (PV) systems integrated with low voltage (LV) grids has led to a great need to analyse the impact of these systems on the quality of electricity and the reliability of its supply. This paper presents and compares the energy quality requirements imposed by various countries on photovoltaic plants. Then, based on real object tests and simulation in DIgSILENT PowerFactory, the impact has...

    Pełny tekst do pobrania w portalu

  • Voltage control in a power system with renewable sources of energy

    Publikacja

    - Rok 2019

    Intensive development of distributed generation in power systems, caused by the European Union energy policy, gives possibility for improving safety in power delivery as well as optimizing the costs of the systems functioning. In this context, distributed generation can be used for voltage control in power systems – it can be performed by the control of reactive power of each source of energy or a group of energy sources. This...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Fractional-order Systems and Synchronous Generator Voltage Regulator

    Publikacja

    - Acta Energetica - Rok 2015

    Modern regulators of synchronous generators, including voltage regulators, are digital systems, in their vast majority with standard structures contained in the IEEE standard. These are systems described with stationary differential equations of integral order. Differential equations of fractional order are not employed in regulators for synchronous generator control. This paper presents an analysis of the possibilities of using...

    Pełny tekst do pobrania w portalu

  • An improved adaptive neural voltage controller for turbogenerator

    Publikacja

    - Rok 2007

    Opracowano model adaptacyjnego neuronowego regulatora napięcia z nastrojonym współczynnikiem wzmocnienia funkcji przynależności i z nastrojonym współczynnikiem uczenia sieci neuronowej w zależnosci od stanu obciążenia turbogeneratora. Przedstawiono wyniki symulacji mające na celu badania efektywności proponowanego regulatora. Te wyniki porównano z wynikami uzyskanymi z regulatorem o stałym współczynnikiem wzmocnienia funkcji przynależności...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Laboratory tests of medium voltage switchgear isolators

    Publikacja
    • W. Chmielak
    • T. Daszczynski
    • Z. Pochanke
    • M. Wesolowski
    • R. Szreder
    • N. Obarski

    - Rok 2017

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Increase of Diagnostic Capabilities of Voltage Fluctuation Indicies

    Publikacja

    - Rok 2020

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Problems of exact generation ofinverter output voltage

    Publikacja

    W pracy przedstawiono nową modyfikację modulatora szerokości impulsów. Rozważono problemy generacji dokładnej wartości napięcia wyjściowego falownika. Zaproponowano dwie metody generacji małej wartości napięcia.

  • Predictive Current Control of Voltage-Source Inverter.

    Publikacja

    - Rok 2004

    W artykule przedstawiono regulator prądu stojana silnika asynchronicznego z predykcją napiecia wyjściowego. Rozważono aspekty praktycznej realizacji algorytmu w układzie z procesorem sygnałowym związane z opóźnieniami pomiaru prądu przy zastosowaniu przetwornika A/C. Układ zrealizowano praktycznie przy wykorzystaniu układu FPGA. W pracy zamieszczono wyniki badań symulacyjnychi eksperymentalnych.

  • High Efficiency Dual-Active-Bridge Converter with Triple-Phase-Shift Control for Battery Charger of Electric Vehicles

    Publikacja
    • S. Kuo
    • H. Chiu
    • C. Chiang
    • T. Huang
    • Y. Chang
    • S. Bachman
    • S. Piasecki
    • M. Jasiński
    • M. Turzyński

    - ENERGIES - Rok 2024

    An optimal modulation scheme with triple-phase-shift (TPS) control could increase the efficiency in the entire load range for a dual-active-bridge (DAB) converter under wide output voltage range conditions. Therefore, this study proposes a convergent approach to TPS mode selection, coupled with an optimal modulation scheme, ensuring the circuit’s efficiency over the entire range in the realm of a high-power and high-efficiency...

    Pełny tekst do pobrania w portalu

  • Static Series and Shunt-series PE Voltage-quality Controllers

    Publikacja

    - Rok 2007

    As presented in the Chap. 7 static shunt power electronics (PE) voltage-quality controllers protect the utility electrical system from the unfavorable impact of customer loads. Shunt controllers, as shown in Chap. 6, are recommended mainly for mitigation of the causes of disturbances, and not their effects in distanced nodes of a power-electronics system. In the case when reduction of disturbances effects is required, which leads...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Improving sensitivity of residual current transformers to high frequency earth fault currents

    For protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when high frequency earth fault current occurs. Serious hazard of electrocution exists then. In order to detect such a current, it is necessary to modify parameters of residual current devices, especially the operating point of their current transformer. The authors proposed...

    Pełny tekst do pobrania w portalu

  • DC-link voltage balancing in cascaded H-Bridge converters

    In the paper a DC-link voltage balancing strategy for multilevel Cascaded H-Bridge (CHB) converter is proposed. Presented solution bases on optimal choice of active vector durations in Space-Vector Pulse Width Modulation (SV-PWM). It makes it possible to DC-link voltages control and to properly generate the output voltage vector in the case of DC-link voltage unbalance. Results of simulation and experimental researches...

    Pełny tekst do pobrania w portalu

  • Low harmonic multipulse voltage converters using coupled reactors

    Publikacja

    - Rok 2016

    This paper presents a novel approach to the multi pulse voltage converters (VC), especially voltage source inverters (VSI) and matrix converters (MC) based on several typical identical modules connected in parallel using coupled reactors. Such arrangements resulting in lower voltage distortions at extremely low switching frequency. The proposed arrangement was validated by simulation. Laboratory models of 18- and 24pulse 3-level...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • THE INFLUENCE OF PHASE SHIFTERS ON THE VOLTAGE STABILITY OF CONNECTED POWER SYSTEMS

    Publikacja

    The paper presents the results of simulation tests of connected power systems in which phase shifters were installed on cross-border links. The analysis was carried out in terms of assessing the impact of shifters on node voltage stability. Individual systems were characterized by different balance of active power: deficit or excess. The evaluation of voltage stability was based on the dU/dQ and dU/dP criteria.

  • Selection of excitation signals for high-impedance spectroscopy

    A method of fast impedance spectroscopy of technical objects with high impedance (|Zx| > 1 GOhm) is evaluated in this paper. An object is excited with a signal generated by a digital-to-analog converter (DAC) located on the U2531A DAQ module. Response signals proportional to current flowing through and voltage across the measured object are sampled by analog-to-digital converters (ADC) in the DAQ module. The object impedance spectrum...

    Pełny tekst do pobrania w portalu

  • Modular multipulse voltage source inverters with integrating coupled reactors

    Publikacja

    - Rok 2016

    A novel approach to the voltage source inverters (VSI) construction is presented in the paper. The invented inverter structures allow to operate several DC/AC converters in parallel resulting in lower voltage distortions at extremely low switching frequency. The research presented in the paper describes such a parallel operation of the VSI’s which is possible thanks to the use of coupled inductors. The eighteen-pulse and twenty-four-pulse...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Use of AMI Meters in the Process of Low Voltage Grid Optimization

    Publikacja

    - Acta Energetica - Rok 2017

    This is a report of a project involving, inter alia, low voltage grid performance optimization with data from AMI meters . The study was supported with a European UPGRID grant, and executed by a consortium of companies from seven European countries, including Poland .

    Pełny tekst do pobrania w portalu