Filtry
wszystkich: 634
-
Katalog
- Publikacje 578 wyników po odfiltrowaniu
- Czasopisma 6 wyników po odfiltrowaniu
- Osoby 10 wyników po odfiltrowaniu
- Projekty 2 wyników po odfiltrowaniu
- Aparatura Badawcza 1 wyników po odfiltrowaniu
- Kursy Online 2 wyników po odfiltrowaniu
- Wydarzenia 1 wyników po odfiltrowaniu
- Dane Badawcze 34 wyników po odfiltrowaniu
Wyniki wyszukiwania dla: LITHIUM-ION BATTERIES
-
Practical Approach to Large-Scale Electronic Structure Calculations in Electrolyte Solutions via Continuum-Embedded Linear-Scaling Density Functional Theory
PublikacjaWe present the implementation of a hybrid continuum-atomistic model for including the effects of a surrounding electrolyte in large-scale density functional theory (DFT) calculations within the Order-N Electronic Total Energy Package (ONETEP) linear-scaling DFT code, which allows the simulation of large complex systems such as electrochemical interfaces. The model represents the electrolyte ions as a scalar field and the solvent...
-
Batteries-Basel
Czasopisma -
Batteries & Supercaps
Czasopisma -
Determination of Chemical Diffusion Coefficient of Lithium Ions in Ceramics Derived from Pyrolysed Poly(1,2-dimethylsilazane) and Starch
PublikacjaThe apparent chemical diffusion coefficient Li+ (DappLI+) in pyrolysed poly(1,2-dimethylsilazane)/starch (PSN/S) (weight ratio: 30/70) ceramic anode composite is determined by galvanostatic intermittent titration technique (GITT). The electrode material composition is C6.00N0.14H0.47O0.12Si0.13. The calculated values of DappLI+, depend on the applied potential, vary from 10-14 to 10-9 [cm2/s]. The diffusion coefficient of lithium...
-
Unidirectional DC/DC Converter with Voltage Inverter for Fast Charging of Electric Vehicle Batteries
PublikacjaThe paper proposes the adaptation of the industrial plant’s power network to supply electric vehicle (EV) fast-charging converters (above 300 kW) using renewable energy sources (RESs). A 600 V DC microgrid was used to supply energy from RESs for the needs of variable speed motor drives and charging of EV batteries. It has been shown that it is possible to support the supply of drive voltage frequency converters (VFCs) and charging...
-
Hybrid storage management system consisting of supercapacitors and AHI batteries
PublikacjaIn the article the hybrid storage, composed of Aqueous Hybrid Ion battery and supercapacitor was presented. The system was tested through simulation studies. The work also describes the construction and properties of the developed device meant to control the energy flow of the storage and a communication system for remote parameter supervision.
-
Optical rotation in the lithium triborate nonlinear crystal
PublikacjaA dual-wavelength polarimetric technique at 633 and 661 nm has been used for the characterization of a nonlinear lithium triborate (LiB3O5) nonenantiomorphous biaxial crystal. The mismatch of the crystallographic and optical coordinate systems was taken into account. The optical rotatory power for light propagation along one of the optical axes is ρ = 7.06° mm−1. The gyration tensor component along the bisector between the x and...
-
Dopants and gas modifiers in ion mobility spectrometry
PublikacjaThe ion mobility techniques, including the most commonly used drift-tube ion mobility spectrometry (IMS) and differential mobility spectrometry (DMS), are used successfully for the detection of a wide range of organic compounds in the gas phase. In order to improve detection quality, admixtures are added to gas streams flowing through the detector. Dopants mostly prevent the ionization of interfering chemicals however, better detection...
-
Determination of cyanide ion in urine samples using ion chromatography with pulsed amperometric detection.
PublikacjaCyanides are widely applied in industrial activity, including gold and silver mining and the production of organic chemicals. HCN is also formed directly from fossil fuel combustion sources from gasoline and diesel vehicles. In natural environment, in plants seeds for example an apple seed, it exists as a cyanogenic glycosides. The amount of cyanide ions originating from food products is however rather small. Larger concentrations...
-
Understanding ion–ion and ion–solvent interactions in aqueous solutions of morpholinium ionic liquids with N-acetyl-L-alaninate anion through partial molar properties and molecular dynamics simulations
PublikacjaAmino acid ionic liquids (AAILs) provide a low toxicity, biodegradable alternative to conventional ionic liquids, while also maintaining solubility in water. Densities and sound velocities of aqueous solutions of four amino acid ionic liquids (AAILs), based on the N-alkyl-N-methylmorpholinium ([Mor1,R], R = 2, 3, 6, 8) cation and N-acetyl-L-alaninate ([N-Ac-L-Ala]) anion were measured at T = (293.15–313.15) K and at atmospheric...
-
Differential expression profile between amygdala and blood during chronic lithium treatment in a rat model of depression – a pilot study
PublikacjaLithium is a mood stabilizer widely used in the pharmacotherapy of bipolar disorder and treatment‑resistant depression. Taking into account dysregulated inflammatory activity in depression and the immunomodulatory role of lithium, we hypothesized that genes associated with inflammatory responses may be potential biomarkers of lithium action. We aimed to compare gene expression changes between the brain and the periphery after...
-
Structural and optical investigations of sol-gel derived lithium titanate thin films
Publikacjain this paper structural and optical studies of lithium titanate (lto) thin films are presented. nanocrystalline thin films with 800 nm thickness were prepared by sol-gel method. to examine the influence of the annealing time on as-prepared films crystallization, the coatings were heated at 550 °c for 10, 20 and 80 h. structure of manufactured thin films was investigated using x-ray diffraction (xrd). the most visible lithium titanate...
-
Ion Chromatography in Environmental Analysis of Selected Organic Acids
PublikacjaLow molecular mass carboxylic acids (LCAs) occur in many environmental compartments dueto natural processes and human activity. When volatile and nonvolatile acids are to be monitored then liquidchromatography, including ion chromatography seems a method of choice. At high pH the acids are inionized form and can be separated as carboxylats by means of anion exchange chromatography. LCAs canalso be separated at low pH by ion exclusion...
-
Lead(II)-selective ionophores for ion-selective electrodes: A review
PublikacjaIn potentiometry, high selectivity of the ion-selective membranes must be assured in order to reliably measure various analytes in clinical, industrial and environmental samples. Due to the toxic nature of lead(II) it is important to monitor Pb2+ distribution in natural waters. This may be achieved by implementation of ion-selective electrodes (ISEs) with high selectivity towards lead(II) and low detection limit. A great number...
-
Determination of energy-transfer distributions in ionizing ion-molecule collisions
PublikacjaThe main objective of this study is to determine the energy transfer occuring in ion-molecule collisions. In order to solve this problem, we followed two approaches; the first one by validating a purely experimental method and the second one by testing a new theoretical model M3C (Microcanonical Metropolis Monte Carlo).
-
Functionalized azobenzocrown ethers as sensor materials—The synthesis and ion binding properties
PublikacjaNew 13- and 16-membered azobenzocrown ethers with aromatic amino, amide, ether–ester or ether–amide residue in para position to an azo moiety were obtained. Acid–base properties and ion binding ability of the colored compounds were studied by spectroscopic methods: UV–vis, fluorimetry and 1H NMR spectroscopy. Selected azobenzocrowns were tested as ionophores in ion-selective membrane electrodes (ISEs) – classic and miniature all...
-
Signature of Oxide-Ion Conduction in Alkaline-Earth-Metal-Doped Y3GaO6
PublikacjaWe have studied alkaline-earth-metal-doped Y3GaO6 as a new family of oxide-ion conductor. Solid solutions of Y3GaO6 and 2% −Ca2+-, −Sr2+-, and −Ba2+-doped Y3GaO6, i.e., Y(3−0.06)M0.06GaO6−δ (M = Ca2+, Sr2+, and Ba2+), were prepared via a conventional solid-state reaction route. X-ray Rietveld refined diffractograms of all the compositions showed the formation of an orthorhombic structure having the Cmc21 space group. Scanning electron...
-
Azomacrocyclic derivatives of imidazole: synthesis, structure, and metal ion complexation properties
PublikacjaNew azocrown ethers comprising imidazoles in the macrocycle have been synthesized. Imidazole, 2-methyl-, 4-methyl-, and 4-phenylimidazole were incorporated to form macrocyclic units by coupling with the appropriate bis-diazonium salts. The syntheseswere performed under high dilution conditions. The X-ray structure of a water adduct of the 21-membered crown ether derivative of 4-methylimidazole 8 has been solved. Metal...
-
Preparation and Characterization of Nanomaterial Consisting of Silica Aerogel & Carbon Tested as an Electrode in Non-Aqueous Media Containing Lithium Salt.
PublikacjaSilica aerogel (SiO2ag) was combined with carbonaceous material in the pyrolysis process of hydrocarbons. The obtained nanocomposite SiO2ag/C was amorphous, partially preserving the porous structure of SiO2ag. The specific surface area changes from 445.6 m2/g for pure SiO2ag to 205.52 m2/g SiO2ag/C. The 29Si MAS-NMR shows a three-dimensional matrix with silicon atoms connected to other silicon atoms by four...
-
Mobile Gas Chromatographs Coupled with Mass and Ion Mobility Spectrometers and their Applications
PublikacjaThe articles describes the developments un combining of mass and ion mobility spectrometers (MS, IMS0 with miniature gas chromatographs (GC). The examples of applications of miniaturised GC-MS and GC-IMS devices are presented.
-
Synthesis and application of tetrazole di and triamide derivatives in ion-selective membrane electrodes
PublikacjaA number of tetrazole diamides and triamides have been synthesized and applied as ion carries in ion-selective membrane electrodes. Their selectivity and sensitivity were studied towards alkali, alkaline earth, transition and heavy metal cations. it was found that membranes doped with 3 and 2-nitrophenyl octyl ether exhibit an almost theoretial Nernstian response for NH+ over relatively wide concentration range. Elestrodes with...
-
Charge dependence of fragmentation process induced by ion collisions with furan molecule
PublikacjaThe goal of this work is to describe the system evolution after ion-molecule interaction. We combine different quantum chemistry and statistical mechanics approaches in order to give extended description of the process. Herein we report on a recent study of the fragmentation mechanism of neutral, singly- and doubly-ionized furan molecule in the gas phase.
-
Potentiometric Solid-Contact Ion-Selective Electrode for Determination of Thiocyanate in Human Saliva
PublikacjaA new solid-contact potentiometric ion-selective electrode for the determination of SCN− (SCN-ISE) has been described. Synthesized phosphonium derivative of calix[4]arene was used as a charged ionophore. The research included selection of the ion-selective membrane composition, determination of the ISEs metrological parameters and SCN-ISE application for thiocyanate determination in human saliva. Preparation of the ISEs included...
-
The study of structure and surface morphology of lithium titanate sol-gel derived thin films
PublikacjaIn this paper the structure and the surface morphology of lithium titanate (LTO) thin films are presented. Nanocrystalline thin films were prepared by sol–gel method. To examine the influence of the annealing time on as-prepared films crystallization, the coatings were heated at different temperatures in the range of 500 °C–600 °C for 10, 20, 40 and 80 h. The structure of the obtained material was investigated using the X-ray diffraction...
-
Determination of cyanide in urine and saliva samples by ion chromatography with pulsed amperometric detection
PublikacjaCommonly known as a highly toxic chemical, cyanide is also an essential reagent for many industrial processes. It naturally occurs in plant seeds as a cyanogenic glycosides. Another relatively common mode of cyanide exposure is inhalation of environmental tobacco smoke. This study concerns importance to determine cyanide ion in human biological samples. Urine and saliva samples were collected healthy volunteers exposed to tobacco...
-
Uncertainty of Postmortem Time Estimation Based on Potassium Ion Determination in Vitreous Humor Using Potentiometric Ion-Selective Electrode and Microwave-Induced Plasma with Optical Emission Spectrometry Methods
PublikacjaThere is a need for a reliable and independent evaluation and confirmation of the post-mortem interval (PMI) based on objective factors other than only postmortem changes or temperature measurements. Estimating the PMI by examining the concentration of potassium ions in the vitreous humor (VH) has a tradition in forensic toxicology dating back to the mid-20th century. So far, the methods for determining the presence of potassium...
-
Transition dipole moments of the lithium dimer
PublikacjaIn addition to knowledge of interatomic adiabatic potential energy curves of diatomic systems, it is essential to know electronic transition dipole moments. They are needed in understanding processes like photodissociation, photoassociation, cooling, and trapping. Here, we present electronic transition dipole moments calculated for 74 allowed transitions between 26 states of Li2 [P. Jasik, J.E. Sienkiewicz, Chem. Phys. 323 (2006)...
-
Structural and Transportation Properties of Strontium Titanate Composites with Ion Conductive Oxides
PublikacjaThis paper has been written based on the author’s doctoral dissertation “Structural and transportation properties of strontium and titanate composites with ion conductive oxides”, prepared under the supervision of Prof. Dr. Hab. Eng. Bogusław Kusz at the Department of Solid State Physics of Gdańsk University of Technology. It reports the idea of the thesis and conclusions from the study. Niobium doped strontium titanate (Sr(Ti,Nb)O3)...
-
Michał Michna dr hab. inż.
OsobyJest absolwentem Wydziału Elektrycznego Politechniki Gdańskiej (1998). W 2004 r. uzyskał stopień doktora. Od 2004 r. zatrudniony w Katedrze Energoelektroniki i Maszyn Elektrycznych Politechniki Gdańskiej (asystent, adiunkt, starszy wykładowca). W latach 2010-2015 zastępca kierownik katedry. Jego zainteresowania naukowe i dydaktyczne obejmują szerokie spektrum zagadnień związanych z projektowanie, modelowanie i diagnostyką maszyn...
-
Closed-Loop Control System Design for Wireless Charging of Low-Voltage EV Batteries with Time-Delay Constraints
PublikacjaThis paper presents an inductive power transfer system on the basis of a double single- phase three-level T-type inverter and two split transmitting coils for constant current and constant voltage wireless charging of low-voltage light electric vehicle batteries with closed-loop control, considering time-delay communication constraints. An optimal control structure and a modified control strategy were chosen and implemented to...
-
Unique agreement of experimental and computational infrared spectroscopy: a case study of lithium bromide solvation in an important electrochemical solvent
PublikacjaInfrared (IR) spectroscopy is a widely used and invaluable tool in the studies of solvation phenomena in electrolyte solutions. Using state-of-the-art chemometric analysis of a spectral series measured in a concentration-dependent manner, the spectrum of the solute-affected solvent can be extracted, providing a detailed view of the structural and energetic states of the solvent molecules influenced by the solute. Concurrently,...
-
Determination of Selected Organic Acids in Animal Farm Water Samples by Ion Chromatography
PublikacjaLow molecular mass carboxylic acids (LCAs) occur in many environmental compartments due to natural processes and human activity. They are an important group of organic pollutants of waste water that mainly includes, volatile fatty acids, and also dicarboxylic, aromatic, hydroxy- and ketoacids. LCAs are present in the environment at concentrations between 1 to 5000 ppm and different methods have been reported for their determination...
-
International Journal for Ion Mobility Spectrometry
Czasopisma -
Studies on 16-membered azothia-and azoxythiacrown ethers as ion carriers in ion selective membranes.
Publikacja16-członowe azo iazoksy korony zawierające w makropierścieniu atomy siarki były badane jako nośniki jonów w jonoselektywnych elektrodach membranowych. Związki te badane były pod kątem kompleksowania metali I i II grupy układu okresowego oraz metali ciężkich i przejściowych. Wyznaczone zostały stałe trwałości kompleksów azokoron z wybranymi kationami za pomocą metody sandwiczowej. W wyniku badań potwierdzono tworzenie się silnych...
-
Synthesis, characterization and photocatalytic properties of lithium tantalate
Publikacja -
Preventive Effect of Lithium on “Kleine–Levin Syndrome”
Publikacja -
Analysis of TL and OSL kinetics of lithium aluminate
Publikacja -
Properties of lithium aluminate for application as an OSL dosimeter
Publikacja -
Artificial neural network prophecy of ion exchange process for Cu (II) eradication from acid mine drainage
PublikacjaThe removal of heavy metal ions from wastewater was found to be significant when the cation exchange procedure was used effectively. The model of the cation exchange process was built using an artificial neural network (ANN). The acid mine drainage waste’s Cu(II) ion was removed using Indion 730 cation exchange resin. Experimental data from 252 cycles were recorded. In a column study, 252 experimental observations validated the...
-
Noncryogenic Synthesis of Functionalized 2-Methoxypyridines by Halogen-Magnesium Exchange Using Lithium Dibutyl(isopropyl)magnesate(1-) and Lithium Chloride
Publikacja -
Structural and mechanical properties of hydroxyapatite coatings formed by ion-beam assisted deposition
PublikacjaThe ion-beam assisted deposition (IBAD) is an advanced method capable of producing crystalline coatings at low temperatures. We determined the characteristics of hydroxyapatite Ca10(PO4)6(OH)2 target and coatings formed by IBAD using X-ray photoemission spectroscopy (XPS), X-ray diffraction (XRD), scanning electron microscopy (SEM), atomic force microscopy (AFM) and energy dispersive X-ray (EDX). The composition of the coatings'...
-
A study of cavitation erosion resistance of an ion nitrided titanium alloy by means of the vibration and rotating disk methods
PublikacjaIn this work, a comparative analysis of the cavitation erosion resistance of the Ti– 6.7Al–2.5Mo–1.8Cr–0.5Fe–0.25Si alloy (known as brand VT3-1) before and after lowtemperature ion nitriding is carried out. Two test methods were applied, using vibrative (ASTM G-32) and rotating disk rigs, respectively. The kinetic dependences of the erosive destruction of samples of titanium alloy VT3-1 in the initial state, after ion nitriding...
-
Hydroxide ion hydration in aqueous solutions
PublikacjaHydratacja anionu hydroksylowego w wodnych roztworach wybranych wodorotlenków metali alkalicznych została zbadana przy pomocy spektroskopii oscylacyjnej FTIR HDO izotopowo rozcieńczonej w H2O. Po raz pierwszy zastosowano do badań nad takimi układami ilościową wersję metody widm różnicowych. Pozwoliła ona na wyodrębnienie widma HDO zaburzonej przez substancję rozpuszczoną. Dane spektralne skonfrontowano z optymalnymi strukturami...
-
Simultaneous Removal of Al, Cu and Zn Ions from Aqueous Solutions Using Ion and Precipitate Flotation Methods
PublikacjaThis paper presents the results of investigations concerning the simultaneous removal of Al(III), Cu(II), and Zn(II) from dilute aqueous solutions using ion and precipitate flotation methods. The effects of initial solution pH, surface active substance concentration, and the gas velocity on the flotations’ efficiency and course are studied. Experimental results are discussed in terms of physicochemical aspects related to aqueous...
-
Ion Chromatography with Pulsed Amperometric Detection for Determining Cyanide in Urine and Meconium Samples
PublikacjaThe parents’ addictions and eating habits have a significant influence on the child’s growth. The first stool of a newborn baby provides a large amount of information about xenobiotics transmitted by the mother’s body. The analytical technique used in the study is ion chromatography with pulsed amperometric detection (IC-PAD). The biological samples, which were obtained from women staying in a maternity ward and their partners,...
-
LITHIUM FLUORIDE CRYSTALS AS FLUORESCENT NUCLEAR TRACK DETECTORS
Publikacja -
Application of analytical procedure based on accelerated solvent extraction and ion chromatography technique for determination of thiocyanate and other inorganic ions in human placenta samples
PublikacjaExposure of a pregnant woman during pregnancy is a special case of exposure to toxic substances. Samples of placenta collected for the studies had been prepared with the technique of accelerated solvent extraction and later analyzed for the presence of thiocyanate ion and other inorganic ions, with the use of the technique of ion chromatography. The concentration of thiocyanate ion in placenta samples collected from active smokers...
-
Ion recognition properties of new pyridine-2,6-dicarboxamide bearing propeller-like pendant residues: multi-spectroscopic approach
PublikacjaThe synthesis and ion binding properties of new amide derived from propeller-like tris(2-pyridyl)amine and 2,6-pyridinedicarboxylic acid chloride were described. Amide binds divalent metal cations: copper(II), nickel(II), zinc(II), and lead(II) in acetonitrile. In acetonitrile:water mixture (9:1 v/v) amide interacts only with copper(II) and nickel(II) cations forming complexes of 1:1 stoichiometry. It was found that the introduction...
-
Potentiometric sensor containing set of ion selective electrodes with lipid modified membranes for quality assessment of tested non-alcoholic beverages
PublikacjaPotentiometric sensors may be a good tool for fast quality control of commercial drinks. In this work, such a sensor, containing a set of ion-selective electrodes with lipid-modified membranes (benzylhexadecyldimethylammonium chloride monohydrate, hexadecylamine, 1-dodecanol, elaidic acid, cholesterol) was used for discrimination and quality control of non-alcoholic beverages, mainly composed of sugar and citric acid. It was found...
-
Development of an Analytical Protocol for Determination of Cyanide in Human Biological Samples Based on Application of Ion Chromatography with Pulsed Amperometric Detection
PublikacjaA simple and accurate ion chromatography (IC) method with pulsed amperometric detection (PAD) was proposed for the determination of cyanide ion in urine, sweat, and saliva samples. The sample pretreatment relies on alkaline digestion and application of Dionex OnGuard II H cartridge. Under the optimized conditions, the method showed good linearity in the range of 1–100 μg/L for urine, 5–100 μg/L for saliva, and 3–100 μg/L for sweat...