Wyniki wyszukiwania dla: thermal imaging
-
High-accuracy computation of hard X-ray focusing and imaging for refractive optics
PublikacjaA mathematical apparatus for solving problems of X-ray wave propagation through complex optical systems, when the lens thickness can change with jumps, is developed and presented. The developed method is based on the use of the superposition of oriented Gaussian beams, which satisfy the Helmholtz equation with high accuracy. The wave propagation in air and through kinoform and ordinary lenses is considered. Focusing and imaging...
-
Polarization-sensitive optical coherence tomography for ceramic materials inspection
PublikacjaCeramics production is looking for a fast, reliable and non-destructive method that can be implemented on site for defect detection and analysis. In this paper we present polarization-sensitive optical coherence tomography (PS-OCT) as a method for defect inspection. Proposed extensions to standard OCT provide additional information for complete characterization of tested object. We compare OCT and microscope imaging that can easily...
-
Assessment of Wooden Beams from Historical Buildings Using Ultrasonic Transmission Tomography
PublikacjaThe main goal of this study was non-destructive evaluation of wooden elements using ultrasonic waves. The inspection was carried out on wooden beams from a historical object. Elastic wave signals were processed by ultrasonic transmission tomography to obtain imaging of the internal structure of tested elements without disturbing their state and integrity. The focus was on the influence of wood anisotropy on the propagation of ultrasonic...
-
Maritime traffic situation awareness analysis via high-fidelity ship imaging trajectory
PublikacjaSituation awareness provides crucial yet instant information to maritime traffic participants, and significant attentions are paid to implement traffic situation awareness task via various maritime data source (e.g., automatic identification system, maritime surveillance video, radar, etc.). The study aims to analyze traffic situation with the support of ship imaging trajectory. First, we employ the dark channel prior model to...
-
Damage detection in 3D printed plates using ultrasonic wave propagation supported with weighted root mean square calculation and wavefield curvature imaging
Publikacja3D printing (additive manufacturing, AM) is a promising approach to producing light and strong structures with many successful applications, e.g., in dentistry and orthopaedics. Many types of filaments differing in mechanical properties can be used to produce 3D printed structures, including polymers, metals or ceramics. Due to the simplicity of the manufacturing process, biodegradable polymers are widely used, e.g., polylactide (polylactide...
-
Designing a high-sensitivity dual-band nano-biosensor based on petahertz MTMs to provide a perfect absorber for early-stage non-melanoma skin cancer diagnostic
PublikacjaThe purpose of this study is development of a novel high-performance low-Petahertz (PHz) biosensor for non-melanoma skin cancer (NMSC) diagnosis. The presented device is designed to work within a microwave imaging regime, which is a promising alternative to conventional diagnostic methods such as visual examination, dermoscopy, and biopsy. The suggested biosensor incorporates a dual-band perfect absorber (operating bands at 0.909...
-
Semi-adaptive feedback active control of MRI noise
PublikacjaA feedback controller is proposed for cancellation of magnetic resonance imaging (MRI) noise. The design of the controller takes into account specific features of the MRI noise signal. Simulation results show that a considerable rejection rate of the MRI noise can be obtained.
-
The use of the static thermography in monitoring flap perfusion in breast reconstruction with TRAM flap
PublikacjaThis paper shows results of the static thermography for intraoperative and postoperative imaging of TRAM flap perfusion. The results were compared with the clinical examination of flap perfusion. The study was conducted on a group of 38 female patients who underwent breast reconstruction.
-
Advanced Sensor for Non-Invasive Breast Cancer and Brain Cancer Diagnosis Using Antenna Array with Metamaterial-Based AMC
PublikacjaMicrowave imaging techniques can identify abnormal cells in early development stages. This study introduces a microstrip patch antenna coupled with artificial magnetic conductor (AMC) to realize improved sensor for non-invasive (early-stage) breast cancer and brain cancer diagnosis. The frequency selectivity of the proposed antenna has been increased by the presence of AMC by creating an additional resonance at 2.276 GHz associated...
-
Atomic Force Microscope data post-processing algorithm for higher harmonics imaging
PublikacjaPrevious works have proved that higher harmonics topography imaging using atomic force microscope (AFM) can significantly enhanced its measurement capabilities. Integrated tools dedicated to most of microscopes allow to visualize the investigated surface only by one selected harmonic. Because of the different characteristics of a sample, scanning tip and the environment, appropriate harmonic selection is time consuming and requires...
-
Optimizing of target detection and tracking processes realized on consoles of passive sonar with linear towed antenna
PublikacjaThe long-range passive towed sonar was first modernised a few years ago. Building on operator experience over that period, a concept was developed of optimising the tasks performed by sonar operators, and improving forms of imaging to inform about object detection and support object tracking. The concept was implemented and successfully tested during ships’ manoeuvres. The optimisation of operator tasks was designed to keep listening...
-
LCT, PIV and IR Imaging Detection in Selected Technical and Biomedical Applications
PublikacjaThermochromic liquid crystals (TLC), Particle Image Velocimetry (PIV) and Infrared Imaging Themography (IR) have been successfully used in non-intrusive technical, industrial and biomedical studies and applications. These four tools (based on the desktop computers) have come together during the past two decades to produce a powerful advanced experimental technique as a judgment of quality of information that cannot be obtained...
-
Liquid Crystals, PIV and IR-Photography in Selected Technical and Biomedical Applications
PublikacjaThermochromic liquid crystals (TLC), Particle Image Velocimetry (PIV), Infrared Imaging Themography (IR) and True-Colour Digital Image Processing (TDIP) have been successfully used in non-intrusive technical, industrial and biomedical studies and applications. These four tools (based on the desktop computers) have come together during the past two decades to produce a powerful advanced...
-
Computational Methods for Liver Vessel Segmentation in Medical Imaging: A Review
PublikacjaThe segmentation of liver blood vessels is of major importance as it is essential for formulating diagnoses, planning and delivering treatments, as well as evaluating the results of clinical procedures. Different imaging techniques are available for application in clinical practice, so the segmentation methods should take into account the characteristics of the imaging technique. Based on the literature, this review paper presents...
-
Detection of Alzheimer's disease using Otsu thresholding with tunicate swarm algorithm and deep belief network
PublikacjaIntroduction: Alzheimer’s Disease (AD) is a degenerative brain disorder characterized by cognitive and memory dysfunctions. The early detection of AD is necessary to reduce the mortality rate through slowing down its progression. The prevention and detection of AD is the emerging research topic for many researchers. The structural Magnetic Resonance Imaging (sMRI) is an extensively used imaging technique in detection of AD, because...
-
Reply to Comment on ‘Nanodiamond incorporated human liver mimicking phantoms: prospective calibration medium of magnetic resonance imaging’
PublikacjaDependence of the spin–lattice (T1) relaxation times on the nanodiamond concentration in human liver phantoms is discussed. Factors affecting stability and and reproducibility of these phantoms are presented. The need for comparative measurements on multiple MRI scanners for better understanding of potential variations in the obtained imaging data is emphasised.
-
Combined spline wavelet decomposition for 3d seafloor imaging from multibeam sonar echoes
PublikacjaThe paper proposes combined spline-wavelet approach to the raw echoes seaflor imaging from Multibeam Sonar System (MBSS) records. Wavelet representation is closely related to image representation, due to its unique approximations properties. Splines have the best approximation properties among all known wavelets of a given order, so they are best suited for approximating of smooth seafloor surface. Additionaly, wavelet bases have...
-
An unorthodox view on the problem of tracking facial expressions
PublikacjaRecent developments in imaging cameras has opened a new way of analyzing facial expression. We would like to take advantage from this new technology and present a method of imaging and processing images of human face as a response to the particular stimuli. The response in this case is represented by the facial expressions and the stimuli are still images representing six basic emotions according to Eckmann. Working hypothesis...
-
System for characterisation and multidimensional imaging of seafloor using multibeam sonar data
PublikacjaMultibeam sonars are widely used in applications like high resolution bathymetry measurements, underwater object detection and imaging, etc. Also, they are the promising tool in seafloor characterisation and classification, having several advantages over conventional single beam echosounders. The proposed approach to seafloor classification relies on the combined use of three different techniques. In each of them, a set of descriptors...
-
An unorthodox view on the problem of tracking facial expressions
PublikacjaRecent developments in imaging cameras has opened a new way of analyzing facial expression. We would like to take advantage from this new technology and present a method of imaging and processing images of human face as a response to the particular stimuli. The response in this case is represented by the facial expressions and the stimuli are still images representing six basic emotions according to Eckmann. Working hypothesis...
-
Selection of material for X-ray tomography analysis and DEM simulations: comparison between granular materials of biological and non-biological origins
PublikacjaPhysical properties and X-ray tomography images of five different granular materials: glass bead, glass grit, short grain white rice, sorghum and clay granules (Seramis) are investigated to select the most promising materials for numerical simulations and time-lapse X-ray tomography imaging. The examined materials represent granular materials of non-biological origin (glass bead, glass grit and Seramis) and granular plant materials...
-
New perspective on the in vivo use of cold stress dynamic thermography in integumental reconstruction with the use of skin-muscle flaps
PublikacjaAmong the problems encountered by plastic surgeons is the reconstruction of defects following tumors. One of the reconstructive options is TRAM flap. Despite that anatomy is well-explored, marginal flap necrosis may develop. To minimize complications imaging examinations was designed to determine the degree of flap perfusion. One of them is the thermographic examination.
-
Advanced polarization sensitive analysis in optical coherence tomography
PublikacjaThe optical coherence tomography (OCT) is an optical imaging method, which is widely applied in variety applications. This technology is used to cross-sectional or surface imaging with high resolution in non-contact and non-destructive way. OCT is very useful in medical applications like ophthalmology, dermatology or dentistry, as well as beyond biomedical fields like stress mapping in polymers or protective coatings defects detection....
-
HDAC Inhibitors: Innovative Strategies for Their Design and Applications
PublikacjaHistone deacetylases (HDACs) are a large family of epigenetic metalloenzymes that are involved in gene transcription and regulation, cell proliferation, differentiation, migration, and death, as well as angiogenesis. Particularly, disorders of the HDACs expression are linked to the development of many types of cancer and neurodegenerative diseases, making them interesting molecular targets for the design of new efficient drugs...
-
Non-Destructive Diagnostics of Concrete Beams Strengthened with Steel Plates Using Modal Analysis and Wavelet Transform
PublikacjaExternally bonded reinforcements are commonly and widely used in civil engineering objects made of concrete to increase the structure load capacity or to minimize the negative effects of long-term operation and possible defects. The quality of adhesive bonding between a strengthened structure and steel or composite elements is essential for effective reinforcement; therefore, there is a need for non-destructive diagnostics of adhesive...
-
Nanodiamond phantoms mimicking human liver: perspective to calibration of T1 relaxation time in magnetic resonance imaging
PublikacjaPhantoms of biological tissues are materials that mimic the properties of real tissues. This study shows the development of phantoms with nanodiamond particles for calibration of T1 relaxation time in magnetic resonance imaging. Magnetic resonance imaging (MRI) is a commonly used and non-invasive method of detecting pathological changes inside the human body. Nevertheless, before a new MRI device is approved for use, it is necessary...
-
Quantitative Analysis of Biofilm Formed on Vascular Prostheses by Staphylococcus Epidermidis with Different ica and aap Genetic Status
PublikacjaOBJECTIVES: This study aims to examine biofilm formed on vascular prostheses by Staphylococcus epidermidis with different ica and aap genetic status, and to evaluate the effect of antibiotic-modified prostheses on bacterial colonization. METHODS: Biofilm formation was determined using fluorescence microscopy imaging. Quantitative analysis was conducted using the biofilm coverage ratio (BCR) calculations. RESULTS: Our investigations...
-
Effects of laser pulse duration in two-photon vision threshold measurements
PublikacjaPulsed near-infrared (NIR) light sources can be successfully applied for both imaging and functional testing of the human eye, as published recently1. These two groups of applications have different requirements. For imaging applications, the most preferable is invisible scanning beam while efficiently visible stimulating beam is preferable for functional testing applications. The functional testing of human eye using NIR laser...
-
Highly porous nanoberyllium for X-ray beam speckle suppression
PublikacjaThe speckle suppressor device containing highly porous nanoberyllium is proposed for manipulating with the spatial coherence length and removing undesirable speckle structure during the imaging experiments. We report a special device called the speckle suppressor, which contains the highly porous nanoberyllium plate, compacted from both sides by two beryllium windows. By insertion the speckle suppressor in the X-ray beam it allows...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 33 mA. Sample 51.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 33 mA.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface emission....
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 336 mA. Sample 71.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 336 mA. Sample 71.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 54 mA. Sample 61.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 54 mA. Sample 61.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 400 mA. Sample 42.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 400 mA. Sample 42.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 162 mA. Sample 61.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 162 mA. Sample 61.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 51 mA. Sample 51.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 51 mA.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface emission....
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 480 mA. Sample 42.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 480 mA. Sample 42.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,0 V at 561 mA. Sample 71.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,0 V and discharged to 10 mV by constant current 561 mA. Sample 71. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 27 mA. Sample 61.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 27 mA. Sample 61.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 112 mA. Sample 71.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 112 mA. Sample 71.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 108 mA. Sample 61.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 108 mA. Sample 61.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 135 mA. Sample 61.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 135 mA. Sample 61.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,4 V at 562 mA. Sample 71.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,4 V and discharged to 10 mV by constant current 562 mA. Sample 71.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 240 mA. Sample 42.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 240 mA. Sample 42.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 224 mA. Sample 71.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 224 mA. Sample 71.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 320 mA. Sample 42.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 320 mA. Sample 42.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 392 mA. Sample 71.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 392 mA. Sample 71.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 58 mA. Sample 82.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 58 mA. Sample 82.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 81 mA. Sample 61.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 81 mA. Sample 61.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 56 mA. Sample 71.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 56 mA. Sample 71.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 280 mA. Sample 71.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 280 mA. Sample 71.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...