Wyniki wyszukiwania dla: H-3(+)
-
Structure, Physicochemical and Biological Properties of an Aqua (2,2′,2′′-Nitrilotriacetato)-oxidovanadium(IV) Salt with 4-Methylpyridinium Cation
PublikacjaThe crystal structure of a nitrilotriacetate (nta) oxidovanadi-um(IV) salt with 4-methylpyridinium cation, [4-Me(Py)H]+, of [4-Me(Py)H][VO(nta)(H2O)] stoichiometry was determined. The com-plex comprises a discrete mononuclear [VO(nta)(H2O)]–coordinationentity that can be rarely found among other known compounds con-taining nitrilotriacetate oxidovanadium(IV) moieties. The complex wascharacterized by spectroscopic (IR and EPR) methods,...
-
Long-term measurement of physiological parameters - patient 4 (serie 1)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (3 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 4 (serie 2)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (3 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 6 (serie 7)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (3 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 7 (serie 5)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (3 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 7 (serie 1)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (3 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 5 (serie 10)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (3 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 7 (serie 4)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (3 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 7 (serie 1)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (3 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 6 (serie 19)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (3 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 7 (serie 22)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (3 hours) measurement of physiological parameters of the healthy volunteer (female,...
-
Long-term measurement of physiological parameters - patient 7 (serie 12)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (3 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 7 (serie 13)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (3 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Comparison of bacterial production in the water column between two Arctic fjords, Hornsund and Kongsfjorden (West Spitsbergen)
PublikacjaBacterial production and the accompanying environmental factors were measured in the water columns of two Arctic fjords during the cruise in July and August 2013. Water samples were collected at six stations located in the central part of Hornsund and Kongsfjorden. In Hornsund, where average water temperatures were 1.25-fold lower than in Kongsfjorden, the bacterial production was twice as high (0.116 ± 0.102 vs 0.05 ± 0.03 mg...
-
Activation of the C=P bond in phosphanylphosphaalkenes C=P–P bond system) in the reaction with nucleophilic reagents: MeLi, nBuLi and tBuLi
PublikacjaThree reactions of phosphanylphosphaalkene (1) with nucleophiles were performed to activate the diphosphorus monomer. We observed similar results in the reactions with MeLi and nBuLi, in which the P–P bond is cleavaged and triphosphorus systems [P(Me)2–CH(biph)–CH(biph)–P–(PtBu 2)]- (1a'') and [P(nBu)2–CH(biph)–CH(biph)–P–(PtBu 2)]- (1b''), respectively, are formed depending on the nucleophilic reagent (biph ¼ biphenyl). In the...
-
Experimental and theoretical investigation of conformational states and noncovalent interactions in crystalline sulfonamides with a methoxyphenyl moiety
PublikacjaFour sulfonamide derivatives with a methoxyphenyl moiety, namely N-{4-[(2-methoxyphenyl)sulfamoyl] phenyl}acetamide (1a), N-{4-[(3-methoxyphenyl)sulfamoyl]phenyl}acetamide (1b), 4-amino-N-(2- methoxyphenyl)benzenesulfonamide (2a) and 4-amino-N-(3-methoxyphenyl)benzenesulfonamide (2b), have been synthesized and characterized physiochemically by CHNS, MS, FT-IR, 1H NMR, 13C NMR, PXRD and TG methods. Crystal structures were determined...
-
The structure of strontium–borate glass-ceramics containing crystalites of Bi2VO5.5. measured with X-ray diffraction and SEM methods
Dane BadawczeThe structure of strontium–borate glass-ceramics containing Bi2VO5.5 crystallites was measured by XRD and SEM.
-
Influence of the particle size of carbonate-siliceous rock on the efficiency of phosphorous removal from domestic wastewater
PublikacjatThe aim of the study was to determine the influence of the particle size of carbonate–silica rock (opoka)used in rock filters on the efficiency of phosphorus removal from domestic wastewater. The investigationswere carried out in a laboratory using a model consisting of three vertical flow filters with carbonate–silicarock of different particle sizes (G1= 1–2 mm; G2= 2–5 mm; G3= 5–10 mm). The tested rock was subjectedto decarbonising...
-
Wałcz 2018 - video data - pedestrian, bicycles, vehicles
Dane BadawczeWałcz DK 10 - 2018 - video data - pedestrian, bicycles, vehicles
-
Marek Czachor prof. dr hab.
Osoby -
The topography of as-quenched and heat treated 50(2Bi2O3-V2O5)-50SrB4O7 and 50Bi2VO5.5-50SrB4O7 glasses measured with confocal microscope
Dane BadawczeThe topography of as-quenched and heat treated 50(2Bi2O3-V2O5)-50SrB4O7 and 50Bi2VO5.5-50SrB4O7 glasses measured with confocal microscope.
-
Video traffic data - Interchange Karczemki (S6-501)
Dane BadawczeThe data includes video traffic data registered with 5 video cameras at weaving area (weaving section type A) of the Karczemki interchange within S6 expressway in Poland (interchange of expressway S6 and regional road 501), located in the Tri-City Agglomeration . The data covers the one day: 10.10.2017 (expressway S6).
-
The topography of as-quenched and heat treated 50(2Bi2O3-V2O5)-50SrB4O7 and 50Bi2VO5.5-50SrB4O7 glasses measured with AFM
Dane BadawczeThe topography of as-quenched and heat treated 50(2Bi2O3-V2O5)-50SrB4O7 and 50Bi2VO5.5-50SrB4O7 glasses measured with AFM.
-
Video traffic data - Interchange Gdansk Poludnie (S6-S7), Poland
Dane BadawczeThe data includes video traffic data registered with 8 video cameras at exit and entry lanes of the Gdansk Poludnie interchange within S6 expressway in Poland (interchange of expressway S6 and S7), located in the Tri-City Agglomeration . The data covers the two days: 4.08.2020 and 6.08.2017 (expressway S6).
-
Video traffic data - Interchange Skawina (A4-44), Poland
Dane BadawczeThe data includes video traffic data registered with 5 video cameras at entry and exit lanes of the Skawina interchange within A4 motorway in Poland (interchange of motorway A4 and national road 44), located in the Krakow Agglomeration. The data covers the one day: 31.08.2017 (motorway A4).
-
Video traffic data - Interchange Krakow Poludnie (A4-7), Poland
Dane BadawczeThe data includes video traffic data registered with 5 video cameras at entry and exit lanes of the Krakow Poludnie interchange within A4 motorway in Poland (interchange of motorway A4 and national road 7), located in the Krakow Agglomeration. The data covers the one day: 29.08.2017 (motorway A4).
-
Video traffic data - Interchange Lotnisko (S6-472) - Exit +entry lanes, Poland
Dane BadawczeThe data includes video traffic data registered with 6 video cameras at entry or exit lanes of the Lotnisko interchange within S6 expressway in Poland (interchange of expressway S6 and regional road 472), located in the Tri-City Agglomeration. The data covers the two days: 10.04.20187 and 12.04.2017(expressway S6).
-
(2R)-N-{3-[Bis(methylsulfanyl)methyleneamino]-propionoyl}bornane-10,2-sultam
PublikacjaW strukturze związku tytułowego występują słabe oddziaływania C-H...S oraz C-H...O.
-
Złocieniec 2021- video data - pedestrian, bicycles, vehicles
Dane BadawczeZłocieniec 2021- video data - pedestrian, bicycles, vehicles
-
Results of SEM examination of chitosan/Eudragit E 100 coatings electrophoretically deposited on the Ti grade 2 substrate
Dane BadawczeThe database contains the images of the microstructure of the coatings observed with the SEM scanning electron microscope. The chitosan/Eudragit E 100 coatings deposited on the Ti grade 2 substrate by an electrophoresis process were tested. Different process parameters like Eudragit E 100 concentration (0.25 g and 0.5 g in 100 mL of 1% (v/v) acetic...
-
The computational complexity of the backbone coloring problem for planar graphs with connected backbones
PublikacjaIn the paper we study the computational complexity of the backbone coloring problem for planar graphs with connected backbones. For every possible value of integer parameters λ≥2 and k≥1 we show that the following problem: Instance: A simple planar graph GG, its connected spanning subgraph (backbone) HH. Question: Is there a λ-backbone coloring c of G with backbone H such that maxc(V(G))≤k? is either NP-complete or polynomially...
-
HS-SPME-CGC-PID determination of aldehydes in rectified spirits and vodkas after derivatisation with 2,4,6-trichlorophenylhydrazine (TCPH)
PublikacjaW pracy przedstawiono nową metodę oznaczania aldehydów w spirytusach i wyrobach spirytusowych czystych z zastosowaniem 2,4,6-trichlorofenylohydrazyny (TCPH) jako odczynnika derywatyzującego. Zaproponowana metoda jest co najmniej 100-krotnie tańsza od mikroekstrakcji do fazy stacjonarnej z fazy nadpowierzchniowej (HS-SPME) i chromatografii gazowej z zastosowaniem często zalecanej o-2,3,4,5,6-pentafluorobenzylohydroxyloaminy (PFBHA)....
-
Continuation classes for a non-linear Leslie population model with 3 varying parameters
Dane BadawczeThis dataset contains selected results of rigorous numerical computations conducted in the framework of the research described in the paper "A database schema for the analysis of global dynamics of multiparameter systems" by Z. Arai, W. Kalies, H. Kokubu, K. Mischaikow, H. Oka, P. Pilarczyk, published in SIAM Journal on Applied Dynamical Systems (SIADS),...
-
The electrochemical impedance spectroscopy studies of the anode material based on polymer and starch derived ceramic for lithium ion batteries
PublikacjaThe anode materials derived of preceramic polymer poly(1,2-dimethylsilazane) (PSN) and starch was study. Commercially available polysilazane (poly(1,2-dimethylsilazane (PSN 2M01 Gelest) was mixed with commercially available starch (POCH Gliwice). The ratio polymer/starch (PSN/starch) was 1/1 or 3/7. The polysialazane/starch blend was cross-linked at 230 ºC for 2 h followed by heating to the final temperature (500 ºC, 700 ºC and...
-
Milicz 2019 - video data - pedestrian, bicycles, vehicles
Dane BadawczeMilicz 2019 - video data - pedestrian, bicycles, vehicles
-
Stargard 2021- video data - pedestrian, bicycles, vehicles
Dane BadawczeStargard 2021- video data - pedestrian, bicycles, vehicles
-
The topography of Bi2VO5.5 ceramic measured with SEM and confocal microscope
Dane BadawczeThe topography of Bi2VO5.5 ceramics was measured by SEM and confocal microscope.
-
Atom-economic thiophosphoroselenenylations of C–H acid esters and amides
PublikacjaThree improved thiophosphoroselenenylation procedures of CHacids, including derivatives of malonic and acetyl-, phosphono-, 4-nitrophenyl- and 3-pyridylacetic acids, have been described and compared to previously reported thiophosphoroselenylation of diethyl malonate using bis(disopropoxyphosphinothioyl)diselenide alone or with the aid of methyl iodide. The use of iodine makes it possible to utilize both equivalents of the selenenylating...
-
Long-term measurement of physiological parameters - adult (120 minutes)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (120 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters.
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 90 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (60 minutes)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters (4)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 90 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (4)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 120 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - adult (1)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 120 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (2)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 120 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters (2)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 90 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (1)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 110 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 6th serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 5 serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) 1 serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...