Wyniki wyszukiwania dla: TEMPERATURE MEASUREMENTS
-
Long-Term Measurement of Physiological Parameters – Child Dataset
PublikacjaThe dataset titled “Long-term measurement of physiological parameters – child is one dataset” of the bigger series named Long-term measurement of physiological parameters. The dataset contains physiological parameter measurements such as skin temperature and resistance, blood pulse, as well as the stress detection marker, which can have a value of 0 when there is no stress detected or 1 when stress appeared. Additionally, the dataset...
-
Prediction of cast-in-place concrete strength of the extradosed bridge deck based on temperature monitoring and numerical simulations
PublikacjaThe work is devoted to the implementation of a monitoring system for high performance concrete embedded in the span of an extradosed bridge deck using a modified maturity method augmented by numerical simulations conducted by the authors’ FEM code. The paper presents all research stages of bridge construction and considers the conclusions drawn from the results of laboratory tests, field measurements, and numerical calculations....
-
Investigation of electrocatalytic gas sensor properties in presence of chlorine
PublikacjaIn this paper performance of an electrocatalytic sensor in presence of chlorine is investigated. Presented studies concern sensor prepared in ceramic technology based on NASICON as a solid electrolyte with two round shaped platinum electrodes. Measurements in different temperatures have been performed in order to determine optimal sensor working temperature.
-
Electrical and noise responses of carbon nanotube networks enhanced by UV light for nitrogen dioxide sensing
Dane BadawczeNetworks consisting of randomly oriented carbon nanotubes (CNN) were investigated toward nitrogen dioxide detection by means of electrical and low-frequency noise measurements. UV-activation of CNN layers improved gas sensitivity and reduced the limit of detection, especially by employing 275 nm-LED. This data set includes DC resistance measurements...
-
Influence of CeO2 and TiO2 Particles on Physicochemical Properties of Composite Nickel Coatings Electrodeposited at Ambient Temperature
PublikacjaThe Ni-TiO2 and Ni-CeO2 composite coatings with varying hydrophilic/hydrophobic characteristics were fabricated by the electrodeposition method from a tartrate electrolyte at ambient temperature. To meet the requirements of tight regulation by the European Chemicals Agency classifying H3BO3 as a substance of very high concern, Rochelle salt was utilized as a buffer solution instead. The novelty of this study was to implement a...
-
Isothermal Calorimetry and Compressive Strength Tests of Mortar Specimens for Determination of Apparent Activation Energy
PublikacjaThe hydration process of cementitious materials involves a thermally activated reaction that depends on the composition of the mixture and the curing temperature. The main parameter affecting the temperature variation of cast-in-place concrete is the apparent activation energy, which can be used for the efficient prediction of the temperature evolution and maturity index of hardening concrete. This paper discusses two methods to...
-
Linear impedance of 50Bi2VO5.5-50SrB4O7 glass measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe linear electrcial properties of 50Bi2VO5.5-50SrB4O7 glass was measured by impedance spectroscopy method.
-
Adoption of the F-statistic of Fisher-Snedecor distribution to analyze importance of impact of modifications of injector opening pressure of a compression ignition engine on specific enthalpy value of exhaust gas flow
PublikacjaThis article analyzes the effect of modifications of injector opening pressure on the operating values of a compression ignition engine, including the temperature of the fumes. A program of experimental investigation is described, considering the available test stand and measurement capabilities. The structure of the test stand on which the experimental measurements were conducted is presented. The method of introducing real modifications...
-
Short-term measurement of physiological parameters - child (2)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (5 minutes) measurements of physiological parameters were performed on the healthy...
-
Linear impedance of as-quenched 40Bi2VO5.5-60SrB4O7 glass measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe linear electrcial properties of 40Bi2VO5.5-60SrB4O7 glass was measured by impedance spectroscopy method.
-
Measurement of mass flow of viscous liquid through a Cylindrical Orifice under laminar flow (CylOr)
Dane BadawczeThe data was obtained as part of the project "Measurement of mass flow of viscous liquid through a Cylindrical Orifice under laminar flow (CylOr)", in which flow tests of hydraulic oil through a cylindrical orifice with a thickness of l = 25 mm and a throat b = 0.5 (diameter pipes D = 50 mm, orifice diameter d = 25 mm) on the test stand at the Department...
-
Effective density of airborne wear particles from car brake materials
PublikacjaPeople living in urban environments are subject to high health risks due to various anthropogenic sources of airborne particulate matter, including wear of transport vehicle brakes. Studies of airborne particles often require an estimate of the effective particle density, a property that allows correct matching of mass and size characteristics measured by different aerosol instruments. In this study we investigated the effective...
-
Low temperature growth of diamond films on optical fibers using Linear Antenna CVD system
PublikacjaIt is not trivial to achieve a good quality diamond-coated fibre interface due to a large difference in the properties and composition of the diamond films (or use coating even) and the optical fibre material, i.e. fused silica. One of the biggest problems is the high temperature during the deposition which influences the optical fibre or optical fibre sensor structure (e.g. long-period gratings (LPG)). The greatest advantage of...
-
Linear impedance of 40Na2O-20CaO-40P2O5 glass measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe linear electrical properties of 40Na2O-20CaO-40P2O5 glass was measured by impedance spectroscopy method.
-
APPLICATION OF INFRARED THERMOGRAPHY TO NON-CONTACT TESTING OF AD/DC POWER SUPPLY
PublikacjaTesting of AC/DC power supplies using the thermography was carried out in order to assess their assembly and operation correctness before launching them on the market. The investigation was carried out for 17 AC/DC power supplies which passed the standard tests (measurements of their basic parameters and characteristics). The investigation consisted of two steps. In the first step the dispersion of temperature on power supply boards...
-
Superconductivity in the superhard boride WB4.2
PublikacjaWe show that the superhard boride WB4.2 is a superconductor with a Tc of 2.05(5) K. Temperature-dependent magnetic susceptibility, electrical resistivity, and specific heat measurements were used to characterize the superconducting transition. The Sommerfeld constant γ for WB4.2 is 2.07(3) mJ mol−1 K−2 and the ΔC/γTc=1.56, which is somewhat higher than what is expected for weakly coupled Bardeen–Cooper–Schrieffer type superconductors....
-
Linear impedance of Bi2VO5.5 glass-ceramic annealed at 423 K measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe linear electrical properties of Bi2VO5.5 glass-ceramic annealed at 423 K prepared by traditional melt quenching technique was measured by impedance spectroscopy method.
-
Effect of Time Varying Measurement Conditions on Antenna Pattern in Near Field Measurement and Its Correction Procedure
PublikacjaAuthors present the procedure of taking into account the changes of electrical parameters of setup due to the time drift of temperature during the procedure of near field measurement. It is proposed to make additional measurements in determined positions of probe are next used the results to introduce corrections terms in measured data. Such approach was verified practically in experimental near field measurement system.
-
Superconductivity in the niobium-rich compound Nb5Se4
PublikacjaThe niobium rich selenide compound Nb5Se4 was synthesized at ambient pressure by high-temperature solid–state reaction in a sealed Ta tube. Resistivity and heat capacity measurements reveal that this compound is superconducting, with a Tc = 1.85K. The electronic contribution to the specific heat γ and the Debye temperature are found to be 18.1 mJmol−1K−2 and 298 K respectively. The calculated electron-phonon coupling constant λep...
-
Numerical simulation of hardening of concrete plate
PublikacjaThe paper presents a theoretical formulation of concrete curing in order to predict temperature evolution and strength development. The model of heat flow is based on a well-known Fourier equation. The numerical solution is implemented by means of the Finite Difference Method. In order to verify the model, the in situ temperature measurements at the top plate of a road bridge were carried out. A high agreement between numerical...
-
Tunable Dielectric Switching of (Quinuclidinium)[MnCl4] Hybrid Compounds
PublikacjaInorganic−organic hybrid QMnCl (Q = quinuclidinium) crystals were synthesized and characterized. The X-ray and variable-temperature IR/Raman analysis demonstrate that the crystals undergo a reversible structural phase transition, which originates from an order−disorder process and is related to the dynamics of the organic Q cation. Dielectric function measurements disclose a switchability between low (“OFF”) and high (“ON”) dielectric...
-
Linear impedance of vanadate glasses containing BaTiO3
Dane BadawczeThe linear impedance of vanadate glasses doped with BaTiO3 was measured. Samples of the composition of x[BaO,TiO2]–(80 − x)V2O5–20Bi2O3 where x = 5, 10 and 15 in mol% were prepared by a conventional melt quenching technique. The melting was performed in alumina crucibles at the temperature of 1273 K–1373 K. The melts were poured on a preheated (573...
-
Linear impedance of 50(2Bi2O3-V2O5)-50SrB4O7 glass measured with impedance spectroscopy method at high temperature region
Dane BadawczeThe linear electrcial properties of 50(2Bi2O3-V2O5)-50SrB4O7 glass was measured by impedance spectroscopy method.
-
Polypyrrole based gas sensor for ammonia detection
PublikacjaThe nature of polypyrrole response to toxic gases does not allow using the sensor in a conventional way. The main aim of this study is to acquire the information about the concentration using different approaches: a linear approximation, a non-linear approximation and a tangent method. In this paper a two-steps procedure for sensor response measurements has been utilized. Polypyrrole films were electrochemically synthesized on...
-
The structure of strontium–borate glasses and glass-ceramics containing bismuth and vanadium oxides measured with X-ray diffraction method
Dane BadawczeThe structure of strontium–borate glasses and glass-ceramics containing bismuth and vanadium oxides was measured by XRD.
-
Linear impedance of 58(2Bi2O3-V2O5)-42SrB4O7 glass heat-treated for 3 hours at 693 K, measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe linear electrcial properties of partially crystallized 58(2Bi2O3-V2O5)-42SrB4O7 glass was measured by impedance spectroscopy method.
-
Linear impedance of 58(2Bi2O3-V2O5)-42SrB4O7 glass heat-treated for 10 hours at 693 K, measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe linear electrcial properties of partially crystallized 58(2Bi2O3-V2O5)-42SrB4O7 glass was measured by impedance spectroscopy method.
-
XPS analysis of the GO based materials
Dane BadawczeGraphene oxides samples were measured by XPS method. The X-ray photoemission spectroscopy measurements were carried out with Omicron NanoTechnology UHV equipment. The hemispherical spectrophotometer was equipped with a 128-channel collector. The XPS measurements were performed at room temperature at a pressure below 1.1 × 10−8 mBar. The photoelectrons...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) - the 2nd serie
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (105 minutes)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (105 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (100 minutes)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (100 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - an adult (100 minutes)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (100 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - an adult (70 minutes)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (70 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 min)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - an adult (60 minutes)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (120 min)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (120 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - patient 1 (serie 5)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 3 (serie 11)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 2 (serie 20)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 1 (serie 11)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 3 (serie 22)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 4 (serie 17)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 4 (serie 3)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (4 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 1 (serie 15)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 2 (serie 11)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (6 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 1 (serie 22)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (4 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 1 (serie 10)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 4 (serie 12)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 1 (serie 14)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 3 (serie 15)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...