Wyniki wyszukiwania dla: Project Testing
-
Astrocytoma, NOS - Unknown, 41 - Tissue image [3300730069392001]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Glioblastoma, NOS - Unknown, 33 - Tissue image [3290730016642701]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Glioblastoma, NOS - Unknown, 33 - Tissue image [3290730016645001]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Astrocytoma, NOS - Unknown, 41 - Tissue image [3300730069393771]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Astrocytoma, NOS - Unknown, 41 - Tissue image [3300730069399021]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Glioblastoma, NOS - Unknown, 33 - Tissue image [3290730016646661]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Astrocytoma, NOS - Unknown, 41 - Tissue image [3300730069394051]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
T-cell lymphoma, NOS - Unknown, 74 - Tissue image [3290730016639051]
Dane BadawczeThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Glioblastoma, NOS - Unknown, 33 - Tissue image [3290730016643591]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Glioblastoma, NOS - Unknown, 33 - Tissue image [3290730016646091]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Astrocytoma, NOS - Unknown, 41 - Tissue image [3300730069393551]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
T-cell lymphoma, NOS - Unknown, 74 - Tissue image [3300730069442961]
Dane BadawczeThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Astrocytoma, NOS - Unknown, 41 - Tissue image [3300730069398071]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
T-cell lymphoma, NOS - Unknown, 74 - Tissue image [3290730016634721]
Dane BadawczeThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
T-cell lymphoma, NOS - Unknown, 74 - Tissue image [3290730016632461]
Dane BadawczeThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
T-cell lymphoma, NOS - Unknown, 74 - Tissue image [3290730016632951]
Dane BadawczeThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
T-cell lymphoma, NOS - Unknown, 74 - Tissue image [3290730016635621]
Dane BadawczeThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Glioblastoma, NOS - Unknown, 33 - Tissue image [3290730016648091]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Astrocytoma, NOS - Unknown, 41 - Tissue image [3300730069393431]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Glioblastoma, NOS - Unknown, 33 - Tissue image [3290730016643681]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
T-cell lymphoma, NOS - Unknown, 74 - Tissue image [3290730016639551]
Dane BadawczeThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
T-cell lymphoma, NOS - Unknown, 74 - Tissue image [3290730016637461]
Dane BadawczeThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Glioblastoma, NOS - Unknown, 33 - Tissue image [3290730016646541]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
T-cell lymphoma, NOS - Unknown, 74 - Tissue image [3290730016635201]
Dane BadawczeThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Astrocytoma, NOS - Unknown, 41 - Tissue image [3300730069399951]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Astrocytoma, NOS - Unknown, 41 - Tissue image [3300730069391171]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Astrocytoma, NOS - Unknown, 41 - Tissue image [3301001549114131]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Glioblastoma, NOS - Unknown, 33 - Tissue image [3290730016649081]
Dane BadawczeThis is the histopathological image of BRAIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Testing of DES toxicity towards Candida subhashii
Dane BadawczeDataset presents results of testing toxicity of selected DES solutions in mineral salt medium towards Candida subhashii.
-
Microscopic examination of CuNiFeR pipeline
Dane BadawczeCopper and nickel alloys called cunifers (Cu, Ni, Fe and R – rest of alloy elements) have found wide application in the production of ship pipeline components in contact with sea water, such as, for example, the main engine cooling system. These alloys are characterized by a very high corrosion resistance, which is ensured by appropriately carried out...
-
Macroscopic examination of CuNiFeR pipeline
Dane BadawczeCopper and nickel alloys called cunifers (Cu, Ni, Fe and R – rest of alloy elements) have found wide application in the production of ship pipeline components in contact with sea water, such as, for example, the main engine cooling system. These alloys are characterized by a very high corrosion resistance, which is ensured by appropriately carried out...
-
Ultrasonic wave propagation, digital image correlation and X-ray micro-computed tomography measurements of concrete during splitting (cube #3)
Dane BadawczeThe DataSet contains the results of the mechanical behaviour of a concrete cube under the splitting test. The cube had dimensions 70 x 70 x 70 cm3 and was made of concrete with the following ingredients: cement type CEM I 42.5R (330 kg/m3), water (165 kg/m3), aggregate 0/2 mm (710 kg/m3), aggregate 2/8 mm (664 kg/m3), aggregate 8/16 mm (500 kg/m3),...
-
Ultrasonic wave propagation, digital image correlation and X-ray micro-computed tomography measurements of concrete during splitting (cube #1)
Dane BadawczeThe DataSet contains the results of the mechanical behaviour of a concrete cube under the splitting test. The cube had dimensions 70 x 70 x 70 cm3 and was made of concrete with the following ingredients: cement type CEM I 42.5R (330 kg/m3), water (165 kg/m3), aggregate 0/2 mm (710 kg/m3), aggregate 2/8 mm (664 kg/m3), aggregate 8/16 mm (500 kg/m3),...
-
Ultrasonic wave propagation, digital image correlation and X-ray micro-computed tomography measurements of concrete during splitting (cube #4)
Dane BadawczeThe DataSet contains the results of the mechanical behaviour of a concrete cube under the splitting test. The cube had dimensions 70 x 70 x 70 cm3 and was made of concrete with the following ingredients: cement type CEM I 42.5R (330 kg/m3), water (165 kg/m3), aggregate 0/2 mm (710 kg/m3), aggregate 2/8 mm (664 kg/m3), aggregate 8/16 mm (500 kg/m3),...
-
Ultrasonic wave propagation, digital image correlation and X-ray micro-computed tomography measurements of concrete during splitting (cube #2)
Dane BadawczeThe DataSet contains the results of the mechanical behaviour of a concrete cube under the splitting test. The cube had dimensions 70 x 70 x 70 cm3 and was made of concrete with the following ingredients: cement type CEM I 42.5R (330 kg/m3), water (165 kg/m3), aggregate 0/2 mm (710 kg/m3), aggregate 2/8 mm (664 kg/m3), aggregate 8/16 mm (500 kg/m3),...
-
A history of the physical and chemical stability of pharmaceuticals : a review
Publikacja: There is a great need for a broad range review of stability tests of active pharmaceutical ingredients (APIs) in comparison with current requirements contained in the pharmacopoeia. This review focuses on a pharmaceutical history of physical and chemical stability determination. Traditional knowledge must be considered in the context of physical stability, while new knowledge must be applied and acquired in terms of identification...
-
Comparison of natural frequencies of a circular saw blade obtained empirically and with FEM
PublikacjaThe knowledge of the natural frequencies’ values of circular saw blades is necessary to determine the minimal critical rotational speed in which they can work with required stability. Moreover, testing the circular saw blades with more complicated shapes, e.g. which have additional holes inside blades for cleaning knifes or additional indirect teeth in gullets, reveals some kind of problematic properties of these saw blades. The...
-
On a design of a torque sensor for the iCub humanoid robot
PublikacjaThe paper presents the evaluation process of a first version of the one axis torque sensor designed for the iCub humanoid robot. Newly designed strain gauges equipped sensor was found to show a significant readouts hysteresis, therefore several tests were run to define the reason of the hysteresis. Some of the design issues met while testing the new sensor are discussed including the screws connection and relative rigidity of the...
-
Acoustic journal bearing – Performance under various load and speed conditions speed conditions
PublikacjaThe paper presents results of experimental testing aiming at finding out what effect system of piezo-electric actuators (PZTs)attached to an aerodynamic journal bearing has on the magnitude of shaft's motion within the bearing operating at specified speed and load. The results clearly demonstrate effectiveness of PZTs in mitigating the shaft's motion thus contributing to the increased stability of the bearing. This stabilizing...
-
Acoustic journal bearing - A search for adequate configuration
PublikacjaClassical non-contact bearings are already used in a number of specialist applications but there are somespecialist areas where they cannot be used for variety of reasons and acoustic sliding bearings could be an alternative. The paper presents the quest for a configuration of an acoustic journal bearing and shows that the overall shape of the bearing and its geometry are of a vital importance for the load capacity oft he bearing....
-
Automotive Validation Functions for On-line Test Evaluation of Hybrid Real-time Systems
PublikacjaThe aim of this paper is to present the means of black-box on-line test evaluation for hybrid real-time systems. The described procedures can be used for the model-based testing process so as to improve its effectiveness. In particular, intelligent automotive validation functions are considered, which are divided into different types depending on the nature of the evaluated issue. All provided definitions are specified on the meta-model...
-
Quality of Test Specification by Application of Patterns
PublikacjaEmbedded system and software testing requires sophisticated methods, which are nowadays frequently supported by application of test patterns. This eases the test development process and contributes to the reusability and maintainability of the test specification. However, it does not guarantee the proper level of quality and test coverage in d ifferent dimensions of the test specification. In this paper the quality of the test...
-
A method of earth fault loop impedance measurement without unwanted tripping of RCDs
PublikacjaIn low-voltage networks, earth fault loop impedance (EFLI) measurement is the basis for assessing the effectiveness of automatic disconnection of supply. Such a measurement is performed during initial and periodical verification, especially in a TN low-voltage network. Nowadays, due to widespread application of residual current devices (RCDs), such test is difficult in many circuits because RCDs operate during the test. In this...
-
COLD CRACKING OF S460N STEEL WELDED IN WATER ENVIRONMENT
PublikacjaThis paper shows results of weldability testing of fine-grained high -strength low- alloy S460N steel welded in water environment by covered electrodes. The tests were carried out by using the CTS test specimens with fillet welds. Four specimens were welded under water and one specimen in air. Welded joints were subjected to non-destructive visual and penetration tests. The accepted joints were then subjected to macroscopic and...
-
Characterization of fracture process in polyolefin fibre-reinforced concrete using ultrasonic waves and digital image correlation
PublikacjaThis study explores the monitoring of the fracture process in concrete beams and aims to characterize the evolution of damage in polyolefin fibre-reinforced concrete beams by utilizing the integrated application of two measurement techniques, digital image correlation and ultrasonic testing. The interpretation of registered wave time histories data was provided by the calculation of the magnitude-phase-composite metrics. An efficient...
-
Situational Awareness Network for the Electric Power System: the Architecture and Testing Metrics
PublikacjaThe contemporary electric power system is highly dependent on Information and Communication Technologies which results in its exposure to new types of threats, such as Advanced Persistent Threats (APT) or Distributed-Denial-of-Service (DDoS) attacks. The most exposed components are Industrial Control Systems in substations and Distributed Control Systems in power plants. Therefore, it is necessary to ensure the cyber security of...
-
The trajectories of the financial crisis of companies at risk of bankruptcy
PublikacjaThis article concerns the assessment of the trajectory of the collapse of enterprises in Central Europe. The author has developed a model of a Kohonen artificial neural network. This model was used to determine 6 different classes of risk and was allowed to graphically determine the 5- to 10-year trajectory of going bankrupt. The study used data on 140 companies listed on the Warsaw Stock Exchange. This population was divided into...
-
Behavior of residual current devices at earth fault currents with DC component
PublikacjaLow-voltage electrical installations are increasingly saturated with power electronic converters. Due to very high popularity of photovoltaic (PV) installations and the spread of electric vehicles (EV) as well as their charging installations, DC–AC and AC–DC converters are often found in power systems. The transformerless coupling of AC and DC systems via power electronic converters means that an electrical installation containing...
-
Measurements of Thermal Conductivity of LWC Cement Composites Using Simplified Laboratory Scale Method
PublikacjaThe implementation of low-energy construction includes aspects related to technological and material research regarding thermal insulation. New solutions are sought, firstly, to reduce heat losses and, secondly, to improve the environment conditions in isolated rooms. The effective heat resistance of insulating materials is inversely proportional to temperature and humidity. Cement composites filled with lightweight artificial...
-
An Empirical Study on the Impact of Gender on Mobile Applications Usability
PublikacjaIn the area of broadband wireless Internet, mobile applications have already replaced their desktop equivalents and are recognized as valuable tools for any size of businesses and for private use. With the emergence of millions of apps, the quality of their interaction with the user remains an open question for software vendors. While female and male requirements and preferences are not always similar, to the best of our knowledge,...