Wyniki wyszukiwania dla: plate
-
Linear impedance of Bi2VO5.5 glass-ceramic measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe linear electrical properties of Bi2VO5.5 glass-ceramic prepared by traditional melt quenching technique was measured by impedance spectroscopy method.
-
Thermo-resonance analysis of an excited graphene sheet using a new approach
PublikacjaForced vibration of graphene nanoplate based on a refined plate theory in conjunction with higher-order nonlocal strain gradient theory in the thermal environment has been investigated. Regarding the higher-order nonlocal strain gradient theory, both stress nonlocality and size-dependent effects are taken into account, so the equilibrium equations which are governing on the graphene sheet have been formulated by the theory....
-
3D Monitoring - Identification of measurement problems at larger movements of the tracked points
PublikacjaAuthors identified the problems associated with the determination of the controlled points coordinates by use of automated Total Station placed behind transparent barrier. Important thing in the mentioned analysis was a large change of controlled points position and not stable Total Station’s stand (because of stand’s thermal drift). This two elements, combined with measurement made through glass plate determine the need for impact...
-
Analiza porównawcza metod obliczania przebicia
PublikacjaW artykule przedstawiono analizę porównawczą wybranych normowych metod wyznaczania nośności na przebicie konstrukcji płytowo-słupowej. Przeanalizowano trzy normowe sposoby wyznaczania nośności na przebicie.Wykonane obliczenia pozwoliły na wskazanie różnic w wyznaczonych wartościach nośności płyty na przebicie w konstrukcji płytowo-słupowej.
-
Effect of C-1748 derivatives on the biofilm formation of C. albicans ATCC 10231 cells
Dane BadawczeThe datasets contain the results of the impact of five C-1748 derivatives (IKE28 - IKE32) on the biofilm formation of Candida albicans strain ATCC 10231 cells. Photographic documentation prepared with the TECAN Spark 10M titration plate reader.
-
Effect of C-1748 derivatives on the morphological transformation of C. albicans ATCC 10231 cells
Dane BadawczeThe datasets contain the results of the impact of five C-1748 derivatives (IKE28 - IKE32) on morphological transformation of Candida albicans strain ATCC 10231 cells. Photographic documentation prepared with the TECAN Spark 10M titration plate reader.
-
The morphology of vanadate glasses containing BaTiO3
Dane BadawczeThe morphology of vanadate glasses doped with BaTiO3 was measured. Samples of the composition of x[BaO,TiO2]–(80 − x)V2O5–20Bi2O3 where x = 5, 10 and 15 in mol% were prepared by a conventional melt quenching technique. The melting was performed in alumina crucibles at the temperature of 1273 K–1373 K. The melts were poured on a preheated (573 K) brass...
-
The morphology of lead-borate glasses and nanocomposites doped with iron oxide
Dane BadawczeThe topography of iron-doped borate glasses and glass-ceramics were studied. Samples of composition of xFe2O3–(100 − x)(B2O3–2PbO) (2.5 < x < 37 in mol%) were prepared by the conventional meltquenching technique. The melting was conducted in alumina crucibles at the temperature of 1523 K. The melts were poured on a preheated (573 K) brass plate...
-
The topography of Bi2VO5.5 ceramics prepared by melt-quenching technique was measured with confocal microscope
Dane BadawczeThe topography of Bi2VO5.5 ceramics prepared by melt-quenching technique was measured by confocal microscope.
-
The structure of lead-borate glasses containing nanocrystallites of iron oxides
Dane BadawczeThe structure of iron-doped glasses and glass-ceramics were studied. Glass samples of composition of xFe2O3–(100 − x)(B2O3–2PbO) (2.5 b x b 37, in mol%) were prepared by the conventional melt quenching technique. The melting was conducted in alumina crucibles at the temperature of 1523 K. The melts were poured on a preheated (573 K) brass plate and...
-
Linear impedance of strontium–borate glass measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe linear electrcial properties of strontium–borate glass was measured by impedance spectroscopy method.
-
Linear impedance of Bi2VO5.5 glass-ceramic annealed at 423 K measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe linear electrical properties of Bi2VO5.5 glass-ceramic annealed at 423 K prepared by traditional melt quenching technique was measured by impedance spectroscopy method.
-
Effect of novel bisacridines (IKE16, IKE18, IKE19, IKE21) and IE10 on the biofilm formation of C. albicans ATCC 10231 cells
Dane BadawczeThe datasets contain the results of the impact of novel bisacridines (IKE16, IKE18, IKE19, IKE21) and IE10 on the biofilm formation of Candida albicans strain ATCC 10231 cells. Photographic documentation prepared with the TECAN Spark 10M titration plate reader.
-
Analysis of ship's magnetic field with consideration of inner ferromagnetic devices
PublikacjaThis paper presents computer simulations of ship’s magnetic signatures. The influence of ship’s inner ferromagnetic devices on the signature was presented. The magnetic fields of the ship’s model were calculated in Opera 3D 18R2. The model was built from thin plates. The new, thin plate boundary condition was introduced on all ship’s surfaces.
-
Electroelastic biaxial compression of nanoplates considering piezoelectric effects
PublikacjaIn the present theoretical work, it is assumed that a piezoelectric nanoplate is connected to the voltage meter which voltages have resulted from deformation of the plate due to in-plane compressive forces whether they are critical buckling loads or arbitrary forces. In order to derive governing equations, a simplified four-variable shear deformation plate theory has been employed using Hamilton’s principle and Von-Kármán...
-
A Comparative Study on Methods of Distinction Between Near- and Far-Side Defects as Techniques Used Alongside with the Magnetic Flux Leakage Testing
PublikacjaResults of the finite element analysis show that a far-side defect in a steel plate, with the depth greater by 10% of the plate thickness than a near-side defect, can produce a very similar magnetic flux leakage (MFL) signal. Due to the fact that a measurement of MFL itself can lead to misclassification of a far-side defect as a near-side one, and thus to underestimation of its depth, a comparative study of three complementary...
-
Nonlocal three-dimensional theory of elasticity for buckling behavior of functionally graded porous nanoplates using volume integrals
PublikacjaIn this paper, the buckling of rectangular functionally graded (FG) porous nanoplates based on threedimensional elasticity is investigated. Since, similar researches have been done in two-dimensional analyses in which only large deflections with constant thickness were studied by using various plate theories; therefore, discussion of large deformations and change in thickness of plates after deflection in this study is examined....
-
Analiza nieliniowa powłok z materiałów gradientowych w ośrodku mikropolarnym
PublikacjaW pracy zaprezentowano analizę powłok z materiałów gradientowych dla zakresu dużych przemieszczeń. Macierz konstytutywna została wyprowadzona dla elementu powłokowego o 6 stopniach swobody w węźle w teorii ośrodka mikropolarnego. Zaprezentowano wyniki numeryczne dla swobodnie podpartej kwadratowej płyty FGM i porównano je z wynikami z literatury oraz uzyskanymi w programie Abaqus.
-
The structure of vanadate glass-ceramics containing BaTiO3 measured with X-ray diffraction method
Dane BadawczeThe structure of vanadate glass-ceramics doped with BaTiO3 was measured by XRD. Samples of the composition of x[BaO,TiO2]–(80 − x)V2O5–20Bi2O3 where x = 5, 10 and 15 in mol% were prepared by a conventional melt quenching technique. The melting was performed in alumina crucibles at the temperature of 1273 K–1373 K. The melts were poured on a preheated...
-
Propagation in rectangular waveguides with a pseudochiral Ω slab
PublikacjaThe transfer matrix approach is applied for analysis of waveguides loaded with a uniaxial pseudochiral Ω slab. In particular a pseudochiral parallel plate and rectangular guides are investigated. Based on the numerical analysis the influence of the pseudochirality on propagation characteristics and field distribution are examined. Other feature such as a field displacement phenomenon appearing in the both considered structures...
-
Monitoring of concrete curing in extradosed bridge supported by numerical simulation
PublikacjaThe paper describes a mathematical model of concrete curing taking into account kinetics of setting reactions. The numerical model is implemented in the author’s program that was used to monitor thermal effects recorded in the concrete bottom plate of the extradosed bridge. Numerical approach was verified by experimental measurements and used for assessment of the current compressive strength due to degree of hydration of fresh...
-
Experimental study on single phase operation of microjet augmented heat exchanger with enhanced heat transfer surface
PublikacjaThe article presents experimental investigations on a prototype heat exchanger. Presented research is focused on combined active and passive enhancement techniques of surface modification and microjet impingement. The results were compared to reference plate heat exchanger without microjet impingement. The Wilson plot method was applied to determine the heat transfer coefficients in the single phase operation. The heat exchanger...
-
Highly porous nanoberyllium for X-ray beam speckle suppression
PublikacjaThe speckle suppressor device containing highly porous nanoberyllium is proposed for manipulating with the spatial coherence length and removing undesirable speckle structure during the imaging experiments. We report a special device called the speckle suppressor, which contains the highly porous nanoberyllium plate, compacted from both sides by two beryllium windows. By insertion the speckle suppressor in the X-ray beam it allows...
-
EHD Flow Measured by 2D PIV in a Narrow Electrostatic Precipitator with Longitudinally-to-flow Wire Electrode
PublikacjaIn this paper, results of the electrohydrodynamic (EHD) flow patterns in two narrow ESPs with longitudinally-to-flow wire electrode are presented. The influence of the ESP geometry on the EHD flow generated in the ESP was investigated. The results obtained from 2 dimensional (2D) Particle Image Velocimetry (PIV) showed similarities and differences of the particle flow in the wire-plate and wire-cylinder type ESP.
-
EHD Flow Measured by 2D PIV in a Narrow Electrostatic Precipitator with Longitudinal Wire Electrode
PublikacjaIn this paper, results of the electrohydrodynamic (EHD) flow patterns in two narrow ESPs with longitudinally-to-flow wire electrode arepresented. The influence of the ESP geometry on the EHD flow generated in the ESP was investigated. The results obtained from 2-dimensional(2D) Particle Image Velocimetry (PIV) showed similarities and differences of the particle flow in the wire-plate and wire-cylinder type ESP.
-
Linear impedance of vanadate glasses containing BaTiO3
Dane BadawczeThe linear impedance of vanadate glasses doped with BaTiO3 was measured. Samples of the composition of x[BaO,TiO2]–(80 − x)V2O5–20Bi2O3 where x = 5, 10 and 15 in mol% were prepared by a conventional melt quenching technique. The melting was performed in alumina crucibles at the temperature of 1273 K–1373 K. The melts were poured on a preheated (573...
-
The morphology of vanadate glass-ceramics containing BaTiO3
Dane BadawczeThe morphology of vanadate glass-ceramic doped with BaTiO3 was measured. Samples of the composition of x[BaO,TiO2]–(80 − x)V2O5–20Bi2O3 where x = 5, 10 and 15 in mol% were prepared by a conventional melt quenching technique. The melting was performed in alumina crucibles at the temperature of 1273 K–1373 K. The melts were poured on a preheated (573...
-
Topography of barium-vanadate glasses
Dane BadawczeThe topography of barium-vanadate glasses was measured. Samples of the composition of xBaO-(100-x)V2O5 where x= 30, 40 and 45 (in %mol) were prepared by the conventional melt quenching technique. Appropriate amounts of reagents: BaO (≥99.9%, P.P.H STANLAB Sp.J.) and V2O5 (≥99.9%, POCH) were thoroughly mixed in an agate mortar. The melting was performed...
-
Effect of power frequency on the stress state of disc actuator
PublikacjaThis paper presents the concept of determining the optimum frequency of coil supply in inductive-dynamic drive. As a criterion to obtain the sought frequency, the smallest value of reduced stress in the disc was assumed while maintaining the desired dynamics. The disc stress is determined on the basis of solution of vibrating thin plate equation. Magnetic pressure acting on the disc is obtained from a hybrid circumferentially-field...
-
Linear impedance of strontium–borate glass measured with impedance spectroscopy method at high temperature region
Dane BadawczeThe linear electrcial properties of strontium–borate glass was measured by impedance spectroscopy method.
-
Flow distribution and heat transfer in minigap and minichannel heat exchangers during flow boiling
PublikacjaThe topic of boiling heat transfer in miniscale geometries has focused the ever increasing interest of researchers in recent years. However, most of the works are related to mini- and microchannels and much less to minigaps. Meanwhile, minigaps allow for more comprehensive experimental studies, i.e. flow visualisations due to the flat, two-dimensional configuration of the flow. The results of the experimental investigations of...
-
Symulacje przepływu ciepła przez płytę betonową
PublikacjaW pracy przedstawiono symulacje numeryczne dojrzewania betonu w płycie górnej skrzynki czteroprzęsłowego mostu typu extradosed. Model matematyczny opisujący przepływ ciepła dedykowany jest do prognozowania dojrzałości i wytrzymałości twardniejącego betonu. Proponowany model zaimplementowano w autorskim programie numerycznym napisanym w środowisku Matlab. Podejście numeryczne zweryfikowano za pomocą danych doświadczalnych uzyskanych...
-
A study on transverse shear correction for laminated sandwich panels
PublikacjaThe paper presents a study on an application of the First Order Shear Deformation Theory in a linear static analysis of elastic sandwich panels. A special attention has been given to the issue of the transverse shear correction. Two benchmark examples of sandwich plate problems with known reference solutions have been selected for a comparative analysis performed with own Finite Element codes. Interesting results allowed for drawing...
-
A gap waveguide-based mechanically reconfigurable phase shifter for high-power Ku-band applications
PublikacjaThis paper presents a novel design of a low-loss, reconfgurable broadband phase shifter based on groove gap waveguide (GGW) technology. The proposed phase shifter consists of a folded GGW and three bends with a few pins forming the GGW and one bend attached to a movable plate. This movable plate allows for adjustments to the folded waveguide length, consequently altering the phase of electromagnetic waves. The advantage of GGW...
-
Edge-Guided Mode Performance and Applications in Nonreciprocal Millimeter-Wave Gyroelectric Components
PublikacjaThe analogies between the behavior of gyromagnetic and gyroelectric nonreciprocal structures, the use of the simple transfer matrix approach, and the edge-guided (EG) wave property, supported in a parallel plate model for integrated magnetized semiconductor waveguide, are investigated in those frequency regions, where the effective permittivity is negative or positive. As with their ferrite counterparts, the leakage of the EG waves...
-
The bridge over Regalia River in Szczecin - design and construction.
PublikacjaNowoclowa Route is the largest projekt in Szczecin, that consists of 11 km of roads 3,3 km bridges and viaducts, including three parallel bridges across Regalica River (the east arm of Odra River), 535 m long, with the spans: 59+90+90+116+116+64m. The bridge structure consist of two steel plate girders composite with reinforced concrete deck slab. The design and the construction of the bridge are described in the paper.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022674311]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022677291]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022671911]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022679361]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022672001]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022671121]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022682591]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022678341]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022672521]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022677921]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022685121]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022672211]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022672721]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma in situ - Female, 44 - Tissue image [11300630022673001]
Dane BadawczeThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.