Wyniki wyszukiwania dla: HEAT SHOCK
-
Phosphorylation‐mediated regulation of heat shock response in Escherichia coli
PublikacjaEscherichia coli has two heat shock regulons under the transcriptional control of Esigma(32) and Esigma(E) RNA polymerases. These polymerases control the expression of genes, the products of which are needed for correct folding of proteins in the cytoplasm and the extracytoplasm respectively. In this study, we report that mutations in a tyrosine phosphatase-encoding gene led to decreased activity of these heat shock regulons. The...
-
Contribution of small heat shock proteins to muscle development and function
Publikacja -
Evolution towards simplicity in bacterial small heat shock protein system
PublikacjaEvolution can tinker with multi-protein machines and replace them with simpler single-protein systems performing equivalent functions in an equally efficient manner. It is unclear how, on a molecular level, such simplification can arise. With ancestral reconstruction and biochemical analysis, we have traced the evolution of bacterial small heat shock proteins (sHsp), which help to refold proteins from aggregates using either two...
-
Assembly of Lipopolysaccharide in Escherichia coli Requires the Essential LapB Heat Shock Protein
PublikacjaHere, we describe two new heat shock proteins involved in the assembly of LPS in Escherichia coli, LapA and LapB (lipopolysaccharide assembly protein A and B). lapB mutants were identified based on an increased envelope stress response. Envelope stress responsive pathways control key steps in LPS biogenesis and respond to defects in the LPS assembly. Accordingly, the LPS content in ΔlapB or Δ(lapA lapB) mutants was elevated, with...
-
Cloning and characterization of the dnaK heat shock operon of the marine bacterium Vibrio harveyi
Publikacja -
Two bacterial small heat shock proteins, IbpA and IbpB, form a functional heterodimer
PublikacjaSmall heat shock proteins (sHsps) are a conserved class of ATP-independent chaperones which in stress conditions bind to unfolded protein substrates and prevent their irreversible aggregation. Substrates trapped in sHsps-containing aggregates are efficiently refolded into native structures by ATP-dependent Hsp70 and Hsp100 chaperones. Most γ-proteobacteria possess a single sHsp (IbpA), while in a subset of Enterobacterales, as...
-
Pro-death signaling of cytoprotective heat shock factor 1: upregulation of NOXA leading to apoptosis in heat-sensitive cells
Publikacja -
The Major Heat Shock Proteins, Hsp70 and Hsp90, in 2-Methoxyestradiol-Mediated Osteosarcoma Cell Death Model
Publikacja -
Interactive effects of vanadium and phosphorus on their uptake, growth and heat shock proteins in chickpea genotypes under hydroponic conditions
Publikacja -
Fabrication of Electrochemical Biosensor Based on Titanium Dioxide Nanotubes and Silver Nanoparticles for Heat Shock Protein 70 Detection
Publikacja -
Mycobacterium tuberculosis Complex and Mycobacterial Heat Shock Proteins in Lymph Node Tissue from Patients with Pulmonary Sarcoidosis
Publikacja -
Geldanamycin-Induced Osteosarcoma Cell Death Is Associated with Hyperacetylation and Loss of Mitochondrial Pool of Heat Shock Protein 60 (Hsp60)
Publikacja -
Heat shock proteins (HSP 90, 70, 60, and 27) in Galleria mellonella (Lepidoptera) hemolymph are affected by infection with Conidiobolus coronatus (Entomophthorales)
Publikacja -
Impact of heat shock transcription factor 1 on global gene expression profiles in cells which induce either cytoprotective or pro-apoptotic response following hyperthermia
Publikacja -
The model homologue of the partially defective human 5,10-methylenetetrahydrofolate reductase, considered as a risk factor for stroke due to increased homocysteine level, can be protected and reactivated by heat shock proteins
Publikacja -
Karaś P., Kochanowicz K., Pitek M., Domański P., Obuchowski I., Tomiczek B., Liberek K.: Evolution towards simplicity in bacterial small heat shock protein system// eLife -, (2023), s.1-21
PublikacjaEvolution can tinker with multi-protein machines and replace them with simpler single-protein systems performing equivalent functions in an equally efficient manner. It is unclear how, on a molecular level, such simplification can arise. With ancestral reconstruction and biochemical analysis, we have traced the evolution of bacterial small heat shock proteins (sHsp), which help to refold proteins from aggregates using either...
-
Gracjana Klein-Raina dr hab.
Osoby -
PROBLEMS OF THE STARTING AND OPERATING OF HYDRAULIC COMPONENTS AND SYSTEMS IN LOW AMBIENT TEMPERATURE (PART V) METHODS ENSURING CORRECT START-UP OF HYDRAULIC COMPONENTS OF SHIP’S ONBOARD DEVICES IN LOW AMBIENT TEMPERATURES
PublikacjaA large number of hydraulic devices and systems are started in low ambient temperatures. A good example of such a device is the hoisting winch on the ship. Starting hydraulic drive units in thermal shock conditions (rapid supply of hot oil to the cold unit) may lead to incorrect operation of the actuating system, for instance, due to the loss of clearance between cooperating elements. The article presents methods to prevent the...
-
PROBLEMS OF THE STARTING AND OPERATING OF HYDRAULIC COMPONENTS AND SYSTEMS IN LOW AMBIENT TEMPERATURE (PART IV) MODELLING THE HEATING PROCESS AND DETERMINING THE SERVICEABILITY OF HYDRAULIC COMPONENTS DURING THE STARTING-UP IN LOW AMBIENT TEMPERATURE
PublikacjaDesigners of hydraulically driven machines and devices are obliged to ensure during design process their high service life with taking into account their operational conditions. Some of the machines may be started in low ambient temperature and even in thermal shock conditions (due to delivering hot working medium to cold components). In order to put such devices into operation appropriate investigations, including experimental...
-
Molecular identification and genotyping of Staphylococci: genus, species, strains, colnes, lineages, and interspecies exchanges
PublikacjaStaphylococci are increasingly recognized as etiological agents of many opportunistic human and animal infections, emphasizing the need for a rapid and accurate identification, even to a genotypical level of these bacteria. In the recent years, there has been a significant progress in typing and phylogenetic study of Staphylococcus species. Here, we describe molecular methods used in taxonomy as well as staphylococci characterization....
-
Molecular Strategy for Survival at a Critical High Temperature in Eschierichia coli
PublikacjaThe molecular mechanism supporting survival at a critical high temperature (CHT) in Escherichia coli was investigated. Genome-wide screening with a single-gene knockout library provided a list of genes indispensable for growth at 47°C, called thermotolerant genes. Genes for which expression was affected by exposure to CHT were identified by DNA chip analysis. Unexpectedly, the former contents did not overlap with the latter except...
-
Fatty acyl benzamido antibacterials based on inhibition of DnaK-catalyzed protein folding
PublikacjaWe have reported that the hsp70 chaperone DnaK from Escherichia coli might assist protein folding by catalyzing the cis/trans isomerization of secondary amide peptide bonds in unfolded or partially folded proteins. In this study a series of fatty acylated benzamido inhibitors of the cis/trans isomerase activity of DnaK was developed and tested for antibacterial effects in E. coli MC4100 cells. Nα-[Tetradecanoyl-(4-aminomethylbenzoyl)]-l-asparagine...
-
Funkcjonowanie zespołów napędu hydraulicznego maszyn w niskich temperaturach otoczenia
PublikacjaW pracy przedstawiono cztery warianty klasyfikacji rozruchów oziębionego napędu hydraulicznego. Pierwsza sytuacja dotyczy zagadnienia, w którym wszystkie zespoły układu napędowego wraz z olejem mają taką samą niską temperaturę podczas rozruchu. Pozostałe warianty odnoszą się do rozruchu w warunkach szoku termicznego wywołanych zasilaniem ciepłym czynnikiem roboczym oziębionych zespołów hydraulicznych. Rozruch zespołów...
-
Chemical Aspects of Biological Activity of Isothiocyanates and Indoles, the Products of Glucosinolate Decomposition
PublikacjaThere is growing evidence that cancer chemoprevention employing natural, bioactive compounds may halt or at least slow down the different stages of carcinogenesis. A particularly advantageous effect is attributed to derivatives of sulfur-organic phytochemicals, such as glucosinolates (GLs) synthesized mainly in Brassicaceae plant family. GLs are hydrolysed enzymatically to bioactive isothiocyanates (ITC) and indoles, which exhibit strong...
-
2-Methoxyestradiol and Hydrogen Peroxide as Promising Biomarkers in Parkinson’s Disease
PublikacjaEstrogens function in numerous physiological processes including controlling brain cell growth and differentiation. 2-Meth- oxestradiol (2-ME2), a 17β-estradiol (E2) metabolite, is known for its anticancer effects as observed both in vivo and in vitro. 2-ME2 affects all actively dividing cells, including neurons. The study aimed to determine whether 2-ME2 is a potentially cancer-protective or rather neurodegenerative agent in a...
-
Induced Sheath Voltages In 110 Kv Power Cables – Case Study
PublikacjaThe paper considers shock hazard due to induced sheath voltages in 110 kV power cables. Various configurations of the metallic sheaths bonding and earthing (single-point bonding, both-ends bonding, cross-bonding) are analysed. Taking into account shock hazard and ability of the system to power transfer an optimal configuration is proposed.
-
Self-refraction of acoustic pulses with shock fronts in some nonequilibrium media
PublikacjaThe nonlinear self-refraction of acoustic pulsed beams, which include shock fronts, is studied. The medium of sound propagation is a gas where thermodynamically nonequilibrium processes take place, such as exothermic chemical reaction or excitation of vibrational degrees of a molecule’s freedom. Comparative analysis of the features of sound propagation over gases where pure nonlinear attenuation of the shock wave occurs, and gases...
-
NON-STATIONARY THERMAL SELF-ACTION OF ACOUSTIC BEAMS CONTAINING SHOCK FRONTS IN THERMOCONDUCTING FLUID
PublikacjaNon-stationary thermal self-action of a periodic or impulse acoustic beam containing shock fronts in a thermoconducting Newtonian fluid is studied. Self-focusing of a saw-tooth periodic and impulse sound is considered, as well as that of a solitary shock wave which propagates with the linear sound speed. The governing equations of the beam radius are derived. Numerical simulations reveal that the thermal conductivity weakens the...
-
Induced sheath voltages in 110 kV power cables – case study
PublikacjaThis paper considers electric shock hazard due to induced sheath voltages in 110 kV power cables. The purpose of this paper is to find an optimal configuration of the power cable system, taking into account electric shock hazard and ability of the system to transfer maximal power. A computer simulations on a computer model of the local power system, comprising high voltage power cables, were carried out. This model enables to analyse...
-
LabVIEW-based intelligent system of protection against electric shock for photovoltaic installations
PublikacjaEvaluation of shock hazard in installations with photovoltaic sources of energy is more complicated than in a conventional low voltage system. In case of earth fault in photovoltaic generators, that are connected to the AC power public grid, a composite waveform of earth fault current in the installation may occur. For composite waveforms, the safety criteria should be modified. The paper considers the effect of the composite waveforms...
-
Numerical Methods
Kursy OnlineNumerical Methods: for Electronics and Telecommunications students, Master's level, semester 1 Instructor: Michał Rewieński, Piotr Sypek Course description: This course provides an introduction to computational techniques for the simulation and modeling of a broad range of engineering and physical systems. Concepts and methods discussed are widely illustrated by various applications including modeling of integrated circuits,...
-
Analysis of the Heating Process of Hydraulic Motors during Start-Up in Thermal Shock Conditions
PublikacjaConditions that prevail during harsh winters and hot summers pose a serious challenge for machine designers building devices suitable for operation in extreme weather. It is essential for the designers and the users to define the principles and conditions for the safe operation of machines and devices with hydraulic drive in low ambient temperatures. Bearing in mind the above, the author tested the hydraulic motors in thermal shock...
-
Thermal Self-Action of Acoustic Beams Containing Several Shock Fronts
PublikacjaThermal self-action of an acoustic beam with one discontinuity or several shock fronts is studied in a Newtonian fluid. The stationary self-action of a single sawtooth wave with discontinuity (or some integer number of these waves), symmetric or asymmetric, is considered in the cases of self-focusing and self- defocusing media. The results are compared with the non-stationary thermal self-action of the periodic sound. Thermal self-action...
-
An asymmetrical λ-foot of condensing steam flow in the IMP PAN nozzle
PublikacjaIn the present paper we have focused on the precise prediction of the spontaneous condensation phenomena in wet steam flow. Novelty of our approach lies on modelling both the moment of initiation of a phase transition, as well as the moment of its reverse progress - called here re-vaporization of the condensate phase. The practical issue is to elaborate of a model of spontaneous condensation/vaporization of water steam flow...
-
Influence of type of material on performance of hydraulic components in thermal shock conditions
PublikacjaDuring the start-up of a hydraulic system in low ambient temperatures an incorrect operation may occur. The principles and conditions of safely operating hydraulic driven machines and devices are essential to designers and operators. For this reason the author of this article has conducted a series of tests on hydraulic components and systems in thermal shock conditions (cooled-down components were supplied with hot working medium)....
-
Electrical safety in low-voltage DC microgrids with B-type residual current devices
PublikacjaResidual current devices (RCDs) are most popular devices used in low-voltage installations for protection against electric shock and fire. In cases of high risk of electric shock the application of RCDs is mandatory. Currently, the spread of local direct current (DC) microgrids is widely considered. This creates new challenges for protective systems, in particular those based on RCDs. The main purpose of the research is to test...
-
A method to monitor urinary carbon dioxide in patients with septic shock
PublikacjaSevere sepsis and septic shock are life-threatening conditions with mortality rates exceeding 31% (Levy et al., 2012) [1]. Septicemia was the most expensive US hospital condition in 2011 (Torio and Andrews, 2006)[2]. Urinary carbon dioxide may provide rapid, clinically useful information about a patient’s status, empowering physicians to intervene earlier and improve septic shock mortality. The objective of this paper is to validate...
-
Expert opinion on the effectiveness of protection against electric shock in case of fault in an installation for electric vehicles charging
PublikacjaThe opinion concerns the use of residual current devices for protection against electric shock by automatic disconnection of supply in a Norwegian installation intended for charging of electric vehicles.
-
Noise related to gas bottles explosions
PublikacjaModern industrialized world is in a never ending danger of accidents and catastrophes of technical nature. Some of them may involve fires and explosions of gas storage bottles or containers. Technical University of Gdansk, Poland performed numerous tests where bottles containing acetylene, oxygen, hydrogen, CO2, LPG, LNG or CNG were blown due to excessive temperature caused by fire. Although those experiments were not focused on...
-
Agnieszka Potęga dr inż.
Osoby -
Compressible gas density measurement by means of Fourier analysis of interferograms
PublikacjaThis paper describes a method for nonintrusive compressible gas density measurement by means of automated analysis of interferograms using FFT (Fast Fourier Transform), and its implementation using DFT (Discrete Fourier Transform), that does make this measurement technique a fairly valuable and accessible experimental method. The presented approach makes it possible to use the finite fringe setting of the interferometer, thus reducing...
-
The risk assessment of adverse events of nursing activities as the element of quality management in healhcare
PublikacjaThe purpose of the paper is to present MedCARVER+Shock method and Pareto analysis and its usability for the risk assessment of adverse events of nursing activities. 888 activities carried out by all 190 nurses working at the District Hospital X located in Poland were taken into account. During the research the qualitative approach was used. As the result sixteen groups of nursing activities causing the highest risk of adverse events...
-
ENHANCED EVAPORATION OF THE DROPLETS OF CONDENSATE IN THE ASYMMETRICAL SHOCK WAVE ZONE
PublikacjaIn the low-pressure part of steam turbine, the state path usually crosses the saturation line in penultimate stages [4,5]. The formation and evolution of these droplets lower the performance of the wet stages of the turbines, and their effects on the efficiency are collectively known as wetness losses [4]. Nowadays, due to work of steam turbines at partial load, process of homogeneous and heterogeneous condensation still is current....
-
Experimental verification of a new method of loop resistance testing in low voltage systems with residual current devices
PublikacjaA periodical verification of the effectiveness of protection against electric shock shall be performed in low voltage systems. The scope of this verification includes loop impedance/resistance testing. If a residual current device is installed in a tested circuit, this testing is problematic. A residual current device trips out during the test, because of the high value of measurement current. This precludes the execution of the...
-
Computer-Aided Calculations of Earth Potential Rise in High Voltage Overhead Lines
PublikacjaHigh voltage overhead power lines with earth wires comprise towers made of conductive material. Some towers are in locations where people can be expected to be either for a long time or for a short time but very frequently. Evaluation of shock hazard near such towers requires calculation of line-to-earth short-circuit current, earth current and especially earth potential rise. Number of towers in high voltage power lines can exceed...
-
RCDs Tripping in the Range from DC to AC 50 kHz for Slowly Rising Residual Current
PublikacjaThe wide use of power electronic converters means that in many low-voltage systems earth fault currents containing components from DC to AC of various frequencies have to be taken into account. Due to the tendency to increase the modulation frequency in converters, components of higher frequencies may be in the order of several tens of kilohertz. Therefore, it is very important to verify the behavior of devices for protection against...
-
Sounding rocket temperature and heat transfer data
Dane BadawczeThis dataset contains temperature and heat transfer data measured during REXUS 25 sounding rocket HEDGEHOG Experiment launched from Esrange Space Centre, Kiruna, Sweden. For experiment details, please see:
-
Numerical Simulations for Transonic Flow in Control Valve
PublikacjaResults of numerical simulations for transonic flow in control valve are presented. The valve is the main part of an adaptive pneumatic shock absorber. Flow structure in the valve domain and the influence of the flow non-uniformity in the valve on a mass flow rate is investigated. Numerical simulation results are compared with experimental data.
-
A new method of fault loop resistance measurement in low voltage systems with residual current devices
PublikacjaThis paper presents a new method of fault loop resistance measurement in low voltage systems with residual current devices. The method enables measuring fault loop resistance without nuisance tripping of residual current devices, by application an unconventional waveform of measurement current. It is important for proper verification of the effectiveness of protection against electric shock.
-
Volumetric and torque efficiency of pumps during start-up in low ambient temperatures
PublikacjaThe volumetric, torque and total efficiency of hydraulic pumps change during start-up in low ambient temperatures, as well as in thermal shock conditions, un-til they reach the set conditions. The time to reach steady-state conditions de-pends on many parameters: ambient temperature, flow rate, fluid temperature, design of hydraulic units. The author carried out tests of hydraulic pumps in the Hydraulics Laboratory of the Faculty...
-
Thermal self-action effects for acoustic beams containing fronts in a Maxwell relaxing fluid
PublikacjaThis paper examines the thermal self-action of acoustic beams in a Maxwell relaxing fluid. This type of thermal self-action differs from that in a Newtonian fluid and behaves differently depending on a ratio of sound period and time of thermodynamic relaxation. The self-action which relates to sound beams containing shock fronts is also discussed. In addition, stationary and non-stationary types of self-action are considered.
-
Calculation of Induced Sheath Voltages in Power Cables – Single Circuit System versus Double Circuit System
PublikacjaThis paper presents comparison of values of induced sheath voltages in power cable metallic sheaths when one or two cables per phase are used. Calculation of voltages is performed for various phase sequences of the power cables. Three types of the sheaths bonding and earthing are considered. Shock hazard and voltage stress of non-metallic outer sheath of cables are evaluated. The proposed, optimal configuration of the power cable...
-
Behavior of residual current devices at frequencies up to 50 kHz
PublikacjaThe use of residual current devices (RCDs) is obligatory in many types of low-voltage circuits. They are devices that ensure protection against electric shock in the case of indirect contact and may ensure additional protection in the case of direct contact. For the latter purpose of protection, only RCDs of a rated residual operating current not exceeding 30 mA are suitable. Unfortunately, modem current-using equipment supplied...
-
Testing sensitivity of A-type residual current devices to earth fault currents with harmonics
PublikacjaIn many applications, modern current-using equipment utilizes power electronic converters to control the consumed power and to adjust the motor speed. Such equipment is used both in industrial and domestic installations. A characteristic feature of the converters is producing distorted earth fault currents, which contain a wide spectrum of harmonics, including high-order harmonics. Nowadays, protection against electric shock in...
-
Computer-aided Analysis of Induced Sheath Voltages in High Voltage Power Cable System
PublikacjaThis paper concerns the effect of configuration of high voltage power cables on induced voltages in their metallic sheaths. One, two or three cables per phase and phase sequence of the cables are considered. Computing of the voltages was performed for a normal operation and in case of earth fault. Various ways of the sheaths bonding are considered as well. Shock hazard and voltage stress of non-metallic outer sheath of cables are...
-
XRD-TiO2 heat-treated at 400-600oC in Ar or H2
Dane BadawczeThese data contain XRD patterns of TiO2 heat-treated at 400-600oC in Ar or H2. Two pases of TiO2 were identified: anatase and rutile.
-
The topography of as-quenched and heat treated 58(2Bi2O3-V2O5)-42SrB4O7 glasses measured with confocal microscope
Dane BadawczeThe topography of as-quenched and heat treated 58(2Bi2O3-V2O5)-42SrB4O7 glasses measured with confocal microscope.
-
Metrological analysis of an computerized system of protection against electric shock in circuits with variable speed drives
PublikacjaDrive systems, that can be operated at variable speed, are equipped with power electronics converters. This causes distortion of the earth current, and consequently the need to take into account the use of proper protective devices in relation to earth current harmonics. This paper presents a system for protection against electric shock in circuits with power electronics converters and metrological analysis indicating the requirements...
-
Thermal Self-Action Effects of Acoustic Beam in a Gas with Reversible or Irreversible Chemical Reaction
PublikacjaThermal self-action of acoustic beam in a gas where an exothermic chemical reaction takes place, is studied. This kind of thermal self-action differs from that in a newtonian fluid. In dependence on the type of a chemical reaction, reversible or not, heating or cooling of a medium occurs. A beam in the case of the irreversible reaction may be unusually self-focusing. The self-action effects relating to wave beams containing shock...
-
Analytical and reliability data from the real-time simulator biogas plant
Dane BadawczeThe dataset represents the results of biogas plant simulation. The described plant is an agricultural biogas system, which can produce electrical energy with power estimated up to 1070 kW and heat energy that can reach 1200 kW simultaneously.
-
The morphology of as-quenched and heat treated 58(2Bi2O3-V2O5)-42SrB4O7 glasses measured with AFM
Dane BadawczeThe morphology of as-quenched and heat treated 58(2Bi2O3-V2O5)-42SrB4O7 glasses was measured with the use of atomic force microscope.
-
Cavity-expansion approximation for projectile impact and penetration into sand
PublikacjaA one-dimensional problem of a spherical cavity expanding at a constant velocity from zero initial radius in an infinite granular medium, which has the first-kind self-similar solution, is considered. We are solving this dynamic spherical cavity-expansion problem to model rigid spheres penetrating into a granular media. Elastic–plastic deformation of the granular media is described in a barotropic approximation, using the high-pressure...
-
RESEARCH OF HYDRAULIC PISTON PUMPS’ START-UP IN LOW AMBIENT TEMPERATURES
PublikacjaStarting hydraulic pumps in low ambient temperatures may cause: decreased hydraulic-mechanical efficiency, larger vibration of hydraulic installation, faster wear and more frequent damage to the elements of pumps, change of material properties of elements, increase of pressure drop. As a result of increase of resistance of cold oil flow in the suction pipe, large underpressure may be experienced, causing incomplete filling of pump...
-
EPR of TiO2 hydrogenated at 500 and 600oC
Dane BadawczeData contain EPR spectra of TiO2 (anatase phase) heat treated in H2 at 500 and 600oC. Sample heated at 500oC contained 4 wt% of rutile and that at 600oC 8 wt% of rutile.
-
XPS-TiO2 heated in H2
Dane BadawczeThese XPS spectra were recorded for TiO2 heat-treated at 450-600oC in H2. Surface oxygen groups were determined. Deconvolution of Ti 2p peak allowed to determine Ti3+ on the titania surface.
-
SEM of TiO2 heated at 400-600oC in Ar or H2
Dane BadawczeData contain some SEM images of TiO2 taken after its heat treatment in Ar or H2 at 400-600oC. Treated TiO2 was crystalline anatase phase with 3-4 % of rutile nclei.
-
System of protection against electric shock for circuits with power electronics converters
PublikacjaModern low voltage circuits are very often equipped with power electronics converters, therefore in these circuits non-sinusoidal earth currents (touch currents) may occur. For non-sinusoidal currents safety criteria should be modified. This paper presents these modified criteria and a computer system of protection against electric shock which can be implemented in circuits with power electronics converters. The system is based...
-
Results of implementation of Feed Forward Neural Networks for modeling of heat transfer coefficient during flow condensation for low and high values of saturation temperature
Dane BadawczeThis database present results of implementation of Feed Forward Neural Networks for modeling of heat transfer coefficient during flow condensation for low and high values of saturation temperature. Databse contain one table and 7 figures.
-
FTIR-TiO2 heated at 400-600oC in Ar or H2
Dane BadawczeData contain FTIR diffuse eflectance spectra of TiO2, which was heat-treated at 400-600oC in Ar or H2. Hydrogen reduced TiO2 revealed new bands due to the adsorption of some species on the titania oxygen vacancy sites.
-
Modification of the operating point of residual current transformers for high frequency earth fault currents detection
PublikacjaFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when earth fault current with high frequency components occurs. Serious hazard of electrocution exists then. One of the most important element of residual current devices is a residual current transformer with iron core. Tripping characteristic of residual current devices strictly...
-
The structure of vanadate glass-ceramics containing BaTiO3 measured with X-ray diffraction method
Dane BadawczeThe structure of vanadate glass-ceramics doped with BaTiO3 was measured by XRD. Samples of the composition of x[BaO,TiO2]–(80 − x)V2O5–20Bi2O3 where x = 5, 10 and 15 in mol% were prepared by a conventional melt quenching technique. The melting was performed in alumina crucibles at the temperature of 1273 K–1373 K. The melts were poured on a preheated...
-
Thermal self-action effects of acoustic beam in a vibrationally relaxing gas
PublikacjaThermal self-action of acoustic beam in a molecular gas with excited internal degrees of molecules’ freedom, is studied. This kind of thermal self-action differs from that in a Newtonian fluid. Heating or cooling of a medium takes place due to transfer of internal vibrational energy. Equilibrium and non-equilibrium gases, which may be acoustically active, are considered. A beam in an acoustically active gas is self-focusing unlike...
-
Improving sensitivity of residual current transformers to high frequency earth fault currents
PublikacjaFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when high frequency earth fault current occurs. Serious hazard of electrocution exists then. In order to detect such a current, it is necessary to modify parameters of residual current devices, especially the operating point of their current transformer. The authors proposed...
-
Residual current devices in electric vehicles charging installations
PublikacjaThe main requirements of national regulations and international standards regarding protection against electric shock in electric vehicle charging installations are presented. The principles of using residual current devices (RCDs) in such installations are discussed. It is pointed out that RCDs are mandatory equipment for safe charging of electric vehicles. It is noted that the standards require the use of RCDs having an appropriate...
-
Photoluminescence spectra of TiO2
Dane BadawczeThese data contain photoluminescence spectra of TiO2 measured at the temperature of liquid nitrogen. There is a comparison of the photoluminescence spectra of TiO2 heat treated at 400-600oC in the ambient (Ar) and reduced (H2) atmospheres. These emission spectra were recorded after TiO2 excitation with a wavelength of 290 nm
-
The structure of strontium–borate glasses and glass-ceramics containing bismuth and vanadium oxides measured with X-ray diffraction method
Dane BadawczeThe structure of strontium–borate glasses and glass-ceramics containing bismuth and vanadium oxides was measured by XRD.
-
Energy Security of Polish Consumers in 2004-2021
Dane BadawczeEnergy security is one of the most important components of economic security. It is influenced not only by access to energy sources and the economic situation of the state and the individual consumer. In the years 2004–2021, energy security of the individual consumer in the economic dimension significantly improved. This was due to several factors:1....
-
TG-hydroxyl groups in TiO2-P25
Dane BadawczeTG analyses were performed for powdered TiO2 - commercial P25 sample, which was heat-treated from room temperature to 500 C in the nitrogen atmosphere. Mass loss at lower temperature such as 120 C was related to the physisorbed water, and that one occurring at 500 C to the chemisorbed hydroxyl groups.
-
Transient States during Short-circuit in a Line Powered by UPS and its Impact on Earth Fault Loop Impedance Measurement and Power Quality
PublikacjaThe short-circuit in a line powered by Uninterruptible Power Supply (UPS) during different UPS operation modes is presented in the article. The transient state condition related to the short-circuit in a line fed from double conversion On-line UPS is discussed in detail. The results of the measurements of earth fault loop impedance (FLI) in circuits powered by UPS with the instruments of various manufacturers are presented. The...
-
SEM/EDX data of (Cr,Fe,Mn,Co,Ni)3O4 High-entropy spinel oxide thin films deposited on amorphous SiO2 substrate by spray pyrolysis techniqe
Dane BadawczeThis Data set include SEM and EDX results of (Mn,Co,Fe,Ni,Cr)3O4 high-entropy spinel oxide prepared in the form of a ~ 500 nm thin film utilising a facile spray pyrolysis technique. The structural and electrical properties of the layers were characterised after exposure to temperatures in the range of 400–900 ◦C. The as-deposited layers were amorphous,...
-
TEM data of (Cr,Fe,Mn,Co,Ni)3O4 High-entropy spinel oxide thin films deposited on amorphous SiO2 substrate by spray pyrolysis techniqe
Dane BadawczeThis Dataset include presentation of summarized TEM investigation of (Mn,Co,Fe,Ni,Cr)3O4 high-entropy spinel oxide prepared in the form of a ~ 500 nm thin film utilising a facile spray pyrolysis technique. The structural and electrical properties of the layers were characterised after exposure to temperatures in the range of 400–900 ◦C. The as-deposited...
-
Measurements of the heat of hydration released by concrete specimens cured under adiabatic conditions
Dane BadawczeThe DataSet contains measurements of heat of hydartion of concrete cubes (150 x 150 x 150 mm) cured under adiabatic conditions. The specimens were moulded from six types of concrete mixtures produced in the laboratory conditions. Mix #1: Portland cement CEM I 42.5R and gravel aggregate, mix #2: CEM I 42.5R and basalt aggregate, mix#3: Portland-composite...
-
Regulated assembly of lipopolysaccharide and sensing of its alterations in Escherichia coli
PublikacjaThis thesis describes mechanism of the regulation of the transcription of the rpoE gene encoding an essential RNA polymerase subunit in Escherichia coli. The RpoE regulates extracytoplasmic stress response regulon and is required to initiate transcription of genes, whose products are involvedin the folding of periplasmic proteins and synthesis and transport of outer membrane components. The transcriptional regulation of the rpoE...
-
Impact of configuration of earth continuity conductor on induced sheath voltages in power cables
PublikacjaIn high voltage power cable systems a problem of induced sheath voltages exist. Due to these voltages electric shock and damage of non-metallic outer sheath of the cables may occur. Exposure to voltage of the outer sheath may be very high in case of earth fault with high value of earth current. In order to reduce induced sheath voltages an earth continuity conductor (conductors) along power cables is applied. Configuration of this...
-
Testing an evaporator operation with a concave manifold, condenser temperature 30, evaporator temperature 70 and preheater temperature 60
Dane BadawczeThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a bifurcation manifold, condenser temperature 20 and evaporator temperature 85
Dane BadawczeThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a concave manifold, condenser temperature 30, evaporator temperature 70 and preheater temperature 40
Dane BadawczeThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a trapezoidal manifold, condenser temperature 90 and evaporator temperature 90
Dane BadawczeThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a bifurcation manifold, condenser temperature 20 and evaporator temperature 70
Dane BadawczeThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a rectangular manifold, condenser temperature 30 and evaporator temperature 90
Dane BadawczeThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a trapezoidal manifold, condenser temperature 70 and evaporator temperature 60
Dane BadawczeThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a bifurcation manifold, condenser temperature 20 and evaporator temperature 95
Dane BadawczeThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a bifurcation manifold, condenser temperature 20 and evaporator temperature 90
Dane BadawczeThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
The topography of as-quenched and heat treated 50(2Bi2O3-V2O5)-50SrB4O7 and 50Bi2VO5.5-50SrB4O7 glasses measured with confocal microscope
Dane BadawczeThe topography of as-quenched and heat treated 50(2Bi2O3-V2O5)-50SrB4O7 and 50Bi2VO5.5-50SrB4O7 glasses measured with confocal microscope.
-
The topography of as-quenched and heat treated 50(2Bi2O3-V2O5)-50SrB4O7 and 50Bi2VO5.5-50SrB4O7 glasses measured with AFM
Dane BadawczeThe topography of as-quenched and heat treated 50(2Bi2O3-V2O5)-50SrB4O7 and 50Bi2VO5.5-50SrB4O7 glasses measured with AFM.
-
Total electrical conductivity data of (Cr,Fe,Mn,Co,Ni)3O4 High-entropy spinel oxide thin films deposited on amorphous SiO2 substrate by spray pyrolysis techniqe
Dane BadawczeThis dataset includes electrical conductivity measurements results measured by van der pauw technique up to 900oC.
-
The topography of strontium–borate glasses and glass-ceramics containing bismuth and vanadium oxides measured with SEM method
Dane BadawczeThe topography of strontium–borate glasses and glass-ceramics containing bismuth and vanadium oxides was measured by SEM.
-
Thermal conductivity of M0-M100 specimens
Dane BadawczeThermal conductivity and volumetric heat capacity values of M0, M20, M40, M60, M80, M100 samples
-
Dilatometry results of SrTi0.50Fe0.50O3-d powder
Dane BadawczeThis dataset contains results of dilatometry measurements of SrTi0.50Fe0.50O3-d powder. The investigation of the linear thermal expansion was carried out using a Netzsch DIL402 dilatometer. The SrTi0.50Fe0.50O3-d powder was formed into cylinders and heat up to 1100 °C with a heating rate of 5 °C min−1, dwelled for 15 min, and then cooled at a rate of...
-
Dilatometry results of SrTi0.65Fe0.35O3-d powder
Dane BadawczeThis dataset contains results of dilatometry measurements of SrTi0.65Fe0.35O3-d powder. The investigation of the linear thermal expansion was carried out using a Netzsch DIL402 dilatometer. The SrTi0.65Fe0.35O3-d powder was formed into cylinders and heat up to 1100 °C with a heating rate of 5 °C min−1, dwelled for 15 min, and then cooled at a rate of...