Filtry
wszystkich: 353
Wyniki wyszukiwania dla: PARTIAL LOAD
-
Comparative study of a bottoming SRC and ORC for Joule–Brayton cycle cooling modular HTR exergy losses, fluid-flow machinery main dimensions, and partial loads
PublikacjaEnergy conversion efficiency increase in power plants with high-temperature gas-cooled reactors via implementation of the bottoming cycle was investigated under nominal and minimal thermal load of a high-temperature reactor (HTR). Heat transfer surface area and turbine outlet volumetric flow rate in bottoming cycles was also investigated. Water and two low-boiling point working fluids (ammonia and ethanol) were analyzed. Analyzed...
-
The Method of Multi-criteria Analysis to Support the Decision on Load or Micro-generation Connection to a Low- or Medium-voltage Power Grid
PublikacjaThis paper presents a method that supports the decision in terms on selecting the best option of a load connection to a low- or medium-voltage power distribution grid, and of a micro-generation source connection to a low-voltage grid. The method is based on the search for the option with the lowest aggregate assessment measure, which is the weighted average of partial assessment measures determined for each of eight considered...
-
Thermodynamic and economic analysis of nuclear power unit operating in partial cogeneration mode to produce electricity and district heat
PublikacjaThis paper presents the methodology of techno-economic analysis for a nuclear unit operating in partial cogeneration mode and its application for the case study: a nuclear power plant planned in Poland. The research objectives were: to propose EPR, AP1000 and ESBWR nuclear condensing-extraction turbine systems modifications required for operation in cogeneration, to determine optimal heat production and heat transport line (HTL)...
-
Design and investigations of the ethanol microturbine
PublikacjaThe paper presents the results of the design analysis and experimental investigations of the microturbine set consisting of the microturbine with partial admission and permanent magnet generator. The microturbine was designed for operation with the vapour of ethanol as a working fluid. Microturbine unit was tested for different parameters of the working fluid and varying the electrical load. The examples and the comparison between...
-
Structural Reliability Assessment Of Corroded Tanker Ship Based On Experimentally Estimated Ultimate Strength
PublikacjaThis work deals with the reliability assessment of a tanker ship hull structure subjected to a vertical bending moment and corrosion degradation. The progressive collapse and ultimate load carrying capacity are estimated based on experimentally tested scaled box-shaped-specimens. The translation of the strength estimate of the scaled specimen to the real tanker ship hull structure is performed based on the dimensional theory developing...
-
Report of Eurocode 7 application for pile foundation design in Poland
PublikacjaThe EC7 rules of geotechnical design are in use in Poland for several years, even though there is no National annex. With regard to pile foundations, there are valid EC7 recommendations concerning design approaches, load partial coefficients, correlation coefficients and capacity partial coefficients. Polish designers can be quite flexible when it comes to choose a method for static, bearing capacity and settlement calculations....
-
Nonlocalized thermal behavior of rotating micromachined beams under dynamic and thermodynamic loads
PublikacjaRotating micromachined beams are one of the most practical devices with several applications from power generation to aerospace industries. Moreover, recent advances in micromachining technology have led to huge interests in fabricating miniature turbines, gyroscopes and microsensors thanks to their high quality/reliability performances. To this end, this article is organized to examine the axial dynamic reaction of a rotating...
-
Evaluation of Partial Nitritation/Anammox (PN/A) Process Performance and Microorganisms Community Composition under Different C/N Ratio
PublikacjaA one-stage partial nitritation/anammox (PN/A) process with intermittent aeration is possible under sidestream conditions, but implementation in a mainstream is a challenge due to increased Carbon/Nitrogen (C/N) ratios in domestic wastewater. This study investigated the effect of C/N ratios on process efficiency and the effect of narrowing non-aeration time on process improvement at high chemical oxygen demand (COD) load. An increase...
-
A Comparison of the Efficiency of Deammonification under Different Aeration Strategies in a Laboratory-Scale Sequencing Batch Reactor
PublikacjaAn important source of nitrogen load entering the biological part of wastewater treatment plants (WWPTs) is derived from the anaerobic sludge digestion processes. Sludge digestion liquors constitute only 1-2% of the inflow to the plant, but the load of nitrogen directed with them to the main stream may be as high as 10-20% of the total nitrogen load. Therefore, numerous studies have focused on treatment of sludge digestion liquors...
-
Exhaust gas temperature measurements in diagnostic examination of naval gas turbine engines. Part II. Unsteady processes
PublikacjaThe second part of the article presents the results of operating diagnostic tests of a two- and three-shaft engine with a separate power turbine during the start-up and acceleration of the rotor units. Attention was paid to key importance of the correctness of operation of the automatic engine load control system, the input for which, among other signals, is the rate of increase of the exhaust gas flow temperature. The article...
-
Influence of meniscus shape in the cross sectional plane on the knee contact mechanics
PublikacjaWe present a three dimensional finite element analysis of stress distribution and menisci deformation in the human knee joint. The study is based on the Open Knee model with the geometry of the lateral meniscus which shows some degenerative disorders. The nonlinear analysis of the knee joint under compressive axial load is performed. We present results for intact knee, knee with partial and complete radial posterior meniscus root...
-
Experimental investigations and simulations of the microturbine unit with permanent magnet generator
PublikacjaIn dispersed power generation, low power devices are used for local combined generating of heat end electric power. There are developing concepts of micropower plants with electric generators driven by steam or gas microturbines. The paper presents the results of an experimental investigations of the microturbine set consists of the turbine with partial admission, permanent magnet generator and three phase AC-to-DC rectifier. The...
-
THE APPLICATION OF PHENOMENOLOGICAL METHODOLOGY FOR DESIGNING PILE FOUNDATION IN PORT STRUCTURES
PublikacjaIt is of utmost importance in the design process that a suitable, safe and concurrently economic solution be chosen. Issues connected with foundations require adopting a special approach. Soil is a composite medium, and it is essential to describe as precisely as possible the interaction taking place between the subgrade and the structure. There are many design methods of pile foundation that are based on in-situ test of soils....
-
ZAPEWNIENIE SYNCHORNIZACJI CZASU PRZY CZĘŚCIOWYM WSPARCIU SIECI
PublikacjaCelem badań zaprezentowanych w artykule było sprawdzenie czy możliwe jest zapewnienie dużej dokładności synchronizacji czasu przy częściowym wsparciu sieci w oparciu o model HRM-1 składający się z 12 szeregowo podłączonych urządzeń sieciowych wraz z wygenerowanym ruchem sieciowym. Badania wykazały, że dla obecnie stosowanych technologii mobilnych takich jak LTE TDD możliwe jest zapewnienie odpowiedniej jakości synchronizacji czasu....
-
Simple Computational Methods in Predicting Limit Load of High-Strength Cold-Formed Sections due to Local Buckling: A Case Study
PublikacjaCold-formed thin-walled sections are prone to local buckling caused by residual stresses, geometrical imperfections and inconsistency of material properties. We present a real case of buckling failure and conduct a numerical and experimental study aimed to identify methods capable of predicting such failures. It is important because designers of structures are getting more FEA-oriented and tend to avoid lengthy procedures of cold-formed...
-
Stan graniczny nośności dźwigara żelbetowego mostu na zginanie według norm PN-EN 1992-2 oraz PN-S-10042:1991
PublikacjaPraca włącza się w bogaty w ostatnich latach w krajowym piśmiennictwie nurt porównań dwóch generacji norm projektowania mostów z betonu: polskiej - wycofanej, aczkolwiek powszechnie stosowanej oraz europejskiej – wciąż jeszcze wdrażanej do praktyki projektowej. Nowością w stosunku do dotychczasowych publikacji polskich jest szersze ujęcie różnic pomiędzy obydwiema generacjami norm. Poza rozpatrywanymi przez wielu autorów różnicami...
-
„Eulerian – Eulerian” versus ,,Eulerian –Lagrangean” models of condensation
PublikacjaLiquid phase in the flowing vapor through stages of the steam turbine is the cause of a lot of failures. Nowadays, due to work of steam turbines at partial load, process of homogeneous and heterogeneous condensation still is current. The formation of drops of condensate under conditions other than nominal operation of turbine is a process still unknown. Engineers and designers involved in the development of power station machines...
-
Badania eksperymentalne strefy przypodporowej żelbetowych belek częściowo sprężonych
PublikacjaThis project refers to the study the shear zone, under full and partial prestressing in comparison to beams with passive reinforcement.For comparison, variable parameters have been determined:- a/d (from 1,5 to 3,5) - it's shear span to effective depth of the beam . Assuming constant geometrical quantities, "a" is variable.- 26 beams had no vertical shear reinforcement, and the other 26 had closed stirrups.- prestressing intensity...
-
Application of infrared thermoography to non-contact testing of varistors
PublikacjaTesting of varistors using thermography was carried out in order to assess their protective properties against possible overvoltage phenomena in the form of high-level voltage surges. An advantage of the thermography technique is non-contact temperature measurement. It was proposed to assess the properties of varistors workingin electronic devices as protective elements, on the basis of estimating temperature increments on varist...
-
Nitrogen removal via the nitrite pathway during wastewater co-treatment with ammonia-rich landfill leachates in a sequencing batch reactor
PublikacjaThe biological treatment of ammonia-rich landfill leachates due to an inadequate C to N ratio requires expensive supplementation of carbon from an external carbon source. In an effort to reduce treatment costs, the objective of the study was to determine the feasibility of nitrogen removal via the nitrite pathway during landfill leachate co-treatment with municipal wastewater. Initially, the laboratory-scale sequencing batch reactor...