Wyniki wyszukiwania dla: SOFTWARE DESIGN,
-
Testing of Software for the Planning of a Linear Object GNSS Measurement Campaign under Simulated Conditions
PublikacjaThe precision of a linear object measurement using satellite techniques is determined by the number and the relative position of the visible satellites by the receiver. The status of the visible constellation is described by DOP. The obtained geometric coefficient values are dependent on many variables. When determining these values, field obstacles at the receiver location and satellite positions changing with time must be taken...
-
MAPSERVER – INFORMATION FLOW MANAGEMENT SOFTWARE FOR THE BORDER GUARD DISTRIBUTED DATA EXCHANGE SYSTEM
PublikacjaIn this paper the architecture of the software designed for management of position and identification data of floating and flying objects in Maritime areas controlled by Polish Border Guard is presented. The software was designed for managing information stored in a distributed system with two variants of the software, one for a mobile device installed on a vessel, an airplane or a car and second for a central server. The details...
-
Policy Monitoring on Accessible Technology for Inclusive Education – Research Findings and Requirements for a Software Tool
PublikacjaStatistics about disabled people usually do not receive as much attention as statistics highlighting other socio-economic problems. However, such statistics is important due to its actual weight.According to the World Health Organization (WHO), about 15% of the world population, meaning one billion people, live with disabilities, and 80% of them live in developing countries. UNESCO claims that 90% of the children with disabilities...
-
The Multiplatform Environment for Simulation and Features Estimation of Mixed-Signal Devices
PublikacjaThe use of simulation laboratories is gaining popularity in thedomains of engineering programs. However, the experience in teaching showsthat the simulation itself is not very effective in didactic processes. Teachingprocesses in thefield of specialist subjects, designed for students of technicaluniversities, should be based on direct operations performed by the student onreal devices. At the same time, at the later stages of didactic...
-
Modeling emotions for affect-aware applications
PublikacjaThe chapter concerns emotional states representation and modeling for software systems, that deal with human affect. A review of emotion representation models is provided, including discrete, dimensional and componential models. The paper provides also analysis of emotion models used in diverse types of affect-aware applications: games, mood trackers or tutoring systems. The analysis is supported with two design cases. The study...
-
Numerical and experimental investigation of rotational stiffness of zed-purlins connection with sandwich panels
PublikacjaA rotational resistant stiffness of the zed-purlins connection with sandwich panels is investigated. A simple finite element method model of the connection is proposed. The numerical analysis of the model performed by ABAQUS software, in physically linear and geometrically nonlinear ranges, leads to the rotational resistant stiffness sought. The numerical solution obtained is verified experimentally. Two variants of distribution...
-
Nonlinear secondary arc model use for evaluation of single pole auto-reclosing effectiveness
PublikacjaPurpose – The purpose of this paper is to discuss two evaluation methods of single pole autoreclosing process effectiveness in HV transmission lines. Secondary arc current and recovery voltage results obtained by load flow calculation are compared to the results obtained by the time domain simulations. Moreover, a nonlinear secondary arc implementation is presented. Design/methodology/approach – A computer simulation studies were...
-
SDN testbed for validation of cross-layer data-centric security policies
PublikacjaSoftware-defined networks offer a promising framework for the implementation of cross-layer data-centric security policies in military systems. An important aspect of the design process for such advanced security solutions is the thorough experimental assessment and validation of proposed technical concepts prior to their deployment in operational military systems. In this paper, we describe an OpenFlow-based testbed, which was...
-
Stress Monitoring System for Individuals with Autism Spectrum Disorders
PublikacjaIn this article, a stress monitoring system tailored for individuals with Autism Spectrum Disorders (ASD) and developed for the educational institution is presented. People with ASD face problems with effective stress management due to their high self-perceived levels of stress, poor ability to cope with it, and dificulties with the accurate detection of the source of stress. Consistently, being able to measure stress appears to...
-
ECG measurement in the bathtub - getting into the bathtub- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
CAD. Integrated Architectural Design BSc in Arch., sem 3 2022/2023
Kursy OnlineDuring the course students will learn how to use BIM (Building Information Modelling) tools to model the project site and to develop preliminary design concept.Students will work in pairs or groups, using Autodesk Revit software for terrain, site and building modelling.
-
Sprzętowa i programowa realizacja algorytmu szyfrującego AES = Hardware and software implementation of AES algorithm
PublikacjaW artykule przedstawiono sprzętową i programową realizację algorytmu szyfrującego i deszyfrującego AES. Obydwie implementacje zostały zrealizowane z wykorzystaniem platformy Virtex-II i praktycznie zweryfikowane. Jako kryteria do porównania wybrano: zużycie zasobów, przepustowość i zużycie mocy. Wersja sprzętowa charakteryzuje się 190-krotnie większą przepustowością, 80-krotnie mniejszym zużyciem energii na przetworzenie jednego...
-
Software-based method of increasing the effective resolution of a measurement chain for a transducer with a pulse frequency output
Publikacja -
How Good Is My Project? Experiences from Projecting Software Quality Using a Reference Set
Publikacja -
Accurate electrothermal modelling of high frequency DC-DC converters with discrete IGBTs in PLECS software
PublikacjaIn the paper, a novel, improved method of the IGBT junction temperature computations in the PLECS simulation software is presented. The developed method aims at accuracy of the junction temperature computations in PLECS by utilising a more sophisticated model of transistor losses, and by taking into account variability of transistor thermal resistance as a function of its temperature. A detailed description of the proposed method,...
-
Preliminary Citation and Topic Analysis of International Conference on Agile Software Development Papers (2002-2018)
PublikacjaThis study utilizes citation analysis and automated topic analysis of papers published in International Conference on Agile Software Development (XP) from 2002 to 2018. We collected data from Scopus database, finding 789 XP papers. We performed topic and trend analysis with R/RStudio utilizing the text mining approach, and used MS Excel for the quantitative analysis of the data. The results show that the first five years of XP...
-
Towards mechanosynthesis of diamondoid structures: iv. The strategy for preliminary implementation of elenbogen's ''mater as software'' concept
PublikacjaOpublikowana wcześniej (Molecular Electronics and Molecular Electronic Devices, Vol. 1, Chap. 2, CRC Press, Inc. 1993, pp. 31-83) strategia budowy molekularnych urządzeń ulektronicznych w oparciu o polisilany jest rozszerzona w kierunku koncepcji Ellenbogena ''mater as software'' poprzez rozważenie użycia zamkniętej jednościennej nanorórki jako ostrza STM w celu umożliwienia manipulacji cząsteczkami sililenu.
-
Hybrid fuzzy-ontological project framework of a team work simulation system
PublikacjaThe aim of this article is to present the project framework for constructing a Software Process Simulation Modeling (SPSM) system. SPSM systems can be used as a virtual environment for the selection of methods and tools of project management in IT support organizations. The constructed system simulates the Scrum methodology, including the management processes and the project roles. For the implementation of Scrum processes, the...
-
Quality of Test Specification by Application of Patterns
PublikacjaEmbedded system and software testing requires sophisticated methods, which are nowadays frequently supported by application of test patterns. This eases the test development process and contributes to the reusability and maintainability of the test specification. However, it does not guarantee the proper level of quality and test coverage in d ifferent dimensions of the test specification. In this paper the quality of the test...
-
Realizacja mobilnego urządzenia do wytwarzania kurtyny elektromagnetycznej do zastosowań specjalnych
PublikacjaIn the article the assumptions, design and realisation of the technological demonstrator of a mobile device for generating an electromagnetic curtain (AEGIS) were presented, both in the area of hardware and software. The device is designed to block radio communication by which it is possible to detonate the Radio Controlled Improvised Explosive Devices (RCIEDs). The preliminary laboratory tests of the demonstrator for generating...
-
Modeling Object Oriented Systems via Controlled English Verbalization of Description Logic
PublikacjaThe need for formal methods for Object Oriented (OO) systems resulted in methods like UML and Lepus3 that are de-facto graphical languages equipped with formal tools that are able to handle the design of OO systems. However, they lack precise semantics which might lead to problems, such as inconsistencies or redundancies. On the other hand, to our knowledge, there is no approach that allows one to understand and follow the requirements...
-
ECG measurement in the bathtub - drl on the outside of the bathtub on one side- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, drl behind the back - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at buttocks, strengthening 2x smaller, drl at buttocks - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the buttocks, drl at the feet - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - one side of the bathtub is grounded, drl outside the bathtub - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the knees - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, sitting motionless - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the knees, signal amplification x2 - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the buttocks, drills at the feet, grounding the bathtub - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, placed on the back - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - sitting on the measuring electrodes, drl outside the bathtub - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl on the outside of the bathtub on both sides, measuring electrodes on the front and back of the bathtub- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl in the water, measuring electrodes on the sides of the bathtub - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl on one side of the bath mass on the other - the person is moving- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl outside the bathtub on both sides- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl in water, front and back measuring electrodes - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, bath simulation - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - sitting on measuring electrodes, drl in water - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, drl at the buttocks - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl on one side of the bath, the mass of the system on the other- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - conversation during measurement, electrodes on the sides of the bathtub, drl in water - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl in the bathtub, electrodes on the sides of the bathtub - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, drl at the knees - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the buttocks - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, bath simulation - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - buttocks electrodes, reinforcement 2x smaller, drl on knees - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
Impact of Feature Selection Methods on the Predictive Performance of Software Defect Prediction Models: An Extensive Empirical Study
Publikacja -
Hardware-Software Implementation of a Sensor Network for CityTraffic Monitoring Using the FPGA- and ASIC-Based Sensor Nodes
PublikacjaArtykuł opisuje prototypową sieć sensorową do monitorowania ruchu pojazdów w mieście. Węzły sieci sensorowej, wyposażone w kamerę o niskiej rozdzielczości, obserwują ulice i wykrywają poruszające się obiekty. Detekcja obiektów jest realizowana w oparciu o własny algorytm segmentacji obrazów, wykorzystujący podwójne odejmowanie tła, wykrywanie krawędzi i cieni, działający na dedykowanym systemie mikroelektronicznym typu ''System...
-
Scaled agile framework. Dealing with software process‐related challenges of a financial group with the action research approach
PublikacjaThis article reports on a domain-specific software development venture at Nordea. We explore organizational constraints, challenges, and corrective actions undertaken when scaling the agile development approach of their Core Banking Platform program. The fit and required customizations of the rather complex and rigid SAFe framework in a policy-heavy financial institution are audited against the organic growth of the program. In...