Filtry
wszystkich: 3316
-
Katalog
- Publikacje 2638 wyników po odfiltrowaniu
- Czasopisma 72 wyników po odfiltrowaniu
- Konferencje 10 wyników po odfiltrowaniu
- Osoby 112 wyników po odfiltrowaniu
- Wynalazki 1 wyników po odfiltrowaniu
- Projekty 4 wyników po odfiltrowaniu
- Aparatura Badawcza 1 wyników po odfiltrowaniu
- Kursy Online 36 wyników po odfiltrowaniu
- Wydarzenia 3 wyników po odfiltrowaniu
- Oferty 1 wyników po odfiltrowaniu
- Dane Badawcze 438 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: OPTOCOUPLER DEVICE
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Man 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows to the body - Woman 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Woman 24 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Man 53 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows to the body - Man 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows to the body - Man 53 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Man 53 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Woman 24 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 24 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Man 53 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows in the air - Man 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows in the air - Woman 24 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Woman 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Woman 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Man 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows in the air - Woman 30 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - microsphere inspection s.2
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - microsphere inspection s.1
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Parallel Programming for Modern High Performance Computing Systems
PublikacjaIn view of the growing presence and popularity of multicore and manycore processors, accelerators, and coprocessors, as well as clusters using such computing devices, the development of efficient parallel applications has become a key challenge to be able to exploit the performance of such systems. This book covers the scope of parallel programming for modern high performance computing systems. It first discusses selected and...
-
PROBLEMS OF THE STARTING AND OPERATING OF HYDRAULIC COMPONENTS AND SYSTEMS IN LOW AMBIENT TEMPERATURE (PART IV) MODELLING THE HEATING PROCESS AND DETERMINING THE SERVICEABILITY OF HYDRAULIC COMPONENTS DURING THE STARTING-UP IN LOW AMBIENT TEMPERATURE
PublikacjaDesigners of hydraulically driven machines and devices are obliged to ensure during design process their high service life with taking into account their operational conditions. Some of the machines may be started in low ambient temperature and even in thermal shock conditions (due to delivering hot working medium to cold components). In order to put such devices into operation appropriate investigations, including experimental...
-
A Five-Leg Three-Level Dual-Output Inverter
PublikacjaClassical 3-level dual-output inverter, 3-L DOI, involves two similar 3-level inverters that provides a pair of 3-phase output voltages with same or different frequencies from common input voltage source. Flexibility of either operation of the constituting inverters is evident in this DOI; but total duplication of power switches is a major drawback. State of the art coupled 3-L DOIs reduce this drawback by providing series-shared...
-
Dimensioning of vortex storm overflows
PublikacjaVortex flow control can be made as a rotational chamber, where the centrifugal force is a supporting factor. The paper presents a simplified, but experimentally verified, method of such device designing.
-
Energy-Aware High-Performance Computing: Survey of State-of-the-Art Tools, Techniques, and Environments
PublikacjaThe paper presents state of the art of energy-aware high-performance computing (HPC), in particular identification and classification of approaches by system and device types, optimization metrics, and energy/power control methods. System types include single device, clusters, grids, and clouds while considered device types include CPUs, GPUs, multiprocessor, and hybrid systems. Optimization goals include various combinations of...
-
Real-time hybrid model of a wind turbine with doubly fed induction generator
PublikacjaIn recent years renewable sources have been dominating power system. The share of wind power in energy production increases year by year, which meets the need to protect the environment. Possibility of conducting, not only computer simulation, but also laboratory studies of wind turbine operation and impact on the power system and other power devices in laboratory conditions would be very useful. This article presents a method...
-
A Set of Low-power Microcontroller-based Modules Used for Testing of Small Energy Measurement Methods
PublikacjaEstimation of energy consumption of low-power devices is not widely discussed in the scientific literature, but this topic is getting more and more popular. Evaluation process of newly developed methods and instrumentation requires carefull treatment. In order to fulfill this niche, the set of micro-power microcontroller based devices was proposed. The devices represent typical energy consuption profiles and allow experimental verification...
-
Discrete and continuous fractional persistence problems – the positivity property and applications
PublikacjaIn this article, we study the continuous and discrete fractional persistence problem which looks for the persistence of properties of a given classical (α=1) differential equation in the fractional case (here using fractional Caputo’s derivatives) and the numerical scheme which are associated (here with discrete Grünwald–Letnikov derivatives). Our main concerns are positivity, order preserving ,equilibrium points and stability...
-
New data acquisition system for birch sap concentrate production using the reverse osmosis technology
PublikacjaThe work presents a simple electronic device that helps to monitor the basic parameters of the reverse osmosis (RO) system during the concentration of birch tree sap. The construction costs are low (around 150 Euro) but the functionality of the device is high. It has an in-build two channel conductometer and can measure the volumetric flow rate of two streams of liquids. The collected data are transmitted wirelessly via Bluetooth...
-
Monika Wilamowska-Zawłocka dr hab. inż.
OsobyDr hab. inż. Monika WILAMOWSKA-ZAWŁOCKA jest absolwentką Wydziału Chemicznego Politechniki Gdańskiej. Studia doktoranckie ukończyła w 2011 r., następnie odbyła roczny staż na Technicznym Uniwersytecie w Darmstadt w Niemczech. Pracuje w Politechnice Gdańskiej od 2013 r., od 2019 r. na stanowisku profesora uczelni. Specjalność –materiały elektrodowe w zastosowaniu do ogniw litowo-jonowych, sodowo-jonowych, kondensatorów elektrochemicznych...
-
Semantic Integration of Heterogeneous Recognition Systems
PublikacjaComputer perception of real-life situations is performed using a variety of recognition techniques, including video-based computer vision, biometric systems, RFID devices and others. The proliferation of recognition modules enables development of complex systems by integration of existing components, analogously to the Service Oriented Architecture technology. In the paper, we propose a method that enables integration of information...
-
Modeling energy consumption of parallel applications
PublikacjaThe paper presents modeling and simulation of energy consumption of two types of parallel applications: geometric Single Program Multiple Data (SPMD) and divide-and-conquer (DAC). Simulation is performed in a new MERPSYS environment. Model of an application uses the Java language with extension representing message exchange between processes working in parallel. Simulation is performed by running threads representing distinct process...
-
Time series of Doppler blood flow recordings
Dane BadawczeVital signals registration plays a grate role in biomedical engineering and education process. Well acquired data allow future engineers to observe certain physical phenomenons as well learn how to correctly process and interpret the data. This data set was designed for students to learn about Doppler phenomena and to demonstrate correctly and incorrectly...
-
PULSE and ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Second Man 29 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Woman 27 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Woman 28 age
Dane BadawczeThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
Accurate Computation of IGBT Junction Temperature in PLECS
PublikacjaIn the article, a new method to improve the accuracy of the insulated-gate bipolar transistor (IGBT) junction temperature computations in the piecewise linear electrical circuit simulation (PLECS) software is proposed and described in detail. This method allows computing the IGBT junction temperature using a nonlinear compact thermal model of this device in PLECS. In the method, a nonlinear compact thermal model of the IGBT is...
-
Supply current spectrum estimation of digital cores at early design
PublikacjaPrzedstawiono nową aproksymacyjną metodę obliczania widma prądu zasilania układów cyfrowych. Metoda oparta jest na charakterystyce impulsów prądowych w kategoriach ich czasu narastania, opadania i długości impulsu. Górną granicę widma (obwiednię) można obliczyć posługując się gęstością prawdopodobieństwa zmian stanu sygnałów w węzłach układu cyfrowego. W odróżnieniu od znanych metod, metoda proponowana wykorzystuje ograniczoną...
-
Modeling of TiO2-Based Electron-Selective Contacts for Crystalline Silicon Solar Cells
Publikacja -
Frequency compensation for two-stage operational amplifiers with improved PSRR characteristic
PublikacjaW pracy została opisana nowa metoda kompensacji częstotliwościowej dwustopniowych wzmacniaczy operacyjnych. Metoda kompensacji gwarantuje uzyskanie stabilnej pracy wzmacniacza operacyjnego przy założeniu że wzmocnienie układu z zamkniętą pętlą sprzężenia zwrotnego jest ograniczone do wartości kilkunastu decybeli. W porównaniu do innych znanych metod kompensacji, zaproponowana metoda umożliwia co najmniej dziesięciokrotne poszerzenie...
-
Output-capacitorless low-dropout regulator using a cascoded flipped voltage follower
PublikacjaPrzedstawiono udoskonaloną konfigurację wtórnika napięciowego w odwróconej konfiguracji oraz jej zastosowanie w regulatorze o małym spadku napięcia. W pracy przedstawiono teoretyczną analizę podstawowych parametrów wtórnika oraz regulatora napięcia. Ponadto przedstawiono wyniki pomiarów parametrów prototypowego układu scalonego wykonanego z użyciem technologii CMOS 0.35 um. Uzyskane wyniki porównano z rezultatami uzyskanymi w innych...
-
Highly linear CMOS triode transconductor for VHF applications
PublikacjaA high-speed, fully balanced complementary-symmetry metal-oxide-semiconductor (CMOS) triode transconductor is presented. The proposed approach exploits a pseudo-differential-pair triode configuration with a simple adaptive circuit stabilising the drain-to-source voltages of metal-oxide-semiconductor (MOS) transistors. Since no additional active circuits (apart from the resistors made of the cut-off MOS devices) and no feedback...
-
Prototype of a low-cost luxmeter with wide measuring range designed for railway stations dynamic lighting systems
PublikacjaThe paper presents the development of a low-cost luxmeter designed for usage in automatic applications for continual (long-term) measurement of illuminance. The measured information is used to adjust the level of lighting systems of artificial lighting on railways (platforms, marshalling yard, tracks etc.). The reason of this measuring device is a requirement for massive deployment of dimmable lighting systems for railways, in...
-
A detector of sleep disorders for using at home
PublikacjaObstructive sleep apnea usually requires all-ni ght examination in a specialized clinic, under the supervision of a medical staff. Because of those requirements it is an expensive and a non-widely utilized test. Moving the examination procedure to patients’ home with automatic analysis algorithms involved will decrease the costs and make it available for larger group of patients. The developed device allows all-night recordings...
-
A Review of Recent Advances in Human-Motion Energy Harvesting Nanogenerators, Self-Powering Smart Sensors and Self-Charging Electronics
PublikacjaIn recent years, portable and wearable personal electronic devices have rapidly developed with increasing mass production and rising energy consumption, creating an energy crisis. Using batteries and supercapacitors with limited lifespans and environmental hazards drives the need to find new, environmentally friendly, and renewable sources. One idea is to harness the energy of human motion and convert it into electrical energy...
-
Analysis of Ferroresonance Mitigation Effectiveness in Auxiliary Power Systems of High-Voltage Substations
PublikacjaFerroresonance in power networks is a dangerous phenomenon, which may result in overcurrents and overvoltages, causing damage to power equipment and the faulty operation of protection systems. For this reason, the possibility of the occurrence of ferroresonance has to be identified, and adequate methods need to be incorporated to eliminate or reduce its effects. The aim of this paper is to evaluate the effectiveness of ferroresonance...
-
Electrochemical studies of symmetrical supercapacitors based on BDD, Mn-BDD, Mn-BDD(AN) electrodes
Dane BadawczeElectrochemical performance of a Supercapacitor device in PVA-H2SO4 gelled electrolyte: Cyclic voltammograms at varying scan rates ranging from 10 to 1000 mV s−1, galvanostatic charge-discharge curves with varying current density, cyclic stability (88000 charge-discharge cycles).
-
Relieving the Measuring System of the Trailer for Tyre/Road Rolling Resistance Measurements from the Inertia Force
PublikacjaIn the article the principle of measuring of tyre/road rolling resistance tyres in road conditions applied in a special measuring trailer is presented. This trailer was built in Faculty of Mechanical Engineering at Gdansk University of Technology. The construction of two special devices used in this trailer was discussed. These devices eliminate the influence of some chosen confounding measurements factors such as: the inertia...
-
Signals of the NB-IoT network generated by using the radiocommunication tester R&S CMW500
Dane BadawczeThe published dataset contains signals of the NB-IoT networks generated in the controlled conditions by using the Rohde&Schwarz CMW500 radiocommunication tester and recorded by USRP-X310 device. A test signals of the NB-IoT networks operating in the in-band, standalone and guard-band modes were captured.
-
Innovative method of localization airplanes in VCS (VCS-MLAT) distributed system
PublikacjaThe article presents the concept and the structure of the localization module. The prototype module is the part of the VCS (VCS-MLAT) localization distributed system. The device receives the audio signal transmitted in airplanes band (118 MHz – 136 MHz). Received data with the timestamps are send to the main server. The data from multiple devices estimates the localization of the airplane. The main aim of the project is the analysis...
-
Horizontally-split-drain MAGFET - a highly sensitive magnetic field sensor
PublikacjaWe propose a novel magnetic field sensitive semiconductor device, viz., Horizontally-Split-Drain Magnetic-Field Sensitive Field-Effect Transistor (HSDMAGFET) which can be used to measure or detect steady or variable magnetic fields. Operating principle of the transistor is based on one of the galvanomagnetic phenomena and a Gradual Channel Detachment Effect (GCDE) and is very similar to that of Popovic and Baltes's SDMAGFET. The...