Application of Barkhausen effect in the impact assessment of welding to internal stress distribution in steel
PublikacjaThe paper presents identification method of internal stresses in plane steel elements in the chase of deliverance and welding assembly. The assessment was made by means of a non-destructive experimental method based on measurements incorporating local external magnetic field and the measurement of induced voltage, including Barkhausen noise. This method allows a degradation assessment due to internal and external actions, causing...
-
A vertical subway, namely, an internal transport system in a 1200 m tall building,
PublikacjaThis article deals with the topic of designing an efficient internal transport system in a 1200 m tall multifunctional building called the “World’s Tower” due to its symbolism and specific architectural form. The building comprises four towers whose bases are 75 m/75 m long each and whose height is 1200 m. Two of the towers are located along the north-south axis while the two others along the east-west one. The towers are joined...
-
Assessing Acute Toxicity of Selected Packages Internal Layers Extracts using Microtox®
PublikacjaIn the scientific literature related to the widely understood issue of packaging materials designed to have contact with food (food contact materials), there is much information on raw materials used for their production, as well as their physiochemical properties, types and parameters. Unfortunately, not much attention is given to the issues concerning migration of toxic substances from packaging and its actual influence on the...
-
Internal imaging of concrete fracture based on elastic waves and ultrasound computed tomography
PublikacjaThe condition assessment of concrete structures belongs to the greatest challenges of non-destructive testing. Monitoring the fracture process of concrete and detecting cracks at the earliest possible stage is a vital aspect to ensure the safety of civil engineering objects. The use of ultrasound tomography enables imaging the internal structure of a tested element. This study aims at the visualization of fracture damage in concrete...
-
Urban city lights. Light pollution as one of the effects of incorrectly designed external illumination. How can a successful lighting masterplan diminish its impact?
PublikacjaIn the modern world, artificial lighting brings many tangible benefits such as the ability to extend working hours and so increase production, recreational use of the city after dark, or the possibility to travel regardless of the time of day. However, this flexibility comes at a price and negatively impacts on the environment. One such negative phenomenon is Light Pollution ‐ a term used to describe excessive nighttime artificial...
-
Journal of Maternal-Fetal & Neonatal Medicine
Czasopisma -
Preparation of Internal Standards for 2D-UPLC-MS/MS Quantification of Noncanonical DNA Bases
Publikacja -
Identification analysis of dynamic changes in the composition of biogas and their impact on the operation of internal combustion engines
PublikacjaW pracy zamieszczono wyniki badań składu biogazu pozyskiwanego na komunalnym wysypisku śmieci. Pozyskiwany biogaz jest wykorzystywany do zasilania biogazowych zespołów prądotwórczych wyposażonych w silniki o zapłonie iskrowym dostosowanych do zasilania tym paliwem. Pozyskiwany biogaz powstaje w sposób naturalny w procesie beztlenowej fermentacji zachodzącej przez ok. 20 lat, w organicznej części pryzmy odpadów składowanych na wysypisku...
-
Fiber - optic low-coherence tomography system for visualization of internal structure of ceramic materials
PublikacjaW artykule przedstawiono światłowodowy system dwuwymiarowej wizualizacji niejednorodnych struktur warstw ceramicznych. Omówiono projekt i fizyczną realizację układu wykorzystującego optyczną, niskokoherentną reflektometrię optyczną, która umożliwia niedestrukcyjne obrazowanie wewnętrznych struktur różnych materiałów. W pracy przedstawiono przykładowe wyniki pomiarów wewnętrznych warstw LSFO.
-
Experimental investigation of Steel–Concrete–Polymer composite barrier for the ship internal tank construction
PublikacjaTransportation of dangerous cargo by ships demands ensuring an appropriate protection level in case of an accident. Two of the most dangerous accident types resulting in an oil spill are grounding and ship to ship collision. The article presents results of research on a new composite construction for a ship hull that increases structural safety during collision. The concept of semi-elastic Steel–Concrete–Polymer structure is presented....
-
Application of Barkhausen method to determine internal stresses in cold-rolled and hot-rolled sheets
PublikacjaThe paper presents investigations on internal stress distribution in plane hot—or cold-rolled sheets dedicated for the cold-formed profiles. The motivation of the research is a new profile design whose bending technology, incorporating a longitudinal welded joint and hot-dip galvanization after bending and welding introduces additional internal stresses. In order to identify the entirety of stresses in the process of sheet production...
-
Problems of modelling toxic compounds emitted by a marine internal combustion engine in unsteady states
PublikacjaContemporary engine tests are performed based on the theory of experiment. The available versions of programmes used for analysing experimental data make frequent use of the multiple regression model, which enables examining effects and interactions between input model parameters and a single output variable. The use of multi-equation models provides more freedom in analysing the measured results, as those models enable simultaneous...
-
Application of twin-plane ECT sensor for identification of the internal imperfections inside concrete beams
PublikacjaThe main purpose of this paper is to investigate application of special construction of Electrical Capacitance Tomography (ECT) sensor to concrete beams internal homogeneity tests. Identification of internal imperfection inside the concrete beams is one of the main problems related to analysis of the construction structure bearing capacity. Therefore, this paper shows attempts to study the measurement prospects for this non-invasive,...
-
Application of the Mathar method to identify internal stress variation in steel as a welding process result
PublikacjaThe paper deals with the method to identify internal stresses in two-dimensional steel members. Steel members were investigated in the delivery stage and after assembly, by means of electric-arc welding. In order to perform the member assessment two methods to identify the stress variation were applied. The first is a non-destructive measurement method employing local external magnetic field and to detecting the induced voltage,...
-
Quantumness in Diagnostics of Marine Internal Combustion Engines and Other Ship Power Plant Machines
PublikacjaThe article provides proof that the diagnostics of marine internal combustion engines and other ship power plant machines should take into account the randomness and unpredictability of certain events, such as wear, damage, the variations of mechanical and thermal loads, etc., which take place during machine operation. In the article, the energy E, like the other forms (methods) that it can be converted into (heat and work), is...
-
Assessing Acute Toxicity and Endocrine Disruption Potential of Selected Packages Internal Layers Extracts
PublikacjaThe focus of the present study is migration of toxic substances from food contact materials and its actual influence on the health of the final consumer. Two food packagings (metal cans, TetraPack®) and five simulants medias (water, ethanol, acetic acid, DMSO, artificial saliva) were selected for simulation studies. For assessment of acute toxicity and endocrine disruption potential of extract samples, two biotests (Microtox® and...
-
External thrombosed haemorrhoids - Male, 32 - Tissue image [4200730008413231]
Dane BadawczeThis is the histopathological image of ANUS AND ANAL CANAL tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
External thrombosed haemorrhoids - Male, 32 - Tissue image [4200730008415601]
Dane BadawczeThis is the histopathological image of ANUS AND ANAL CANAL tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
External thrombosed haemorrhoids - Male, 32 - Tissue image [4200730008417991]
Dane BadawczeThis is the histopathological image of ANUS AND ANAL CANAL tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
External thrombosed haemorrhoids - Male, 32 - Tissue image [4200730008414671]
Dane BadawczeThis is the histopathological image of ANUS AND ANAL CANAL tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
External thrombosed haemorrhoids - Male, 32 - Tissue image [4200730008411521]
Dane BadawczeThis is the histopathological image of ANUS AND ANAL CANAL tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
The influence of external interference on AFM imaging, the use of a protective helmet
Dane BadawczeThis collection is of purely practical importance, showing how the presence of external disturbances can adversely affect the quality of imaging with an atomic force microscope. For this reason, it is also advisable to provide a link to a workshop-like study [1] as well as a huge number of commercial solutions available after entering the keyword "AFM...
-
Determination of changes in viscosity of hydrogel depending on shear rate (1.1 to 55 s-1).
Dane BadawczeThe rheological characteristics of hydrogel were made on the basis of a viscosity measurement using a Brookfield viscometer, using LV SC4 - 25 spindle and shear rates from 1.1 to 55 s-1.
-
Determination of changes in viscosity of refined oil depending on the temperature (19-96 Celsius degrees).
Dane BadawczeThe rheological characteristics of the refined oil were made on the basis of the viscosity assessment using a Brookfield viscometer with an LV SC4 - 18 spindle and a shear rate of 52.8 s-1 in from temperature 19-96 °C.
-
Determination of changes in viscosity of hydrogel depending on shear rate (1.7 to 34 s-1).
Dane BadawczeThe rheological characteristics of hydrogel were made on the basis of a viscosity measurement using a Brookfield viscometer, using LV SC4 - 27 spindle and shear rates from 1.7 to 34 s-1.
-
Determination of changes in viscosity of hydrogel depending on shear rate (6.6 to 330 s-1).
Dane BadawczeThe rheological characteristics of hydrogel were made on the basis of a viscosity measurement using a Brookfield viscometer, using LV SC4 - 18 spindle and shear rates from 6.6 to 330 s-1.
-
Determination of changes in viscosity of poly(acrylic acid) PAA solutions depending on shear rate.
Dane BadawczeThe rheological characteristics of poly(acrylic acid) PAA solutions were based on viscosity measurements using a Brookfield viscometer, using LV SC4 - 27 spindles and shear rates from 1,7 to 39 s-1 (Fig. 1). PAA solutions with were prepared in water. The data allowed to characterize the used PAA and assess their functional parameters as rheology modifying...
-
New Type of Small Broad-Band Internal Antenna for Third Generation Mobile Phone Handsets.
PublikacjaW pracy przedstawiono nową szerokopasmową antenę łatową przeznaczoną dla telefonów komórkowych trzeciej generacji. Proponowana struktura zawiera obwód (rezonator) w kształcie litery U i zaliczana jest do klasy PIFA (planar inverted-F antenna). W trakcie procesu projektowania przeprowadzono szereg symulacji elektromagnetycznych (metoda momentów), których wyniki zweryfikowano w oparciu o pomiary charakterystyk wykonanego prototypu....
-
Brachytherapy boost improves survival and decreases risk of developing distant metastases compared to external beam radiotherapy alone in intermediate and high risk group prostate cancer patients
Publikacja -
CERVIX UTERI, External os - Female, 45 - Tissue image [3220630024695731]
Dane BadawczeThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, External os - Female, 45 - Tissue image [3220630024692641]
Dane BadawczeThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, External os - Female, 35 - Tissue image [4050730010681651]
Dane BadawczeThis is the histopathological image of CERVIX UTERI tissue sample obtained in University of Warmia and Mazury in Olsztyn and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, External os - Female, 35 - Tissue image [4050730010688711]
Dane BadawczeThis is the histopathological image of CERVIX UTERI tissue sample obtained in University of Warmia and Mazury in Olsztyn and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, External os - Female, 45 - Tissue image [3220630024698231]
Dane BadawczeThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, External os - Female, 45 - Tissue image [3220630024696541]
Dane BadawczeThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, External os - Female, 57 - Tissue image [3220630024674891]
Dane BadawczeThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, External os - Female, 45 - Tissue image [3220630024698701]
Dane BadawczeThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, External os - Female, 57 - Tissue image [3220630024671001]
Dane BadawczeThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, External os - Female, 35 - Tissue image [4050730010685081]
Dane BadawczeThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, External os - Female, 33 - Tissue image [9160729581055241]
Dane BadawczeThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, External os - Female, 45 - Tissue image [3220630024695401]
Dane BadawczeThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, External os - Female, 45 - Tissue image [322063002469611]
Dane BadawczeThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, External os - Female, 57 - Tissue image [3220630024675131]
Dane BadawczeThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, External os - Female, 35 - Tissue image [4050730010684661]
Dane BadawczeThis is the histopathological image of CERVIX UTERI tissue sample obtained in University of Warmia and Mazury in Olsztyn and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, External os - Female, 45 - Tissue image [3220630024692581]
Dane BadawczeThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, External os - Female, 35 - Tissue image [4050730010682671]
Dane BadawczeThis is the histopathological image of CERVIX UTERI tissue sample obtained in University of Warmia and Mazury in Olsztyn and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, External os - Female, 45 - Tissue image [3220630024692171]
Dane BadawczeThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, External os - Female, 33 - Tissue image [9160729581055441]
Dane BadawczeThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, External os - Female, 35 - Tissue image [4050730010684501]
Dane BadawczeThis is the histopathological image of CERVIX UTERI tissue sample obtained in University of Warmia and Mazury in Olsztyn and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
CERVIX UTERI, External os - Female, 35 - Tissue image [4050730010683301]
Dane BadawczeThis is the histopathological image of CERVIX UTERI tissue sample obtained in University of Warmia and Mazury in Olsztyn and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.