Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 150 mm stroke subjected only to a mass load of 1100 g
Dane Badawcze -
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 150 mm stroke subjected only to a mass load of 1530 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 100 mm stroke subjected only to a mass load of 1650 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 1640 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 300 mm stroke subjected only to a mass load of 1650 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 100 mm stroke subjected only to a mass load of 930 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 300 mm stroke subjected only to a mass load of 930 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 150 mm stroke subjected only to a mass load of 1650 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 100 mm stroke subjected only to a mass load of 450 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 500 mm stroke subjected only to a mass load of 1530 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 300 mm stroke subjected only to a mass load of 1680 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 150 mm stroke subjected only to a mass load of 930 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 560 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 1040 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 100 mm stroke subjected only to a mass load of 640 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 300 mm stroke subjected only to a mass load of 1530 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 150 mm stroke subjected only to a mass load of 1040 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 150 mm stroke subjected only to a mass load of 640 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 100 mm stroke subjected only to a mass load of 900 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 300 mm stroke subjected only to a mass load of 2570 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 150 mm stroke subjected only to a mass load of 2570 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 750 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 300 mm stroke subjected only to a mass load of 1040 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 100 mm stroke subjected only to a mass load of 1530 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 150 mm stroke subjected only to a mass load of 1640 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 100 mm stroke subjected only to a mass load of 1100 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 100 mm stroke subjected only to a mass load of 2570 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Elżbieta Urbańska-Galewska dr hab. inż.
Osoby -
Free-standing TiO2 nanotubes decorated with spherical nickel nanoparticles as a cost-efficient electrocatalyst for oxygen evolution reaction
PublikacjaHere, we report significant activity towards the oxygen evolution reaction (OER) of spherical nickel nanoparticles (NPs) electrodeposited onto free-standing TiO2 nanotubes (TNT) via cyclic voltammetry. It has been shown that simple manipulation of processing parameters, including scan rate and number of cycles, allows for formation of the NPs in various diameters and amounts. The polarization data with respect to transmission electron...
-
Path Loss Analysis for the IoT Applications in the Urban and Indoor Environments
PublikacjaThe Internet of Things (IoT) networks concept implies their presence in a various and untypical locations, usually with a disturbed radio signals propagation. In the presented paper an investigation of an additional path loss observed in an underground environment was described. The proposed measurement locations correspond to the operation areas of rapidly growing narrowband IoT (NBIoT) networks, the ones using the Long Term Evolution...
-
Circulating Hematopoietic (HSC) and Very-Small Embryonic like (VSEL) Stem Cells in Newly Diagnosed Childhood Diabetes type 1 – Novel Parameters of Beta Cell Destruction/Regeneration Balance and Possible Prognostic Factors of Future Disease Course
Publikacja -
Diabetes & Vascular Disease Research
Czasopisma -
Theoretical analysis of heat transfer between a liquid layer formed by an impinginf gas liquid jet AND a solid surface
PublikacjaHeat transfer phenomenon between a horizontal solid surface and a liquid layer created on a surface by an axisymmetrical liquid gas impinging jet has been analysed. The analytical treatment of the phenomenon is devoted to the area whose diameter is lower than the diameter of the hydraulic jump. W pracy przedstawiono teoretyczną analizę wymiany ciepła pomiędzy warstwą cieczy a stałą powierzchnią po której przepływa.
-
The Effect of Long Term Service at Elevated Temperatures on Microstructure Degradation of Austenitic Reformer Tubes
PublikacjaThe paper analyses the relationship between an increase of the inner diameter of tubes made of Manaurite XM cast steel and transformations occurring in their microstructure due to long-lasting operation in methane reformer. Examinations included metallographic analysis with light microscope (LM), scanning electron microscope (SEM) and microanalysis of the chemical composition of precipitates (EDX). It was indicated that there is...
-
Zastosowanie addytywów w separacji pianowej białek serwatkowych i białek mlecznych
PublikacjaZaproponowano proces separacji pianowej do wydzielania białek ze strumieni poprodukcyjnych przemysłu mleczarskiego Ponadto zaproponowano zastosowanie w separacji pianowej białek serwatkowych i mlecznych addytywów dopuszczonych ustawą do stosowania w żywności. Jako cel pracy przyjęto uzyskanie wyników uzasadniających wybór takich addytywów, które intensyfikują przebieg i polepszają wynik procesu separacji pianowej białek. W części...
-
Estymacja jakości transmisji w systemie LTE na podstawie wskaźników mierzonych przez moduł radiowy
PublikacjaW referacie zaprezentowano stanowisko pomiarowe do badania jakości transmisji w systemie LTE. Przedstawiono także wyniki pomiarów BLER oraz przepływności dla różnych warunków propagacyjnych oraz mierzone przez moduł parametry RSRP, RSRQ, RSSI, SINR i MCS. Wyniki pomiarów posłużyły do przeprowadzenia analizy możliwości estymacji jakości transmisji w systemie LTE jedynie na podstawie wyników pomiarów realizowanych przez komercyjny...
-
Effect of the Cavitation Generation Unit Structure on the Performance of an Advanced Hydrodynamic Cavitation Reactor for Process Intensifications
PublikacjaThe advanced rotational hydrodynamic cavitation reactors (ARHCRs) that appeared recently have shown obvious advantages compared with conventional devices in process intensifications. In ARHCRs, the cavitation generation unit (CGU) located on the rotor and stator basically determines their performance. For the first time, the present study investigated the effect of the CGU structure on the performance of a representative ARHCR...
-
Reconfiguring Minimum Dominating Sets in Trees
PublikacjaWe provide tight bounds on the diameter of γ-graphs, which are reconfiguration graphs of the minimum dominating sets of a graph G. In particular, we prove that for any tree T of order n ≥ 3, the diameter of its γ-graph is at most n/2 in the single vertex replacement adjacency model, whereas in the slide adjacency model, it is at most 2(n − 1)/3. Our proof is constructive, leading to a simple linear-time algorithm for determining...
-
High-performance NdSrCo2O5+δ–Ce0.8Gd0.2O2-δ composite cathodes for electrolyte-supported microtubular solid oxide fuel cells
PublikacjaNdSrCo2O5+δ (NSCO) is a perovskite with an electrical conductivity of 1551.3 S cm−1 at 500 °C and 921.7 S cm−1 at 800 °C and has a metal-like temperature dependence. This perovskite is used as the cathode material for Ce0.8Gd0.2O2-δ (GDC)-supported microtubular solid oxide fuel cells (MT-SOFCs). The MT-SOFCs fabricated in this study consist of a bilayer anode, comprising a NiO–GDC composite layer and a NiO layer, and a NSCO–GDC...
-
Impact of steel grade on a ship colliding with an offshore wind turbine monopile supporting structure
PublikacjaOffshore wind power is experiencing rapid development around the world. The number of installations and their size is growing. Thousands of monopile support structures with diameters of 10 m and weights of 2000 tons will be installed in the coming years. Offshore wind power installations, often located close to the shore and shipping routes, pose a new challenge to ship safety. The study analyses the damages from an accidental...
-
EVALUATION OF EFFECTIVENESS OF WATERJET PROPULSOR FOR A SMALL UNDERWATER VEHICLE
PublikacjaT he goal of the project described is to replace the existing propulsion system of a small underwater vehicle with a solution less prone to mechanical damage and ensuring a lower risk of the entanglement of fibrous objects suspended in the body of water. Four typical marine screws are utilised in the current design of the vehicle. One possible solution of the problem is the application of waterjet propulsors located...
-
International Journal of Diabetes in Developing Countries
Czasopisma -
Experimental and comparative study on the two-phase pressure drop of air-water mixture in U-bend and straight pipe annuli
PublikacjaIn this paper, the experimental and theoretical analysis of pressure drop in singlephase and two phase-flow were presented for straight and U-bend smooth tube annulus and tube annulus with wire coil insert. Experiments for various boundary conditions were performed. In case of U-tube and straight tube with and without turbulator, tests were made for the water-water and air-water systems. The study covered a wide measuring range,...
-
Comparative analysis of coaxial magnetocumulative generators
PublikacjaThis paper presents the results of a computer simulation of coaxial magnetocumulative current generators (MCGs). The simulation tests were carried out for different values of the internal diameter, length and speed of the deformation of the MGP element.
-
Granulometric analysis to etimate influence of anionic surfactrant on activated sludge structure
PublikacjaThe work concerns the evaluation of the possibility of using laser diffraction analyzer to determine changes in the distribution of sludge floc size in the presence of anionic surfactant. As a model of surfactant linear alkylbenzyne sulphonate (LAS) was used. The granulometric analysis showed that the pure activated sludge was composed of particles with a size of 0,001 to 2 mm. The largest and fastest changes in the distribution...
-
Window frame integrable air recuperation minichannel/minigap heat exchanger
PublikacjaThis article describes an evaluation of mini heat exchangers operation as a decentralized mechanical ventilation system with recuperative heat recovery that can be integrated into the window frame. The relatively small yet efficient air recuperation system allows for retrofitting existing buildings by reducing the overall energy consumption and thus the CO2 emissions. The proposed design, unlike existing systems, is easy to scale...
-
Experimental investigation of heat transfer enhancement in straight and U-bend double-pipe heat exchanger with wire insert
PublikacjaIn this paper, the possibility of heat transfer enhancement in the U-bend exchanger was presented. Experimental research has been carried out for four individual heat exchanger constructions i.e. plain tube in tube, turbulized tube in tube, plain U-bend and U-bend with turbulator. Also, heat transfer experiments for various boundary conditions were performed to obtain reference values. In case of U-bend exchanger with and without...
-
Numerical investigation of the core eccentricity effect on wave propagation in embedded waveguide
PublikacjaThe paper presents results of theoretical and numerical investigation of guided wave propagation in two-layer bars with geometric imperfections in the form of eccentric location of steel core. Steel rod of diameter equal to 1 cm embedded in composite mortar-type cover with external diameter equal to 5 cm has been taken into consideration. Several different rods with variable size of eccentricity are analysed. Results for rods with...
-
Morphometric evaluation of the delayed cerebral arteries response to acetazolamide test in patients with chronic carotid artery stenosis using computed tomography angiography
PublikacjaBackground: The evidence accumulates that the response to acetazolamide test is delayed on the ipsilateral side to stenosis. However, the effect of acetazolamide beyond 30 minutes after acetazolamide administration remains unknown. The aim of this study was to assess the diameters of: anterior cerebral arteries (ACAs), middle cerebral arteries (MCAs) and posterior cerebral arteries (PCAs) before and 60 minutes after the acetazolamide...
-
Thermal and economic investigation of straight and U-bend double tube heat exchanger with coiled wire turbulator
PublikacjaExperimental research has been carried out for four individual heat exchanger constructions, i.e., plain double tube, turbulized double tube, plain U-bend and U-bend with turbulator. Tests were made for the water-water system. The study covered a wide measuring range, i.e., Re = 800–9000 – on the shell side, for a constant cold water temperature of 9 ◦C and hot water of 50 ◦C. The heat exchangers were made from copper tubes with...