Filters
total: 6051
filtered: 833
-
Catalog
Chosen catalog filters
Search results for: short-range order
-
Linear impedance of V2O5 nanorods obtained at 923K
Open Research DataThe DataSet contains the linear electrical properties of V2O5 nanorods which were measured by the impedance spectroscopy method. V2O5 nanorods were obtained by the sol-gel method. The information about xerogel powder synthesis is described in the Journal of Nanomaterials. The precursor powder was pressed into the disk-shaped pellets (12mm in diameter...
-
Equilibrium constants (Keq) of reforming reactions
Open Research DataThe equilibrium constants (K) of reforming reactions in SOFC were supplied with this dataset
-
Optical properties of MnO-B2O3 based glass
Open Research DataMnO-B2O3 based glass with Au nanoparticles samples were annealing for a various time (in a range of 24-96 hours) at various temperatures (from 340 up to 350 deg.). Presence of silver nanoparticles was detected by UV-VIS measurements. On the basis of change optical bandgap, Ag NPs was detected.
-
Scanning Electrone Microscope images of biochar produced from straw and wood chips
Open Research DataThis dataset contains scanning electron microscope images of two types of biochars derived from waste plant biomass: straw and wood chips. Imaging was performed using a scanning electron microscope, FEI Quanta FEG250. with a SE-ETD detector (secondary electron – Everhart-Thornley detector), using 20 kV accelerating voltage.
-
Powder x-ray diffraction pattern of polycrystalline Cu(IO3)2*xH2O
Open Research DataHydrated copper(II) iodate sample was prepared in water solution by reacting copper(II) sulfate and potassium iodate, following the method described by Peterson (J. Chem. Educ. 1957, 34, 12, 612). The sample was subsequently dried at various temperatures in order to produce an anhydrous Cu(IO3)2:
-
Morse decompositions for a population model with harvesting. Case Ha-Se: Harvesting adults only, equal survival rates of juveniles and adults
Open Research DataThis dataset contains selected results of rigorous numerical computations conducted in the framework of the research described in the paper "Global dynamics in a stage-structured discrete population model with harvesting" by E. Liz and P. Pilarczyk: Journal of Theoretical Biology, Vol. 297 (2012), pp. 148–165, doi: 10.1016/j.jtbi.2011.12.012.
-
Morse decompositions for a population model with harvesting. Case He-S1: Equal harvesting of juveniles and adults, survival rates of juveniles and adults add up to 1
Open Research DataThis dataset contains selected results of rigorous numerical computations conducted in the framework of the research described in the paper "Global dynamics in a stage-structured discrete population model with harvesting" by E. Liz and P. Pilarczyk: Journal of Theoretical Biology, Vol. 297 (2012), pp. 148–165, doi: 10.1016/j.jtbi.2011.12.012.
-
Morse decompositions for a population model with harvesting. Case Ha-S1: Harvesting adults only, survival rates of juveniles and adults add up to 1
Open Research DataThis dataset contains selected results of rigorous numerical computations conducted in the framework of the research described in the paper "Global dynamics in a stage-structured discrete population model with harvesting" by E. Liz and P. Pilarczyk: Journal of Theoretical Biology, Vol. 297 (2012), pp. 148–165, doi: 10.1016/j.jtbi.2011.12.012.
-
Morse decompositions for a population model with harvesting. Case He-Se: Equal harvesting and equal survival rates of juveniles and adults
Open Research DataThis dataset contains selected results of rigorous numerical computations conducted in the framework of the research described in the paper "Global dynamics in a stage-structured discrete population model with harvesting" by E. Liz and P. Pilarczyk: Journal of Theoretical Biology, Vol. 297 (2012), pp. 148–165, doi: 10.1016/j.jtbi.2011.12.012.
-
Morse decompositions for a population model with harvesting. Case Hj-Se: Harvesting juveniles only, equal survival rates of juveniles and adults
Open Research DataThis dataset contains selected results of rigorous numerical computations conducted in the framework of the research described in the paper "Global dynamics in a stage-structured discrete population model with harvesting" by E. Liz and P. Pilarczyk: Journal of Theoretical Biology, Vol. 297 (2012), pp. 148–165, doi: 10.1016/j.jtbi.2011.12.012.
-
Morse decompositions for a population model with harvesting. Case Hj-S1: Harvesting juveniles only, survival rates of juveniles and adults add up to 1
Open Research DataThis dataset contains selected results of rigorous numerical computations conducted in the framework of the research described in the paper "Global dynamics in a stage-structured discrete population model with harvesting" by E. Liz and P. Pilarczyk: Journal of Theoretical Biology, Vol. 297 (2012), pp. 148–165, doi: 10.1016/j.jtbi.2011.12.012.
-
Electrical properties of silicate-lead glasses containing nanostructures of iron oxides.
Open Research DataElectrical properties of silicate-lead glasses doped with different content of iron oxide was studied. The set of glass samples were prepared with the composition of (50 − 0.5x)SiO2–(50 − 0.5x)PbO–xFe2O3, where x = 2, 5, 10, 15, 20 and 25 (in mol%). All sampleswere prepared by the conventional melt quenching technique; the melting was conducted in...
-
Linear impedance of strontium–borate glass measured with impedance spectroscopy method at high temperature region
Open Research DataThe linear electrcial properties of strontium–borate glass was measured by impedance spectroscopy method.
-
Linear impedance of 1SiO2–99(40Na2O-20CaO-40P2O5) glass measured with impedance spectroscopy method at low temperature region
Open Research DataThe linear electrical properties of 1SiO2–99(40Na2O-20CaO-40P2O5) glass was measured by impedance spectroscopy method.
-
Euilibrium composition of CH4-CO2-CO-H2-H2O-C system under biogas reforming conditions
Open Research DataThe equilibrium compositions of CH4, CO2, CO, H2, H2O and C under the biogas mixture reforming were supplied with this dataset
-
Series resistance (at 800 °C - 500 °C) of the Sr0.86Ti0.65Fe0.35O3 porous oxygen electrodes sintered at different temperatures
Open Research DataIn this dataset are presented results of the ohmic contribution of differently sintered Sr0.86Ti0.65Fe0.35O3 porous oxygen electrodes in symetrical cell. Applied sintering temperatures were 900 °C, 950 °C, 1000 °C and 1050 °C. The measurement temperature range was between 800 °C and 500 °C in stationary air. Results converted to electrode surfaces area.
-
Temperature of formation of Au nanostructures
Open Research DataNanostructures were obtained via annealing of thin Au films. In order to determine possible nanoislands formation mechanisms, dependence on initial film thickness was examined. For the surface morphology studies, nanograin structure and chemical composition analysis, SEM, HR TEM and EDS measurements were performed, respectively. Morphology studies shown...
-
Area specific resistance (at 800 °C - 500 °C) of the Sr0.86Ti0.65Fe0.35O3 porous oxygen electrodes sintered at different temperatures
Open Research DataIn this dataset are presented results of the polarization resistance of differently sintered Sr0.86Ti0.65Fe0.35O3 porous oxygen electrodes in symetrical cell. Applied sintering temperatures were 900 °C, 950 °C, 1000 °C and 1050 °C. The measurement temperature range was between 800 °C and 500 °C in stationary air. Results converted to electrode surfaces...
-
Optical transmission of the Niobium thin films
Open Research DataNiobium thin films with a thickness of 200nm were deposited n a Corning glass substrate by magnetron sputtering method. The optical transmission spectra in a visible light range were.recorded. Investigations showed a good optical transmission thru the layers for each samples, annealed at various temperatures. For measurements samples annealed at 500,...
-
Electrical properties of lead-borate glasses and glass-ceramics containing iron ions
Open Research DataElectrical properties were studied for borate-lead glasses and glass-ceramics doped with iron ions. Glass samples of composition of xFe2O3–(100 − x)(B2O3–2PbO) (2.5 b x b 37, in mol%) were prepared by the conventional melt quenching technique. The melting was conducted in alumina crucibles at the temperature of 1523 K. The melts were poured on a preheated...
-
Dielectric properties of barium-vanadate glasses
Open Research DataThe linear impedance of barium-vanadate glasses was measured. Samples of the composition of xBaO-(100-x)V2O5 where x= 30, 40 and 45 (in %mol) were prepared by the conventional melt quenching technique. Appropriate amounts of reagents: BaO (≥99.9%, P.P.H STANLAB Sp.J.) and V2O5 (≥99.9%, POCH) were thoroughly mixed in an agate mortar. The melting was...
-
Linear impedance of vanadate glass-ceramics containing BaTiO3
Open Research DataThe linear impedance of vanadate glass-ceramics containing BaTiO3 was measured. Samples of the composition of x[BaO,TiO2]–(80 − x)V2O5–20Bi2O3 where x = 5, 10 and 15 in mol% were prepared by a conventional melt quenching technique. The melting was performed in alumina crucibles at the temperature of 1273 K–1373 K. The melts were poured on a preheated...
-
Linear impedance of 58(2Bi2O3-V2O5)-42SrB4O7 glass measured with impedance spectroscopy method at low temperature region
Open Research DataThe linear electrcial properties of 58(2Bi2O3-V2O5)-42SrB4O7 glass was measured by impedance spectroscopy method.
-
Linear impedance of 5(2Bi2O3-V2O5)-95SrB4O7 glass measured with impedance spectroscopy method at low temperature region
Open Research DataThe linear electrcial properties of 5(2Bi2O3-V2O5)-95SrB4O7 glass was measured by impedance spectroscopy method.
-
Linear impedance of 50(2Bi2O3-V2O5)-50SrB4O7 glass measured with impedance spectroscopy method at low temperature region
Open Research DataThe linear electrcial properties of 50(2Bi2O3-V2O5)-50SrB4O7 glass was measured by impedance spectroscopy method.
-
Linear impedance as a function of A.C. voltage for 50(2Bi2O3-V2O5)-50SrB4O7 glass measured with impedance spectroscopy method
Open Research DataThe linear electrcial properties as a function of A.C. voltage for 50(2Bi2O3-V2O5)-50SrB4O7 glass was measured by impedance spectroscopy method.
-
Series resistance (at 800 °C - 500 °C) of the SrTi0.50Fe0.50O3 porous oxygen electrodes sintered at different temperatures
Open Research DataIn this dataset are presented results of the ohmic contribution of differently sintered Sr0Ti0.50Fe0.50O3 porous oxygen electrodes in symetrical cell. Applied sintering temperatures were 900 °C, 950 °C and 1000 °C. The measurement temperature range was between 800 °C and 500 °C with synthetic ari flow (21% O2, 40 ml min-1). Results converted to electrode...
-
Determination of changes in viscosity of high-fructose syrup stability of pectin hydrogels depending on the temperature (25-96 Celsius degrees).
Open Research DataThe rheological characteristics of the high-fructose syrup modified stability of pectin (added in a concentration 2% m/m) were made on the basis of the viscosity assessment using a Brookfield viscometer with an LV SC4 - 25 spindle and a shear rate of 0,22 s-1 in the temperature range 25-96 ° C. The data allowed selection of optimal conditions for the...
-
Series resistance (at 800 °C - 500 °C) of the SrTi0.30Fe0.70O3 porous oxygen electrodes sintered at different temperatures
Open Research DataIn this dataset are presented results of the ohmic contribution of differently sintered Sr0Ti0.30Fe0.70O3 porous oxygen electrodes in symetrical cell. Applied sintering temperatures were 900 °C, 950 °C and 1000 °C. The measurement temperature range was between 800 °C and 500 °C with synthetic ari flow (21% O2, 40 ml min-1). Results converted to electrode...
-
Series resistance (at 800 °C - 500 °C) of the SrTi0.65Fe0.35O3 porous oxygen electrodes sintered at different temperatures
Open Research DataIn this dataset are presented results of the ohmic contribution of differently sintered Sr0Ti0.65Fe0.35O3 porous oxygen electrodes in symetrical cell. Applied sintering temperatures were 900 °C, 950 °C and 1000 °C. The measurement temperature range was between 800 °C and 500 °C with synthetic ari flow (21% O2, 40 ml min-1). Results converted to electrode...
-
Euilibrium composition of CH4-CO2-CO-H2-H2O-C system for CO2/H2/H2O methanation
Open Research DataThe equilibrium compositions of CH4, CO2, CO, H2, H2O and C under the methanation reaction of 1:2 CO:H2 syngas mixtures were supplied with this dataset
-
ECG measurement from the hand with standing - hands resting on the device - Woman 27 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows in the air - Woman 27 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the table top - Man 29 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 27 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 49 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with standing - hands resting on the device - Man 29 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the table top - Woman 27 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows in the air - Man 29 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows to the body - Man 29 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows to the body - Woman 27 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with standing - hands resting on the device - Woman 49 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows to the body - Woman 49 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the armrests of the chair - Man 29 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the table top - Woman 49 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows in the air - Woman 49 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with standing - hands resting on the device - Man 30 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows to the body - Man 53 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows in the air - Woman 30 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows resting on the armrests of the chair - Man 30 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...