displaying 1000 best results Help
Search results for: FAULT LOOP IMPEDANCE
-
Impedance characterization of the process of polyaniline first redox transformation after aniline electropolymerization
Publication -
Use of impedance spectroscopy to evaluate the durability of protective coatings after thermal shock
Publication -
Influence of the analyzing window on electrode impedance measurement by the continuous frequency scanning method
Publication -
Impedance monitoring of carbon steel cavitation erosion under the influence of corrosive factors
PublicationW pracy przedstawiono wyniki badań degradacji stali węglowych na skutek oddziaływania erozji-korozji kawitacyjnej. Do analizy wykorzystano technikę Dynamicznej Elektrochemicznej Spektroskopii Impedancyjnej oraz funkcję ubytku masy powszechnie stosowaną do oceny odporności kawitacyjnej materiałów. Oszacowanie stopnia degradacji powierzchni, a także wpływu erozji na odporność korozyjną jest możliwe po zastosowaniu odpowiedniego elektrycznego...
-
Influence of the analyzing window on electrode impedance measurement by thecontinuous freqency scanning method
PublicationPrzeprowadzono pomiary impedancyjne modelowego układu elektrycznego RC techniką ciągłego skanowania częstotliwościowego. Wyznaczono impedancję modelowego układu dla różnych okien analizujących oraz ich różnych wielkości. Wyznaczone dla różnych okien analizujących wartości R i C porównywano z wartościami rzeczywistymi. Stwierdzono wpływ rodzaju okna analizującego oraz jego długość na dokładność otrzymywanych wyników.
-
Design of quarter-wave compact impedance transformers using coupled transmission lines
PublicationPrzedstawiono porównanie wyników symulacji jedno i wielosekcyjnych transformatorów impedancji budowanych w postaci struktur wykorzystujących idealnenie sprzężone linie transmisyjne, idealne sprzężone symetryczne linie transmisyjne oraz rzeczywiste sprzężone linie mikropaskowe. Pokazano, że możliwa jest konstrukcja transformatorów impedancji o bardzo dobrych parametrach technicznych wykorzystująca sprzężone linie mikropaskowe, pomimo...
-
Impedance investigation of passive 304 stainless steel in the pit pre-initiation state
PublicationZaprezentowano wyniki badań impedancyjnych stali stopowej 304L metodą klasycznej EIS i dynamicznej EIS. Badania związane były z przejściem stali stopowej ze stanu pasywnego do inicjacji powstawania wżerów. Na podstawie zmian parametrów elektrycznego schematu zastępczego stwierdzono, że najbardziej prawdopodobnym mechanizmem tworzenia się wżerów jest model zniszczenia (pęknięcia) warstwy pasywnej.
-
Accelerated impedance spectrum measurement via multisine perturbationand digital filter banks
PublicationPrzedstawiono przyspieszoną metodę pomiaru widma impedancyjnego, zorientowaną na pomiary jakości powłok przeciwkorozyjnych, modelowanych liniowymi obwodami zastępczymi. Metoda polega na pobudzeniu układu wielosinusoidalnym sygnałem popudzającym oraz analizie pobudzenia i odpowiedzi obiektu przez bank filtrów cyfrowych. Przedstawiono podstawy teoretyczne metody oraz propozycję metodologii pomiaru. Przeanalizowano wyniki symulacji...
-
Virtual instrument using bilinear transformation for parameter identification of high impedance objects.
PublicationArtykuł przedstawia przyrząd wirtualny do pomiaru parametrów obiektów wysokoimpedancyjnych (/Zx/<10GOhm). Opracowano metodę identyfikacji elementów składowych dwójników wieloelementowych opartą na przekształceniu biliniowym.Metoda jest predestynowana do identyfikacji parametrów różnych powłok antykorozyjnych. Dla identyfikacji konieczne są wektorowe pomiary impedancji obiektu na kilku wybranych częstotliwościach, których liczba...
-
Comparison of corrosion resistance of al-alloys by means of dynamic electrochemical impedance spectroscopy
PublicationPrzeprowadzono badania metodą dynamicznej elektrochemicznej spektroskopii impedancyjne stopów 1100 i 5162. Zaproponowano zastępcze modele elektryczne opisujące zachowanie się stopów w warunkach ekspozycji w roztworach zawierających wysokie stężenie jonów chlorkowych. Wyznaczono zmiany podstawowych parametrów elektrycznych układów zastępczych od potencjału. Stwierdzono wyższą podatność na korozję stopu 5162 w porównaniu ze stopem...
-
Method using square-pulse excitation for high-impedance spectroscopy of anticorrosion coatings
PublicationArtykuł prezentuje metodę spektroskopii impedancyjnej przeznaczonej do diagnostyki powłok antykorozyjnych na obiektach bezpośrednio w terenie. Aby skrócić czas uzyskania widma impedancji (w zakresie od 1 mHz do 1 MHz) do kilku minut, wykorzystano sygnały harmoniczne do pomiaru widma powyżej 10 Hz a impuls prostokątny w dolnym zakresie częstotliwości. Do wyznaczania widma użyto algorytmów DSP odpowiednich do sygnału pobudzenia....
-
Interface circuit for impedance sensors using two specialized single-chip microsystems
PublicationW artykule przedstawiono obwód interfejsu przeznaczony do pomiaru parametrów impedancyjnych czujników lub celek pomiarowych instalowanych na obiektach technicznych. Umożliwia on pomiar modułu i argumentu impedancji w zakresie 10ohm
-
Application of Electrochemical Impedance Spectroscopy to evaluate cathodically protected coated steel in seawater
PublicationTwo types of organic coated carbon steel (S235JR2 grade) electrodes were exposed to artificial seawater environment. One prepared type was defect free while the other one had an intentionally introduced φ0,5 cm coating defect. Both kinds of samples were polarized during the exposure to four potentials corresponding to four different cathodic protection levels. Evolution of their EIS spectra is presented in this paper. Results obtained...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on Baunier's RC model using 3 wire probe
Open Research DataThe dataset presents impedance spectrum of Baunier's RC model. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (1 mHz – 100 kHz) was selected in order to test the whole measureement range of the analyzer. In...
-
Nonlinear high temperature impedance of 35P2O5-30Fe2O3-35Nb2O5 glass
Open Research DataThe nonlinear high temperature impedance of iron- phosphate glasses doped with niobium oxide was measured. Glass samples of the composition of 35P2O5-30Fe2O3-35Nb2O5 (in %mol) were prepared by the conventional melt quenching technique. Appropriate amounts of reagents ((NH4)2HPO4 (≥99.9%, POCH), Fe2O3 (≥99.9%, POCH) and Nb2O5 (≥99.9%, PLUKA AG) were...
-
Nonlinear impedance of 50(2Bi2O3-V2O5)-50SrB4O7 glass heat treated at 693 K measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrcial properties of 50(2Bi2O3-V2O5)-50SrB4O7 glass heat treated at 693 K was measured by impedance spectroscopy method.
-
Nonlinear impedance of 50(2Bi2O3-V2O5)-50SrB4O7 glass heat treated two times measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrcial properties of 50(2Bi2O3-V2O5)-50SrB4O7 glass heat treated two times was measured by impedance spectroscopy method.
-
Nonlinear impedance as a function of A.C. voltage for fully crystallized 35Bi2VO5.5-65SrB4O7 glass measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrcial properties as a function of A.C. voltage for fully crystallized 35Bi2VO5.5-65SrB4O7 glass was measured by impedance spectroscopy method.
-
Nonlinear impedance of 40Bi2VO5.5-60SrB4O7 annealed glass at 473 K for 3 h measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrical properties of 40Bi2VO5.5-60SrB4O7 glass annealed at 473 K for 3h was measured by impedance spectroscopy method.
-
Nonlinear impedance as a function of A.C. voltage for fully crystallized 45Bi2VO5.5-55SrB4O7 glass measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrcial properties as a function of A.C. voltage for fully crystallized 45Bi2VO5.5-55SrB4O7 glass was measured by impedance spectroscopy method.
-
The electrochemical impedance spectroscopy studies of cataphoretic-grown epoxy-based coatings
Open Research DataThe dataset contains electrochemical impedance spectroscopy spectra collected for epoxy-based cataphoretic coatings in order to determine the offered anti-corrosion protection. Particular spectra pertain to the coatings applied for the different magnitude of polarization potential imposed, namely 10V, 20V and 30V. The results were obtained within the...
-
Nonlinear impedance of 50(2Bi2O3-V2O5)-50SrB4O7 glass-ceramic heat-treated at 813 K measured with impedance spectroscopy method at high temperature region
Open Research DataNonlinear electrcial properties of 50(2Bi2O3-V2O5)-50SrB4O7 glass-ceramic heat treated at 813 K was measured by impedance spectroscopy method.
-
Linear impedance of 50(2Bi2O3-V2O5)-50SrB4O7 glass-ceramic heat-treated at 613 K measured with impedance spectroscopy method at high temperature region
Open Research DataThe linear electrcial properties of 50(2Bi2O3-V2O5)-50SrB4O7 glass-ceramic heat-treated at 613 K was measured by impedance spectroscopy method.
-
Linear impedance of 35P2O5-30Fe2O3-35Nb2O5
Open Research DataThe electrical properties of phosphate-iron glasses containing niobium were investigated. Glass samples of the composition of 35P2O5-30Fe2O3-35Nb2O5 (in %mol) were prepared by the conventional melt quenching technique. Appropriate amounts of reagents ((NH4)2HPO4 (≥99.9%, POCH), Fe2O3 (≥99.9%, POCH), Nb2O5 (≥99.9%, PLUKA AG) and TiO2 (≥99.9%, anatase...
-
Electrochemical impedance spectra and CV curves of V2O5 nanocrystals
Open Research DataThe DataSet contains the EIS spectra for coin-cells and CV curves with the V2O5 nanocrystals obtained by the sol-gel method. Cyclic voltammetry and electrochemical impedance spectroscopy (EIS) were measured using the AUTOLAB 302N potentiostat-galvanostat under Nova software. The EIS measurements were recorded in the frequency range 100 kHz to 10 mHz...
-
Electrochemical impedance spectra and CV curves of V2O5 nanorods
Open Research DataThe DataSet contains the EIS spectra for coin-cells and CV curves with the V2O5 nanorods obtained by the sol-gel method. Cyclic voltammetry and electrochemical impedance spectroscopy (EIS) were measured using the AUTOLAB 302N potentiostat-galvanostat under Nova software. The EIS measurements were recorded in the frequency range 100 kHz to 10 mHz for...
-
Linear impedance of 58(2Bi2O3-V2O5)-42SrB4O7 glass heat-treated for 3 hours at 693 K, measured with impedance spectroscopy method at low temperature region
Open Research DataThe linear electrcial properties of partially crystallized 58(2Bi2O3-V2O5)-42SrB4O7 glass was measured by impedance spectroscopy method.
-
Linear impedance of 58(2Bi2O3-V2O5)-42SrB4O7 glass heat-treated for 10 hours at 693 K, measured with impedance spectroscopy method at low temperature region
Open Research DataThe linear electrcial properties of partially crystallized 58(2Bi2O3-V2O5)-42SrB4O7 glass was measured by impedance spectroscopy method.
-
Linear impedance as a function of A.C. voltage for 50(2Bi2O3-V2O5)-50SrB4O7 glass heat treated at 693 K measured with impedance spectroscopy method at 273 K
Open Research DataThe linear electrcial properties as a function of A.C. voltage for 50(2Bi2O3-V2O5)-50SrB4O7 glass heat treated at 693 K was measured by impedance spectroscopy method.
-
Nonlinear impedance of 50(2Bi2O3-V2O5)-50SrB4O7 glass-ceramic heat-treated at 613 K measured with impedance spectroscopy method at high temperature region
Open Research DataNonlinear electrcial properties of 50(2Bi2O3-V2O5)-50SrB4O7 glass-ceramic heat treated at 613 K was measured by impedance spectroscopy method.
-
Design, Chemical Synthesis and Kinetic Studies of Trypsin Chromogenic Substrates Based on the Proteinase Binding Loop of Cucurbita maxima Trypsin Inhibitor (CMTI-III)
Publication -
Nonlinear impedance of glass 40Bi2VO5.5-60SrB4O7 annealed at 593 K and next fully crystallized was measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrcial properties of glass 40Bi2VO5.5-60SrB4O7 annealed at 593 K and next fully crystallized was measured by impedance spectroscopy method.
-
Nonlinear impedance of 58(2Bi2O3-V2O5)-42SrB4O7 glass heat-treated for 3 hours at 693 K, measured with impedance spectroscopy method at low temperature region
Open Research DataThe nonlinear electrcial properties of partially crystallized 58(2Bi2O3-V2O5)-42SrB4O7 glass was measured by impedance spectroscopy method.
-
Nonlinear impedance of 58(2Bi2O3-V2O5)-42SrB4O7 glass heat-treated for 10 hours at 693 K, measured with impedance spectroscopy method at low temperature region
Open Research DataThe nonlinear electrcial properties of partially crystallized 58(2Bi2O3-V2O5)-42SrB4O7 glass was measured by impedance spectroscopy method.
-
Dynamic impedance data for various carboxylic acids corrosion inhibition of aluminium in alkaline media (pH=11)
Open Research DataThis dataset contains the results of Dynamic Electrochemical Impedance Spectroscopy (DEIS) carried out in galvanostatic mode under iDC=0, carried out in order to define the corrosion inhibition effect of various studied carboxylic acids: citric acid, malic acid, maleic acid, succinic acid, tartaric acid, carballylic acid, and serine. The experiment...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on protective foil using 2-wire probe 24h exposition
Open Research DataThe dataset presents impedance spectrum of anticorrosion foil (coating) protecting aluminium frame . This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on protective foil using 2-wire probe 48h exposition
Open Research DataThe dataset presents impedance spectrum of anticorrosion foil (coating) protecting aluminium frame . This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole...
-
Michał Grochowski dr hab. inż.
PeopleProfessor and a Head of the Department of Intelligent Control and Decision Support Systems at Gdansk University of Technology (GUT). He is also a Member of the Board of the Digital Technologies Center of GUT. He received his M.Sc. degree in Control Engineering in 2000 from the Electrical and Control Engineering Faculty at the GUT. In 2004 he received a Ph.D. degree in Automatic Control and Robotics from this...
-
Linear and nonlinear impedance of alkali and iron doped silicate-lead glasses
Open Research DataLinear and nonlinear impedance was studied for lead-silicate glass samples doped with iron ions and alkaline oxides. The compositions of glasses were as follows: (in %mol) 50% SiO2, 25% PbO, 15% Fe2O3 and 15% one of alkaline oxides: Na2O, K2O, Li2O. All samples were prepared by the conventional melt quenching technique. The substrates were powdered...
-
Nonlinear impedance of Bi2VO5.5 ceramic of thickness 2.52 mm (after second heat-treatment at 913 K) was measured at high temperature range with impedance spectroscopy method
Open Research DataThe nonlinear electrical properties of Bi2VO5.5 ceramic of thickness 2.52 mm (after second heat-treatment at 913 K) was measured by impedance spectroscopy method.
-
Implementation and Validation of Multisinusoidal, Fast Impedance Measurements in Atomic Force Microscope Contact Mode
Publication -
Corrosion resistance evaluation of Al‐based alloys by means of dynamic electrochemical impedance spectroscopy
Publication -
Application of electrochemical impedance spectroscopy to monitoring discharging process of nickel/metal hydride battery
Publication -
Use of Impedance Spectroscopy to Characterize Lining Performance in Simulated Flue Gas Desulfurization Systems
Publication -
Method using bilinear transformation for measurement of impedance parameters of a multielement two-terminal network
PublicationArtykuł przedstawia metodę identyfikacji parametrów impedancyjnych obiektów modelowanych dwójnikami. Metoda wykorzystuje właściwości przekształcenia biliniowego pozwalającego na przedstawienie impedancji obiektu jako funkcji każdego z parametrów obwodu zastępczego z osobna. Odwrotne przekształcenie biliniowe pozwala na wyznaczenie wartości każdego parametru na podstawie pomiaru impedancji na jednej częstotliwości dobranej dla...
-
Corrosion resistance evaluation of Al-based alloys by means of dynamic electrochemical impedance spectroscopy
PublicationW pracy przedstawiono wyniki badań stopów aluminium wykonane za pomocą dynamicznej elektrochemicznej spektroskopii. Na podstawie uzyskanych widm impedancyjnych zostały pokazane zmiany parametrów elektrycznego schematu zastępczego z potencjałem. Stwierdzono, że dodatek magnezu do badanego stopu obniża właściwości przeciwkorozyjne stopu.
-
Localized impedance measurements of AA2024 and AA2024‐T3 performed by means of AFM in contact mode
Publication -
Instantaneous impedance evaluation of dissolution of aisi 304 stainless steel during intergranular corrosion
PublicationCelem pracy było uzyskanie informacji dotyczących zróżnicowania parametrów elektrycznych uzyskanych na podstawie zarejestrowanych chwilowych widm impedancyjnych w zakresie aktywacji i reaktywacji roztwarzania wysokostopowej stali austenitycznej AISI podczas postępującego procesu korozji międzykrystalicznej. Badania prowadzono z wykorzystaniem dynamicznej elektrochemicznej spektroskopii impedancyjnej (DEIS). Pomiary wykonywano ''on-line''...
-
Impedance of cation-coupled electron transfer reaction: teoretical description of one pathway process
PublicationPrzyjęto możliwość występowanie dwóch wzajemnie sprzężonych reakcji. Opisana została impedancja sprzężonej reakcji przeniesienia elektronu z kationem. Wyznaczony został również model elektrycznego schematu zastępczego. Całkowita impedancja Faradayowska jest sumą impedancji przeniesienia elektronu i impedancji przeniesienia kationu. Przykłady pomiaru impedancyjnego w warunkach potencjostatycznych i potencjodynamicznych zostały omówione....
-
Cyclic analysis of thermal impedance of a passive layer of aluminium in a neutral borate buffer solution
PublicationW pracy przedstawiono wyniki badań warstwy pasywnej tworzącej się na stopie 1050 A w warunkach zmieniającej się temperatury. Zmiany realizowano w sposób cykliczny zwiększając a następnie zmniejszając temperaturę. W czasie zmian temperatury prowadzono badania metodę dynamicznej elektrochemicznej spektroskopii impedancyjnej. Stwierdzono największe zmiany parametrów elektrycznego schematu zastępczego w czasie pierwszego cyklu zmian....