displaying 1000 best results Help
Search results for: MULTIPLE CURVE RESOLUTION
-
Effect of GIS parameters on modelling runoff from river basin. The case study of catchment in the Puck District
PublicationThe study was preceded to check the impact of the adopted digital elevation model resolution on the determination of catchment parameters and the further influence of the received information on calculations related to the hydrograph at the closing point of the basin after a synthetic 100-year precipitation episode. The study area are river basins located in the Puck commune convoying water directly to the Puck Bay. These studies...
-
Abnormal cytological findings - Female, 43 - Cell image [706072959932111]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal cytological findings - Female, 34 - Cell image [5170730007436311]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal cytological findings - Female, 29 - Cell image [517073000743981]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal cytological findings - Female, 28 - Cell image [715072957550801]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Other specified inflammation of vagina and vulva - Female, 34 - Cell image [4080730008366191]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal cytological findings - Female, 36 - Cell image [11300630022654291]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal cytological findings - Female, 32 - Cell image [7140729576848601]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal cytological findings - Female, 30 - Cell image [7140729576842941]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal cytological findings - Female, 28 - Cell image [6110730021446771]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Inflammatory disease of uterus, unspecified - Female, 47 - Cell image [3180630006438691]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Vulvovaginal ulceration and inflammation in other diseases classified elsewhere - Female, 42 - Cell image [6280730027966421]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Candidiasis of vulva and vagina (N77.1*) - Female, 34 - Cell image [3301001549116751]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Inflammatory disease of cervix uteri - Female, 45 - Cell image [4050730010688731]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal cytological findings - Female, 33 - Cell image [5170730007439961]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal cytological findings - Female, 37 - Cell image [4130730006612781]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal cytological findings - Female, 27 - Cell image [6110730021447481]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Diamond surface modification following thermal etching of Si supported hydrogenated diamond films by DBr
PublicationZbadano, wykorzystując spektroskopię oscylacyjną (HREELS - High Resolution Electron Energy Loss Spectroscopy) modyfikacje chemiczne powierzchni wodorowanego diamentu, umieszczonego na podkładzie krzemowym i wystawionego na działanie DBr a następnie podgrzanego do temp. powyżej 600 st.K. Przedstawiona procedura powoduje tworzenie się węglika krzemu SiC na powierzchni warstwy diamentowej, co jest widoczne na widmie HREEL jako dwa...
-
On the preestimation technique and its application to identification of nonstationary systems
PublicationThe problem of noncausal identification of a nonstationary stochastic FIR (finite impulse response) sys- tem is reformulated, and solved, as a problem of smoothing of preestimated parameter trajectories. Three approaches to preestimation are critically analyzed and compared. It is shown that optimization of the smoothing operation can be performed adaptively using the parallel estimation technique. The new approach is computationally...
-
Reply to Comment on ‘Nanodiamond incorporated human liver mimicking phantoms: prospective calibration medium of magnetic resonance imaging’
PublicationDependence of the spin–lattice (T1) relaxation times on the nanodiamond concentration in human liver phantoms is discussed. Factors affecting stability and and reproducibility of these phantoms are presented. The need for comparative measurements on multiple MRI scanners for better understanding of potential variations in the obtained imaging data is emphasised.
-
A Novel Versatile Decoupling Structure and Expedited Inverse-Model-Based Re-Design Procedure for Compact Single-and Dual-Band MIMO Antennas
PublicationMultiple-input multiple-output (MIMO) antennas are considered to be the key components of fifth generation (5G) mobile communications. One of the challenges pertinent to the design of highly integrated MIMO structures is to minimize the mutual coupling among the antenna elements. The latter arises from two sources, the coupling in the free space and the coupling currents propagating on a ground plane. In this paper, an array of...
-
Adam Inglot dr inż.
PeopleAdam Inglot (born October 3, 1984), studied Environmental Engineering and Geodesy and Cartography at the Faculty of Mine Surveying and Environmental Engineering of AGH University of Science and Technology in Krakow. He graduated in 2011 as a M.Sc. in Environmental Engineering, defending his thesis "Verification of usefulness of GeoMod model for prediction of the urbanization process in Cracow agglomeration" under the guidance of...
-
Analysis of the influence of external conditions on temperature readings in thermograms and adaptive adjustment of the measured temperature value
PublicationMeasuring human temperature is a crucial step in preventing the spread of diseases such as COVID-19. For the proper operation of an automatic body temperature measurement system throughout the year, it is necessary to consider outdoor conditions. In this paper, the effect of atmospheric factors on facial temperature readings using infrared thermography is investigated. A thorough analysis of the variation of facial temperature...
-
Modeling variable curvature on the turnout diverging track length
PublicationThe paper presents three variants of variable curvature application on the entire length of the turnout diverging track. One linear and two nonlinear curvature cases: described the function of C1 and C0 class were considered. It turned out that both linear curve and the function of C1 class requires a significant (even twice) length of diverging track extending with respect to the base turnout. The curvature described by the function...
-
Research into flows in turbine blade seals. Part II: Numerical analysis
PublicationPrzedstawiono wyniki badań numerycznych programem Fluent przepływów w uszczelnieniu nadbandażowym stopnia turbinowego. Badania wykonano przy zastosowaniu różnych typów siatek obliczeniowych, różnych rodzajów "zszywek" oraz różnych metod obliczeniowych (Mixing Plane, Sliding Mesh, Multiple ReferenceFrame).
-
Improving the Survivability of Carrier Networks to Large-Scale Disasters
PublicationThis chapter is dedicated to the description of methods aiming to improve the survivability of carrier networks to large-scale disasters. First, a disaster classification and associated risk analysis is described, and the disaster-aware submarine fibre-optic cable deployment is addressed aiming to minimize the expected costs in case of natural disasters. Then, the chapter addresses the improvement of the network connectivity resilience...
-
Stanisław Barański
PeopleStanisław Barański received BSc in 2019 and MSc in 2020 in informatics at Gdańsk University of Technology. Currently, he is a PhD candidate at the Department of Computer Architecture, Faculty of Electronics, Telecommunications and Informatics, Gdansk University of Technology. His research interests include blockchains and cryptography, especially the issue of blockchain-based internet voting and mitigation of content poisoning...
-
Analiza doświadczalna wpływu długości zakotwienia pręta na zachowanie przyczepności w teście pull-out
PublicationArtykuł prezentuje badania przyczepności przeprowadzone przy użyciu testu pull-out. Eksperymenty miały na celu ocenę wpływu długości zakotwienia na przyczepność w tym teście. Z przeprowadzonej analizy wynika, że długość styku pręt-beton znacząco wpływa na zachowanie przyczepności. Określa ona typ zniszczenia połączenia, wpływa na rozkład i wartość naprężeń w pręcie oraz rzutuje na przebieg krzywej przyczepność-poślizg, która jest...
-
Shoreline Extraction Based on LiDAR Data Obtained Using an USV
PublicationThis article explores the use of Light Detection And Ranging (LiDAR) derived point clouds to extract the shoreline of the Lake Kłodno (Poland), based on their geometry properties. The data collection was performed using the Velodyne VLP‐16 laser scanner, which was mounted on the HydroDron Unmanned Surface Vehicle (USV). A modified version of the shoreline extraction method proposed by Xu et al. was employed, comprising of the following...
-
Electron-scattering cross sections for selected alkyne molecules: Measurements and calculations
PublicationWe report cross-section results from experimental and theoretical studies on electron collisions with 1-butyne (HC≡C–CH2CH3) and acetylene (HC≡CH) molecules and from computations for a propyne (HC≡C–CH3) molecule. Absolute grand -total electron-scattering cross sections (TCSs) were measured at impact energies ranging from about 0.5 to 300 eV using the linear electron-transmission method. The TCS energy curve for 1-butyne has a...
-
Metoda i algorytmy modyfikacji sygnału do celu wspomagania rozumienia mowy przez osoby z pogorszoną rozdzielczością czasową słuchu
PublicationPrzedmiotem badań przeprowadzonych w ramach rozprawy są metody modyfikacji czasu trwania sygnału (ang. Time Scale Modification –TSM) mowy operujące w czasie rzeczywistym oraz ocena ich wpływu na rozumienie wypowiedzi przez osoby z pogorszoną rozdzielczością czasową słuchu. Pogorszona rozdzielczość słuchu jest jednym z symptomów związanych z ośrodkowymi zaburzeniami słuchu (ang. Cetnral Auditory Processing Disorder – CAPD). W odróżnieniu...
-
Abnormal cytological findings - Female, 37 - Cell image [4200730008418711]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal cytological findings - Female, 45 - Cell image [7060729599329251]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal cytological findings - Female, 41 - Cell image [5050730010501191]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal cytological findings - Female, 45 - Cell image [4200730008416701]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal cytological findings - Female, 26 - Cell image [6130730026855131]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal cytological findings - Female, 38 - Cell image [7020730007134891]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal cytological findings - Female, 37 - Cell image [4200730008419901]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal cytological findings - Female, 39 - Cell image [4200730008411631]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal cytological findings - Female, 29 - Cell image [4200730008417201]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal cytological findings - Female, 44 - Cell image [6300730028254131]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal cytological findings - Female, 46 - Cell image [50407300202761]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Vulvovaginal ulceration and inflammation in other diseases classified elsewhere - Female, 28 - Cell image [4110730008007941]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal cytological findings - Female, 32 - Cell image [5050730010507471]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Abnormal cytological findings - Female, 37 - Cell image [702073000713991]
Open Research DataThis is the histopathological image of CERVIX UTERI cell sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Photoelectron spectroscopy of brominated derivative of pyrimidine: 2-bromopyrimidine
PublicationIn this study the brominated derivative of pyrimidine, 2-bromopyrimidine, was investigated by photoelectron spectroscopy. Outer valence photoelectron spectra recorded at 21.22, 45 and 100 eV photon energy for this compound are presented. The recorded spectra have a higher resolution than that previously reported in the literature. The bromine 3d and 3p edge photoelectron spectra have also been recorded in a photon impact experiment...
-
PHASE OBJECT OBSERVATION SYSTEM BASED ON DIFFRACTION PHASE MICROSCOPY
PublicationIn the paper authors present a special measurement system for observing phase objects. The diffraction phas microscopy makes it possible to measure the dimensions of a tested object with a nanometre resolution. To meet this requirement, it is proposed to apply a spatial transform. The proposed setup can be based either on a two lenses system (called 4 f ) or a Wollaston prism. Both solutions with all construction aspects are described...
-
A Framework of a Ship Domain-based Collision Alert System
PublicationThe paper presents a framework of a planned ship collision alert system. The envisaged system is compliant with IMO Resolution MSC.252 (83) “Adoption of the revised performance standards for Integrated Navigation Systems (INS)”. It is based on a ship domain-oriented approach to collision risk and introduces a policy of alerts on dangerous situations. The alerts will include cautions, warnings and alarms, which will be triggered...
-
Interferometric Sensor of Wavelength Detuning Using a Liquid Crystalline Polymer Waveplate
PublicationOperation of a polarization interferometer for measurement of the wavelength changes of a tunable semiconductor laser was investigated. A lambda/8 waveplate made from liquid crystalline polymer is placed in one of interferometers’ arms in order to generate two output signals in quadrature. Wavelength was measured with resolution of 2 pm in the wavelength range 628–635 nm. Drift of the interferometer, measured in the period of 500...
-
Exact resultant equilibrium conditions in the non-linear theory of branching and self-intersecting shells
PublicationWe formulate the exact, resultant equilibrium conditions for the non-linear theory of branching and self-intersecting shells. The conditions are derived by performing direct through-the-thickness integration in the global equilibrium conditions of continuum mechanics. At each regular internal and boundary point of the base surface our exact, local equilibrium equations and dynamic boundary conditions are equivalent, as expected,...