ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Woman 24 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Man 53 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Man 30 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Man 30 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Man 53 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Woman 30 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Woman 30 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
Marek Sylwester Tatara dr inż.
PeopleMarek Tatara achieved his master's degree in the field of Automatic Control and Robotics with specialization Intelligent Decision-making Systems in 2014 at Faculty of Electronics, Telecommunications and Informatics of Gdańsk University of Technology. Earlier this year achieved bachelor's degree in the field of Technical Physics with Nanotechnology specialization. In 2014 started job as lecturer in the Department of Robotics and...
-
Suppression of distortions in signals received from Doppler sensor for vehicle speed measurement
PublicationDoppler sensors are commonly used for movement detection and speed measurement. However, electromagnetic interference and imperfections in sensor construction result in degradation of the signal to noise ratio. As a result, detection of signals reflected from moving objects becomes problematic. The paper proposes an algorithm for reduction of distortions and noise in the signal received from a simple, dual-channel type of a Doppler...
-
Generation of large finite-element matrices on multiple graphics processors
PublicationThis paper presents techniques for generating very large finite-element matrices on a multicore workstation equipped with several graphics processing units (GPUs). To overcome the low memory size limitation of the GPUs, and at the same time to accelerate the generation process, we propose to generate the large sparse linear systems arising in finite-element analysis in an iterative manner on several GPUs and to use the graphics...
-
A self-optimization mechanism for generalized adaptive notch smoother
PublicationTracking of nonstationary narrowband signals is often accomplished using algorithms called adaptive notch filters (ANFs). Generalized adaptive notch smoothers (GANSs) extend the concepts of adaptive notch filtering in two directions. Firstly, they are designed to estimate coefficients of nonstationary quasi-periodic systems, rather than signals. Secondly, they employ noncausal processing, which greatly improves their accuracy and...
-
Reduction of parasitic pitch variations in archival musical recordings
PublicationA new method for reducing parasitic pitch variations in archival audio recordings is presented. The method is intended for analyzing movie soundtracks recorded in optical films. It utilizes image processing for calculating and reducing effects of tape shrinkage being one of the main reasons for parasitic pitch variations in audio accompanying moving images. As long as the film tape characteristics are known the new method can be...
-
Matrix-based robust joint fingerprinting and decryption method for multicast distribution of multimedia
PublicationThis paper addresses the problem of unauthorized redistribution of multimedia content by malicious users (pirates). The solution proposed here is a new joint fingerprinting and decryption method which meets the requirements for both imperceptibility and robustness of fingerprints and scalability in terms of design and distribution of fingerprinted multimedia content. The proposed method uses a simple block cipher based on matrix...
-
Karhunen-Loeve-based approach to tracking of rapidly fading wireless communication channels
PublicationWhen parameters of wireless communication channels vary at a fast rate, simple estimation algorithms, such as weighted least squares (WLS) or least mean squares (LMS) algorithms, cannot estimate them with the accuracy needed to secure the reliable operation of the underlying communication systems. In cases like this, the local basis function (LBF) estimation technique can be used instead, significantly increasing the achievable...
-
Reversible data hiding in encrypted DICOM images using sorted binary sequences of pixels
PublicationIn this paper, a novel reversible data hiding method for encrypted DICOM images is proposed. The method utilizes binary decomposition of the input data paired with a sorting process of the obtained binary sequences to ensure efficient data embedding in each predefined data block for specific most significant bit (MSB) planes while exploiting the properties of run-length encoding. The proposed scheme is lossless, and based on the...
-
Finite-window RLS algorithms
PublicationTwo recursive least-squares (RLS) adaptive filtering algorithms are most often used in practice, the exponential and sliding (rectangular) window RLS algorithms. This popularity is mainly due to existence of low-complexity versions of these algorithms. However, these two windows are not always the best choice for identification of fast time-varying systems, when the identification performance is most important. In this paper, we...
-
Software tool for modelling of mechatronic systems with elastic continua
PublicationThe paper presents a systematic computational package for modelling and analysis of complex systems composed of multiple lumped and distributed parameter subsystems. The constructed computer program enables the frequency domain analysis of a class of linear systems and to obtain reduced order model in the form of bond graph. Obtained modal bond graph can be directly exported into 20-Sim package to further processing including nonlinear...
-
Arm EMG Wavelet-Based Denoising System
PublicationThese paper presents research results of muscle EMG signal denoising. In the same time two muscles were examined - an adductor muscle (biceps brachii) and an abductor muscle (tricpeps brachii). The EMG signal was filtered using the wavelet transform technique, having selected the crucial parameters as: wavelet basis function (Daubechies 4), 10 th decomposition level, threshold selection algorithm (Heurestic) and a sln rescaling...
-
Speech codec enhancements utilizing time compression and perceptual coding
PublicationA method for encoding wideband speech signal employing standardized narrowband speech codecs is presented as well as experimental results concerning detection of tonal spectral components. The speech signal sampled with a higher sampling rate than it is suitable for narrowband coding algorithm is compressed in order to decrease the amount of samples. Next, the time-compressed representation of a signal is encoded using a narrowband...
-
Depth Determination Accuracy of the Modified Prony Method in a Swath Mapping Application
PublicationThis article presents the performance of the modified Prony method in a swath mapping application. Depth determination accuracy is assessed by processing raw signal acquired by an EdgeTech 6205 swath bathymetry system over flat seafloor. An updated version of the method, proposed previously by the authors, is used to determine the number of signal echoes. The number of signal echoes is essential for performing the low-rank approximation...
-
New method of IEEE 802.15.4a UWB Impulse Radio Spectrum Shaping
PublicationThis paper presents a new technique of IEEE 802.15.4a ultra-wideband signal spectrum control, based on changes in sequences of transmitted pulses with very short duration time. Basic parameters of UWB signal and outline of proposed spectrum shaping methods are briefly described. The main part of the paper presents influence of signal and algorithms parameters on the results of spectrum shaping.
-
Transient detection for speech coding applications
PublicationSignal quality in speech codecs may be improved by selecting transients from speech signal and encoding them using a suitable method. This paper presents an algorithm for transient detection in speech signal. This algorithm operates in several frequency bands. Transient detection functions are calculated from energy measured in short frames of the signal. The final selection of transient frames is based on results of detection...
-
Electrical responses of nanostructured ZrS3 as field-effect transistor for nitrogen dioxide, ethanol, and acetone detection enhanced by visible light
Open Research DataSmall-area layers of nanostructured ZrS3 were fabricated and measured in the field-effect transistor configuration. Irradiation with visible light enabled generating photocurrent and increasing the sensitivity to selected ambient gases: nitrogen dioxide, ethanol, and acetone. The data set consists of electrical responses (current vs. voltage characteristics...
-
Cloning, expression in Komagataella phaffii, and biochemical characterization of recombinant sequence variants of Pseudomonas sp. S9 GDSL-esterase
PublicationTwo recombinant Komagataella phaffii (formerly Pichia pastoris) yeast strains for production of two sequential variants of EstS9 esterase from psychrotolerant bacterium Pseudomonas sp. S9, i.e. αEstS9N (a two-domain enzyme consisting of a catalytic domain and an autotransporter domain) and αEstS9Δ (a single-domain esterase) were constructed. However, only one of recombinant K. phaffii strains, namely Komagataella phaffii X-33/pPICZαestS9Δ,...
-
Wavelet filtering of signals without using model functions
PublicationThe effective wavelet filtering of real signals is impossible without determining their shape. The shape of a real signal is related to its wavelet spectrum. For shape analysis, a continuous color wavelet spectrogram of signal level is often used. The disadvantage of continuous wavelet spectrogram is the complexity of analyzing a blurry color image. A real signal with additive noise strongly distorts the spectrogram based on continuous...
-
The radiated immunity test of an astable multivibrator for various supply voltages
Open Research DataThe dataset presents a result of measurements that are a part of electromagnetic field immunity tests. The radiated, radio frequency, immunity tests were carried out for a typical astable electronic multivibrator supplied from a power supply with an output voltage of 6V and 7.5 V. Tests of immunity of electronic systems to radiated radio frequency (RF)...
-
FDTD Simulations on Disjoint Domains with the Use of Discrete Green's Function Diakoptics
PublicationA discrete Green's function (DGF) approach to couple disjoint domains in the finite-difference time-domain (FDTD) grid is developed. In this method, total-field/scattered-field (TFSF) FDTD domains are associated with simulated objects whereas the interaction between them is modeled with the use of the DGF propagator. Hence, source and scatterer are simulated in separate domains and updating of vacuum cells, being of little interest,...
-
Stress Detection of Children With ASD Using Physiological Signals
PublicationThis paper proposes a physiological signal-based stress detection approach for children with autism spectrum disorder (ASD) to be used in social and assistive robot inter- vention. Electrodermal activity (EDA) and blood volume pulse (BVP) signals are collected with an E4 smart wristband from children with ASD in different countries. The peak count and signal amplitude features are derived from EDA signal and used in order to detect...
-
Noise effect on parameters of quiet sonar with code modulation
PublicationEarlier publications of the paper authors have shown that the use of code keying mixed with the CW FM sound signal allows the significant reduction in the distance measurement error, compared to classic silent CW FM sonar. In addition to the code modulation parameters, the magnitude of this error is influenced by the received input acoustic noise. The article shows the dependence of the input signal-to-noise ratio and the sound...
-
Functional fluorine-doped tin oxide coating for opto-electrochemical label-free biosensors
PublicationSensors operating in multiple domains, such as optical and electrochemical, offer properties making biosensing more effective than those working in a single domain. To combine such domains in one sensing device, materials offering a certain set of properties are required. Fluorine-doped tin oxide (FTO) thin film is discussed in this work as functional optically for guiding lossy modes and simultaneously electrochemically, i.e....
-
Optimal configuration of an electrode array for measuring ventricles' contraction
PublicationAn influence of an electrode-array configuration on an impedance signal composition for a fixed spatial distribution of its sources is examined in the paper. The Finite Element Method and Geselowitz relationship were used for examining three different electrode-arrays. A sensitivity approach was used to evaluate each configuration assuming that localization of the signal source is known. A conductivity change, thus the source of...
-
Wear in siding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specim. sets #20-#21, #22-#23, #24-#25, #26-#27, #28-#29,#30 - #31. Run time: 4-8h.
Open Research DataWear in sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer.Running time: 4-8h.Specimen sets:Specim. sets (# [upper, rotating] - #[lower, non-rotating]):#20-#21, #22-#23, #24-#25, #26-#27,...
-
Specimen running-in. Prep. to sliding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specimen set #24 - #25.
Open Research DataSpecimen running-in procedure. Preparation to sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer. Specimen set #24 (upper, rotating), #25 (lower, non-rotating)CZ_PRZYS.MAT - accelerometerMOM_TAR.MAT...
-
Specimen running-in. Prep. to sliding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specimen set #28 - #29.
Open Research DataSpecimen running-in procedure. Preparation to sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer. Specimen set #28 (upper, rotating), #29 (lower, non-rotating)CZ_PRZYS.MAT - accelerometerMOM_TAR.MAT...
-
Wear in siding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specim. sets #20-#21, #22-#23, #24-#25, #26-#27, #28-#29,#30 - #31. Run time: 0-4h.
Open Research DataWear in sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer.Running time: 0 - 4h.Specimen sets:Specim. sets (# [upper, rotating] - #[lower, non-rotating]):#20-#21, #22-#23, #24-#25, #26-#27,...
-
Specimen running-in. Prep. to sliding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specimen set #30 - #31.
Open Research DataSpecimen running-in procedure. Preparation to sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer. Specimen set #30 (upper, rotating), #31 (lower, non-rotating)CZ_PRZYS.MAT - accelerometerMOM_TAR.MAT...
-
Specimen running-in. Prep. to sliding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specimen set #20 - #21.
Open Research DataSpecimen running-in procedure. Preparation to sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer. Specimen set #20 (upper, rotating), #21 (lower, non-rotating)CZ_PRZYS.MAT - accelerometerMOM_TAR.MAT...
-
Specimen running-in. Prep. to sliding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specimen set #22 - #23.
Open Research DataSpecimen running-in procedure. Preparation to sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer. Specimen set #22 (upper, rotating), #23 (lower, non-rotating)CZ_PRZYS.MAT - accelerometerMOM_TAR.MAT...
-
Specimen running-in. Prep. to sliding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specimen set #28 - #29.
Open Research DataSpecimen running-in procedure. Preparation to sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer. Specimen set #28 (upper, rotating), #29 (lower, non-rotating)CZ_PRZYS.MAT - accelerometerMOM_TAR.MAT...
-
Specimen running-in. Prep. to sliding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specimen set #26 - #27.
Open Research DataSpecimen running-in procedure. Preparation to sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer. Specimen set #26 (upper, rotating), #27 (lower, non-rotating)CZ_PRZYS.MAT - accelerometerMOM_TAR.MAT...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Man 29 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Man 29 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows in the air - Woman 27 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Woman 27 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Woman 28 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Second Man 29 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Second Man 29 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 28 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows in the air - Man 29 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Man 29 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...