Filters
total: 2410
-
Catalog
- Publications 1746 available results
- Journals 90 available results
- Conferences 1 available results
- Publishing Houses 1 available results
- People 230 available results
- Projects 4 available results
- Laboratories 1 available results
- Research Equipment 1 available results
- e-Learning Courses 43 available results
- Events 5 available results
- Open Research Data 288 available results
displaying 1000 best results Help
Search results for: electrical%20conductivity
-
University Politehnica of Bucharest Scientific Bulletin Series C-Electrical Engineering and Computer Science
Journals -
Electrochemical properties of porous Sr0.86Ti0.65Fe0.35O3 oxygen electrodes in solid oxide cells: Impedance study of symmetrical electrodes
PublicationThis work evaluates porous Sr0.86Ti0.65Fe0.35O3 (STF35) as a possible oxygen electrode material for Solid Oxide Cells. The powder synthesis was performed by solid state method. Characterization included DC electrical conductivity study of sintered bulk samples and impedance spectroscopy study of symmetrical electrodes deposited on gadolinium doped ceria substrates. Measurements were carried out in atmospheres with different pO2...
-
Dianli Zidonghua Shebei / Electric Power Automation Equipment
Journals -
Dianli Xitong Zidonghua/Automation of Electric Power Systems
Journals -
Dianji yu Kongzhi Xuebao/Electric Machines and Control
Journals -
Corrosion Study of Ceria Protective Layer Deposited by Spray Pyrolysis on Steel Interconnects
PublicationSingle fuel cells and electrolysis cells are assembled into stacks using interconnects in order to increase power and gas production capacity. The most common choice for the interconnect material is stainless steel. It has good electrical and mechanical properties and is also cost effective. One of the problems when using steel is the formation of a thermally grown oxide scale during use which has a lower electrical conductivity...
-
Experimental data of galvanic electric cells measurements
Open Research DataInternal temperature of an electric cell can be measured and monitored using microsphere-based fiber-optic sensors with thin ALD ZnO coating. Their compact size will allow to integrate them easily and effectively within the electric cells. Utilization of presented sensors allows to detect, in real time, damages to the structure of the sensor head that...
-
Assessment of under power ed propulsion machinery in electrically driven small inland waterway passenger ships from classification society point of view
PublicationPaper presents short operat ional a nd engineering analysis of underpowered propulsion in small electrically propelled small inland passenger ships. There is evidence that in certain weather conditions the phenomena of added aerodynamic resistance of small water crafts may have seriou s influence on their speed and manoeuvrability. Existing regulations like class societies rules for ship classification and construction or EU Directive 2006/87/EC do...
-
ECG measurement in the bathtub - getting into the bathtub- men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
Destructiveness of Profits and Outlays Associated with Operation of Offshore Wind Electric Power Plant. Part 1: Identification of a Model and its Components
Publication -
The issue of uncertainty of visual measurement techniques for long distance measurements based on the example of applying electric traction elements in diagnostics and monitoring
PublicationRail transport is the most economical and energy-effective in the field of land transport, in particular electrified. In order to ensure efficient and reliable operation of electrified rail transport, the issues of monitoring and diagnostics of the traction infrastructure and vehicles are extremely important. The most critical point in the transmission of electric energy to the vehicle is the sliding contact of the current collector...
-
Energy Management for PV Powered Hybrid Storage System in Electric Vehicles Using Artificial Neural Network and Aquila Optimizer Algorithm
PublicationIn an electric vehicle (EV), using more than one energy source often provides a safe ride without concerns about range. EVs are powered by photovoltaic (PV), battery, and ultracapacitor (UC) systems. The overall results of this arrangement are an increase in travel distance; a reduction in battery size; improved reaction, especially under overload; and an extension of battery life. Improved results allow the energy to be used efficiently,...
-
Electric transport in organic system with planar DBP/F16ZnPc junction on the basis of direct current and small signal admittance spectra analysis
PublicationThe objective of this work was to determine electric transport in the organic device based on a planar junction of electron donor and electron acceptor materials, namely ITO/MoO3/DBP/F16ZnPc/BCP/Ag. The analysis reported herein was based on direct current-voltage measurements and small-signal admittance spectra in the dark and under illumination. Such analysis may provide information on potential barriers, parasitic resistances...
-
Application of Generalized Regression Neural Network and Gaussian Process Regression for Modelling Hybrid Micro-Electric Discharge Machining: A Comparative Study
Publication -
Nonlinear impedance of 40Bi2VO5.5-60SrB4O7 annealed glass at 473 K for 3 h measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrical properties of 40Bi2VO5.5-60SrB4O7 glass annealed at 473 K for 3h was measured by impedance spectroscopy method.
-
Nonlinear impedance of Bi2VO5.5 ceramic prepared by traditional melt quenching technique was measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrical properties of Bi2VO5.5 ceramic prepared by traditional melt quenching technique was measured by impedance spectroscopy method.
-
Nonlinear impedance of 40Bi2VO5.5-60SrB4O7 annealed glass at 593 K measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrical properties of 40Bi2VO5.5-60SrB4O7 glass annealed at 593 K was measured by impedance spectroscopy method.
-
Properties of Barium Cerate-Zirconate Thin Films
PublicationIn this work, we review several experimental results showing the electrical properties of barium cerate-zirconate thin films and discuss them in view of the possible influence of various factors on their properties. Most of the presented Ba(Ce, Zr, Y)O3 thin films were formed by the pulsed laser deposition (PLD) technique, however thin films prepared using other methods, like RF magnetron sputtering, electron-beam deposition, powder...
-
Synthesis and properties of porous Sr 0.96 Y 0.04 Ti 1−x Nb x O 3
PublicationA series of porous, single phase Sr0.96Y0.04Ti1-xNbxO3 samples was obtained using a wet synthesis method (modified citrate sol-gel) method. Temperature-programmed reduction (TPR) and temperature-programmed oxidation (TPO) measurements have shown high stability of the obtained material in variable (oxidizing/reducing) atmospheres. All samples exhibit high conductivity in hydrogen atmosphere with the highest value (around 1S/cm)...
-
Characteristics of La 0.8 Sr 0.2 Ga 0.8 Mg 0.2 O 3-δ -supported micro-tubular solid oxide fuel cells with LaCo 0.4 Ni 0.6-x Cu x O 3-δ cathodes
PublicationIn this study, micro-tubular solid oxide fuel cells (T-SOFCs) with extruded La0.8Sr0.2Ga0.8Mg0.2O3-δ (LSGM) electrolyte as the mechanical support and LaCo0.4Ni0.6O3-δ (LCNO) or LaCo0.4Ni0.4Cu0.2O3-δ (LCNCO) as cathodes were prepared and characterized. Partial substitution of Cu for the Ni-ion positions in the LCNO lattices was found to significantly enhance the densification and accelerate the grain growth. The porosity-corrected...
-
Mirosław Wołoszyn dr hab. inż.
PeopleMirosław Wołoszyn born in 1963 in Gdynia. He received the M.Sc. degree in 1987, the Ph.D. degree in 1997, and the D.Sc. (‘habilitation’) degree in 2013, all from the Gdańsk University of Technology. Since 1987 he has been with the above university, where he is currently Associate Professor of Electrical Engineering. His research interests include localization and identification of ferromagnetic objects by means of the magnetometric...
-
High temperature proton conduction in LaSbO4
PublicationLanthanum orthoantimonate was synthesized using a solid‐state synthesis method. To enhance the possible protonic conductivity, samples with the addition of 1 mol% Ca in La‐site, were also prepared. The structure was studied by the means of X‐ray diffraction, which showed that both specimens were single phase. The materials crystallized in the space group P2 1 /n. Dilatometry revealed that material expands non‐linearly with the...
-
Novel Class of Proton Conducting Materials—High Entropy Oxides
PublicationHere, for the first time, we present data on proton conductivity of high-entropy, single-phase perovskites. The BaZr0.2Sn0.2Ti0.2Hf0.2Ce0.2O3−δ, BaZr0.2Sn0.2Ti0.2Hf0.2Y0.2O3−δ, BaZr1/7Sn1/7Ti1/7Hf1/7Ce1/7Nb1/7Y1/7O3−δ, and BaZr0.15Sn0.15Ti0.15Hf0.15Ce0.15Nb0.15Y0.10O3−δ single-phase perovskites were synthesized. Before electrical measurements, materials were characterized using X-ray diffraction (XRD), scanning electron microscopy...
-
Structure and thermoelectric properties of nickel-doped copper selenide synthesised in a hydrogen atmosphere
PublicationNickel-doped copper selenide—Cu2-xNixSe (x = 0; 0.01; 0.02; 0.03)—materials with high thermoelectric properties were synthesised through reduction of reagents in hydrogen. The impact of the nickel content on both the microstructure and thermoelectric properties was examined. The nickel-doped samples’ microstructure differed significantly from pristine copper selenide. Besides Cu2Se, copper precipitations were present in the materials....
-
Thermoelectric properties of bismuth-antimony-telluride alloys obtained by reduction of oxide reagents
PublicationThe BieSbeTe alloys with different Bi/Sb/Te ratio were fabricated by an innovative method. For that purpose the oxide reagents were melted at high temperature, then quenched to form pellets, milled to a powder and finally reduced in hydrogen at various temperatures. Complex structures consisting of connected thin layers forming a continuous path between nano- and micrometer size grains have been obtained. The electrical conductivity,...
-
Nonlinear and linear impedance of bismuth vanadate ceramics and its relation to structural properties
PublicationThe nonlinear and linear electrical properties, topography, and microstructure of bismuth-vanadate ceramics, were studied. The structurewas observed with the use of X-ray diffraction (XRD), scanning electronmicroscopy (SEM), atomic force microscopy (AFM) and confocal microscopy methods. The obtained results showed that ceramic is porous. Two phase transitionswere determinedwith the use of DSC measurements. The linear and nonlinear ac...
-
Michał Tomasz Kucewicz dr
PeopleMichal Kucewicz was born in 1986 in Gdansk. In 2005 he completed International Baccalaureate programme in Topolowka (III High School in Gdańsk). Thanks to the G. D. Fahrenheit scholarship, he moved to the United Kingdom to study neuroscience. He received his Bachelor’s and Master’s degree from the Cambridge University, and his doctoral degree from the University of Bristol specializing in electrophysiology of memory and cognitive...
-
The voltage on bus bars of the main switchboard of the car carrier electrical power system during sea trials
Open Research DataThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results conducted onboard the car carrier during sea trials.
-
The voltage on bus bars of the main switchboard of the ro-ro ship electrical power system during maneuvering
Open Research DataThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results carried out onboard a ro-ro ship during maneuvering.
-
Steady-State Vibration Level Measurement of the Five-Phase Induction Machine during Third Harmonic Injection or Open-Phase Faults
PublicationMultiphase electric machines are increasingly used in various industries and for electromobility. Complex systems have been developed for the control and powering of multiphase machines, which require verification. The quality of control and the power supply of electric machines is usually evaluated by analyzing various electrical parameters. On the other hand, taking into account the fact that a motor is an electrical-mechanical...
-
Fractional Order Circuit Elements Derived from Electromagnetism
PublicationIn this paper, derivations of fractional-order (FO) circuit-element equations from electromagnetism are presented. Whilst many papers are devoted to FO modelling of electrical circuits, there are no strong foundations for such an approach. Therefore, we investigate relations between the FO electromagnetism and the FO circuit theory. Our derivations start from quasi-static (QS) approximations of Maxwell's equations in media with...
-
ECG measurement in the bathtub - drl on the outside of the bathtub on one side- men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, drl behind the back - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at buttocks, strengthening 2x smaller, drl at buttocks - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the buttocks, drl at the feet - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - one side of the bathtub is grounded, drl outside the bathtub - men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the knees - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, sitting motionless - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the knees, signal amplification x2 - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the buttocks, drills at the feet, grounding the bathtub - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, placed on the back - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - sitting on the measuring electrodes, drl outside the bathtub - men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl on the outside of the bathtub on both sides, measuring electrodes on the front and back of the bathtub- men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl in the water, measuring electrodes on the sides of the bathtub - men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl on one side of the bath mass on the other - the person is moving- men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl outside the bathtub on both sides- men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl in water, front and back measuring electrodes - men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, bath simulation - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - sitting on measuring electrodes, drl in water - men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, drl at the buttocks - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...