Search results for: TOMOGRAPHY
-
Integration and verification of meteorological observations and NWP model data for the local GNSS tomography
PublicationGNSS meteorology applies the Global Navigation Satellite Systems (GNSS) to derive information about the state of the atmosphere (particularly troposphere). The tomography is one of the methods used in GNSS meteorology. The input data of GNSS tomography are the signal troposphere delays, results of GNSS data processing and additionally meteorological observations and Numerical Weather Prediction (NWP) models data. Different types...
-
Assessment of Wooden Beams from Historical Buildings Using Ultrasonic Transmission Tomography
PublicationThe main goal of this study was non-destructive evaluation of wooden elements using ultrasonic waves. The inspection was carried out on wooden beams from a historical object. Elastic wave signals were processed by ultrasonic transmission tomography to obtain imaging of the internal structure of tested elements without disturbing their state and integrity. The focus was on the influence of wood anisotropy on the propagation of ultrasonic...
-
Advanced Monte Carlo simulator of the polarization-sensitive optical coherence tomography systems
PublicationSimulations of the optical coherence tomography (OCT) systems using the Monte Carlo method is a widely explored research area. However, there are several difficulties that need to be overcome in order to properly model the OCT imaging with the Monte Carlo algorithm. First of all, the temporal and the spatial coherence of the scattered light need to be considered, since OCT is based on the interference phenomenon. For the same reason,...
-
Role of quantitative chest perfusion computed tomography in detecting diabetic pulmonary microangiopathy
PublicationAims: Aimof the study was to determine the role of perfusion chest computed tomography(pCT) in evaluation of pulmonary diabetic angiopathy.Methods: 18 never-smoking patients (10 diabetic patients and 8 healthy controls) underwentchest high resolution CT (HRCT) and then pCT scanning. In both groups, blood tests,biochemical analysis, fibrinogen, HbA1c, spirometry, diffusion capacity for carbonmonoxide(DLCO) and body pletysmography...
-
Quantitative active dynamic thermal ir-imaging and thermal tomography in medical diagnostics
PublicationPraca dotyczy nowych technik obrazowania w diagnostyce medycznej, wykorzystując przetwarzanie obrazów termicznych rejestrowanych w podczerwieni. Opisano właściwości termiczne tkanek biologicznych, omówiono medele termiczne i zdefiniowano zastępcze parametry syntetyczne, metody pomiarów i stosowane urządzenia. Omówiono procedury akwizycji danych i ich przetwarzania. Wprowadzono pojęcie tomografii termicznej. Opisano przeprowadzone...
-
Quantitative active dynamic thermal Ir-Imaging and thermal tomography in medical diagnostics
Publication -
Use of X-Ray Computed Tomography for Ice Detection Applied to Organ Cryopreservation
Publication -
Ovarian tissue cryopreservation by stepped vitrification and monitored by X-ray computed tomography
Publication -
A New Classification of the Morphology of Complete Ponticulus Posticus on Cone Beam Computed Tomography
Publication -
Quantitative Active Dynamic Thermal IR-Imaging and Thermal Tomography in Medical Diagnostics
Publication.
-
Enhancing Renal Tumor Detection: Leveraging Artificial Neural Networks in Computed Tomography Analysis
PublicationRenal cell carcinoma is one of the most common cancers in Europe, with a total incidence rate of 18.4 cases per 100 000 population. There is currently significant overdiagnosis (11% to 30.9%) at times of planned surgery based on radiological studies. The purpose of this study was to create an artificial neural network (ANN) solution based on computed tomography (CT) images as an additional tool to improve the differentiation of...
-
Anisotropy and compaction gradient assessment on rammed earth specimens through sonic tomography approach
PublicationRammed earth is a traditional construction technique that has recently gained attention because of its benefits from an ecological perspective. The conservation of the existing valuable cultural heritage sites and the quality control of new constructions built with this material require the development and application of practical inspection techniques. This paper explores the application of sonic tests and sonic tomography as...
-
Imaging of Increasing Damage in Steel Plates Using Lamb Waves and Ultrasound Computed Tomography
PublicationThis paper concerns inspection of steel plates, with particular emphasis on the assessment of in-creasing damage. Non-destructive tests were performed on four plates, one of which was un-damaged, while the remaining three had a defects in the form of circular holes with a diameter of 2, 5, and 10 cm. Guided Lamb waves were used in the research, and the image reconstruction was performed using ultrasound computed tomography. The...
-
Using the ultrasonic tomography method to study the condition of wooden beams from historical buildngs
PublicationThe need to evaluate the integrity of wooden structural elements is constantly increasing. Non-destructive methods are becoming more popular in this field of research. One type of non-destructive testing is the ultrasonic imaging method, which allows the analysis of internal wood structures without disturbing their state and integrity. In this study, we are interested in assessing the effect of wood condition on the ultrasound...
-
Tome-lapse X-ray tomography imaging of flow patterns in versatile silo model
PublicationThe paper introduces a new versatile silo model that was especially designed for in situ X-ray tomography studies of silo discharge for various flow conditions, namely concentric and eccentric. The presented work focuses on organic granular materials where low fraction of short-grain white rice is mixed with spheroidal sorghum particles. The high-quality tomography images combined with adequate image processing strategy allows...
-
Novel approach to modeling spectral-domain optical coherence tomography with Monte Carlo method
PublicationNumerical modeling Optical Coherence Tomography (OCT) systems is needed for optical setup optimization, development of new signal processing methods and assessment of impact of different physical phenomena inside the sample on OCT signal. The Monte Carlo method has been often used for modeling Optical Coherence Tomography, as it is a well established tool for simulating light propagation in scattering media. However, in this method...
-
Optical coherence tomography and magnetic resonance imaging visual pathway evaluation in Wolfram syndrome
Publication -
Fiber - optic low-coherence tomography system for visualization of internal structure of ceramic materials
PublicationW artykule przedstawiono światłowodowy system dwuwymiarowej wizualizacji niejednorodnych struktur warstw ceramicznych. Omówiono projekt i fizyczną realizację układu wykorzystującego optyczną, niskokoherentną reflektometrię optyczną, która umożliwia niedestrukcyjne obrazowanie wewnętrznych struktur różnych materiałów. W pracy przedstawiono przykładowe wyniki pomiarów wewnętrznych warstw LSFO.
-
<title>Ultrahigh-resolution detection techniques for biomedical applications of optical coherent tomography</title>
Publication -
Measurement of selected characteristics of low-coherence optical signal sources for optical coherence tomography
Publication -
<title>Modeling of broadband light source to use with optical coherent tomography system</title>
Publication -
Measurement of selected characteristics of low-coherence optical signal sources for optical coherence tomography
PublicationOCT to nowa metoda badania wewnętrznych struktur materiałów. Wśród wielu technik detekcji sygnału optycznego wykorzystywanych w OCT najpopularniejszą i najbardziej obiecującą jest OLCR (Opticla-Low Coherence Reflectomerty - reflektometria niskokoherentna). OLCR wykorzystuje szerokopasmowe źródła, których parametry, jak np.: charakterystyka widmowa, charakterystyka szumowa, determinują właściwości metrologiczne systemu OCT. W artykule...
-
Non-destructive inspection of anti-corrosion protective coatings using optical coherent tomography
PublicationW artykule przedstawiono zastosowanie optycznej tomografii koherentnej (OCT) do badania antykorozyjnych powłok ochronnych. Omówiono właściwości optycznej interferometrii niskokoherentnej jako zastosowanej metody pomiarowej, opisano budowę pomiarowego systemu OCT, zbudowanego w Katedrze Metrologii i Optoelektroniki WETI PG. Przy pomocy zrealizowanego systemu przebadano grupę powierzchni metalicznych pokrytych różnymi powłokami antykorozyjnymi....
-
Experimental investigations of fracture process in concrete by means of x-ray micro-computed tomography
PublicationW artykule pokazano doświadczalne wyniki badań procesu pękania w betonie stosując mikro-tomografię. Doświadczenia wykonano dla zginanych belek betonowych. Wyniki doświadczalne modelowano stosując MES na bazie modelu z degradacją sztywności sprężystej z nielokalnym osłabieniem. Beton symulowano jako materiał 4-fazowy. Uzyskano dobra zgodność wyników MES z doświadczeniami.
-
Silica In Silico: A Molecular Dynamics Characterization of the Early Stages of Protein Embedding for Atom Probe Tomography
PublicationA novel procedure for the application of atom probe tomography (APT) to the structural analysis of biological systems, has been recently proposed, whereby the specimen is embedded by a silica matrix and ablated by a pulsed laser source. Such a technique, requires that the silica primer be properly inert and bio-compatible, keeping the native structural features of the system at hand, while condensing into an amorphous, glass-like...
-
Assessment of particular abdominal aorta section extraction from contrast-enhanced computed tomography angiography
PublicationThe aim of this work is to improve the accuracy of extraction of a particular abdominal aorta section and to reduce the distortion in three-dimensional Computed Tomography Angiography (CTA) images. Imaging modality and quality plays crucial role in the medical diagnostic process, thus ensuring high quality of images is essential at every stage of acquisition and processing.Noise is defined as a disturbance of the image quality...
-
X-Ray Computer Tomography Study of Degradation of the Zircaloy-2 Tubes Oxidized at High Temperatures
PublicationThe investigations of high-temperature oxidation of zirconium alloys, applied for fuel pellets in nuclear power plants, are usually limited to oxidation kinetics, phase transformations and microstructural characterization. The purpose of this research was to characterize the degradation phenomena occurring within oxide layer and at the interface oxide/metal, on internal and external Zircaloy-2 tube...
-
Wave propagation signals for ultrasonic tomography of concrete during splitting
Open Research DataThe DataSet contains the results of the mechanical behaviour of a concrete cube with dimensions 70 x 70 x 70 cm3under the splitting test. Three cubes were tested: cube 1 (concrete with polymer fibres), cube 2 (concrete with steel fibres) and cube 3 (plain concrete).
-
Assessment of the cryoprotectant concentration inside a bulky organ for cryopreservation using X-ray computed tomography
Publication -
Endodontic Treatment Outcomes in Cone Beam Computed Tomography Images—Assessment of the Diagnostic Accuracy of AI
Publication -
Solitary median maxillary central incisor syndrome: cone beam computed tomography illustrated review
Publication -
Visualizing the macroscale spatial distributions of biofilms in complex flow channels using industrial computed tomography
Publication -
Application of electrical capacitance tomography (ECT) to measurement of sand concentration changes during silo flow
PublicationW artykule przedstawiono wyniki doświadczeń pomiaru zmian koncentracji materiału granulowanego podczas przepływu silosowego. Zmiany zostały pomierzone przy pomocy tomografu. Doświadczenia wykonano w silosie cylindrycznym dla 2 różnych szorstkości ścian.
-
Detection of debonding in reinforced concrete beams using ultrasonic transmission tomography and hybrid ray tracing technique
PublicationThis paper concerns inspection of reinforced concrete elements, with particular emphasis on assessing the quality of the adhesive connection between steel and concrete. A novel theoretical model was developed to determine the paths of transmitted, refracted and reflected elastic waves as well as a creeping wave propagated along the inclusion surface. Imaging the internal structure of tested beams was based on wave propagation measurements...
-
Nano-particle doped hydroxyapatite material evaluation using Spectroscopic Polarization Sensitive Optical Coherence Tomography
PublicationBio-ceramics such as hydroxyapatite (HAp) are widely used materials in medical applications, especially as an interface between implants and living tissues. There are many ways of creating structures from HAp like electrochemical assisted deposition, biomimetic, electrophoresis, pulsed laser deposition or sol-gel processing. Our research is based on analyzing the parameters of the sol-gel method for creating thin layers of HAp....
-
Computed tomography indicators of cerebral microperfusion improve long term after carotid stenting in symptomatic patients
PublicationOBJECTIVES: We tested the hypothesis that computed tomography (CT) perfusion markers of cerebral microcirculation would improve 36 months after internal carotid artery stenting for symptomatic carotid stenosis while results obtained 6-8 weeks after the stenting procedure would yield a predictive value. METHODS: We recruited consecutive eligible patients with >70% symptomatic carotid stenosis with a complete circle of Willis and...
-
<title>Fiber-optic low-coherence tomography system for visualization of internal structure of ceramic materials</title>
Publication -
The diagnostic accuracy of cone beam computed tomography in detecting temporomandibular joint bony disorders: a systematic review
Publication -
Analysis of the bulk solid flow during gravitational silo emptying using X-ray and ECT tomography
PublicationW pracy przedstawiono wyniki pomiarów zmian koncentracji piasku bezkohezyjnego zachodzących w prostokątnym modelu silosu opróżnianym grawitacyjnie. Pomiary wykonano z zastosowaniem kontynualnego promieniowania rentgenowskiego oraz z użyciem tomografii pojemnościowej. Badania wykonano dla zróżnicowanego zagęszczenia początkowego piasku oraz różnego stopnia szorstkości ścian. Szczególny nacisk położono na zachowanie sie materiału...
-
Perfusion computed tomography: 4 cmversus8 cm coverage size in subjects with chronic carotid artery stenosis
PublicationOBJECTIVE: The impact of coverage size on global cerebral blood flow (CBF), cerebral blood volume (CBV), mean transit time (MTT) and time to peak (TTP) parameters has not been investigated in patients with chronic carotid artery stenosis. METHODS: 63 patients with stenosis of >70% within a single internal carotid artery and neurological symptoms were randomly assigned to two well-matched groups. Differences in CT perfusion scan...
-
Quantitative estimation of volume changes of granular materials during silo flow using X-ray tomography.
PublicationW artykule przedstawiono wyniki badań doświadczalnych nad zmianami objętościowymi materiału granulowanego podczas przepływu silosowego. Badania wykonano przy zastosowaniu tomografii rentgenowskiej. Wyniki porównano z wynikami doświadczalnymi przy zastosowaniu cyfrowej obróbki zdjęć płynącego materiału.
-
Abdominal Aortic Aneurysm segmentation from contrast-enhanced computed tomography angiography using deep convolutional networks
PublicationOne of the most common imaging methods for diagnosing an abdominal aortic aneurysm, and an endoleak detection is computed tomography angiography. In this paper, we address the problem of aorta and thrombus semantic segmentation, what is a mandatory step to estimate aortic aneurysm diameter. Three end-to-end convolutional neural networks were trained and evaluated. Finally, we proposed an ensemble of deep neural networks with underlying...
-
Soft Tissue Retraction Maneuver in Cone Beam Computed Tomography Prior to Crown-Lengthening Procedure—A Technical Note
PublicationBackground: An accurate determination of the biological width and the relationship of the cemento-enamel junction with the border of the alveolar bone is crucial during a clinical crown-lengthening (CCL) procedure. The aim of this study was to present a technical note about the retraction techniques in cone beam computed tomography (CBCT) prior to CCL, highlighting the significant enhancement in procedural accuracy and predictability...
-
Analysis of the relationship between cutting forces and local structural properties of Scots pine wood aided by computed tomography
PublicationX-ray computed tomography (CT) is utilised in some sawmills today, primarily for enhancing value yield and for process automation, which includes log sorting and sawing optimisation. Nevertheless, there is a scarcity of recent research utilising CT to assess the local cutting process. As a preliminary study, this paper addresses this gap by using CT to investigate the connections between local cutting force and local wood properties...
-
Thermal Tomography in Medicine. 9th European Congress of Thermology, Kraków, 29.05-01.06.2003. Tomografia termiczna w medycynie.
PublicationArtykuł prezentuje możliwości zastosowań techniki tomografii termicznej w aplikacjach medycznych. Dyskutowane są możliwości i ograniczenia prezentowanej metody w odniesieniu do organizmów żywych.
-
Microstructure–Property Relationship of Polyurethane Foams Modified with Baltic Sea Biomass: Microcomputed Tomography vs. Scanning Electron Microscopy
PublicationIn this paper, novel rigid polyurethane foams modified with Baltic Sea biomass were compared with traditional petro-based polyurethane foam as reference sample. A special attention was focused on complex studies of microstructure, which was visualized and measured in 3D with high-resolution microcomputed tomography (microCT) and, as commonly applied for this purpose, scanning electron microscopy (SEM). The impact of pore volume,...
-
Microstructure–Property Relationship of Polyurethane Foams Modified with Baltic Sea Biomass: Microcomputed Tomography vs. Scanning Electron Microscopy
Publication -
An optimized controlled rate slow cooling protocol for bovine ovarian tissue cryopreservation by means of X-ray computed tomography
Publication -
Bimodal Nd-Doped LuVO4 Nanoprobes Functionalized with Polyacrilic Acid for X-Ray Computed Tomography and NIR Luminescent Imaging
Publication -
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY
Journals