displaying 1000 best results Help
Search results for: UNDERGROUND HEAT EXCHANGER
-
Channel Blockage and Flow Maldistribution during Unsteady Flow in a Model Microchannel Plate heat Exchanger
PublicationThis paper describes the problem of channel blockage as a result of flow maldistribution between the channels of a model mini channel plate heat exchanger consisting of one pass on each leg. Each leg of the heat exchanger contains 51 parallel and rectangular minichannels of four hydraulic diameters namely 461 μm, 571 μm, 750 μm and 823 μm. In addition, a more complex geometry has been investigated where for the sake of breaking...
-
Monitoring Regenerative Heat Exchanger in Steam Power Plant by Making Use of the Recurrent Neural Network
PublicationArtificial Intelligence algorithms are being increasingly used in industrial applications. Their important function is to support operation of diagnostic systems. This paper pesents a new approach to the monitoring of a regenerative heat exchanger in a steam power plant, which is based on a specific use of the Recurrent Neural Network (RNN). The proposed approach was tested using real data. This approach can be easily adapted to...
-
Corrosion-erosion damage of heat exchanger tubes by desalted crude oil flowing at shell side
Publication -
Corrosion-erosion damage of heat exchanger tubes by desalted crude oil flowing at shell side.
PublicationRurki wymiennika zostały uszkodzone lokalnie przez odsoloną ropę naftową przepływającą pod ciśnieniem 2,6 MPa i w temperaturze 385-395K. Większość powierzchni rurek nie była uszkodzona i była pokryta osadem związków organicznych i nieorganicznych, zabezpieczającym przed uszkodzeniami. Badania wykluczyły możliwość występowania intensywnej korozji elektrochemicznej na powierzchniach rurek pozbawionych osadu. Przyczyną perforacji...
-
Thermal and economic investigation of straight and U-bend double tube heat exchanger with coiled wire turbulator
PublicationExperimental research has been carried out for four individual heat exchanger constructions, i.e., plain double tube, turbulized double tube, plain U-bend and U-bend with turbulator. Tests were made for the water-water system. The study covered a wide measuring range, i.e., Re = 800–9000 – on the shell side, for a constant cold water temperature of 9 ◦C and hot water of 50 ◦C. The heat exchangers were made from copper tubes with...
-
Experimental investigation on straight and u-bend double tube heat exchanger with active and passive enhancement methods
PublicationAuthors in this work want to demonstrate the possibility to increase the heat transfer efficiency by using simple wire coil inserts to create turbulent flow in the boundary layer as well as air blowing into the annulus of the pipe. In the study, Wilson plot approach was applied in order to estimate heat transfer coefficients for all heat exchanger (HX) configurations. The study focuses on experimental values of heat transfer coefficient...
-
Thermal Design of Double Pipe Heat Exchanger Used as an Oil Cooler in Ships: A Comparative Case Study
Publication -
Synergistic effects of a swirl generator and MXene/ water nanofluids used in a heat exchanger pipe of a negative CO2 emission gas power plant
Publicationfocus on optimizing heat exchangers contributes to improved temperature control mechanisms, ensuring the sustainable operation of innovative power plants working towards negative CO2 emissions. In the realm of oxy-combustion within Negative CO2 Emission Power Plants (nCO2PP), the temperature of combustion products surpasses 3000 (K). Addressing this challenge, the imperative arises to reduce these elevated temperatures to a manageable...
-
Comprehensive thermodynamic analysis of the CAES system coupled with the underground thermal energy storage taking into account global, central and local level of energy conversion
PublicationA key aspect of CAES is the optimal configuration of the thermodynamic cycle. In this paper, the situation of cooperation between the current conventional power plants and wind farms is analyzed, and then, based on thermodynamic models, the process of storing thermal and electrical energy in the CAES system coupled with a heat storage and recovery is developed. Therefore, three levels can be distinguished, namely: the global level...
-
Thermodynamic analysis of the Compressed Air Energy Storage system coupled with the Underground Thermal Energy Storage
PublicationImprovement of flexibility is one of the key challenges for the transformation of the Polish Power System aiming at a high share of renewable energy in electricity generation. Flexible and dispatchable power plants will contribute to this ongoing transformation process as they compensate for fluctuations in electricity generation from renewable energy sources such as wind and photovoltaics. In this context, CAES storage tanks are...
-
CHARAKTERYSTYKA WYMIANY CIEPŁA I OPORÓW PRZEPŁYWU OMYWANIA MIKROSTRUGAMI ROZWINIĘTEJ POWIERZCHNI
PublicationW artykule przedstawiono eksperymentalne badania kompaktowego wymiennika ciepła z intensyfikacją przejmowania ciepła przy użyciu mikrostrug. Niniejszy artykuł przedstawia projekt i testy prototypu, wymiennika ciepła typu mikrostrugowego. Modułowa konstrukcja wymiennika umożliwia zmianę wymiarów geometrycznych, a także zmianę materiału przegrody wymiennika ciepła. Metoda graficzna Wilsona została z zastosowana w celu określenia...
-
Analytical and reliability data from the real-time simulator biogas plant
Open Research DataThe dataset represents the results of biogas plant simulation. The described plant is an agricultural biogas system, which can produce electrical energy with power estimated up to 1070 kW and heat energy that can reach 1200 kW simultaneously.
-
Testing an evaporator operation with a concave manifold, condenser temperature 30, evaporator temperature 70 and preheater temperature 60
Open Research DataThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a bifurcation manifold, condenser temperature 20 and evaporator temperature 85
Open Research DataThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a concave manifold, condenser temperature 30, evaporator temperature 70 and preheater temperature 40
Open Research DataThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a trapezoidal manifold, condenser temperature 90 and evaporator temperature 90
Open Research DataThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a bifurcation manifold, condenser temperature 20 and evaporator temperature 70
Open Research DataThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a rectangular manifold, condenser temperature 30 and evaporator temperature 90
Open Research DataThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a trapezoidal manifold, condenser temperature 70 and evaporator temperature 60
Open Research DataThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a bifurcation manifold, condenser temperature 20 and evaporator temperature 95
Open Research DataThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a bifurcation manifold, condenser temperature 20 and evaporator temperature 90
Open Research DataThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
INTENSYFIKACJA WYMIANY CIEPŁA W WYMIENNIKU WĘŻOWNICOWYM Z WYKORZYSTANIEM PRZEGRÓD O RÓŻNEJ GEOMETRII
PublicationW pracy zaprezentowano możliwości wykorzystania pasywnej intensyfikacji wymiany ciepła w postaci przegród dla podniesienia efektywności energetycznej wymiennika wężownicowego. Badania zostały przeprowadzone z wykorzystaniem modułowego wymiennika z wężownicą w postaci grzałki elektrycznej. Medium odbierającym ciepło była woda o stałych parametrach cieplnoprzepływowych na wlocie do modułu. Pomiary przeprowadzono dla szerokiego zakresu...
-
Jan Wajs dr hab. inż.
People -
Charakterystyka eksploatacyjna pomp ciepła zainstalowanych w oczyszczalni ścieków
PublicationW artykule przedstawiono charakterystykę eksploatacyjną sprężarkowych pomp ciepła zainstalowanych w oczyszczalni komunalnej i wykorzystujących ścieki oczyszczone jako dolne źródło ciepła. Zastosowanie ścieków oczyszczonych jest uzasadnione ich dostępnością oraz stosunkowo wysoką temperaturą (10-25°C). Prawidłowa eksploatacja układu wymaga zastosowania pośredniego obiegu parowacza oraz regularnych zabiegów czyszczenia wymiennika...
-
Wykorzystanie ciepła niskotemperaturowego do procesu suszenia peletu ze słomy z wykorzystaniem mikrostrugowego wymiennika ciepła
PublicationW artykule przedstawiono wpływ temperatury medium suszącego na zmiany względnej oraz bezwzględnej zawartości wilgoci podczas suszenia peletu ze słomy. Proces suszenia przeprowadzono przy stałym ciśnieniu atmosferycznym i różnych wartościach temperatury powietrza, jako czynnika suszącego, wynoszących odpowiednio: 40℃, 60℃, 80℃, 100℃ oraz 120℃. Badania eksperymentalne wykonywano na innowacyjnym stanowisku wyposażonym w mikrostrugowy...
-
The significance of the underground experience: Selection of reference design cases from the underground public transport stations and interchanges of the European Union
PublicationAbstract Background Recent research into the way public transport users appreciate stations and interchanges has highlighted several key aspects. Importantly, the optimization of these facilities should not simply aim to resolve dissatisfiers, but should also focus on addressing satisfiers, through the incorporation of factors such as comfort and experience. ‘Soft requirements,’ which have emerged in architecture and urban design,...
-
Applicability of arrays of microjets heat transfer correlations to design compact heat exchangers
PublicationThe article presents experimental studies on a compact heat exchanger with heat transfer intensification by means of impinging microjets. The pursuit to provide high performance of heat exchangers is a response to the demand both in economics and in the universal tendency to miniaturization of industrial equipment. This paper presents the design and tests of a prototype, microjet heat exchanger. The modular design of the heat exchanger...
-
Thermal-FSI modeling of flow and heat transfer in a heat exchangerbased on minichanels
PublicationIn this paper selected numerical modelling problems for an advanced thermal-FSI ("Fluid Solid Interaction") mini-channel heat exchanger model are presented. Special attention is given to the heat transfer between the separated mediums for different mass flows. Similar modelling problems have also been discussed in the literature dedicated to numerical and theoretical modelling problems for typical heat exchangers [1, 2, 3]. Basic...
-
Overheating of underground power cable line due to its partial exposition to solar radiation
PublicationCurrent-carrying capacity of underground power cable lines depends, among others, on thermal resistivity of the soil and cables layout: trefoil formation, flat formation with or without spacing. If conditions for heat transfer in the ground are favorable, the current-carrying capacity is relatively high. Therefore, it generates risk of the power cables overheating, if part of the cable line is located vertically in the air, to...
-
Impact of an unsecured excavation on an underground pipeline
PublicationThe paper presents a numerical analysis of the impact of an unsecured excavation on an underground pipeline in selected soil conditions. The research was inspired by a real-life failure of a water pipeline which was caused by a nearby unsecured excavation (Sikora et al. 2015). The failure was triggered by displacement of soil mass in the vicinity of the pipeline. The study conducted in the framework of Finite Element...
-
Flow distribution and heat transfer in minigap and minichannel heat exchangers during flow boiling
PublicationThe topic of boiling heat transfer in miniscale geometries has focused the ever increasing interest of researchers in recent years. However, most of the works are related to mini- and microchannels and much less to minigaps. Meanwhile, minigaps allow for more comprehensive experimental studies, i.e. flow visualisations due to the flat, two-dimensional configuration of the flow. The results of the experimental investigations of...
-
SIMPLIFIED MODELING OF STRESS AND DEFLECTION LIMIT STATES OF UNDERGROUND TANKS
PublicationFuel tanks are designed with regard to standard actions and operating conditions. The work analyses the impact of corrosion and other means to variation of stresses and deformation of a horizontal underground tank shell. The computations are preliminary. Due to the long computational time of the entire tank the analysis is restricted to its part only. The full analysis is bound to assess structural reliability, further allowing...
-
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Journals -
HEAT TRANSFER ENGINEERING
Journals -
Reliability estimation of underground horizontal fuel tank limit states
PublicationFuel tanks are designed with regard to standard loads and operating conditions. The investigations of the paper show the impact of such factors as tank corrosion and other means on the variation of stress fields and deformation of the underground horizontal tank shell. The introduction of probabilistic methods allows for structural reliability assessment. While the computational time of the entire tank FEM model is high, the preliminary...
-
Underground Space
Journals -
Partition of friction heat between sliding semispaces due to adhesion-deformational heat generation
PublicationAnalytical expressions of heat-partition coefficient and contact temperatures for two sliding semispaces with account for adhesion-deformational heat generation and contact heat exchange have been obtained. The rate of deformational heat generation is assumed to decay exponentially with increase of distance from the interface. It has been shown that heat-generation configuration and the intensity of contact heat exchange have impact...
-
Recuperator with microjet technology as a proposal for heat recovery from low-temperature sources
PublicationA tendency to increase the importance of so called dispersed generation, based on the local energy sources and the working systems uti- lizing both the fossil fuels and the renewable energy resources is observed nowadays. Generation of electricity on industrial or domestic scale together with production of heat can be obtained for example through employment of the ORC systems. It is mentioned in the EU directive 2012/27/EU for...
-
Recuperator with microjet technology as a proposal for heat recovery from low-temperature sources
PublicationA tendency to increase the importance of so called dispersed generation, based on the local energy sources and the working systems utilizing both the fossil fuels and the renewable energy resources is observed nowadays. Generation of electricity on industrial or domestic scale together with production of heat can be obtained for example through employment of the ORC systems. It is mentioned in the EU directive 2012/27/EU for cogenerative...
-
Ranking of ecotoxisity tests for underground water assessment using the Hasse diagram technique
PublicationThe present study deals with the novel application of the Hasse diagram technique (HDT) for the specific ranking of ecotoxicity tests capable of assessment of underground water quality. The area studied is a multi-municipal landfill in the northern Poland. The monitoring network of the landfill constitutes of 27 piezometers for underground water monitoring and two observation points at surface water courses. After sampling, chemical...
-
Experimental and Computational Fluid Dynamics Studies on Straight and U-Bend Double Tube Heat Exchangers with Active and Passive Enhancement Methods
PublicationIn this work, the authors wanted to demonstrate the possibility to increase the heat transfer efficiency by using simple wire coil inserts to create turbulent flow in the boundary layer as well as air blowing into the annulus of the pipe. Experimental investigations were carried out for four heat exchanger constructions, i.e., plain double tube, turbulized double tube, plain U-bend double tube, U-tube with turbulator, plain double...
-
An advanced thermal-FSI approach of an evaporation of air heat pump
PublicationThe paper presents selected problems of numerical modeling of an advanced thermal-FSI approach of evaporator of air heat pomp. The example of a fin-tube evaporator has been studied, focusing on obtaining of heat exchanger characteristics applying two-phase flow model for the in-tube refrigerant flow. Special attention is given to heat transfer between separated medium for different air velocity and changed refrigerant mass flow...
-
Parametric study of fluid flow and heat transfer over louvered fins of air heat pump evaporator
PublicationTwo-dimensional numerical investigations of the fluid flow and heat transfer have been carried out for the laminar flow of the louvered fin-plate heat exchanger, designed to work as an air-source heat pump evap- orator. The transferred heat and the pressure drop predicted by simulation have been compared with the corresponding experimental data taken from the literature. Two dimensional analyses of the louvered fins with varying...
-
An inverse algorithm for contact heat conduction problems with an interfacial heat source based on a first-order thermocouple model
PublicationInverse problems of contact heat conduction with an interfacial heat source are common in various fields of science, engineering and technology. In this study, an algorithm for their solution is developed based on an inverse parametric optimisation method with an impulse response function describing the heat partition and contact heat transfer. A first-order thermocouple model with a time constant parameter is embedded in the impulse...
-
Microjet technology as a perspective intensification method for high performance heat exchangers
PublicationIn the paper two oryginal designs of compact heat exchangers with intensification effect produced by microjets are presented. The technology of microjets manufacturing is an "inhouse" patented design. The idea of such heat exchanger is shown together with the flow and thermal characteristics of the prototypes. The results of performer measurements are satisfactory and encourage for further research of the original designs.
-
Particle Shape Effect on Macroscopic Behaviour of Underground Structures: Numerical and Experimental Study
PublicationAbstract: The mechanical performance of underground flexible structures such as buried pipes or culverts made of plastics depend not only on the properties of the structure, but also on the material surrounding it. Flexible drains can deflect by 30% with the joints staying tight, or even invert. Large deformations of the structure are difficult to model in the framework of Finite Element Method, but straightforward in Discrete...
-
Particle Shape Effect on Macroscopic Behaviour of Underground Structures: Numerical and Experimental Study
PublicationThe mechanical performance of underground flexible structures such as buried pipes or culverts made of plastics depend not only on the properties of the structure, but also the material surrounding it. Flexible drains can deflect by 30% with the joints staying tight, or even invert. Large deformations of the structure are difficult to model in the framework of Finite Element Method, but straightforward in Discrete Element Methods....
-
Subjective Quality Evaluation of Underground BPL-PLC Voice Communication System
PublicationDesigning a reliable voice transmission system is not a trivial task. Wired media, thanks to their resistance to mechanical damage, seem an ideal solution. The BPL-PLC (Broadband over Power Line – Power Line Communication) cable is resilient to electricity stoppage and partial damage of phase conductors. It maintains continuity of transmission in case of an emergency situation, including paramedic rescue operations. These features...
-
High-temperature heat pumps – potential technology for heat recovery and production of process heat
PublicationIn the paper, the high temperature vapour compressor based heat pump with a selection of working fluids, both perspective and ecological ones, is considered. Such system is not yet commercially available on the market and in author’s opinion it has significant potential for various applications. In the presented analysis it was assumed that the heat source has a temperature of 50oC and the temperature lift is 60, 80 and 100K respectively....
-
Comparison of various flow maldistribution quantification methods in mini heat exchangers
PublicationThe aim of study is to compare various flow maldistribution quantification methods, using velocity, mass flow rate, pressure, and temperature. An experimentally validated numerical study has been prepared and a heat exchanger with 34 semi-circular channels with a diameter of 3.1 mm has been tested. The minichannels were heated from the bottom with a heat flux of 50, 60, 70, and 80 kW/m2. The cases for various inlet velocities of...