Filters
total: 66
Search results for: analyte concentration
-
Molecularly imprinted polymers applied in capillary electrochromatography and electrophoresis techniques
PublicationMolecularly imprinted polymers (MIPs) are synthetic materials with predetermined selectivity for a particular analyte or group of structure-linked chemicals which make them an ideal separation component. The process of developing and applying new types of MIPs in the field of environmental analytical chemistry has been broadly discussedi n many scientific studies in recent years. The use of new types of MIP sorbents as unique sorption...
-
Detection of the Plant Pathogen Pseudomonas Syringae pv. Lachrymans on Antibody-Modified Gold Electrodes by Electrochemical Impedance Spectroscopy
PublicationThe present work describes an impedimetric immunosensor for Pseudomonas syringae pv. lachrymans (Psl) detection. This pathogen infects many crop species causing considerable yield losses, thus fast and cheap detection method is in high demand. In the assay, the gold disc electrode was modified with 4-aminothiophenol (4-ATP), glutaraldehyde (GA), and anti-Psl antibodies, and free-sites were blocked with bovine serum albumin (BSA)....
-
Green aspects, developments and perspectives of liquid phase microextraction techniques
PublicationDetermination of analytes at trace levels in complex samples (e.g. biological or contaminated water or soils) are often required for the environmental assessment and monitoring as well as for scientific research in the field of environmental pollution. A limited number of analytical techniques are sensitive enough for the direct determination of trace components in samples and, because of that, a preliminary step of the analyte...
-
Ionic liquids-based microextraction techniques
PublicationIn recent years, the development of highly efficient analytical techniques is of great importance, however, the direct analysis of complex sample matrix is still impossible in many cases. Therefore, the step of sample preparation is commonly involved in an analytical procedure. Over the years, it has been realized that the major source of inaccuracy and imprecision on general analysis results from the operations associated to sample...
-
Boron-doped diamond nanosheet volume-enriched screen-printed carbon electrodes: a platform for electroanalytical and impedimetric biosensor applications
PublicationThis paper focuses on the development of a novel electrode based on boron-doped diamond nanosheet full-volume-enriched screen-printed carbon electrodes (BDDPE) for use as an impedimetric biosensor. Impedimetric biosensors offer high sensitivity and selectivity for virus detection, but their use as point-of-care devices is limited by the complexity of nanomaterials’ architecture and the receptor immobilisation procedures. The study...
-
Unlocking the electrochemical performance of glassy carbon electrodes by surface engineered, sustainable chitosan membranes
PublicationChitosan coatings, derived from crustacean shell waste, possess inherent biocompatibility and biodegradability, rendering them suitable for various biomedical and environmental applications, including electrochemical biosensing. Its amine and hydroxyl functional groups offer abundant sites for chemical modifications to boost the charge transfer kinetics and provide excellent adhesion, enabling the construction of robust electrode-coating...
-
Recent developments and future trends in solid phase microextraction techniques towards green analytical chemistry
PublicationSolid phase microextraction find increasing applications in the sample preparation step before chromatographic determination of analytes in samples with a complex composition. These techniques allow for integrating several operations, such as sample collection, extraction, analyte enrichment above the detection limit of a given measuring instrument and the isolation of analytes from sample matrix. In this work the information about...
-
Engineering boron and nitrogen codoped carbon nanoarchitectures to tailor molecularly imprinted polymers for PFOS determination
PublicationPer- and polyfluoroalkyl substances (PFAS) have gained significant attention as emerging contaminants due to their persistence, abundance, and adverse health effects. Consequently, the urgent need for ubiquitous and effective sensors capable of detecting and quantifying PFAS in complex environmental samples has become a priority. In this study, we present the development of an ultrasensitive molecularly imprinted polymer (MIP)...
-
Discriminating macromolecular interactions based on an impedimetric fingerprint supported by multivariate data analysis for rapid and label-free Escherichia coli recognition in human urine
PublicationThis manuscript presents a novel approach to address the challenges of electrode fouling and highly complex electrode nanoarchitecture, which are primary concerns for biosensors operating in real environments. The proposed approach utilizes multiparametric impedance discriminant analysis (MIDA) to obtain a fingerprint of the macromolecular interactions on flat glassy carbon surfaces, achieved through self-organized, drop-cast,...
-
Measurements of Activity Coefficients at Infinite Dilution for Organic Solutes in the Ionic Liquids N-Ethyl- and N-Octyl-N-methylmorpholinium Bis(trifluoromethanesulfonyl)imide. A Useful Tool for Solvent Selection
PublicationIn recent years, many papers describing ionic liquids (IL) as promising solvents in separation techniques have been published. The conscious choice of appropriate ionic liquid as absorption media in effective extraction of selected types of analytes requires deeper understanding of the analyte−IL interactions. Therefore, intensive research is conducted to determine the values of activity coefficient at infinite dilution, which...
-
Comparison of classical and modern approach of determination of highly polar compounds by High Performance Liquid Chromatography coupled with Tandem Mass Spectrometry
PublicationAbstract: Sugars and sugar alcohols are known as highly polar compounds. Four analytes were taken into consideration for comparison of classical and modern approach of separation of highly polar substances. Mannitol was chosen as an example of simple sugar alcohol, sucrose and lactulose as examples of disaccharides and structural isomers, raffinose as an example of complex trisaccharide. Raffinose was also used as internal standard...
-
Long-Term Stability of Benzodiazepines and Z-Hypnotic Drugs in Blood Samples Stored at Varying Temperatures
PublicationBenzodiazepines (BZDs) and Z-drugs are among the most commonly prescribed pharmaceuticals in the world and are considered standard care for various mental illnesses and for treatment of sleeping and anxiety disorders, alcohol withdrawal, muscle spasms and epilepsy. Some BZDs are not allowed as pharmaceuticals in many countries, and they are used as "designer benzodiazepines" (DBZDs). All these compounds are typically screened in...
-
Screening evaluation of the quality of commercially available cigars, cigarillos, and bidis based on emission levels of selected terpenes and terpenoids
PublicationThe aim of the research was to verify the use of the solvent-free, non-destructive and easy to operate analytical method to study and compare the emissions of 16 representatives of terpenes and terpenoids from commercially available cigars, cigarillos and bidis − a potential screening analysis for the quality of combustible tobacco products. To assess the amount of organic compounds emitted to the gaseous phase from investigated...
-
Electrochemical performance of indium-tin-oxide-coated lossy-mode resonance optical fiber sensor
PublicationAnalysis of liquids performed in multiple domain, e.g., optical and electrochemical (EC), has recently focus significant attention. Our previous works have shown that a simple device based on indium-tin-oxide (ITO) coated optical fiber core may be used for optical monitoring of EC processes. At satisfying optical properties and thickness of ITO a lossy-mode resonance (LMR) effect can be obtained and used for monitoring of optical...
-
Gold nanocubic structures agglomeration when put on conductive surfaces
Open Research DataThis dataset contains Dynamic EIS results obtained for the gold electrodes with non-functionalized gold nanocubes (AuNC) deposited at its surface. The deposition was the following: 2 uL of the solvent containing CTAB as the surfactant was put on the electrode and dried, the same procedure was applied 5 times. Afterward, the electrode was immersed in...
-
Gold nanocubic structures agglomeration when put on conductive surfaces
Open Research DataThis dataset contains Dynamic EIS results obtained for the gold electrodes with non-functionalized gold nanocubes (AuNC) deposited at its surface. The deposition was the following: 2 uL of the solvent containing CTAB as the surfactant was put on the electrode and dried, the same procedure was applied 5 times. Afterward, the electrode was immersed in...