Filters
total: 1836
-
Catalog
- Publications 1135 available results
- Journals 16 available results
- Conferences 2 available results
- Publishing Houses 1 available results
- People 35 available results
- Inventions 7 available results
- Projects 8 available results
- Laboratories 2 available results
- Research Teams 1 available results
- Research Equipment 7 available results
- e-Learning Courses 44 available results
- Events 3 available results
- Open Research Data 575 available results
displaying 1000 best results Help
Search results for: camera%20array
-
Milicz 2019 - video data - pedestrian, bicycles, vehicles
Open Research DataMilicz 2019 - video data - pedestrian, bicycles, vehicles
-
Stargard 2021- video data - pedestrian, bicycles, vehicles
Open Research DataStargard 2021- video data - pedestrian, bicycles, vehicles
-
Kolbudy 2021 W- video data - pedestrian, bicycles, vehicles
Open Research DataKolbudy 2021 W - video data - pedestrian, bicycles, vehicles
-
Natalia Chamera
People -
Amira El-Yazbi PhD
People -
Badania eksperymentalne kryzysu wrzenia w kanałach o małej średnicy
PublicationW pracy przedstawiono badania eksperymentalne kryzysu wrzenia II rodzaju (typu dryout) w kanałach o małej średnicy. Badania prowadzone były w rurach pionowych o średnicy wewnętrznej 1.15 mm i 2.3 mm, w których czynnikiem roboczym były dwa płyny niskowrzące, tj. R123 i SES36. W badaniach wysychania filmu cieczowego na ściance kanału wykorzystano nowoczesne techniki pomiaru rozkładu temperatury przy użyciu kamery termowizyjnej. Na...
-
FPGA and ASIC implementation of the algorithm for traffic monitoring in urban areas
PublicationW artykule przedstawiono algorytm detekcji obrazu oraz jego realizację sprzętową w technikach FPGA i ASIC. Algorytm ten dedykowany jest do detekcji ruchu pojazdów i jest realizowany w czasie rzeczywistym. Użyto pojedynczą, umieszczoną na stałe kamerę monochromatyczną o niskiej rozdzielczości. Wykonywane są również operacje eliminacji cieni i rozjaśnień obrazu. Nachodzenie obiektów na siebie nie jest brane pod uwagę. Realizacja...
-
Określanie konwekcyjnych strat ciepła z pionowych powierzchni budynków za pomocą nowej metody.
PublicationW artykule przedstawiono nową metodę pomiaru strumieni strat ciepła za pomocą kamery termowizyjnej wykorzystywanej dotychczas jedynie do badań jakościowych, zwłaszcza do wskazywania miejsc występowania strat ciepła (wewnętrzne ubytki izolacji, mostki cieplne, nieszczelności stolarki budowlanej itd.). Zaproponowana metoda, powstała na podstawie analizy pól temperatur w powietrzu, w oparciu o równanie Fouriera, pozwala nie tylko...
-
SYSTEM WIZYJNY DO OBRAZOWANIA POŁOŻENIA PRZESTRZENNEGO OBIEKTU TYPU OSTROSŁUP
PublicationW referacie przedstawiono system wizyjny, umożliwiający pomiar i wizualizację położenia ostrosłupa na scenie. System wykorzystuje stanowisko laboratoryjne Katedry Metrologii i Systemów Informacyjnych na Wydziale Elektrotechniki i Automatyki Politechniki Gdańskiej. Stanowisko pomiarowe składa się z następujących elementów: kamery cyfrowej wraz z obiektywem, wyposażonej w interfejs FireWire, zestawu oświetlaczy i komputera osobistego...
-
Metody pomiaru temperatury przedmiotów i ściernicy w procesie szlifowania jednotarczowego
PublicationW referacie przedstawiono metody pomiaru temperatury w szlifowaniu jednotarczowym z kinematyką docierania. W opracowanym rozwiązaniu wykorzystano małe, zasilane bateryjnie przyrządy rejestrujące temperaturę, tzw. logery pastylkowe o symbolu DS1922L produkcji firmy Dallas Semiconductor. Do pomiarów temperatury wykorzystano również kamerę termowizyjną. Zastosowanie czujników termoelektrycznych pozwoliło zarejestrować temperaturę...
-
Elastoplastic nonlinear FEM analysis of FGM shells of Cosserat type
PublicationThe paper is a continuation of [1] where the formulation of the elastic constitutive law for functionally graded materials (FGM) on the grounds of nonlinear 6-parameter shell theory with the 6th parameter (the drilling degree of freedom) was presented. Here the formulation is extended to the elasto-plastic range. The material law is based on Cosserat plasticity and employs the well-known Tamura-Tomota-Ozawa (TTO) [2] mixture...
-
Interferometric optical fiber sensors with active stabilization of the operating point using a tunable semiconductor laser. Optical Fibres and Their Applications VIII.
PublicationW pracy przedstawiono wyniki badań światłowodowych interferometrycznych sensorów siły wykonanych w konfiguracji interferometru Michelsona i wykorzystujących aktywną stabilizację punktu pracy przy pomocy zmiany długości fali źródła. Porównano dwie klasy omawianych sensorów a następnie zrealizowano sensor. W konstrukcji sensora zastosowano modulator z pośrednim pomiarem siły. Mierzona siła jest zamieniana na ciśnienie hydrostatyczne,...
-
Diagnostics of cvd process by means of optical emission spectroscopy.
PublicationZastosowano optyczną spektroskopię emisyjną do badania w trybie in-situ dysocjacji cząsteczek oraz wzbudzenia i jonizacji atomów wodoru podczas procesu syntezy cienkich warstw diamentowych metodą chemicznego osadzania z par gazowych wspomaganego plazmą mikrofalową (mPACVD). Zbudowano tor światłodowy, umożliwiający sprzężenie komory CVD z systemem spektroskopowym i wykonywanie pomiarów bezinwazyjnych. Wykonano pomiary spektralne...
-
Diagnostyka procesu CVD metodą optycznej spektroskopii emisyjnej. Diagnostics of CVD process by means of optical emission spectroscopy.
PublicationZastosowano optyczną spektroskopię emisyjną do badania w trybie in-situ dysocjacji cząsteczek oraz wzbudzenia i jonizacji atomów wodoru podczas procesu syntezy cienkich warstw diamentowych metodą chemicznego osadzania z par gazowych wspomaganego plazmą mikrofalową (mPACVD). Zbudowano tor światłowodowy, umożliwiający sprzężenie komory CVD z systemem spektroskopowym i wykonywanie pomiarów bezinwazyjnych. Wykonano pomiary spektralne...
-
Simulation of ship turning circle test for ballast and full load conditions
Open Research DataThe data show the results of the turning circle spiral test for the simplified ship model, taking into account two states of loading: ballast and full load. During the circulation test, the manoeuvrability of the vessel is tested.
-
Simulation of ship spiral test for ballast and full load conditions
Open Research DataThe data show the results of the spiral test for the simplified ship model, taking into account two states of loading: ballast and full load. The data set contains the results of time simulation for sea state 10 on the Beaufort scale: changes in rudder angle delta_tab[deg]; angular velocity r_tab[deg/s]; surge velocity u_tab (m/s); sway velocity v_tab...
-
Microbial community development on the surface of Hans and Werenskiold Glaciers (Svalbard, Arctic): a comparison
Publication -
Coprinopsis rugosomagnispora: a distinct new coprinoid species from Poland (Central Europe)
Publication -
Large‐Scale Traveling Ionospheric Disturbances Over the European Sector During the Geomagnetic Storm on March 23–24, 2023: Energy Deposition in the Source Regions and the Propagation Characteristics
PublicationMultiple Large-Scale Traveling Ionospheric Disturbances (LSTIDs) are observed in the European sector in both day-time and night-time during the magnetic storm on March 23–24, 2023. The Total Electron Content (TEC) observation from a network of GNSS receivers shows the propagation of LSTIDs with amplitudes between around 0.5 and 1 TECU originating from auroral and polar cusp regions down to southern Europe (35°N) with velocities...
-
The changes of crosslink density of polyurethanes synthesised with using recycled component. Chemical structure and mechanical properties investigations.
PublicationThis paper aims at the utilisation of glycerolysate (Gly) obtained in polyurethane recycling process by means of crude glycerine, which has in its structure hydroxyl end groups that allow for further processing. Polyurethanes (PUs) were synthesised using prepolymer method with the mixture of neat polyol and glycerolysate, in different ratios, with 4,4-diphenylmethane diisocyanate (MDI). The prepolymer was subsequently extended...
-
Quantitative study of free convective heat losses from thermodynamic partitions using Thermal Imaging
PublicationThe following paper presents a simple method of determining the presence, distribution and values of heat losses from external building walls as thermodynamic partitions using a Thermal Imaging Camera (TIC). According to Fourier's equation, the value of heat loss is proportional to the temperature gradient ∂t/∂y|y=0 in air in the y direction perpendicular to the heated surface. Unfortunately, air temperature cannot be measured...
-
Detecting Apples in the Wild: Potential for Harvest Quantity Estimation
PublicationKnowing the exact number of fruits and trees helps farmers to make better decisions in their orchard production management. The current practice of crop estimation practice often involves manual counting of fruits (before harvesting), which is an extremely time-consuming and costly process. Additionally, this is not practicable for large orchards. Thanks to the changes that have taken place in recent years in the field of image...
-
Calibration images under different lighting conditions vol. 1
Open Research DataDataset description: Calibration images under different lighting conditions vol. 1
-
Video DATA - Traffic generation modeling for discount shops - Rakoczego Street
Open Research DataThe data includes video traffic data (vehicles, pedestrians, cyclists) registered at 21 Rakoczego street in Gdansk. The data covers the day 01.10.2020 at 6:00-10:00. The video camera was installed niearby the parking area belonging to the discount store Lidl. The data obtained was used in analysis, providing information about the modal split and the...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,75 V at 241 mA. Sample 24, run #3.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,75 V and discharged to 10 mV by constant current 241 mA, experiment run #3The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,75 V at 241 mA. Sample 24, run #5.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,75 V and discharged to 10 mV by constant current 241 mA, experiment run #5.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,8 V at 241 mA. Sample 24, run #1.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,8 V and discharged to 10 mV by constant current 241 mA, experiment run #1.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,0 V at 250 mA. Sample 24.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,0 V and discharged to 10 mV by constant current 250 mA. Last experiment with sample 24The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,5 V at 180 mA. Sample 24
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,5 V and discharged to 10 mV by constant current 180 mA. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface emission....
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 80 mA. Sample 41.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 80 mA. Sample 41.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,75 V at 241 mA. Sample 24, run #2.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,75 V and discharged to 10 mV by constant current 241 mA, experiment run #2The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,0 V at 250 mA. Sample 23, run #1.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,0 V and discharged to 10 mV by constant current 250 mA. Sample 23, experiment run #1.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,8 V at 241 mA. Sample 24, run #2.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,8 V and discharged to 10 mV by constant current 241 mA, experiment run #2.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,8 V at 241 mA. Sample 24, run #3.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,8 V and discharged to 10 mV by constant current 241 mA, experiment run #3.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,9 V at 241 mA. Sample 24, run #1.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,9 V and discharged to 10 mV by constant current 241 mA, experiment run #1.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,5 V at 241 mA. Sample 24
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,5 V and discharged to 10 mV by constant current 241 mA. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface emission....
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,0 V at 250 mA. Sample 23, run #2.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,0 V and discharged to 10 mV by constant current 250 mA. Sample 23, experiment run #2.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,5 V at 80 mA. Sample 24
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,5 V and discharged to 10 mV by constant current 80 mA. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface emission....
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,75 V at 241 mA. Sample 24, run #4.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,75 V and discharged to 10 mV by constant current 241 mA, experiment run #4.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,75 V at 241 mA. Sample 24, run #1.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,75 V and discharged to 10 mV by constant current 241 mA. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface emission....
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,9 V at 241 mA. Sample 24, run #2.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,9 V and discharged to 10 mV by constant current 241 mA, experiment run #2.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,5 V at 301 mA. Sample 24
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,5 V and discharged to 10 mV by constant current 301 mA. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface emission....
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 160 mA. Sample 41.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 160 mA. Sample 41.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,5 V at 120 mA. Sample 24
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,5 V and discharged to 10 mV by constant current 120 mA. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface emission....
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,1 V at 561 mA. Sample 71, run #3.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,1 V and discharged to 10 mV by constant current 561 mA. Sample 71, experiment run #3.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 112 mA. Sample 71.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 112 mA. Sample 71.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,1 V at 561 mA. Sample 71, run #4.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,1 V and discharged to 10 mV by constant current 561 mA. Sample 71, experiment run #4.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 108 mA. Sample 61.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 108 mA. Sample 61.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 204 mA. Sample 51, run #7.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 204 mA. Experiment run #7. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 135 mA. Sample 61.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 135 mA. Sample 61.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...