Permeation passive sampling as a tool for the evaluation of indoor air quality
PublicationOkreślono stężenie średnie ważone w czasie wybranych lotnych związków organicznych w powietrzu ośmiu pomieszczeniach mieszkalnych na terenie miasta Gdańska. Do pobierania próbek analitów z powietrza wewnętrznego zastosowano permeacyjny dozymetr pasywny typu pudełkowego oraz technikę dynamiczną (urządzenie przepływowe z rurką sorpcyjną). Porównano wyniki uzyskane w wyniku zastosowania w/w technik pobierania próbek analitów.
-
An Empirical Model for the Polarisation Characteristics of Indoor Off-Body Channels
PublicationThis paper presents an analysis of the polarisation characteristics for the channel in dynamic off-body communications, and an empirical channel model, based on measurements performed at 2.45 GHz in an office environment. Body presence and propagation conditions have a strong influence on signal depolarisation. The model assumes three components for the total path loss: mean path loss, represented by a log-distance function with...
-
Screening of volatile organic compounds as a source for indoor pollution
PublicationLotne związki organiczne (VOC) stanowią jedne z istotniejszychzanieczyszczeń powietrza wewnętrznego, ich stężenia w powietrzu wewnętrznym są często kilkakrotnie wyższe niż odpowiadające im stężenia w powietrzu zewnętrznym. Ten niekorzystny stosunek stężeń wskazuje na obecność endogennych źródeł emisji (usytuowanych bezpośrednio wewnątrz budynków). Lotne związki organiczne uwalniane są do powietrza wewnętrznego z wielu kontrolowanych...
-
Visual Detection of People Movement Rules Violation in Crowded Indoor Scenes
PublicationThe paper presents a camera-independent framework for detecting violations of two typical people movement rules that are in force in many public transit terminals: moving in the wrong direction or across designated lanes. Low-level image processing is based on object detection with Gaussian Mixture Models and employs Kalman filters with conflict resolving extensions for the object tracking. In order to allow an effective event...
-
Occurrence and levels of polybrominated diphenyl ethers (PBDEs) in house dust and hair samples from Northern Poland; an assessment of human exposure
PublicationPolybrominated diphenyl ethers (PBDEs) are among most ubiquitous compounds to be found in indoor environment and ingestion of household dust is considered an important route of exposure to PBDEs, especially in toddlers and young children. The present work reported concentration levels of PBDE congeners (PBDE-28, -47, -99, -100, -153, -154, -183 and -209) in hair and dust samples from selected households from Northern Poland. The...
-
Adaptive system for recognition of sounds indicating threats to security of people and property employing parallel processing of audio data streams
PublicationA system for recognition of threatening acoustic events employing parallel processing on a supercomputing cluster is featured. The methods for detection, parameterization and classication of acoustic events are introduced. The recognition engine is based onthreshold-based detection with adaptive threshold and Support Vector Machine classifcation. Spectral, temporal and mel-frequency descriptors are used as signal features. The...
-
House dust as a source of analytical information on concentration of polybrominated diphenyl ethers (PBDEs) - first approach
PublicationPolybrominated diphenyl ethers (PBDEs), which are best recognized as flame retardants, were in 2001, by virtue of Stockholm Convention, listed in a group of Persistent Organic Compounds (POPs). Increasing concentration levels of PBDEs, reported in human tissues (e.g., blood, serum, breast milk, etc.) haverecently caught worldwide concern due to their potential tendency to disrupt thyroid hormones, neurobehavioral deficits and endocrine...
-
Measuring research on radio wave propagation
PublicationTelecommunication connections are increasingly based on the wireless links, both fixed and mobile, carried out under different radio systems. This kind of solution has many advantages. However, the propagation medium is a factor that causes many difficulties in designing wireless networks, because of large diversity of propagation environments. Transmission loss in each environment is determined by many variables phenomena and...
-
Determination of polybrominated diphenyl ethers in house dust using standard addition method and gas chromatography with electron capture and mass spectrometric detection
PublicationMonitoring of the environmental fate of polybrominated diphenyl ethers (PBDEs) involves determination of their concentration in air, airborne particles and settled dust. This requires the implementation of appropriate analytical tools like measuring instruments, reference materials and analytical procedures. In this study an analytical procedure was developed for determining PBDEs in samples with a complex matrix composition. The...
-
New Materiality-towards ‘Media Environments
PublicationArticle presents media solutions providing new materiality of architectural spaces. Media solutions in architecture evolve in new forms. Articlepresentsboth the developmentof new technological solutionsas well as new ways of application of media solutions in relation toarchitectural form. The aim of the article is to show technical aspects of new materiality - intelligent materials, allowing transmission of changeable visual content...
-
Badanie i analiza efektywności alokacji strumieni danych w heterogenicznej sieci WBAN
PublicationW niniejszej dysertacji doktorskiej poddano dyskusji efektywność alokacji strumieni danych w heterogenicznej radiowej sieci WBAN (Wireless Body Area Networks). Biorąc pod uwagę dynamiczny rozwój nowoczesnych sieci radiokomunikacyjnych piątej generacji (5G), którego część stanowią radiowe sieci działające w obrębie ciała człowieka, bardzo ważnym aspektem są metody maksymalizujące wykorzystanie dostępnych zasobów czasowo –częstotliwościowych...
-
Electronic Noses for Indoor Air Quality Assessment
PublicationThis chapter presents a proposal of the use of electronic noses in the monitoring of indoor air quality. The main focus is put on the detailed characteristics of today’s indoor air quality control methods, the types of pollution in the air, and the development of electronic noses for air testing. Currently, scientists seek methodological and structural solutions that would enable real-time online indoor air control. It has been...
-
Biocomposites from recycled resources as candidates for laboratory reference material to validate analytical tools used in organic compounds emissions investigation
PublicationA suitably chosen reference material should meet specific criteria like representing one of the compound classes most commonly occurring in indoor materials as well as having optimal long-term stability during storage and transport to its destination point and having a compact size. The described interdisciplinary pilot research was aimed to develop and characterize a polymer-based candidate for the laboratory reference material...
-
Computational and experimental evaluation of view out according to European Standard EN17037.
PublicationThis paper presents an experimental evaluation of view out based on EN17037:2018 Daylight in Buildings within an educational building. The primary motivation to conduct the research was an introduction of a view out appraisal criteria by the mentioned standard. The study gives insights into the following: (i) the use of computational evaluation of an outside view according to the EN17037 criteria (ii) the use of the direct simultaneous...
-
The Use of Sensory Analysis Techniques to Assess the Quality of Indoor Air
PublicationThe quality of indoor air is one of the significant elements that influences people's well-being and health inside buildings. Emissions of pollutants, which may cause odor nuisance, are the main reason for people's complaints regarding the quality of indoor air. As a result, it is necessary to perform tests aimed at identifying the sources of odors inside buildings. The article contains basic information on the characteristics...
-
Miniaturized Passive Emission Chambers for In Situ Measurement of Emissions of Volatile Organic Compounds
PublicationThe results of many different studies have demonstrated unequivocally that the quality of indoor air is often much worse than that of atmospheric air. The presence of dangerous chemical compounds in indoor air can have an adverse impact on human health and cause numerous diseases of the respiratory and circulatory systems. Such harmful chemicals get into indoor air as a result of their emission from building and indoor materials....
-
The miniaturised emission chamber system and home-made passive flux sampler studies of monoaromatic hydrocarbons emissions from selected commercially-available floor coverings
PublicationThe estimation of the emission rate of organic compounds released from various types of indoor materials can be performed using stationary environmental test chambers (ETC) classified as ex-situ methods or small-scale portable analytical devices based on the use of passive technique at the stage of analytes sampling from the gaseous phase (in-situ methods). The paper presents results of emissions of selected organic compounds from...
-
Badania jakości usług szybkiej transmisji danych z wykorzystaniem turbokodowania w systemie UMTS.
PublicationW referacie przedstawiono budowę kodera oraz dekodera turbokodu pracującego w oparciu o algorytm SOVA w systemie radiokomunikacyjnym trzeciej generacji UMTS. Omówiono wyniki badańsymulacyjnych jakości transmisji z szybkością 384 kb/s z wykorzystaniem turbokodowania. Badania przeprowadzono dla obu kierunków transmisji w środowiskach Indoor Office B oraz Outdoor to Indoor & Pedestrian B.
-
Badania jakości usług szybkiej transmisji danych z wykorzystaniem turbokodowania w systemie UMTS.
PublicationW pracy przedstawiono budowę kodera oraz dekodera turbokodu pracującego w oparciu o algorytm SOVA w systemie radiokomunikacyjnym trzeciej generacji UMTS. Omówiono wyniki badań symulacyjnych jakości transmisji z szybkością 384 kb/s z wykorzystaniem turbokodowania. Badania przeprowadzono dla obu kierunków transmisji w środowiskach Indoor Office B oraz Outdoor to Indoor & Pedestrian B.
-
A Review of Antennas for Indoor Positioning Systems
PublicationThis paper provides a review of antennas applied for indoor positioning or localization systems. The desired requirements of thoseantennas when integrated in anchor nodes (reference nodes) are discussed, according to different localization techniques and theirperformance. The described antennas will be subdivided into the following sections according to the nature of measurements:received signal strength (RSS), time of flight (ToF),...
-
Performance analysis of an rfid-based 3d indoor positioning system combining scene analysis and neural network methods
PublicationThe main purpose of this research is to improve localization accuracy of an active Radio Frequency Identification, RFID tag, in 3D indoor space. The paper presents a new RFID based 3D Indoor Positioning System which shows performance improvement. The proposed positioning system combines two methods: the Scene Analysis technique and Artificial Neural Network. The results of both simulation using Log-Distance Path Loss Model and...
-
Accuracy analysis of the RSSI BLE SensorTag signal for indoor localization purposes
PublicationIn this paper we describe possibility of use the RSSI signal (Radio Signal Strength Indication) from Texas Instruments SensorTag CC2650 for indoor positioning purposes. This idea is not a new but in our opinion it is possible to use SensorTags with Bluetooth LE wireless interface for positioning inside buildings in such applications as people findings in hospitals, senior come care, etc. RSSI is mostly selected as the sensor localization...
-
Natural ventilation performance of family building in cold climate during windy days
PublicationAdequately designed natural ventilation is the cheapest and easiest way to effectively remove indoor pollutants and keep the fresh air inside a building. A prediction of performance and effectiveness of ventilation in order to determine the design of a ventilation system can provide real and long term cost savings. The paper presents results of performance (air change rate ACH) and effectiveness (CO2 concentration in the breathing...
-
Fast Calibration-Free Single-Anchor Indoor Localization Based on Limited Number of ESPAR Antenna Radiation Patterns
Publication— In this article, we investigate how the calibrationfree single-anchor indoor localization algorithm developed for base stations equipped with electronically steerable parasitic array radiator (ESPAR) antennas can further be improved. By reducing the total number of ESPAR antenna radiation patterns used in localization process, one can significantly reduce the time needed for an object localization. Performed localization measurements...
-
Influence of a Radio Frequency on RF Fingerprinting Accuracy Based on Ray Tracing Simulation
PublicationIn this paper the influence of a radio signal frequency on performance of Indoor Positioning System based on fingerprinting has been examined using ray-tracing simulations. It has been simulated how spatial distribution of an RF signal strength change with the signal’s frequency. The results were used to show its’ impact on the behavior of localization algorithms that are employing RSS measurements to determine node’s position...
-
Analogue GPS repeater
PublicationThis article concerns the problem of difficulty in correct indoor Global Positioning System (GPS) signals reception due to attenuation. Radio signal repeaters are proposed as means to solve this problem. Firstly, the GPS signal characteristics are described, emphasizing their low power in the point of reception. In the second part, various applications of GPS signal repeater, where indoor GPS signals reception is required, are...
-
Single-Anchor Indoor Localization Using ESPAR Antenna
PublicationIn this paper a new single-anchor indoor localization concept employing Electronically Steerable Parasitic Array Radiator (ESPAR) antenna has been proposed. The new concept uses a simple fingerprinting algorithm adopted to work with directional main beam and narrow minimum radiation patterns of ESPAR antenna that scans 360° area around the base station, while the signal strength received from a mobile terminal is being recorded...
-
Chapter 8 – Active Sampling of Air
PublicationThis chapter reviews the literature information on analytical techniques and laboratory equipment used for active sampling of air (atmospheric and indoor) in regular monitoring research. It describes popular analytical devices applied for sample collection using various types of polymeric bags, e.g. Tedlar bags, Teflon or Nafion bags, and/or stainless steel vacuum containers. It reviews literature data about the application of...
-
Tracking body movement for radio channel measurements in BAN with indoor positioning system
PublicationThis paper presents indoor positioning system based on inertial navigation with additional distance measurements using UWB modems and map matching to increase accuracy and eliminate position drift. Such system may be used to track position of human body during radio channel measurements for body area networks. Performance of proposed system and limitations caused by inertial navigation are briefly described.
-
Porównanie efektywności kodów LDPC
PublicationW referacie zaprezentowano porównanie wyników badań symulacyjnych jakości transmisji z wykorzystaniem kodów LDPC w interfejsie radiowym systemu UMTS. Badania symulacyjne zostały przeprowadzone dla szybkości transmisji 144 kb/s w środowisku propagacyjnym Outdoor to Indoor & Pedestrian B. W referacie przedstawiono również zasadę działania i algorytmy dekodowania kodów LDPC.
-
Modelowanie dokładności radiolokalizowania w różnych warunkach środowiskowych przy wykorzystaniu interfejsu radiowego 5G-NR
PublicationW artykule przedstawiono wyniki eksperymentalnych badań dokładności estymacji położenia terminala użytkownika korzystającego~z interfejsu radiowego 5G-NR. W środowisku miejskim dokonano rejestracji rzeczywistych sygnałów sieci 5G, a następnie przeprowadzono badania numeryczne. Celem było zweryfikowanie różnic dokładności estymacji położenia w trzech różnych środowiskach: wewnątrz- i zewnątrzbudynkowym oraz tzw. deep-indoor.
-
Survey of Radio Navigation Systems
PublicationAt present, there is a growing demand for radio navigation systems, ranging from pedestrian navigation to consumer behavior analysis. These systems have been successfully used in many applications and have become very popular in recent years. In this paper we present a review of selected wireless positioning solutions operating in both indoor and outdoor environments. We describe different positioning techniques, methods, systems,...
-
Enhanced switched parasitic antenna with switched active monopoles for indoor positioning systems
PublicationThis paper presents the concept of enhanced reduced-size steerable antenna array with two rows of switched active and passive elements. Designed array is similar to ESPAR antenna but it has a set of switched monopoles instead of central one. It is intended for 2.4 GHz ISM applications with emphasis on indoor positioning systems (IPS). Proposed antenna provides improved radiation parameters and reduced dimensions in comparison to...
-
Monoterpenes emissions from different samples of wood-based materials – laminated chipboards and medium-density fiberboards (MDF)
PublicationThe paper presents the results of studies on emission rates of monoterpenes, carried out with the use of a new type of device - Markes’ Micro-Chamber/Thermal Extractor™ (μ-CTE250). Subject of studies were different types of wood-based materials such as: laminated chipboards and medium-density fiberboards (MDF). Based on the results obtained one can conclude that the laminated chipboards may affect the indoor air quality in much...
-
Employment of passive sampling in monitoring indoor air quality in selected residences in a Tri-city area in Poland
PublicationTime-weighted average concentrations of selected volatile compounds were measured in chosen residences in a Tri-City area of Poland by means of passive sampling. The results were compared to those obtained by dynamic technique – sorption tubes filled with Tenax TA sorbent. Results obtained by employing the two techniques were similar. Total volatile organic compound (TVOC) parameters were also determined. An attempt was also...
-
Badanie efektywności mechanizmu redukcji liczby iteracji turbodekodera w systemie UMTS
PublicationStreszczenie: W referacie przedstawiono budowę turbokodera zastosowanego w systemie UMTS i dekodera turbokodu z mechanizmem redukcji liczby iteracji wykorzystującym informację o przekroczeniu zadanego progu przez wielkość logarytmu stosunku prawdopodobieństw a-posteriori LLR w turbodekoderze Zostały porównane i omówione wyniki badań symulacyjnych dla obu kierunków transmisji w środowisku propagacyjnym miejskim wokoło-budynkowym...
-
Badania jakości turbodekodowania z mechanizmem redukcji liczby iteracji w systemie UMTS
PublicationW referacie została przedstawiona budowakodera oraz dekodera turbokodu pracującego w oparciuo algorytm SOVA z zastosowanym mechanizmem redukującymliczbę iteracji w systemie UMTS. Zostały porównanei omówione wyniki badań symulacyjnych przeprowadzonychdla obu kierunków transmisji w środowisku propagacyjnymOutdoor to Indoor & Pedestrian B dla trzech szybkościtransmisji danych 64 kb/s, 144 kb/s i 384 kb/s, w przypadkuzastosowania mechanizmu...
-
Investigation of the Dynamism of Nanosized SOA Particle Formation in Indoor Air by a Scanning Mobility Particle Sizer and Proton-Transfer-Reaction Mass Spectrometry
PublicationTerpenes are VOCs of particular importance, since they are emitted from a wide range of indoor sources and are considered to be precursors of Secondary Organic Aerosol (SOA) formation. It has been proven that SOA particles, especially nanosized ones, pose a threat to human health. In this research, experiments with the application of an environmental chamber and real-time measurement techniques were carried out to investigate in...
-
Currently Commercially Available Chemical Sensors Employed for Detection of Volatile Organic Compounds in Outdoor and Indoor Air
PublicationThe paper presents principle of operation and design of the most popular chemical sensors for measurement of volatile organic compounds (VOCs) in outdoor and indoor air. It describes the sensors for evaluation of explosion risk including pellistors and IR-absorption sensors as well as the sensors for detection of toxic compounds such as electrochemical (amperometric), photoionization and semiconductor with solid electrolyte ones....
-
Lightweight structures in architecture: scenarios for the future
PublicationLightweight structures - structures with a reduced weight, which otherwise retain the qualities necessary for the building performance, ensuring a proper durability and strength, safety, indoor environmental quality and energy efficiency; stuctures which strive for the optimization of structural systems - are in tune with current trends and socio-economic, environmental and technological factors. The growing interest in the lightweight...
-
Improved energy management technique in pipe-embedded wall heating/cooling system in residential buildings
PublicationEffective and environmentally responsive techniques of energy management in residential buildings are desirable for the resulting reduction of energy costs and consumption. In this paper, an improved and efficient technique of energy management in pipe-embedded wall heating/cooling systems, called the Thermal Barrier, is described. Specifically, the Thermal Barrier is a technique focused on the management and control of heat...
-
Improved energy management technique in pipe-embedded wall heating/cooling system in residential buildings
PublicationEffective and environmentally responsive techniques of energy management in residential buildings are desirable for the resulting reduction of energy costs and consumption. In this paper, an improved and efficient technique of energy management in pipe-embedded wall heating/cooling systems, called the Thermal Barrier, is described. Specifically, the Thermal Barrier is a technique focused on the management and control of heat supply...
-
UWB-Based Indoor Navigation in a Flexible Manufacturing System Using a Custom Quadrotor UAV
PublicationA novel solution for indoor navigation of a transportation drone in flexible manufacturing is presented in this paper. To address the challenges of accurate and robust drone navigation in occluded environments, an ultra-wideband (UWB) navigation system has been integrated with a commercially available open source control platform. The system offers high accuracy (± 20 mm), low power consumption, resistance to electronic interference,...
-
The home-made in situ passive flux sampler for the measurement of monoterpene emission flux: preliminary studies
PublicationThe paper presents the construction and metrological characteristics of the home-made in situ passive flux sampler, an analytical tool representing small-scale emission chambers working in situ and passively sampling analytes from the gaseous phase. The sorption element was a cylindrical container made of stainless steel net, packed with a carbon sorbent bed-graphitized charcoal, Carbograph 4 (35/50mesh). The recommended working/exposure...
-
Energy efficient indoor localisation for narrowband internet of things
PublicationThere are an increasing number of Narrow Band IoT devices being manufactured as the technology behind them develops quickly. The high co-channel interference and signal attenuation was seen in edge Narrow Band IoT devices make it challenging to guarantee the service quality of these devices. To maximize the data rate fairness of Narrow Band IoT devices, a multi-dimensional indoor localization model is devised, consisting of...
-
Application of Passive Samplers in Monitoring of Organic Constituents of Air
PublicationThe principles of passive dosimetry, which has been known for over 100 years, are finding an ever increasing use in analytical practice and are being used as a convenient technique for isolation and enrichment of analytes from various environmental media. Due to its simplicity, a variety of designs, as well as the possibility of using a number of different final determination techniques, passive dosimetry has been applied in...
-
Effect of band gap on power conversion efficiency of single-junction semiconductor photovoltaic cells under white light phosphor-based LED illumination
PublicationOn the basis of the detailed balance principle, curves of efficiency limit of single-junction photovoltaic cells at warm and cool white light phosphor-based LED bulbs with luminous efficacy exceeding 100 lm/W have been simulated. The effect of energy band gap and illuminance on the efficiencies at warm and cool light is discussed. The simulations carried out show that maximum power conversion efficiency at 1000 lx reaches 52.0%...
-
On the Usefulness of the Generalised Additive Model for Mean Path Loss Estimation in Body Area Networks
PublicationIn this article, the usefulness of the Generalised Additive Model for mean path loss estimation in Body Area Networks is investigated. The research concerns a narrow-band indoor off-body network operating at 2.45 GHz, being based on measurements performed with four different users. The mean path loss is modelled as a sum of four components that depend on path length, antenna orientation angle, absolute difference between transmitting...
-
Natural ventilation performance of family building in cold climate during windless time
PublicationIn this paper, the field measurements results are presented on the stack ventilation effect. The paper presents the results of performance (air change rate ACH) natural ventilation for building with inlet gap measured for the transitional season (between heating and summer season). The measurements were performed during a windless time. The house was located in northern Poland, in a cold climate region. The measurement system...
-
Chapter 11 – Application of Chemical Sensors and Sensor Matrixes to Air Quality Evaluation
PublicationIndoor and outdoor air quality is one of the key factors influencing human health. However, air quality evaluation is not easy task. Air is a complex system, which is subjected to changes even within short period of time. Progress in analytical methods and analytical tools provides increasingly more reliable information on the condition and quality of indoor and outdoor air. This progress, however, generates an increase in the...