displaying 1000 best results Help
Search results for: power system voltage stability
-
A Single-Carrier-Based Pulse-Width Modulation Template for Cascaded H-Bridge Multilevel Inverters
PublicationMultiplicity of the triangular carrier signals is a criterion for the extension of sinusoidal pulsewidth modulation, SPWM, to a number of output voltage levels per phase-leg in cascaded H-bridge (CHB) multilevel inverter (MLI). Considering medium and high voltage applications where appreciable number of output voltage levels from CHB MLI is needed, commensurate high number of carrier signals in either classical level- or phase-shifted...
-
Single-Phase 15-Level Switched-Capacitor Boost Multilevel Inverter Topology for Renewable Energy Applications
PublicationGalvanic isolation is a vital part of a grid-connected solar PV system. With the growth of multilevel inverters for grid-connected applications, the multilevel inverters having isolation are not sufficiently discussed in the literature. In this paper, a 15-level isolated multilevel inverter topology requiring only thirteen switches is proposed. The envisaged configuration includes two cells, designated as upper and lower cells....
-
Activity coordination of capacitor banks and power transformer controllers in order to reduce power losses in the MV grid
PublicationOne of the main issues related to the optimization of the MV (middle voltage) network is to reduce losses of active and reactive power. Lower losses of active and reactive power give not only economic advantage, but also improvement of energy quality. The object of regulation that can be used for these purposes are transformer with On-Load Tap Changer and capacitor's banks. This paper presents results of analysis of the possibility...
-
Neutral earthing reactor protection
PublicationThe IEEE and CIGRE recommend protection systems for high voltage shunt reactors. Unfortunately the recommendations do not include guidelines for the protection of neutral earthing reactors, which are often connected to shunt reactors to increase the effectiveness of single pole auto-reclosing. The paper discusses earthing reactor protection issues with particular emphasis on the detection of internal faults. An analysis carried...
-
AUTOMATED SYSTEM FOR FLUCTUATION ENHANCED GAS SENSING
PublicationResistance gas sensors exhibit random phenomena (resistance noise) which can be utilized to improve gas sensitivity and selectivity. That new emerging technique has to be investigated to recognize optimal parameters for gas detection. It means that a measurement system has to have ability of numerous parameters adjustment (e.g., sampling frequency, heater voltage, polarization current, voltage noise amplification). That fact induced...
-
Voltage Harmonics Transfer through Medium Voltage Instrument Transformers
PublicationVoltage transformers are widely used in power quality monitoring systems in medium and high voltage grids. This paper presents accuracy problems related to voltage harmonics transfer through instrument transformers. A simplified lumped-parameters wideband circuit model of the voltage transformer is proposed and verified by simulation and experimental investigations. A number of voltage transformers have been tested in the frequency...
-
Effect of solar radiation on current-carrying capacity of PVC-insulated power cables – the numerical point of view
PublicationPower cables are usually buried in the soil, which results in their relatively high current-carrying capacity. However, there are cases in which the starting/final section of a cable line runs along a pole of an overhead power line. Power cables can be directly exposed to solar radiation then, and this negatively influences their current-carrying capacity as well as estimated life of the cables’ insulation. An analysis of thermal...
-
Dynamic variables limitation for backstepping control of induction machine and voltage source converter
PublicationDynamic variables limitation for backstepping control of induction machine and voltage source converter The paper presents the method of control of an induction squirrel-cage machine supplied by a voltage source converter. The presented idea is based on an innovative method of the voltage source converter control, consisting in direct joining of the motor control system with the voltage source rectifier control system. The combined...
-
Risk of power cables insulation failure due to the thermal effect of solar radiation
PublicationLow-voltage, as well as high-voltage power cable lines, are usually buried in the ground. The ampacity of the power cables in the ground mainly depends on the thermal resistivity of the soil, which may vary in a wide range. A common practice in power cable systems performance is to supply them from a pole of an overhead line. If so, a section of the line is located in free air and can be directly exposed to solar radiation. In...
-
Study of prototype multi-pole non-salient field winding for high speed brushless synchronous generator
PublicationIn this paper a non-salient field winding for a brushless synchronous generator working with high speed in an autonomous energy generation system (e.g. airplane power grid) has been presented. A conception of a six-pole cylindrical-rotor with distributed field winding has been proposed. Comparison study of salient and prototype non-salient field winding has been carried out. Chosen simulation and measurement results of the generator...
-
Four level inverter's DC bus voltage balancing with 3-terminal DAB converter
Publication—Multilevel inverters become more and more popular, especially in the medium or high voltage and high power applications. Unfortunately, some of inverter topologies require additional DC bus voltage balancing systems. This paper presents a novel approach to such systems, which is based on a multiple terminal DAB converter. Along with the voltage balancing function the proposed solution enables the connection of energy storage devices...
-
Niskonapięciowy filtr analogowy CMOS wykorzystujący konwerter ujemnoimpedancyjny
PublicationA low-voltage 3-order low-pass CMOS filter based on the novel current inversion type negative impedance converter (CNIC) is presented. It shows a badwidth of 10 MHz at 400 uW power consumption and 2 V supply voltage when realized in a 0.35 um CMOS process.
-
Niskonapięciowy filtr analogowy CMOS oparty o konwerter ujemno-impedancyjny
PublicationA low-voltage 3-order low-pass CMOS filter based on the novel current inversion type negative impedance converter (CNIC) is presented. It shows a badwidth of 10 MHz at 400 uW power consumption and 2 V supply voltage when realized in a 0.35 um CMOS process.
-
Multi-Channel Virtual Instrument for Measuring Temperature—A Case Study
PublicationThe article presents the hardware and software configuration of the developed multi-channel temperature measurement system as well as calibration procedures and measurement results verifying the properties of measurement channels. The system has been developed and dedicated primarily for measuring the temperature distribution in a laboratory model simulating underground power lines. With the adopted configuration of the analog...
-
Symulacja pracy przesuwnika fazowego w sieci elektroenergetycznej przy połączeniu transformatora szeregowego w gwiazdę
PublicationPoniższy artykuł prezentuje sposób regulacji mocy czynnej i biernej za pomocą przesuwnika fazowego, którego uzwojenie transformatora dodawczego (szeregowego) jest połączone w gwiazdę. W artykule pokazano regulację mocy czynnej i biernej na przykładzie wybranego systemu elektroenergetycznego. Omawiany przesuwnik fazowy reguluje jednocześnie przepływem mocy czynnej i biernej w danym systemie elektroenergetycznym.
-
THREE-LEVEL F-TYPE INVERTER
PublicationGiven the recent available IGBT switch modules up to 6.5 kV, 1200 A rating, the prospect of the diode-free variant topology of the three-level neutral-point-clamped (3-level, T-type) inverter in certain medium voltage applications is bright; due to its small part count and low conduction losses compared to the diode-clamped NPC inverter. However, within this voltage range, the input dc voltage rating of 50% of the switches per...
-
Power Electronic Transformer For Smart Grid Application
PublicationIn this paper the control system of Power Electronic Transformer (PET) for the Smart Grid application is proposed. The structure of PET is based on two Cascaded H-bridge (CHB) converters. The electrical energy is transferred between converters using Dual-Active-Bridges (DAB) and high-frequency transformers. This type of coupling has been used to connect the DC-links of all H-bridges. The proposed control system for PET makes it...
-
Dual Active Bridge (DAB) DC-DC converter for multilevel propulsion converters for electrical multiple units (EMU)
PublicationSemiconductor power devices made from silicon carbide (SiC) reached a level of technology enabling their widespread use in power converters. Two different approaches to implementation of modern traction converters in electric multiple units (EMU) have been presented in recent years: (i) 3.3-kV SiC MOSFET-based three-level PWM inverter with regenerative braking and (ii) 6.5-kV IGBT-based four-quadrant power electronic traction transformer...
-
СИЛОВОЙ ПРЕОБРАЗОВАТЕЛЬ С АКТИВНЫМ ПОДАВЛЕНИЕМ ВЫСШИХ ГАРМОНИК ДЛЯ СИСТЕМ ЭЛЕКТРОСНАБЖЕНИЯ ЛЕТАТЕЛЬНЫХ АППАРАТОВ (Power converter with active suppression of higher harmonics for aircraft power supply systems)
PublicationПредставлены два алгоритма активной фильтрации для силового преобразователя с активным подавлением высших гармоник. Первый алгоритм основан на дискретном преобразовании Фурье: посредством синтезированной системы управления инвертированные измеренные высшие гармоники напряжения поступают на вход инвертора. Второй метод управления основан на алгоритме с использованием принципов самообучения, что значительно снижает потребность в...
-
LabVIEW-based intelligent system of protection against electric shock for photovoltaic installations
PublicationEvaluation of shock hazard in installations with photovoltaic sources of energy is more complicated than in a conventional low voltage system. In case of earth fault in photovoltaic generators, that are connected to the AC power public grid, a composite waveform of earth fault current in the installation may occur. For composite waveforms, the safety criteria should be modified. The paper considers the effect of the composite waveforms...
-
Interconnection of the Customer-Side Resources Using Single Phase VAPF
PublicationThe paper introduces method for utilization of the customer-side generated energy using single phase voltage active power filter. Structure and control method of the power electronics converter has been described and some simulation results are shown to prove usefulness of this arrangements. Proposed application realizes the following functions: power quality improvement, uninterruptible supplying and energy costs reduction.
-
Conducted EMI Propagation Paths in DC-AC Hard Switching Converter
PublicationIn order to limit the electromagnetic interference (EMI) in power electronics devices, knowledge about the phenomena connected with EMI generation and propagation is necessary. This papers describes the propagation paths in the 3 phase voltage source inverter using wide-band simulation and laboratory test with the signal processing method Wiener filtering, where the transfer functions between voltage across switches and the perturbation...
-
Analiza i badania transformatora hybrydowego z przekształtnikiem AC/DC/AC współdziałającym z przełącznikiem zaczepów
PublicationRozprawa dotyczy badań nad układem transformatora hybrydowego, który oprócz możliwości regulacji ciągłej napięcia za pomocą przekształtnika energoelektronicznego, posiada układ regulacji skokowej w postaci przełącznika zaczepów. Badane urządzenie przeznaczone jest do stabilizacji napięcia w dystrybucyjnej sieci niskiego napięcia. Dzięki skoordynowanej pracy układów (ciągłego i skokowego) uzyskana zostaje tzw. Wielostrefowa Regulacja...
-
BPL-PLC Voice Communication System for the Oil and Mining Industry
PublicationApplication of a high-efficiency voice communication systems based on broadband over power line-power line communication (BPL-PLC) technology in medium voltage networks, including hazardous areas (like the oil and mining industry), as a redundant mean of wired communication (apart from traditional fiber optics and electrical wires) can be beneficial. Due to the possibility of utilizing existing electrical infrastructure, it can...
-
REALIZACJA USŁUGI DSR NA PRZYKŁADZIE DOMÓW JEDNORODZINNYCH
PublicationW artykule przedstawiono ideę usługi DSR, czyli reakcji strony popytowej, dla odbiorców rozproszonych. Polega ona na zmniejszeniu zapotrzebowania na energię elektryczną lub przesunięcia go w czasie. Wdrożenie usługi może w znaczny sposób wpłynąć na pracę systemu elektroenergetycznego – usługa DSR może wspomóc bilansowanie systemu elektroenergetycznego, a także pozytywnie oddziaływać na jego elastyczność, wydajność oraz stabilność....
-
Porównanie działania transformatora symetryzującego (zygzak) z aktywnym energoelektronicznym symetryzatorem prądów fazowych linii niskiego napięcia
PublicationNa potrzeby planowania sieci niskiego napięcia operatorzy systemów dystrybucyjnych (OSD) zakładają symetryczne warunki obciążenia linii. Z roku na rok, rośnie liczba rozproszonych systemów fotowoltaicznych (PV) zainstalowanych w sieciach niskiego napięcia, których większość to małe jednofazowe systemy dachowe. Dodatkowo, do niesymetrii obciążenia przyczyniają się instalowane masowo pompy ciepła i ładowane jednofazowo samochody...
-
Current Source Inverter Fed Drive
PublicationThis book covers three-phase and multiphase (more than three-phase) motor drives including their control and practical problems faced in the field (e.g., adding LC filters in the output of a feeding converter), are considered. The new edition contains links to Matlab®/Simulink models and PowerPoint slides ideal for teaching and understanding the material contained within the book. Readers will also benefit from the inclusion of: A...
-
Failure analysis of a high-speed induction machine driven by a SiC-inverter and operating on a common shaft with a high-speed generator
PublicationDue to ongoing research work, a prototype test rig for testing high-speed motors/generators has been developed. Its design is quite unique as the two high- speed machines share a single shaft with no support bearings between them. A very high maximum operating speed, up to 80,000 rpm, was required. Because of the need to minimise vibration during operation at very high rotational speeds, rolling bearings were used. To eliminate...
-
Application of sliding switching functions in backstepping based speed observer of induction machine
PublicationThe paper presents an analysis of the speed observer which is based on the backstepping and sliding mode approach. The speed observer structure is based on the extended mathematical model of an induction machine. The observer structure is based on the measured phase stator currents and transformed to ( αβ ) coordinate system. The stator voltage vector components are treated as known values. Additionally, such an observer structure...
-
Design advantages and analysis of a novel five-phase doubly-fed induction generator
PublicationPurpose – The purpose of this paper is to provide an analysis of the performance of a new five-phase doubly fed induction generator (DFIG). Design/methodology/approach – This paper presents the results of a research work related to fivephase DFIG framing, including the development of an analytical model, FEM analysis as well as the results of laboratory tests of the prototype. The proposed behavioral level analytical model is based...
-
Szacowanie niepewności pomiarowej układu do diagnostyki łożysk opartej na analizie mocy chwilowej.
PublicationW artykule przedstawiono metodologię szacowania niepewności pomiarowej wykorzystanego do badań diagnostycznych łożysk silników indukcyjnych układu pomiarowego, składającego się z dzielnika napięcia oraz bocznika. Wyniki tych analiz pozwalają spre-cyzować, jakiej niepewności pomiarowej można się spodziewać, dokonując badań diagnostycznych łożysk silników indukcyjnych w określonych warunkach, na stanowisku badawczym metodą pomiaru...
-
Szacowanie niepewności pomiarowej układu do diagnostyki łożysk opartej na analizie mocy chwilowej
PublicationW artykule przedstawiono sposób szacowania niepewności układu pomiarowego, składającego się z dzielnika napięcia oraz bocznika, który wykorzystano do badań diagnostycznych łożysk silników indukcyjnych. Wyniki analizy metrologicznej pozwalają sprecyzować, jakiej niepewności pomiarowej można się spodziewać, dokonując badań diagnostycznych łożysk silników indukcyjnych w określonych warunkach, na stanowisku badawczym metodą...
-
Nonlinear Control of a Doubly Fed Generator Supplied by a Current Source Inverter
PublicationNowadays, wind turbines based on a doubly fed induction generator (DFIG) are a commonly used solution in the wind industry. The standard converter topology used in these systems is the voltage source inverter (VSI). The use of reverse-blocking insulated gate bipolar transistor (RB-IGBT) in the current source inverter topology (CSI), which is an alternative topology, opens new possibilities of control methods. This paper presents...
-
Feedback Control of Doubly-Fed Generator Connected to Current Source Converter
PublicationDoubly-fed induction generator (DFIG) system supplied by current source converter (CSC) is considered in this article. The DFIG can work in two independent modes: AC grid connection and stand-alone mode. The DFIG is connected to the ac grid directly through its stator and the CSC links the rotor side. In this mode, the active and reactive powers of the DFIG must be controlled. This article proposes two control system structures...
-
Programmable Input Mode Instrumentation Amplifier Using Multiple Output Current Conveyors
PublicationIn this paper a programmable input mode instrumentation amplifier (IA) utilising second generation, multiple output current conveyors and transmission gates is presented. Its main advantage is the ability to choose a voltage or current mode of inputs by setting the voltage of two configuration nodes. The presented IA is prepared as an integrated circuit block to be used alone or as a sub-block in a microcontroller or in a field...
-
Multi-pulse VSC arrangements with coupled reactors
PublicationThis paper presents a novel approach to the multipulse VSC (Voltage Source Converter) arrangements based on several conventional inverter modules connected in parallel by using coupled reactors. This solution reduces the THD of the output voltage, despite the low switching frequency of transistors. The advantage of the proposed solution is also a relatively small rated power of the reactors. Proposed new arrangements for different...
-
Wireless Charging Station Design for Electric Scooters: Case Study Analysis
PublicationThis study proposes an example of a wireless charging station design for a small-scale vehicle available on the market. The article analyzes basic transmitter inverter topologies and their compensation methods in terms of flexibility of control, tolerance to uncertainty in positioning, and the possibility of decreasing the integration price. Our comprehensive analysis focuses on the battery voltage range, energy capacity, cost,...
-
Computer System for Evaluation of Shock Hazard in Circuits with Non-sinusoidal Earth Currents
PublicationEffects of current on people are mainly considered for 50/60 Hz sinusoidal current and smooth direct current. However, modern low voltage circuits are very often equipped with power electronics converters – rectifiers, frequency converters, therefore non-sinusoidal earth currents (touch currents) occur. For non-sinusoidal currents safety criteria should be modified. This paper presents a computer system, based on LabVIEW environment,...
-
Hydrogen Production via Biomethane Reforming in DBD Reactor
PublicationProduction of hydrogen from CH4:CO2 (70%:30%) mixture simulating dry biogas in a DBD reactor supplied with AC of 1.0-2.0 kHz or nanosecond negative pulses is presented. We have found that hydrogen production and methane conversion degree increase linearly with discharge power in the range of up to 50 W. Nanosecond voltage pulses are much more efficient in hydrogen production than sine AC voltage
-
The concept of a new two-stage fuse for high power pulse forming
PublicationThis manuscript introduces the concept, physical operating principle and studies on a new and unique two stage forming fuse (TSFF) with interstage spark gap commutation and presents its application for forming high power pulses of extreme parameters. The paper classifies TSFF performance and compares it with conventional single-stage forming fuses. The conclusions are supported by analytical and experimental studies in laboratory...
-
Current harmonic controller in multiple reference frames for series active power filter integrated with 18-pulse diode rectifier
PublicationThe paper presents the control system and selected results of experimental tests of the AC/DC power converter consisting of an 18-pulse diode rectifier based on coupled reactors and a serial active power filter. Proportional integral controllers with decoupling components are implemented in multiple reference frames for selective line current harmonic suppression. The regulator is provided with a backtracking anti-windup mechanism...
-
The Methodology of identifying the place to install shunt compensators in the transmission network
PublicationThis methodology of selection and localization of static com- paper presents pensators in wide network. Proposed method is based on analysis of voltage area power profiles in the nodes of the power grid, and designating locations, In Which Voltages ex- cessively tend to change in time. Practical way of modeling the SVC device in PLANS program you Presented, as well as some example results of research.
-
Incomplete Cross-Bonding in the MV Line. Experience from the Operation of MV Single Cable Lines
PublicationCable lines are one of the basic components of power systems. Medium and high voltage cables mainly comprise a metallic sheath, which is concentric to the main core conductor. There are several operating schemes of such cable lines, which differ in the place of earthing of sheaths and the possible use of the sheaths and/or conductors crossing. The sheaths cross-bonding is typically done in two places of one cable line section,...
-
Unity-Gain Zero-Offset CMOS Buffer with Improved Feedforward Path
PublicationA voltage unity-gain zero-offset CMOS amplifier with reduced gain error and increased PSRR (power supply rejection ratio) is proposed. The amplifier uses two feed mechanisms, negative feedback and supporting positive feedforward, to achieve low deviation from unit gain over the entire input range. The circuit, designed in a standard 180-nanometer 1.8-voltage CMOS process, is compared with two known buffers of similar topology,...
-
Polyarmonic model of synchronous generator for analysis of autonomous power generation systems
PublicationAbstract: This paper presents the polyharmonic modelling of synchronous generator (SG) in machine variables. The simple geometry and windings physical layout has been used for inductance calculations of a salient-pole SG. The main advantage of this model is the ease of describing an autonomous power generation system (APGS) in terms of its topology and thus providing effective analysis at the static and dynamic states, both for...
-
Speed sensorless ac drive with inverter output filter and fault detection using load torque signal
PublicationIn this paper, a sensorless induction motor (IM) drive using speed observer system is presented. The system includes load torque computation for gear fault detection. Nonlinear control method is adopted for controlling the motor over a wide speed range. An LC filter for smoothing current and voltage waveforms is used at the output of the voltage inverter. The use of filter imposes more building of the used observer to avoid using...
-
SiC-Based Power Electronic Traction Transformer (PETT) for 3 kV DC Rail Traction
PublicationThe design of rolling stock plays a key role in the attractiveness of the rail transport. Train design must strictly meet the requirements of rail operators to ensure high quality and cost-eective services. Semiconductor power devices made from silicon carbide (SiC) have reached a level of technology enabling their widespread use in traction power converters. SiC transistors oering energy savings, quieter operation, improved reliability...
-
Buck-Boost Inverters with Symmetrical Passive Four-terminal Networks
PublicationAlternating Voltage Inverters (Converters) supplied by low-voltage sources DC (ex. fuel cell, photovoltaic cell) are most frequently realized on the basis of the three fundamental topologies: a) PWM voltage inverter with boost-converter" system, b) PWM voltage inverter with transformed converter DC/DC in the ,,boost-converter" system, c) PWM current converter. However none of these solutions is claimed to be the best and dominant...
-
Medium-Voltage Drives: Challenges and existing technology
PublicationThe article presents an overview of state-of-art solutions, advances, and design and research trends in medium-voltage (MV) drive technologies - and also discusses the challenges and requirements associated with the use of such drives. The choice and deployment of MV drives in industries are associated with numerous requirements related to the front-end converter (grid side) and inverter (machine side). The focus is on solutions...
-
Secondary arc modelling for single pole reclosing analyses
PublicationThe paper discusses two evaluation methods of single pole auto-reclosing process effectiveness in HV transmission lines. Secondary arc current and recovery voltage calculation results obtained by load flow calculation are compared to the results obtained by the time domain simulations. Moreover, a nonlinear secondary arc model implementation is presented. The paper presents the study results for the three types of EHV transmission...