displaying 1000 best results Help
Search results for: LOW-NOISE PAVEMENT
-
Elimination of impulsive disturbances from archive audio files – comparison of three noise pulse detection schemes
PublicationThe problem of elimination of impulsive disturbances (such as clicks, pops, ticks, crackles, and record scratches) from archive audio recordings is considered and solved using autoregressive modeling. Three classical noise pulse detection schemes are examined and compared: the approach based on open-loop multi-step-ahead signal prediction, the approach based on decision-feedback signal prediction, and the double threshold approach,...
-
Investigating impacts of asphalt mixture properties on pavement performance using LTPP data through random forests
Publication -
Digital techniques for noise reduction in CCD detectors
Publication -
Detection of measurement noise in surface topography analysis
Publication -
Analysis of electrochemical noise by means of bispectral technique
Publication -
Pitting corrosion in steel and electrochemical noise intensity
Publication -
Joint time–frequency analysis of electrochemical noise
Publication -
New methods of underwater ship noise classification
PublicationDetekcja, klasyfikacj, identyfikacja i rozpoznanie cech hałasu generowanego przez statki jest bardzo istotna z punku widzenia naukowego i obronnego. Włożono wiele wysiłku w rozwój technologii sonarów pasywnych, która umożliwia zastosowanie hałasów podwodnych do celów praktycznych. Przedstawiono wyniki badań, które ukazują możliwości wykorzystania sieci neuronowej do klasyfikacji źródeł generowanych przez układy mechaniczne, odpowiadających...
-
Tire/road noise - generation, measurement, and abatement
PublicationPodano określenia i definicje dotyczące hałasu opon samochodowych. Omówiono mechanizmy generowania tego hałasu oraz zasady modelowania. Przedstawiono metody pomiaru hałasu opon oraz stosowane systemy pomiarowe. Podano normy dotyczące hałasu opon. Omówiono wpływ opony i nawierzchni na hałas generowany przez toczące się koło ogumione. Zaprezentowano koła kompozytowe oraz opony z bieżnikiem poroelastycznym generujące niski poziom...
-
Novel applications of noise measurements in technology and sensing.
PublicationPomiary szumów są źródłem informacji oraz rodzajem badań nieniszczących dotyczących jakości elementów elektronicznych oraz innych materiałów. Mogą one poprawić selektywność i czułość wykrywania gazów oraz pozwalają monitorować zjawiska korozji. W tym celu wyznacza się właściwości statystyczne fluktuacji prądu lub napięcia w zakresie małych częstotliwości. W artykule przedstawiono i przedyskutowano wybrane, ze względu na ich znaczenie...
-
A method of identification of RTS components in noise signals
PublicationW artykule przedstawiono oryginalną metodę wydzielania szumu RTS (Random Telegraph Signal) - dwupoziomowego lub wielopoziomowego - z sygnału szumowego. Podstawą oceny jakości metody jest założenie, że wartości chwilowe szumu RTS mają rozkład niegaussowski natomiast pozostała część sygnału ma rozkład gaussowski.Algorytm identyfikacji wielopoziomowych szumów RTS w sygnałach szumowych małej częstotliwości oparty został na aproksymacji...
-
Web Based Acoustic Noise Measurement System.
PublicationW referacie przedstawiono projekt multimedialnego systemu przeznaczonego do monitorowania zagrożeń hałasem środowiskowym. Nadrzędnym celem realizowanego projektu jest zwiększenie efektywności profilaktyki chorób słuchu. Opracowywany system umożliwia odbiór, przechowywanie danych, analizę i wizualizację wyników pomiarów hałasu pozyskanych od urządzeń pomiarowych za pośrednictwem Internetu. Przedstawiono również opracowanie miernika...
-
Application of electrochemical noise technique in corrosion monitoring
PublicationTechnika szumu elektrochemicznego od ponad 20 lat stanowi przedmiot intensywnych badań mających na celu jej praktyczne zastosowanie w monitorowaniu korozji. U podstaw omawianej metody leży odpowiednia analiza rejestrowanych symultanicznie przebiegów prądowych i potencjałowych. W zależności od użytej techniki obróbki danych uzyskane mogą być informacje dotyczące ilościowych (szybkość) i jakościowych (rodzaj zaatakowania) cech procesu...
-
Uncertainty in measuring noise parameters of a communication receiver
PublicationPrzedstawiono sposób pomiarów mocy dźwięku generowanego przez silnik sytemu napędowego z przemiennikiem częstotliwości. Wyprowadzono wyrażenie na niepewność wyznaczania mocy dźwięku emitowanego przez silnik, przy użyciu pomiarów poziomu dźwięku. Niepewność wyników pomiarów była szacowana w oparciu o metodę typu B. Przedstawiono wyniki badań laboratoryjnych i analizy wybranych składników niepewności dla układu napędowego z silnikiem...
-
Pitting corrosion in steel and electrochemical noise intensity
PublicationPrzedstawiono analizę szumu elektrochemicznego, rejestrowanego w obecności korozji wżerowej. Stwierdzono korelację pomiędzy intensywnością szumu a ubytkiem mas elektrod stalowych. Rejestry szumowe rozłożone zostały na składowe częstotliwościowe za pomocą przekształcenia falkowego. Dla pewnych składowych stwierdzono silniejszą korelację z ubytkiem mas korodujących elektrod. Pasmo częstotliwościowe powyższych składowych odpowiada...
-
Barkhausen Noise Calculation by Hysteresis Model Parameters
PublicationPętla histerezy natężenia efektu Barkhausena wyliczono wykorzystując model histerezowy. Założono, iż straty energii na efekt Barkhausena zależą od szybkości granicy domenowej oraz od częstości występowania skoków Barkhausena. Pokazano wyliczenia wykonane dla stali Fe-Si (ziarna zorientowane w kierunku [100] względem kierunku walcowania)
-
Nonlinearity of electrochemical noise caused by pitting corrosion
PublicationPomiary wielkości statystycznych, innych niż rozkład widmowy czy amplitudowy mogą być źródłem dodatkowych informacji na temat mechanizmu powstawania szumu elektrochemicznego. Bispektrum stosowane jest do wykrycia istnienia składowych nieliniowych w badanym rejestrze szumowym. Analizowano elektrochemiczny szum prądowy rejestrowany w warunkach korozji wżerowej. Zaobserwowano zależność prąd-czas charakterystyczną dla stanu tworzenia...
-
Optimization of active circuits for substrate noise suppression
PublicationZakłócenia generowane przez szybkie podukłady cyfrowe w mieszanych systemach analogowo-cyfrowych realizowanych na wspólnym podłożu stają się dużym problemem. W pracy zaproponowano metodę optymalizacji aktywnych układów tłumienia zakłóceń. Zilustrowano skuteczność działania metody na wybranym układzie i uzyskano ponad 9 dB poprawę tłumienia zakłóceń na częstotliwości 1GHz w porównaniu do znanych rozwiązań.
-
A novel dynamic noise maps visualization tool
PublicationW referacie przedstawiono aplikację realizujacą wizualizację dynamicznych map akustycznych zintegrowaną z multimedialnym systemem monitoringu hałasu. Moduł ten został oparty na nowym podejściu do wykreślania dynamicznych map, w referacie przedstawiono porównanie wyników uzyskanych metodami tradycyjnymi i zaproponowaną metodą. Słowa kluczowe: dynamiczne mapy, wizualizacja, monitoring, hałas, system GIS
-
Noise as a Factor of Green Areas Soundscape Creation
Publication -
Analysis of electrochemical noise by means bispectral techniques
PublicationProcesy o charakterze nieliniowym są często spotykane w praktyce pomiarów elektrochemicznych oraz korozyjnych. Przykładem mogą być procesy elektrodowe kontrolowane aktywacyjnie, dla których często stosowanym podejściem jest linearyzacja. W niniejszym, wprowadzającym doniesieniu przedstawione zostały możliwości analizy nieliniowości szumu elektrochemicznego z wykorzystaniem widm wyższych rzędów. W pracy przedstawiono wyniki analizy...
-
Measurements of the mechanical Barkhausen noise in ferromagnetic steels
PublicationArtykuł ten przedstawia wpływ zmian w mikrostrukturze stali P91, powstałych w skutek obróbki cieplnej, na właściwości mechanicznego efektu Barkhausena (MeBN). Parametry takie jak amplituda obwiedni napięcia skutecznego (RMS) MeBN oraz położenie maksimum tejże obwiedni porównywane są, pod kątem czułości na obróbkę cieplną materiału, z klasycznymi parametrami takimi jak pole koercji magnetycznej czy też twardość mechaniczna HV. Największą...
-
High-performance analog circuits : bipolar noise
PublicationOmówiono typowe źródła szumów występujące w tranzystorach bipolarnych, a mianowicie: cieplne, śrutowe, generacyjno-rekombinacyjne, 1/f, 1/f2, wybuchowe (RTS),lawinowe. Przedstawiono szumowy schemat zastępczy tranzystora bipolarnego oraz opisano wydajności poszczególnych źródeł szumów. Przytoczono informacje o zastępczej rezystancji tranzystora szumów oraz współczynniku szumów.
-
Low frequency nois of supecapacitor
Open Research DataDataset contains results of low frequency noise observation during discharge of commercially available supercapacitor, type DRL 2.7V 10F, with a nominal capacitance 10 F and a nominal voltage 2.7 V. Supercapacitor was charged to various voltages and discharged through a resistor. In the experiment the 50 Ohm and 200 Ohm resistors were used. The supercapacitor...
-
Low Power Baseband Processor for M2M Reconfigurable Radio Test Platform
PublicationSoftware Defined Radio (SDR) is becoming more andmore frequently used technique for wireless communication. Itfacilitates as fast prototyping and is a versatile method fordeveloping new communication systems. SDR can be realizedbased on high computational capacity platform, where powerconsumption is no a primary concern like i.e. DVB or BTStransmitters. Another trend are low power systems, whereavailable power in reduced and more...
-
PHYSICA E-LOW-DIMENSIONAL SYSTEMS & NANOSTRUCTURES
Journals -
Fuel cell noise data
Open Research DataMeasurement data of Hydrogen PEM fuel cels. The voltage fluctuations were measured over single cels of stack of 10 cels.
-
On the use of a charge balancing method for low energy measurements
PublicationThe paper presents the method for the estimation of the energy consumption of the low-power microcontroller-based devices. Due to high dynamics of the changes of the supply current of the tested devices during the operational cycle, the consumed energy estimation is not easy. In order to avoid disadvantages of known methods, the charge balancing method was employed similarly like in some types of A/D converters.
-
SIMPLY AND LOW COAST ELECTROMYOGRAPHY SIGNAL AMPLIFIER
PublicationRecently, there has been a noticeable increase in interest in solu tions utilizing electrical signals accompanying muscle activity. Electromyography (EMG) is a technique for recording, analysis and evaluating the electrical activity produced by striated muscle. Its great popularity is due, among other, to the ability to measure with non-invasive electrodes (calle d as sEMG surface electromyography)....
-
Low Frequency Conducted Emissions of Grid Connected Static Converters
PublicationPulse-width modulated rectifiers are nowadays commonly used for AC to DC power conversion. PWM rectification technology is very effective and allows for bidirectional power flow with the possibility of power factor improvement and low-order harmonic emission limitation. Unfortunately, employed PWM boost topology results with generation of input current harmonic distortions in a frequency range tightly correlated to modulation frequency....
-
Simple and low-cost wireless voting system
PublicationThis paper presents the concept of a simple and low-cost wireless voting system working on the 868 MHz frequency band. Described system is dedicated to general shareholders assemblies but it can be easily adapted for other applications. The main advantage is its simplicity and mobility as it consists solely of three components - voting modules, base station and a PC application from which the whole system is managed. This architecture...
-
Simple and low-cost wireless voting system
PublicationThis paper presents the concept of a simple and low-cost wireless voting system working in the 868 MHz frequency band. The described system is dedicated to general shareholders assemblies but it can be easily adapted for other applications. The main advantage is its simplicity and mobility as it consists solely of three components - voting modules, a base station and a PC application from which the whole system is mamaged. This...
-
Low-coherence sensors with nanolayers for biomedical sensing
PublicationIn this paper, we describe the fiber optic low-coherence sensors using thin film. We investigated their metrological parameters. Presented sensors were made with the use of standard telecommunication single mode optical fiber (SMF28). Different materials were applied to obtain thick layers, such as boron doped diamond, silver and gold. The thickness of layers used in the experiments ranged from 100 nm to 300 nm. Measurements were...
-
Janusz Smulko prof. dr hab. inż.
PeopleHe was born on April 25, 1964 in Kolno. He graduated in 1989 with honors from the Faculty of Electronics at Gdańsk University of Technology, specialising in measuring instruments. In 1989 he took second place in the Red Rose competition for the best student in the Pomerania Region. Since the beginning of his career ha has been associated with Gdańsk University of Technology: research assistant (1989-1996), Assistant Professor (1996-2012),...
-
Noise Mapping
Journals -
Low cost microwave X-band generator
PublicationA low cost microwave X-band generator for educational purposes was designed and built. Its simple construction and user's interface makes it suitable for a student laboratory.The generator is based on a single frequency conversion concept. It uses a digitally tunable PLL chip for intermediate frequency generation and an active frequency multiplier for frequency conversion. The generator covers 9,7 - 11 GHz part of the X frequency...
-
Endometrial stromal sarcoma, low grade - Female, 52 - Tissue image [6120730031835891]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 52 - Tissue image [6120730031832721]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 52 - Tissue image [6120730031839801]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 52 - Tissue image [6120730031837111]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 52 - Tissue image [6120730031835991]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 52 - Tissue image [6120730031834931]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 52 - Tissue image [6120730031835811]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 52 - Tissue image [612073003183841]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 52 - Tissue image [6120730031834521]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 52 - Tissue image [6120730031832401]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 52 - Tissue image [612073003183971]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
On the low-cost design of abbreviated multisection planar matching transformer
PublicationA numerically demanding wideband matching transformer composed of three nonuniform transmission lines (NUTLs) has been designed and optimized at a low computational cost. The computational feasibility of the design has been acquired through the exploitation of low-fidelity NUTL models in most steps of the design procedure and an implicit space mapping optimization engine, providing high accuracy results with only a handful of EM...
-
Enhanced method of DS-CDMA low level singnals detection
PublicationThe following article comprises three main parts. The first one generally describes two methods of low level signals detection which are in the interest of this study. The signal spectrum averaging technique is shown as well as the method exploiting averaged spectrum of the signal raised to the power of 2n (nN). Additionally, this section briefly presents proposed enhancements and modifications of these two solutions, which allow...
-
A low-voltage CMOS negative impedance converter for analogue filtering applications
PublicationLow-voltage high-frequency continuous-time filters are still required in many applications and are the subject of continuing research. There are many techniques to realize integrated filters, including OTA C, Opamp RC and MOSFET-C-Opamp. The latter two show high dynamic range at low supply voltage, but their frequency operating range is usually limited to several megahertz. Transconductance filters are dedicated to higher frequencies....