Filters
total: 5211
-
Catalog
- Publications 4096 available results
- Journals 21 available results
- Conferences 2 available results
- Publishing Houses 1 available results
- People 37 available results
- Projects 1 available results
- Research Equipment 1 available results
- e-Learning Courses 15 available results
- Events 1 available results
- Open Research Data 1036 available results
displaying 1000 best results Help
Search results for: LOW-FREQUENCY FILTERS
-
Endometrioid stromal sarcoma, low grade - Female, 74 - Tissue image [6180730013782931]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Endometrioid stromal sarcoma, low grade - Female, 74 - Tissue image [6180730013783131]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Waves in a short cable at low frequencies, or just hand-waving? What does physics say? (Invited paper)
PublicationWe address the question of low-frequency signals in a short cable, which are often considered as waves in engineering calculations. Such an assumption violates several laws of physics, but exact calculations can be carried out via linear network theory.
-
Mucinous cystic neoplasm with low grade dysplasia - Female, 40 - Tissue image [630073002825231]
Open Research DataThis is the histopathological image of PANCREAS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mucinous cystic neoplasm with low grade dysplasia - Female, 40 - Tissue image [7040247104932011]
Open Research DataThis is the histopathological image of PANCREAS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mucinous cystic neoplasm with low grade dysplasia - Female, 40 - Tissue image [6300730028253261]
Open Research DataThis is the histopathological image of PANCREAS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
On low-fidelity models for variable-fidelity simulation-driven design optimization of compact wideband antennas
PublicationThe paper addresses simulation-driven design optimization of compact antennas involving variable-fidelity electromagnetic (EM) simulation models. Comprehensive investigations are carried out concerning selection of the coarse model discretization density. The effects of the low-fidelity model setup on the reliability and computational complexity of the optimization process are determined using a benchmark set of three ultra-wideband...
-
Multiple-channel frequency-adaptive active vibration control using SONIC
PublicationSONIC (self-optimizing narrowband interference canceller) is an acronym of a new approach to rejection of sinusoidal disturbances acting at the output of a discretetime stable linear plant with unknown and possibly timevarying dynamics. The paper presents two frequency-adaptive extensions of the multivariate SONIC algorithm. The efficacy of the proposed solutions is tested using our laboratory-scale active vibration control plant.
-
Continuous wave sonar with hyperbolic frequency modulation keyed by pseudo-random sequence
PublicationA CW FM type sounding signal is used in the classical solution of silent sonar. While the signal provides a relatively simple implementation of digital signal processing, and ensures good detection conditions, unfortunately, in the presence of the Doppler effect, distance measurement results tend to be wrong. This is due to the fact that the received signal’s instantaneous frequency value is dependent both on the distance to the...
-
SONIC - Self-optimizing narrowband interference canceler: comparison of two frequency tracking strategies
PublicationThis paper presents a new approach to rejection of complex-valued sinusoidal disturbances acting at the output of a discrete-time linear stable plant with unknown and possibly time-varying dynamics. It is assumed that both the instantaneous frequency of the sinusoidal disturbance and its amplitude may be slowly varying with time and that the output signal is contaminated with wideband measurement noise. The proposed disturbance...
-
On the deformation and frequency analyses of SARS-CoV-2 at nanoscale
PublicationThe SARS-CoV-2 virus, which has emerged as a Covid-19 pandemic, has had the most significant impact on people's health, economy, and lifestyle around the world today. In the present study, the SARS-CoV-2 virus is mechanically simulated to obtain its deformation and natural frequencies. The virus under analysis is modeled on a viscoelastic spherical structure. The theory of shell structures in mechanics is used to derive the governing...
-
Substrate Integrated Waveguide-Based Frequency-Tunable Self-Octaplexing Antenna
PublicationThis communication presents the first-ever substrate integrated waveguide (SIW)-based frequency-tunable self-octaplexing antenna (SOA) for wireless communication. The structure is arranged by implementing eight distinct patches with planar 50-ohm feedlines at the top of the SIW cavity, which realize eight distinct resonant frequencies. Independent tuning of each resonant frequency is achieved by incorporating appropriately allocated...
-
Power flow in typical series-parallel hybrid filters topologies
Publication -
Development of HFB with the Use of 2nd Order Pass-Band Filters
Publication -
Structure generation and performance comparison of elliptic Gm-C filters.
PublicationW oparciu o zestaw macierzy opisujący ogólną topologię filtrów typu Gm-C opracowano procedurę efektywnej generacji struktur filtrów dolnoprzepustowych. Dla filtrów tego typu podano wyrażenia pozwalające analizować właściwości wrażliwościowe oraz określono zestaw odpowiednich kryteriów porównawczych. Szczegółowe badania porównawcze przeprowadzono dla wybranych filtrów 3-go rzędu w tym realizowanych w strukturach LF(leapfrog) i...
-
Design of waveguide filters using multiple irises and folded elements.
PublicationW pracy został zaprezentowany przegląd metod projektowania filtrów falowodowych w kontekście zarówno klasycznych metod syntezy jak i współczesnych algorytmów. W szczególności rozważonoanalizę filtrów z wieloaperturowymi przegrodami oraz filtrówzbudowanych w wygiętych odcinkach falowodów. Zaprezentowano przykłady w pełni wykorzystujące zalety wygiętych falowodów a także pokazano wydajne metody optymalizacji oparte na badaniu położeń...
-
Nonlinear distortion analysis and optimisation of general OTA-C filters.
PublicationW pracy przedstawiono opis analityczny ogólnej struktury filtrów OTA-C zawierających nieliniowe elementy aktywne. Wprowadzono nieliniowy układ równań różniczkowych zwyczajnych opisujący dynamikę tej klasy układów aktywnych. Opis ten pozwala, przy użyciu standardowych metod numerycznych, na przeprowadzenie efektywnej analizy czasowej filtrów OTA-C. Proponowane podejście może być stosowane do badania dowolnych efektów nieliniowych...
-
Canonic structures of odd-order elliptic Gm-C filters.
PublicationW pracy zaproponowano nowe rozwiązania układowe struktur kanonicznych eliptycznych filtrów Gm-C czasu ciągłego, rzedu nieparzystego. Opracowane struktury charakteryzują się małą liczbą elementów pasywnych oraz aktywnych i są przewidziane do zastosowań w filtrach niskomocowych o małej wrażliwości. W przeprowadzonych badaniach porównywano wybrane struktury 3-go rzędu pod względem właściwości i wymagań układów scalonych, w których...
-
Analysis and Optimization of Noise in Continuous-Time OTA-C Filters
PublicationW pracy przedstawiono ogólną procedurę analizy szumów w filtrach klasy OTA-C czasu ciągłego. Procedura umożliwia analizę filtrów o dowolnej topologii i dowolnego rzędu w ramach rozważanej klasy. W oparciu o opis macierzowy ogólnej struktury filtru OTA-C wyprowadzono ogólne formuły pozwalające na wyznaczanie i optymalizację szumów dowolnego filtru OTA-C. Przedstawione wyniki są użyteczne nie tylko dla klasycznych (dyskretnych lub...
-
Eigenvalue approach to synthesis of prototype filters with source/load coupling
PublicationArtykuł przedstawia nową, szybko zbieżną, technikę syntezy macierzy sprzężeń filtrów o charaktrystyce Czebyszewa. Synteza opiera się na zastosowaniu metody najmniejszych kwadratów w odniesieniu do wartości własnych macierzy sprzężeń oraz jej podmacierzy.
-
Noise Analysis and Optimization of Continuous-Time OTA-C Filters
PublicationW pracy przedstawiono efektywną procedurę wyznaczania szumów w filtrach OTA C czasu ciagłego. Procedura wyprowadzona jest w oparciu o ogólny model filtru OTA C oraz jego opis macierzowy. Podano jawne formuły pozwalające okreslić odniesione do wejścia widmo szumów dowolnego filtru rozważanej klasy. Otrzymane wyniki teoretyczne zostały zweryfikowane poprzez porównanie z wynikami otrzymywanymi za pomocą symulatora SPICE dla wybranych...
-
Efficient tolerance analysis of continuous-time Gm-C filters
PublicationW pracy przedstawiono efektywną metodą analizy tolerancji dowolnych filtrów Gm-C. Przedstawiono ogólny model filtrów Gm-C oraz jego opis algebraiczny. Używając tego podejścia, wyprowadzono formuły pozwalające na wyznaczenie odchyłek funkcji przenoszenia filtru spowodowanych odchyłkami wartości elementów filtru od wartości nominalnych. Proponowana metoda charakteryzuje się niewielką złożonością obliczeniową, co pozwala na jej wykorzystanie...
-
New approach to computer aided design of coupled resonator filters
PublicationW niniejszej pracy zastosowane zostały gradientowa metoda optymalizacji oraz nowa definicja funkcji celu do projektowania filtrów mikrofalowych. Definicja funkcji celu została oparta na badaniu położenia zer i biegunów funkcji przenoszenia optymazlizownanych układów.
-
Canonic structures of old order elliptic Gm-C filters.
PublicationW pracy zaproponowano nowe struktury kanoniczne eliptycznych filtrów Gm-Crzędów nieparzystych. Opracowane układy filtrów wymagają małej liczby elementów zarówno aktywnych jak i pasywnych niezbędnych do realizacji żądanych charakterystyk częstotliwościowych.W pracy są również zaprezentowane rezultaty porównań właściwości przedstawionych struktur z przykładami realizacji układowych innych filtrów Gm-C.
-
Algebraic model of continuous time Gm-LC filters and applications.
PublicationW pracy zaprezentowano model algebraiczny filtrów Gm-LC czasu ciągłego i jego wybrane zastosowania. Zaproponowany model obejmuje struktury pracujące zarówno w trybie napięciowym jak i prądowym. Użyteczność opracowanego modelu potwierdzono na przykładzie syntezy eliptycznego filtru Gm-LC rzędu nieparzystego.
-
Gradient-based optimization of filters using FD-TD software
PublicationW artykule opisane jest nowe podejście do zagadnienia optymalizacji filtrów mikrofalowych pasmowo-przepustowych. Optymalizacja prowadzona jest z wykorzystaniem metody gradientowej poszukiwania minimum wartości funkcji celu oraz przy założeniu pełnofalowej symulacji obwodów metodą różnic skończonych w dziedzinie czasu. W artykule pokazane jest, że stosując zaawansowane techniki cyfrowego przetwarzania sygnałów możliwa jest optymalizacja...
-
Compensation of Dead Time Effects for Shunt Active Power Filters
PublicationThe paper presents a comprehensive approach to the compensation of the grid current distortion for shunt active power filter systems. Four different sources of current distortion are addressed: imperfect grid synchronization caused by the distortion in the grid voltages, time delays in the estimation of compensating currents and grid voltages, fluctuations of the dc bus voltage, and the distortion of inverter output voltages due...
-
Surgical tool tracking by on-line selection of structural correlation filters
PublicationIn visual tracking of surgical instruments, correlation filtering finds the best candidate with maximal correlation peak. However, most trackers only consider capturing target appearance but not target structure. In this paper we propose surgical instrument tracking approach that integrates prior knowledge related to rotation of both shaft and tool tips. To this end, we employ rigid parts mixtures model of an instrument. The rigidly...
-
Voltage Conditions in Low Voltage Grid with Connected Mictogeneration
PublicationThe introduction of distributed generation into a low voltage grid may cause voltage problems in it. The paper discusses the effect of microgeneration on voltage levels in a low voltage grid. A real low voltage grid of considerable length was selected for the analysis. The grid primarily supplies residential buildings in a rural area. Results of tests that consider potential measures which could be applied in this grid to improve...
-
Recent advances in high-frequency modeling by means of domain confinement and nested kriging
PublicationDevelopment of modern high-frequency components and circuits is heavily based on full-wave electromagnetic (EM) simulation tools. Some phenomena, although important from the point of view of the system performance, e.g., EM cross-coupling effects, feed radiation in antenna arrays, substrate anisotropy, cannot be adequately accounted for using simpler means such as equivalent network representations. Consequently, the involvement...
-
Analysis of inductive power transfer systems for variable air gap and voltage supply frequency
PublicationThe paper describes an IPT system, by which electrical energy may be transmitted through a large air gap between coils without electrical connection. It presents theoretical and simulation analysis of IPT, which allows for supplying a receiver in the conditions of slow, in relation to the dynamics of power supply, changes in dimension of the air gap. The influence of frequency characteristics of the system on the possible selection...
-
Recent Advances in Performance-Driven Surrogate Modeling of High-Frequency Structures
PublicationDesign of high‐frequency structures, including microwave and antenna components, heavily relies on full‐wave electromagnetic (EM) simulation models. Their reliability comes at a price of a considerable computational cost. This may lead to practical issues whenever numerous EM analyses are to be executed, e.g., in the case of parametric optimization. The difficulties entailed by massive simulations may be mitigated by the use of...
-
A new approach to active noise and vibration control - [Part II: unknown frequency case]
PublicationThis paper presents a new approach to rejection of complex-valued sinusoidal disturbances acting at the output of a discrete-time stable linear plant with unknown and possibly timevarying dynamics. It is assumed that both the instantaneous frequency of the sinusoidal disturbance and its amplitude may be slowly varying with time and that the output signal is contaminated with wideband measurement noise. It is not assumed that a...
-
Resonance Frequency Calculation of Spherical Microstrip Structure Using Hybrid Technique
PublicationIn this paper the spherical microstrip structure is considered. The structure is composed of a metallic patch with an arbitrary shape placed on a dielectric coated metallic sphere. In the analysis the hybrid technique is utilized. In this approach the finite-difference technique is applied in a cavity model to determine the current basis functions on the patch. Next, using method of moments, the resonance frequency of the structure...
-
Modeling by finite element methods of impact of erosion on frequency of normal modes of L-0 blade
PublicationAfter some time of exploitation steam turbine rotors blades in energetic industry they are being eroded and also their frequency of normal modes is changed. Those changes can cause to unwanted shift of blades normal mode frequencies. It is necessary to find quick method of rating changes of frequency in connection of mass loss due erosion. The evaluation of this dependence was made by finite element modeling method using HyperWorks...
-
The use of low-coherence interferometer for sugar content determination
PublicationIn this article, the implementation of low-coherence interferometer with signal processing in time domain for sugar content determination in aqueous solution is presented. The elaborated measurement set-up was tested with the use of synthesized source made of two low-coherence sources. The use of two sources with dedicated parameters enabled to obtain a proper metrological parameters of the measurement system. The elaborated low-coherence...
-
THE PROBLEM OF THE CALCULATION OF THE FREQUENCY OF DIAGNOSTIC EXAMINATIONS BASED ON DEVICE’S PROPER OPERATION TIME
PublicationThe paper presents the proposal to apply the normal distribution to solve the problem of the frequency of diagnostic tests. Particular emphasis is placed on simplicity of the method. This method may be useful for the average user technical system. The method reduces the number of assumptions to a minimum. The results do not raise of serious doubts but they require verification of course.
-
Jarosław Guziński prof. dr hab. inż.
PeopleJaroslaw Guzinski received M.Sc., Ph.D. and D.Sc. degrees from the Electrical Engineering Department at Technical University of Gdansk, Poland in 1994, 2000 and 2011 respectively. Since 2016 he is Associate Professor at Gdansk University of Technology. Currently he is the head of the Department of Electric Drives and Energy Conversion. From 2006 to 2009 he was involved in European Commission Project PREMAID Marie Curie, ‘Predictive...
-
Evaluation of Low Temperature Properties of Rubberized Asphalt Mixtures
PublicationThe paper presents low-temperature test results of asphalt mixtures designed with use of bitumen modified by crumb rubber and also SBS polymer. Laboratory tests were conducted on two types of asphalt mixtures for wearing course – stone matrix asphalt (SMA 8) and porous asphalt (PA 8). This paper presents results of the following laboratory tests at low temperatures: TSRST test, three point bending creep test, fracture toughness...
-
Pitch estimation of narrowband-filtered speech signal using instantaneous complex frequency
PublicationIn this paper we propose a novel method of pitch estimation, based on instantaneous complex frequency (ICF). New iterative algorithm for analysis of ICF of speech signal in presented. Obtained results are compared with commonly used methods to prove its accuracy and connection between ICF and pitch, particularly for narrowband-filtered speech signal.
-
Pitch estimation of narrowband-filtered speech signal using instantaneous complex frequency
PublicationIn this paper we propose a novel method of pitch estimation, based on instantaneous complex frequency (ICF). New iterative algorithm for analysis of ICF of speech signal in presented. Obtained results are compared with commonly used methods to prove its accuracy and connection between ICF and pitch, particularly for narrowband-filtered speech signal.
-
Low grade serous carcinoma - Female, 58 - Tissue image [10010729534339021]
Open Research DataThis is the histopathological image of OVARY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Low grade serous carcinoma - Female, 58 - Tissue image [10010729534326341]
Open Research DataThis is the histopathological image of OVARY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
A spline-based FE approach to modelling of high frequency dynamics of 1-D structures
PublicationIn this paper a computational methodology leading to the development of a new class of FEs, based on the application of continuous and smooth approximation polynomials, being splines, has been presented. Application of the splines as appropriately defined piecewise elemental shape functions led the authors to the formulation of a new approach for FEM, named as spFEM, where contrary to the well-known NURBS approach, the boundaries...
-
Estimation of time-frequency complex phase-based speech attributes using narrow band filter banks
PublicationIn this paper, we present nonlinear estimators of nonstationary and multicomponent signal attributes (parameters, properties) which are instantaneous frequency, spectral (or group) delay, and chirp-rate (also known as instantaneous frequency slope). We estimate all of these distributions in the time-frequency domain using both finite and infinite impulse response (FIR and IIR) narrow band filers for speech analysis. Then, we present...
-
A concept of software extension of 3D low-PRF radar systems to 4D semi-medium-PRF radar systems
PublicationWe present a concept of software modification of three-dimensional (3D) radar systems, designed to work in the low pulse repetition frequency mode, that equips them with the ability to estimate the radial velocity and to properly measure the range of targets that are detected outside the radar’s instrumented range. Despite the fact that the proposed modifications are designed so as to require only minor changes in software, they...
-
Multilocular cystic renal neoplasm of low malignant potential - Male, 42 - Tissue image [617073002674451]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Multilocular cystic renal neoplasm of low malignant potential - Male, 42 - Tissue image [6170730026749991]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Multilocular cystic renal neoplasm of low malignant potential - Male, 42 - Tissue image [6170730026745981]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Multilocular cystic renal neoplasm of low malignant potential - Male, 42 - Tissue image [6170730026743851]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.