Search results for: AC-DC POWER CONVERTERS
-
Testing HIADAC high impedance analyzer in Trento University laboratory on Baunier's RC model using 2 wire probe
Open Research DataThe dataset presents impedance spectrum of Baunier's RC model. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (1 mHz – 100 kHz) was selected in order to test the whole measureement range of the analyzer. In...
-
Hysteresis modelling of a medium frequency single-phase transformer
PublicationThe article describes a feedback Preisach hysteresis model equivalent circuit implementation of a medium frequency single-phase transformer being a part of a high power and high efficiency DC-DC converter. The macroscopic models of magnetic hysteresis are introduced and the feedback Preisach model is selected for further analysis. The hysteresis model is developed for a prototype transformer and the hysteresis loops are compared...
-
The voltage on bus bars of the main switchboard of the car carrier electrical power system at sea trials during a bow thruster start-up
Open Research DataThe dataset is a part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. In ships' electrical power systems, disturbances occurring in voltage waveforms on bus bars of the main switchboard are connected mainly with the processes...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on Baunier's RC model using 3 wire probe
Open Research DataThe dataset presents impedance spectrum of Baunier's RC model. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (1 mHz – 100 kHz) was selected in order to test the whole measureement range of the analyzer. In...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on "unknown" object using 2-wire probe
Open Research DataThe dataset presents impedance spectrum of "black-box" object with interesting phase characteristics. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Voltage Source Power Line Conditioner for Applications in Local Supply Systems
PublicationThe paper presents the basic principles of operation of voltage source power line conditioners (VSPLC) as well as their energy and filtration properties. A 4-level cascade based Voltage Source Converter (VSC) is used as a voltage source. The advantages of this topology is relatively simple construction and simple way of balancing DC link voltages. Results of the theoretical and experimental investigations confirm good energetic...
-
SEM images of dewetted gold films
Open Research DataGold nanostructures were prepared on silicon - Si(111) as a substrate. as a result of dewetting process. Thin golds films were deposited using a table-top dc magnetron sputtering coater under pure Ar plasma conditions . The Au target had 99.99% purity, the rate of Au layer deposition was about 0.4 nm·s−1 and the incident power was 32 W. The thickness...
-
Oxidation of silver nanostructures
Open Research DataSilver nanostructures were prepared on Si substrate. Thin Ag films (2 and 6 nm thickness) were deposited using a tabletop dc magnetron sputtering coater (EM SCD 500, Leica) in pure Ar plasma. The Ag target was of 99.99% purity, the rate of layer deposition was about 0.4 nm·s−1 , and the incident power was in the range of 30–40 W. The layer thickness...
-
Experimental investigation of the weight averaging of pulse frequency modulated sensor output signal
Open Research DataThe research aims to practically verify the results of theoretical analysis and simulations of the efficiency of weight averaging of pulse frequency modulated signal. For this purpose, a suitable test stand was built, and the control software in the LabVIEW environment was prepared. Then, a series of experiments were carried out to process and analyze...
-
Symmetrical power line conditioner - basic properties
PublicationIn this paper the basis of analytical modelling of the UPQC arrangements (Unified Power Quality Conditioner) in d-q rotating coordinates, as well as select results of investigations conducted on the simplified small power laboratory model, were talked over. In short form power balance as well as fundamental dependences and analytical model with regard of decoupling circuits, were investigated. Applied method for DC link capacitance...
-
Modeling and experimental investigation of the small UPQC systems
PublicationIn this paper the basis of analytical modelling of the UPQC arrangements (Unified Power Quality Conditioner) in d-q rotating coordinates, as well as select results of investigations conducted on the simplified small power laboratory model were talked over. In short form power balance as well as fundamental dependences and analytic model with regard of decoupling circuits were investigated. Applied method for DC link capacity selection...
-
Wideband Modeling of DC-DC Buck Converter with GaN Transistors
PublicationThe general wideband modeling method of the power converter is presented on the example of DC-DC buck converter with GaN High Electron Mobility Transistors (HEMT). The models of all basic and parasitic components are briefly described. The two methods of Printed Circuit Board (PCB) layout parameter extraction are presented. The results of simulation in Saber@Sketch simulation software and measurements are compared. Next, the model...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on polyvinyl coating using 2-wire probe sample 1
Open Research DataThe dataset presents impedance spectrum of polyvinyl coating (code-name PW_2_2_1) sample 1. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on polyvinyl coating using 2-wire probe sample 2
Open Research DataThe dataset presents impedance spectrum of polyvinyl coating (code-name PW_2_2_1) sample 2. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on nano-nickel based coating using 2-wire probe sample 2
Open Research DataThe dataset presents impedance spectrum of nano-nickel based coating sample 2. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement range of...
-
Testing high impedance analyzer in the field on high-voltage line pylon cell 1 exposition 2
Open Research DataThe dataset presents impedance spectrum of anticorrosion coating on high-voltage line pylon presented in the figure below. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The dataset contains comparative measurements with Atlas-Sollich ATLAS98HI analyser....
-
Testing high impedance analyzer in the field on high-voltage line pylon cell 1 exposition 1
Open Research DataThe dataset presents impedance spectrum of anticorrosion coating on high-voltage line pylon presented in the figure below. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The dataset contains comparative measurements with Atlas-Sollich ATLAS98HI analyser....
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on nano-nickel based coating using 2-wire probe sample 1
Open Research DataThe dataset presents impedance spectrum of nano-nickel based coating sample 1. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement range of...
-
Testing high impedance analyzer in the field on high-voltage line pylon cell 2 exposition 1
Open Research DataThe dataset presents impedance spectrum of anticorrosion coating on high-voltage line pylon presented in the figure below. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The dataset contains comparative measurements with Atlas-Sollich ATLAS98HI analyser....
-
The voltage on bus bars of the main switchboard of the car carrier electrical power system during sea trials
Open Research DataThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results conducted onboard the car carrier during sea trials.
-
The voltage on bus bars of the main switchboard of the car carrier electrical power system at sea trials during maneuvering
Open Research DataThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results conducted onboard the car carrier at sea trials during maneuvering.
-
The voltage on bus bars of the main switchboard of the ro-ro ship electrical power system during a layover at the port
Open Research DataThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results carried out onboard a ro-ro ship during a layover at the port.
-
Comparison of XPS spectra of Ag3d for silver nanostructures and bulk material
Open Research DataAg nanostructures were prepared on borosilicate glass (Corning 1737F) and Si substrates. In both cases, the substrateswere cleaned with acetylacetone and then rinsed in ethanol. Thin Ag films (2 and 6 nm thickness) were deposited using a tabletop dc magnetron sputtering coater (EM SCD 500, Leica) in pure Ar plasma (argon, Air Products 99.999%). The...
-
Analytical Estimation of Power Losses in a Dual Active Bridge Converter Controlled with a Single-Phase Shift Switching Scheme
PublicationMicro-grid solutions around the world rely on the operation of DC/DC power conver- sion systems. The most commonly used solution for these topologies is the use of a dual active bridge (DAB) converter. Increasing the efficiency and reliability of this system contributes to the improvement in the stability of the entire microgrid. This paper discussed an analytical method of energy efficiency and power loss estimation in a single...
-
THREE-LEVEL F-TYPE INVERTER
PublicationGiven the recent available IGBT switch modules up to 6.5 kV, 1200 A rating, the prospect of the diode-free variant topology of the three-level neutral-point-clamped (3-level, T-type) inverter in certain medium voltage applications is bright; due to its small part count and low conduction losses compared to the diode-clamped NPC inverter. However, within this voltage range, the input dc voltage rating of 50% of the switches per...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on epoxy based coating using 2-wire probe sample 2
Open Research DataThe dataset presents impedance spectrum of epoxy based coating (code-name B2_B3) sample 2. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing high impedance analyzer in the field on high-voltage line pylon cell 2 exposition 2
Open Research DataThe dataset presents impedance spectrum of anticorrosion coating on high-voltage line pylon presented in the figure below. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The dataset contains comparative measurements with Atlas-Sollich ATLAS98HI analyser....
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on epoxy based coating using 2-wire probe sample 1
Open Research DataThe dataset presents impedance spectrum of epoxy based coating (code-name B2_B3) sample 1. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on protective foil using 2-wire probe 24h exposition
Open Research DataThe dataset presents impedance spectrum of anticorrosion foil (coating) protecting aluminium frame . This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on protective foil using 2-wire probe 48h exposition
Open Research DataThe dataset presents impedance spectrum of anticorrosion foil (coating) protecting aluminium frame . This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on epoxy based coating using 2-wire probe sample 3
Open Research DataThe dataset presents impedance spectrum of epoxy based coating (code-name EPCS1) sample 3. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
The voltage on bus bars of the main switchboard of the ferry electrical power system during a layover at the port
Open Research DataThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results carried out onboard the ferry during a layover at the port.
-
Investigation of plasmon resonance in a silver nanoparticles
Open Research DataSilver nanostructures were prepared on borosilicate glass (Corning 1737F) substrates. Thin Ag films (1–9 nm thickness) were deposited using a table-top dc magnetron sputtering coater (EM SCD 500, Leica) in pure Ar plasma (argon, Air Products 99.999%). The Ag target was of 99.99% purity, the rate of layer deposition was about 0.4 nm·s−1, and the incident...
-
SEM images of tge gold nanostructures on silicon
Open Research DataAu nanostructures were prepared on Si(111) as a substrate. The substrates (1 × 1 cm2 of area) were cleaned with acetylacetone and then rinsed in ethanol. Thin Au films (with thicknesses in a range of 1.7–5.0 nm) were deposited using a table-top dc magnetron sputtering coater (EM SCD 500, Leica) under pure Ar plasma conditions (Argon, Air Products 99.999%)....
-
Przegląd metod monitorowania stanu technicznego tranzystorów mocy
PublicationW artykule przedstawiono kilka metod monitorowania stanu technicznego tranzystorów mocy, które są lub mogą być wbudowane w układy przekształtnikowe. Celem artykułu jest określenie aktualnego stanu badań na ten temat. Prezentowane metody przeznaczone są do monitorowania istotnych objawów starzenia modułów mocy: rozwarstwiania struktury modułu na skutek termomechanicznego zmęczenia stopu lutowniczego, uszkodzeń połączeń drutowych...
-
Canonical switched capacitor converters. Comments, complements, and refinements
PublicationSwitched Capacitor Converters (SCC) form useful blocks in low/medium power applications as they are suitable for integration, both as off-chip and on-chip IC realizations. However, the problem with SCC is that their voltage conversion ratio is topology-dependent. By changing the SC circuit configuration, we can gain control over voltage conversion but the available ratio remains of a discrete nature, i.e. it maps into a countable...
-
Comprehensive distortion compensation of grid-connected inverter currents
PublicationThe paper presents a comprehensive approach to the compensation of phase current distortion of grid-connected power inverters. Four different sources of current distortion are addressed: imperfect grid synchronization caused by the distortion in the grid voltages, voltage fluctuations in the dc link, time delays in the estimation of grid voltages, and the distortion of inverter output voltages due to dead-time effects and related...
-
Photovoltaic Maximum Power Point Technique based on Incremental Conductance (INCON) control algorithm
PublicationMaximum output power status can significantly improve the deployment rate of solar energy system. In order to get the maximum power output, issue of tracking maximum power point (MPP), reduced harmonics around MPP and improve efficiency of the solar power energy system, this paper presents the improved maximum power point tracking (MPPT) control...
-
Energy, water detailed usage. Living lab testing for sustainable urban food-water-energy cycle.
Open Research DataData set contains detailed, continuous measurements of the usage of water and electrical energy (AC power) in an experimental facility set up in a scientific laboratory (Laboratorium im. B.Niemkiewicza) at the Faculty of Mechanical Engineering and Ocean Technology of the Gdansk University of Technology. The test bed was established in co-operation...
-
A Power-Efficient Digital Technique for Gain and Offset Correction in Slope ADCs
PublicationIn this brief, a power-efficient digital technique for gain and offset correction in slope analog-to-digital converters (ADCs) has been proposed. The technique is especially useful for imaging arrays with massively parallel image acquisition where simultaneous compensation of dark signal non-uniformity (DSNU) as well as photo-response non-uniformity (PRNU) is critical. The presented approach is based on stopping the ADC clock by...
-
Technika MPPT sposobem maksymalizacji wykorzystania energii elektrycznej generowanej przez moduły fotowoltaiczne
PublicationWprowadzenie techniki MPPT (Maximum Power Point Tracking). w systemach fotowoltaicznych umożliwia zwiększenie efektywności przetwarzania energii słonecznej w elektryczną. Technika ta polega na wprowadzeniu do instalacji fotowoltaicznej stosownej, sterowalnej przetwornicy DC/DC, która w połączeniu z odpowiednim algorytmem bądź algorytmami wyszukiwania punktu mocy maksymalnej zapewnia odpowiednie dopasowanie energetyczne modułów...
-
EMI attenuation in a DC-DC buck converter using GaN HEMT
PublicationA dc-dc buck converter using gallium nitride (GaN) high electron mobility transistors (HEMT) is experimentally investigated at the discontinuous current mode (DCM) and at the triangular current mode (TCM) operation. The paper objective is to specify the power conversion efficiency and attenuation of common mode (CM) and differential mode (DM) noise voltage, measured at the line impedance stabilization network (LISN) for compared...
-
An Ultra-Low-Energy Analog Comparator for A/D Converters in CMOS Image Sensors
PublicationThis paper proposes a new solution of an ultra-low-energy analog comparator, dedicated to slope analog-to-digital converters (ADC), particularly suited for CMOS image sensors (CISs) featuring a large number of ADCs. For massively parallel imaging arrays, this number may be as high as tens-hundreds of thousands ADCs. As each ADC includes an analog comparator, the number of these comparators in CIS is always high. Detailed analysis...
-
Nowoczesne układy przekształtników wielopoziomowych do zasilania statków z lądu
PublicationW artykule poruszono tematykę zasilania statków zacumowanych w porcie z lądowej sieci elektroenergetycznej poprzez wykorzystanie nowoczesnych konstrukcji przekształtników energoelektronicznych. W treści pracy zaprezentowano porównanie dwóch topologii wysokonapięciowych przekształtników wielopoziomowych. Porównano konstrukcje przekształtników z klasycznym transformatorem wielouzwojeniowym oraz z transformatorami wysokoczęstotliwościowymi.
-
The voltage on bus bars of the main switchboard of the car carrier electrical power system at sea trials during a sea voyage
Open Research DataThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results conducted onboard the car carrier at sea trials. The data were recorded during a sea voyage, under normal...
-
Formation of gold anostructures detected by SEM microscope
Open Research DataGold nanostructures were prepared on silicon - Si(111) as a substrate. The substrates (1 × 1 cm2 of area) were cleaned with acetylacetone and then rinsed in ethanol. Thin Au films (with thicknesses in a range of 1.7–5.0 nm) were deposited using a table-top dc magnetron sputtering coater (EM SCD 500, Leica) under pure Ar plasma conditions (Argon, Air...
-
Energy, water detailed usage. Living lab testing for sustainable urban food-water-energy cycle. Jan. 2022
Open Research DataData set contains detailed, continuous measurements of the usage of water and electrical energy (AC power) in an experimental facility set up in a scientific laboratory (Laboratorium im. B.Niemkiewicza) at the Faculty of Mechanical Engineering and Ocean Technology of the Gdansk University of Technology. The test bed was established in co-operation...
-
Energy, water detailed usage. Living lab testing for sustainable urban food-water-energy cycle. Dec. 2021
Open Research DataData set contains detailed, continuous measurements of the usage of water and electrical energy (AC power) in an experimental facility set up in a scientific laboratory (Laboratorium im. B.Niemkiewicza) at the Faculty of Mechanical Engineering and Ocean Technology of the Gdansk University of Technology. The test bed was established in co-operation...
-
Four level inverter's DC bus voltage balancing with 3-terminal DAB converter
Publication—Multilevel inverters become more and more popular, especially in the medium or high voltage and high power applications. Unfortunately, some of inverter topologies require additional DC bus voltage balancing systems. This paper presents a novel approach to such systems, which is based on a multiple terminal DAB converter. Along with the voltage balancing function the proposed solution enables the connection of energy storage devices...
-
Horyzont energoelektroniczny obiektów morskich
PublicationW artykule zaprezentowano współczesne kierunki rozwoju energoelektroniki, w tym w szczególności dotyczące obiektów morskich. Przedstawiono podstawowe parametry aktualnie stosowanych w energoelektronice przyrządów półprzewodnikowych, jak również wykazano interdyscyplinarny charakter rozwoju tej dziedziny. Na przykładzie wybranych urządzeń energoelektronicznych przedstawiono ich komercyjne zastosowania oraz podział i miejsce w łańcuchu...