Search results for: CONDUCTORS RESISTANCE
-
Effect of the let-through energy of overcurrent protective devices on the temperature of conductors during short-circuits
PublicationThe scope of the verification of low-voltage systems covers the earth fault loop impedance measurement. This measurement is usually performed with the use of low-value current meters, which force a current many times lower than the one occurring during a real short-circuit. Therefore, the international standard recommends consideration of the increase of resistance of conductors with the increase of temperature, which may occur...
-
Secured wired BPL voice transmission system
PublicationDesigning a secured voice transmission system is not a trivial task. Wired media, thanks to their reliability and resistance to mechanical damage, seem an ideal solution. The BPL (Broadband over Power Line) cable is resistant to electricity stoppage and partial damage of phase conductors, ensuring continuity of transmission in case of an emergency. It seems an appropriate tool for delivering critical data, mostly clear and understandable...
-
Subjective Quality Evaluation of Underground BPL-PLC Voice Communication System
PublicationDesigning a reliable voice transmission system is not a trivial task. Wired media, thanks to their resistance to mechanical damage, seem an ideal solution. The BPL-PLC (Broadband over Power Line – Power Line Communication) cable is resilient to electricity stoppage and partial damage of phase conductors. It maintains continuity of transmission in case of an emergency situation, including paramedic rescue operations. These features...
-
Improvement of Oxygen Electrode Performance of Intermediate Temperature Solid Oxide Cells by Spray Pyrolysis Deposited Active Layers
PublicationIntermediate temperature solid oxide fuel cells oxygen electrodes are modified by active interfacial layers. Spray pyrolysis is used to produce thin (≈500 nm) layers of mixed ionic and electronic conductors: Sm0.5Sr0.5CoO3−δ (SSC), La0.6Sr0.4CoO3−δ (LSC), La0.6Sr0.4Co0.2Fe0.8O3−δ (LSCF), and Pr6O11 (PrOx) on the electrode–electrolyte interface. The influence of the annealing temperature on the electrode polarization (area specific...
-
Protonic Ceramic Fuel Cells as novel electrochemical devices
PublicationProton ceramic conductors are novel materials which are interesting from the application point of view. For example, Protonic Ceramic Fuel Cells (PCFCs) is a type of a solid oxide fuel cell, which uses proton ceramic conductors as an electrolyte. Scientists are looking for the most efficient materials for these devices. In recent years main focus has been put on the search for new proton and mixed proton-electron conductors which...
-
RESEARCH OF PARTIAL DISCHARGE IN THE LABORATORY CONSTRUCTE
PublicationNowadays in the Czech Republic begins implementation of new types of leadership system with insulated conductors nowadays. This system is used because of the use of conductors in difficulties to reach terrains and lower failure rate. The finding of specific faults is problem, because today's digital protection are not able to find it.
-
Przygotowanie, realizacja i ocena pomiarów terenowych do identyfikacji oporności hydraulicznej sieci wodociągowej
PublicationW procesie tworzenia komputerowego modelu przepływów (KMP) jednym z wiodących zadań jest przygotowanie i realizacja pomiarów terenowych w celu identyfikacji oporności hydraulicznej czynnej sieci wodociągowej. Motywacją autora do przedstawienia zasad postępowania w tym zakresie jest narastająca niefrasobliwość twórców KMP, którzy w nieuprawniony sposób używają paramodeli do rozwiązywania problemów inżynierskich. W pracy zdefiniowano...
-
9 - Solid oxide fuel and electrolysis cells
PublicationIn this chapter, the fundamental reactions, the geometrical designs, the material requirements, and the status of SOFCs and SOECs are presented. In the following seven chapters, the most important components of an SOC are described and the chapter ends with a summary and outlook. The described components are: (i) oxygen-ion conductors (electrolyte), (ii) anode materials for SOFCs (cathode in SOEC mode), (iii) cathode materials...
-
Verification of a Novel Method of Detecting Faults in Medium-Voltage Systems with Covered Conductors
PublicationThis paper describes the use of new methods of detecting faults in medium-voltage overhead lines built of covered conductors. The methods mainly address such faults as falling of a conductor, contacting a conductor with a tree branch, or falling a tree branch across three phases of a medium-voltage conductor. These faults cannot be detected by current digital relay protection systems. Therefore, a new system that can detect the...
-
Novel Class of Proton Conducting Materials—High Entropy Oxides
PublicationHere, for the first time, we present data on proton conductivity of high-entropy, single-phase perovskites. The BaZr0.2Sn0.2Ti0.2Hf0.2Ce0.2O3−δ, BaZr0.2Sn0.2Ti0.2Hf0.2Y0.2O3−δ, BaZr1/7Sn1/7Ti1/7Hf1/7Ce1/7Nb1/7Y1/7O3−δ, and BaZr0.15Sn0.15Ti0.15Hf0.15Ce0.15Nb0.15Y0.10O3−δ single-phase perovskites were synthesized. Before electrical measurements, materials were characterized using X-ray diffraction (XRD), scanning electron microscopy...
-
Thermal and Chemical Expansion in Proton Ceramic Electrolytes and Compatible Electrodes
PublicationThis review paper focuses on the phenomenon of thermochemical expansion of two specific categories of conducting ceramics: Proton Conducting Ceramics (PCC) and Mixed Ionic-Electronic Conductors (MIEC). The theory of thermal expansion of ceramics is underlined from microscopic to macroscopic points of view while the chemical expansion is explained based on crystallography and defect chemistry. Modelling methods are used to predict...
-
Structural reliability of overhead power lines by means of Monte Carlo Method and RSM
PublicationThe article discusses the issue of reliability assessment of overhead power lines by means of both Monte Carlo Method and Response Surface Method. The suspension tower OS24 ON150+10 is considered, as the weakest element of the line. A comparison is made between deterministic and probabilistic approaches to wind and icing loading. The PDFs for wind and icing loads are proposed. Reliability is assessed for both critical atmospheric...
-
Determination of Mathematical Model Parameters of a Medium Frequency Transformer
PublicationThe paper presents the results of experimental studies of the medium frequency transformer. The object of the research was a prototype of a single-phase transformer with a core made of ferrite I-core elements and windings made of Litz conductors. The research was carried out to determine the parameters of the transformer's mathematical model. The scope of the tests included determining the magnetic hysteresis loop and measuring...
-
Optimization of microstructure and properties of acceptor-doped barium cerate
PublicationThe presented research concerns acceptor doped barium cerate and the attempts of improvement of its production method that would allow obtaining the solid electrolyte characterized by the particular properties. The authors suggest combining two production methods, molten salt synthesis and self-combustion, in order to achieve the compound material that has some of the advantages of both of the initial methods. An impact of nickel...
-
Impact of configuration of earth continuity conductor on induced sheath voltages in power cables
PublicationIn high voltage power cable systems a problem of induced sheath voltages exist. Due to these voltages electric shock and damage of non-metallic outer sheath of the cables may occur. Exposure to voltage of the outer sheath may be very high in case of earth fault with high value of earth current. In order to reduce induced sheath voltages an earth continuity conductor (conductors) along power cables is applied. Configuration of this...
-
Structure and thermoelectric properties of Bi–Te alloys obtained by novel method of oxide substrates reduction
PublicationA novel method of thermoelectric materials fabrication has been developed. Oxide reagents have been melted at high temperature in air, quenched, milled to powder and reduced in hydrogen to form Bi–Te alloys. Structural and thermoelectric properties of samples have been investigated depending on initial composition and temperature of reduction process. Sample 25Bi2O3–75TeO2 reduced at 340 °C for 10 h has been found to be a p-type...
-
CFD-based evaluation of current-carrying capacity of power cables installed in free air
PublicationEvaluation of current-carrying capacity of power cables and selection of cross-sectional area of their conductors are mainly performed in accordance with requirements of EN, IEC or IEEE standards. However, these standards do not provide all methods of cables installation and location which occur in practice. Thus, in some cases, performance of advanced modeling of various thermal phenomena, affecting power cables current-carrying...
-
Structure and electrical properties of Y, Fe-based perovskite mixed conducting composites fabricated by a modified polymer precursor method
PublicationIn this work, samples of Y0.07Sr0.93Ti1-xFexO3-d with 20, 40, 60 and 80 mol% of iron amount were prepared by a low-temperature polymer precursor method. The SEM-EDS analysis proved that analyzed Y0.07Sr0.93Ti1-xFexO3-d samples were composites of two Ti- and Fe-rich perovskite samples. This kind of composite consists of two phases in which one has a good ionic and the other electronic conductivity, which makes such a composite a...
-
Processing of Ce0.8Gd0.2O2-δ barrier layers for solid oxide cells: The effect of preparation method and thickness on the interdiffusion and electrochemical performance
PublicationCe0.8Gd0.2O1.9 (CGO) barrier layers are required to mitigate the chemical reactions between Sr-containing oxygen electrode materials and Zr-based oxygen ion conductors in high-temperature solid oxide cells. Barrier layers produced by different methods were studied in this work. As a reference, a cell with no barrier layer was measured. The application of the powder-processed barrier layers, considerably increases the performance....
-
Analysis of Induced Voltages and Power Losses in High Voltage Power Cables for Selected Methods of Cables Sheaths Bonding
PublicationPower is increasingly supplied to city centres with 110 kV cable lines. This is a convenient way to supply power, and practically the only one possible in areas of dense urban development. A high-voltage cable contains a coaxial metallic sheath, in which in normal operation and in fault conditions (during short-circuits) significant line-to-earth voltages can be induced, which threatens electric shock and/or damage to the cable’s...
-
Dual-Polarized Wideband Bandpass Metasurface-Based Filter
PublicationThis paper presents a novel metasurface-based bandpass filter. The structure is realized by simply patterning a double-sided AD250 substrate, and does not require any vias or insertion of lumped elements. The top layer is an annular- aperture-array with multiple inner conductors, whereas the bottom layer is a first-order Hilbert-curve array. FEM-based simulation results of the filter are obtained using HFSS. The experimental validation...
-
Subjective Quality Evaluation of Speech Signals Transmitted via BPL-PLC Wired System
PublicationThe broadband over power line – power line communication (BPL-PLC) cable is resistant to electricity stoppage and partial damage of phase conductors. It maintains continuity of transmission in case of an emergency. These features make it an ideal solution for delivering data, e.g. in an underground mine environment, especially clear and easily understandable voice messages. This paper describes a subjective quality evaluation of...
-
Incomplete Cross-Bonding in the MV Line. Experience from the Operation of MV Single Cable Lines
PublicationCable lines are one of the basic components of power systems. Medium and high voltage cables mainly comprise a metallic sheath, which is concentric to the main core conductor. There are several operating schemes of such cable lines, which differ in the place of earthing of sheaths and the possible use of the sheaths and/or conductors crossing. The sheaths cross-bonding is typically done in two places of one cable line section,...
-
Linear and nonlinear impedance in iron oxide glasses containing alkaline ions and alkali free
PublicationThe linear and nonlinear impedance spectra of oxide glasses were measured in the frequency range of 1 mHz to 1 MHz and in the temperature range of 153K to 483K. Two groups of iron oxide glass samples were prepared, the first one containing alkaline ions and the second one without alkali. In the first group, compositions of glasses were as follows: (in %mol) 50% SiO2 , 25% PbO, 15% Fe2O3 and 15% one of alkaline oxides: Na2O, K2O,...
-
Quality Evaluation of Voice Transmission Using BPL Communication System in MV Mine Cable Network
PublicationThis article presents results of a quality evaluation study, considering voice transmission in a 6 kV medium voltage cable network using the BPL (Broadband over Power Line) communication system. The tests are carried out under real mining conditions for the selected power cable without voltage, earthed at both sides. Such a method of monitoring work conditions is of great importance, especially during a disaster. Power cables are...
-
Damage Detection Strategies in Structural Health Monitoring of Overhead Power Transmission System
PublicationOverhead power transmission lines, their supporting towers, insulators and other elements create a highly distributed system that is vulnerable to damage. Typical damage scenarios cover cracking of foundation, breakage of insulators, loosening of rivets, as well as cracking and breakage of lines. Such scenarios may result from various factors: groundings, lightning strikes, floods, earthquakes, aeolian vibrations, conductors galloping,...
-
Voltage variations and their reduction in a rural low-voltage network with PV sources of energy
PublicationRenewable sources of energy (RES), especially photovoltaic (PV) micro-sources, are very popular in many countries. This way of clean power production is applied on a wide scale in Poland as well. The Polish legal regulations and tariffs specify that every prosumer in a low-voltage network may feed this network with a power not higher than the maximum declared consumed power. In power networks with RES, the voltage level changes...