Filters
total: 26
Search results for: NONINVASIVE MEASUREMENT
-
Noninvasive Measurement of Intracranial Pressure: Is It Possible?
Publication -
Urinary Measurement of 8-OxodG, 8-OxoGua, and 5HMUra: A Noninvasive Assessment of Oxidative Damage to DNA
Publication -
Noninvasive method for rotor fault diagnosis in inverter fed induction motor drive
PublicationThis article presents a proposal, simulation and experimental results of a noninvasive rotor fault diagnosis method for the inverter fed induction motor drive. Comparing to reported methods the proposed one does not require any load, rotor brake, slip, mechanical or electrical system physical modification e.g. machine disassembly and can be applied regardless the rotor speed measurement or estimation method.
-
Multi-layered tissue head phantoms for noninvasive optical diagnostics
PublicationExtensive research in the area of optical sensing for medical diagnostics requires development of tissue phantoms with optical properties similar to those of living human tissues. Development and improvement of in vivo optical measurement systems requires the use of stable tissue phantoms with known characteristics, which are mainly used for calibration of such systems and testing their performance over time. Optical and mechanical...
-
In vivo imaging of the human eye using a two-photon excited fluorescence scanning laser ophthalmoscope
PublicationBACKGROUND. Noninvasive assessment of metabolic processes that sustain regeneration of human retinal visual pigments (visual cycle) is essential to improve ophthalmic diagnostics and to accelerate development of new treatments to counter retinal diseases. Fluorescent vitamin A derivatives, which are the chemical intermediates of these processes, are highly sensitive to UV light; thus, safe analyses of these processes in humans...
-
Can we rely on the pulse transit time - pressure relationship - models comparison
PublicationAn unobtrusive, noninvasive and continuous pressure measurement is invaluable however, still being under research and development. There are many attempts proposing an appropriate relationship between pulse pressure velocity and pressure. Fifteen different formulas, both theoretical and experimental, describing relation between blood pressure and crosssectional area of the vessel were examined. Using these formulas the relation...
-
Application of the Fractional Fourier Transform for dispersion compensation in signals from a fiber-based Fabry-Perot interferometer
PublicationOptical methods of measurement do not require contact of a probe and the object under study, and thus have found use in a broad range of applications such as nondestructive testing (NDT), where noninvasive measurement is crucial. Measuring the refractive index of a material can give a valuable insight into its composition. Low‑coherence radiation sources enable measurement of the sample’s properties across a wide spectrum, while...
-
Experimental results of full scattering profile from finger tissue-like phantom
PublicationHuman tissue is one of the most complex optical media since it is turbid and nonhomogeneous. We suggest a new optical method for sensing physiological tissue state, based on the collection of the ejected light at all exit angles, to receive the full scattering profile. We built a unique set-up for noninvasive encircled measurement. We use a laser, a photodetector and finger tissues-mimicking phantoms presenting different optical...
-
Full scattering profile of circular optical phantoms mimicking biological tissue
PublicationHuman tissue is one of the most complex optical media since it is turbid and nonhomogeneous. In our poster, we suggest a new type of skin phantom and an optical method for sensing physiological tissue condition, basing on the collection of the ejected light at all exit angles, to receive the full scattering profile. Conducted experiments were carried out on an unique set-up for noninvasive encircled measurement. Set-up consisted...
-
Assessment of Electronic Sensing Techniques for the Rapid Identification of Alveolar Echinococcosis through Exhaled Breath Analysis
PublicationHere we present a proof-of-concept study showing the potential of a chemical gas sensors system to identify the patients with alveolar echinococcosis disease through exhaled breath analysis. The sensors system employed comprised an array of three commercial gas sensors and a custom gas sensor based on WO3 nanowires doped with gold nanoparticles, optimized for the measurement of common breath volatile organic compounds. The measurement...
-
Gold nanoparticles evaluation using functional optical coherence tomography
PublicationThe main object of this research was to assess the ability to characterize the gold nanoparticles using optical modalities like optical coherence tomography. Since the nanoparticles, especially gold one, have been very attractive for medical diagnosis and treatment the amount of research activities have been growing rapidly. The nanoparticles designed for different applications like contrast agents or drugs delivery change the...
-
Non invasive optical cellular imaging in humans.
PublicationOne of the most appealing and still unsolved problems in biological and medical imaging is the possibility of noninvasive visualization of tissue in vivo with an accuracy of microscopic examination. A major difficulty to solve in biomedical imaging is a degradation of image quality caused by the presence of optical inhomogeneity of tissue. Is there any chance to develop a microscopic method that allows non-invasive observation...
-
Neoplasm, uncertain whether benign or malignant - Female, 46 - Tissue image [5150730018707891]
Open Research DataThis is the histopathological image of THYROID GLAND tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Neoplasm, uncertain whether benign or malignant - Female, 46 - Tissue image [5150730018691711]
Open Research DataThis is the histopathological image of THYROID GLAND tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Neoplasm, uncertain whether benign or malignant - Female, 46 - Tissue image [7040247104953111]
Open Research DataThis is the histopathological image of THYROID GLAND tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Neoplasm, uncertain whether benign or malignant - Female, 46 - Tissue image [515073001870791]
Open Research DataThis is the histopathological image of THYROID GLAND tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Neoplasm, uncertain whether benign or malignant - Female, 46 - Tissue image [5150730018707841]
Open Research DataThis is the histopathological image of THYROID GLAND tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Non-invasive blood glucose monitoring with Raman spectroscopy: prospects for device miniaturization
PublicationThe number of patients with diabetes has reached over 350 million, and still continues to increase. The need for regular blood glucose monitoring sparks the interest in the development of modern detection technologies. One of those methods, which allows for noninvasive measurements, is Raman spectroscopy. The ability of infrared light to penetrate deep into tissues allows for obtaining measurements through the skin without its...
-
CyberEye: New Eye-Tracking Interfaces for Assessment and Modulation of Cognitive Functions beyond the Brain
PublicationThe emergence of innovative neurotechnologies in global brain projects has accelerated research and clinical applications of BCIs beyond sensory and motor functions. Both invasive and noninvasive sensors are developed to interface with cognitive functions engaged in thinking, communication, or remembering. The detection of eye movements by a camera offers a particularly attractive external sensor for computer interfaces to monitor,...
-
Machine Learning and Electronic Noses for Medical Diagnostics
PublicationThe need for noninvasive, easy-to-use, and inexpensive methods for point-of-care diagnostics of a variety of ailments motivates researchers to develop methods for analyzing complex biological samples, in particular human breath, that could aid in screening and early diagnosis. There are hopes that electronic noses, that is, devices based on arrays of semiselective or nonselective chemical sensors, can fill this niche. Electronic...
-
Receptor for advanced glycation end‐products: Biological significance and imaging applications
PublicationThe receptor for advanced glycation end-products (RAGE or AGER) is a transmembrane, immunoglobulin-like receptor that, due to its multiple isoform structures, binds to a diverse range of endo- and exogenous ligands. RAGE activation caused by the ligand binding initiates a cascade of complex pathways associated with producing free radicals, such as reactive nitric oxide and oxygen species, cell proliferation, and immunoinflammatory...
-
A Flexible Nafion Coated Enzyme‐free Glucose Sensor Based on Au‐dimpled Ti Structures
PublicationThe detection of glucose at low concentrations using electrochemical sensors is of great importance due to the possibility of using different human body fluids than blood, such as e.g. urine, saliva, sweat or tears. The interest behind those biofluids is related to their utility in non-invasive sugar determination. In this work, we present flexible, fully biocompatible electrode material based on Au nanoparticles immobilized onto...
-
Analysis of friction ridge evidence for trace amounts of paracetamol in various pharmaceutical industries by Raman spectroscopy
PublicationThe detection of potentially harmful substances presents a multifaceted challenge. On one hand, it can directly save lives, on the other, it can significantly aid and enhance police work, thereby increasing the effectiveness of investigations. The research conducted in this study primarily aims to identify paracetamol in fingerprints, considering situations involving direct contact of a person with paracetamol either chronically...
-
Wykorzystanie kamery termowizyjnej nowej generacji do oceny wpływu sił ortodontycznych na dziąsło = The application of a new-generation thermal imaging camera for the assessment of hemodynamic changes in gingiva during orthodontic treatment
PublicationIntroduction. One ot the most interesting modern methods of assessing microcirculation is thermovisiual examination. Thermovision cameras are commonly used in general medicine. As the periodontium is one of the most vascularized tissues in the human body, the application of high-sensitivity thermovision cameras may allow tor noninvasive asses- sment and early detection ot pathological changes in the gingiva by giving a complete...
-
A pilot study with flow mediated skin fluorescence: A novel device to assess microvascular endothelial function in coronary artery disease
PublicationBackground: Endothelial dysfunction is one of the earliest vascular manifestations in the pathogenesis of cardiovascular disease. Noninvasive, simple and inexpensive methods of endothelial function assessment are therefore needed. Methods: Microvascular endothelial function was assessed in coronary artery disease (CAD) patients by flow mediated skin fluorescence (FMSF), based on measurements of NADH fluorescence intensity during...
-
BLOOD PRESSURE ESTIMATION BY MEANS OF A JOINT IMPEDANCE– PHOTOPLETYSMOGRAPHIC METHOD
PublicationThe knowledge of patient’s day to day blood pressure changes is invaluable to physicians for both diagnostics and health monitoring reasons. Constant observation of the pressure throughout a day would provide even more valuable clinical information. A convenient non-invasive methods of blood pressure estimation for monitoring purposes are widely proposed. This work shows a statistical approach to...