Using the MultiRAEPro Gas Detector to Monitor Odour Emissions from Biogas Plants Processing Municipal Waste
Publication -
Radioisotope measurement of selected parameters of liquid-gas flow using single detector system
PublicationTo determine the parameters of two-phase flows using radioisotopes, usually two detectors are used. Knowing the distance between them, the velocity of the dispersed phase is calculated based on time delay estimation. Such a measurement system requires the use of two gamma-ray sealed sources. But in some situations it is also possible to determine velocity of dispersed phase using only one scintillation probe and one gamma-ray source....
-
Application and optimization of headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography - flame-ionization detector (GC-FID) to determine products of the petroleum industry in aqueous samples
PublicationA simple and solvent-free analytical method has been optimized for the determination of hydrocarbons (C6 - C20) from products of the petroleum industry in aqueous samples. Extraction and analysis was carried out using headspace solid-phase microextraction (HS-SPME) and gas chromatography coupled with flame-ionization detector (GC-FID). A ZB-5 capillary column (30 m × 0.25 mm inner diameter, 0.25 µm film thickness) was used for...
-
Dopants and gas modifiers in ion mobility spectrometry
PublicationThe ion mobility techniques, including the most commonly used drift-tube ion mobility spectrometry (IMS) and differential mobility spectrometry (DMS), are used successfully for the detection of a wide range of organic compounds in the gas phase. In order to improve detection quality, admixtures are added to gas streams flowing through the detector. Dopants mostly prevent the ionization of interfering chemicals however, better detection...
-
TOXIC GASES IDENTIFICATION USING SINGLE ELECTROCATALYTIC SENSOR RESPONSES AND ARTIFICIAL NEURAL NETWORK
PublicationThe need for precise detection of toxic gases drives development of new gas sensors structures and methods of processing the output signals from the sensors. In literature, artificial neural networks are considered as one of the most effective tool for the analysis of gas sensors or sensors arrays responses. In this paper a method of toxic gas components identification using a electrocatalytic gas sensor as a detector and an artificial...
-
Separation of Volatile Oxygen-containing Organic Compounds by Gas Chromatography - selectivity comparison of different polarity stationary phases
PublicationThis paper present a results of the separation of 36 reference compounds belonging to the group of Volatile Oxygen-Containing Organic Compounds (OVOCs) using capillary gas chromatography with flame ionization detector (GC-FID) and three stationary phases of different polarity. A selectivity has been studied regarding to OVOCs and n -alkanes. The most useful for the separation of the group OVOCs is a polar ionic liquid stationary...
-
A procedure for the determination of dichloromethane and tetrachloroethene in water using pervaporation and gas chromatography
PublicationIn the present study, pervaporation was applied to the determination of tetrachloroethene (PCE) and dichloromethane (DCM) in liquid samples. PCE is the most commonly used solvent in dry-cleaning processes. PCE belongs to group 2A of carcinogens (probably carcinogenic to humans) according to the classification of the International Agency for Research on Cancer (IARC). DCM is also widely used as an industrial solvent for the purification...
-
Kinetics of hexane and cyclohexane biodegradation using Candida subhashii in mineral salt medium in the presence of DES solution
Open Research DataDataset presents results of investigations on kinetics of biodegradation of hexane and cyclohexane in Candida subhashii.
-
Application of a Gas Sensor Array to Effectiveness Monitoring of Air Contaminated with Toluene Vapors Absorption Process
PublicationThis article demonstrates the application of a gas sensor array to monitor the effectiveness of the absorption process of air stream purification from odorous compounds (toluene vapors). A self-constructed matrix consisting of five commercially available gas sensors was used. Multiple linear regression (MLR) was selected as the statistical technique used to calibrate the matrice. Gas chromatography coupled with a flame ionization...
-
EVALUATION OF LIQUID-GAS FLOW IN PIPELINE USING GAMMA-RAY ABSORPTION TECHNIQUE AND ADVANCED SIGNAL PROCESSING
PublicationLiquid-gas flows in pipelines appear in many industrial processes, e.g. in the nuclear, mining, and oil industry. The gamma-absorption technique is one of the methods that can be successfully applied to study such flows. This paper presents the use of thegamma-absorption method to determine the water-air flow parameters in a horizontal pipeline. Three flow types were studied in this work: plug, transitional plug-bubble,...
-
Thermal degradation assessment of canola and olive oil using ultra-fast gas chromatography coupled with chemometrics
PublicationOil blending is often used to enhance the properties of vegetable oils. The admixture of a more thermally stable oil makes the resulting blend more suitable for use in frying. A new method of quality assessment of vegetable oils used in frying is presented in this paper. In this method, ultra-fast gas chromatography coupled with flame ionization detector and chemometrics is employed. Principal component analysis was used for data...
-
Photocatalytic ethylene decomposition with the use of fluidized bed photoreactor
Open Research DataData contain exported raw data recorded during decomposition of ethylene during utilization of fluidized bed photoreactor equipped with either UV-LEDs or fluorescent UV lamps as well as in either humid or dry conditions. In separate folder, the photographs of the photocatalytic system were included. As photocatalytic material, polystyrene spheres coated...
-
Size-exclusion chromatography for the determination of the boiling point distribution of high-boiling petroleum fractions
PublicationThe paper describes a new procedure for the determination of boiling point distribution of high-boiling petroleum fractions using size exclusion chromatography with refractive index detector. Thus far, the determination of boiling range distribution by chromatography has been accomplished using simulated distillation with gas chromatography with the flame ionization detection. This study revealed that in spite of substantial differences...
-
Investigation of volatile low molecular weight compounds formed during continuous reclaiming of ground tire rubber
PublicationGround tire rubber was thermo-mechanically reclaimed at different temperature conditions (80, 120, 160 °C) using a co-rotating twin screw extruder. The progress of ground tire rubber reclaiming was evaluated with specific mechanical energy, sol fraction and thermogravimetric analysis. Volatile organic compounds (VOCs) including volatile sulfur compounds (VCSs) released from ground tire rubber and ground tire rubber after reclaiming...
-
Analysis of pesticide residue in tomato samples using analytical protocol based on application of QuEChERS technique and GC-ECD system
PublicationQuEChERS sample preparation method was used for the determination of 10 pesticides and their metabolites in tomato samples, coupled to gas chromatography with electron capture detector (GCECD). The experimental parameters including oven temperature program, amount of the sample and purifying agent were optimized. The GC-ECD method was validated in terms of linearity, selectivity and recovery. The limits of detection (LODs) of the...
-
Understanding the early-stage release of volatile organic compounds from rapeseed oil during deep-frying of tubers by targeted and omics-inspired approaches using PTR-MS and gas chromatography
PublicationDuring deep-frying, a plethora of volatile products is emitted with the fumes. These compounds could act as oil quality indicators and change the indoor air composition leading to health risks for occupants. The presented experiments focus on deep-frying of different tubers in rapeseed oil at different frying temperatures. Here, two scenarios for real-time monitoring of volatile organic compounds (VOCs) using proton transfer reaction...
-
Direct-Ultrasonic Assisted Microextraction Coupled with RTL-GC-FID/GC-MS as a Future Standard Procedure for Monitoring 26 potentially Allergenic Fragrances in Water Samples
PublicationThis research topic grew up as a result of awareness of constant anthropogenic and natural input to the environment constituents of personal care products (PCPs) residues. This group of emerging pollutants encompasses a wide range of chemicals, including potentially allergenic fragrance compounds. The aim of the present study was to investigate presence of 26 fragrance allergens in water samples. Simple and rapid methodology based...
-
Processing, Performance Properties, and Storage Stability of Ground Tire Rubber Modified by Dicumyl Peroxide and Ethylene-Vinyl Acetate Copolymers
PublicationIn this paper, ground tire rubber was modified with dicumyl peroxide and a variable content (in the range of 0–15 phr) of ethylene-vinyl acetate copolymers characterized by different vinyl acetate contents (in the range of 18–39 wt.%). Modification of ground tire rubber was performed via an auto-thermal extrusion process in which heat was generated during internal shearing of the material inside the extruder barrel. The processing,...
-
Effects of liquid phase modification on the performance of biotrickling filters
Open Research DataDataset presents the effects of liquid phase modification on the biotrickling filtration (BTF) performance of air polluted with toluene, ethylbenzene, xylene and styrene.
-
Experimental and theoretical studies on the photodegradation of 2-ethylhexyl 4-methoxycinnamate in the presence of reactive oxygen and chlorine species
Publication2-Ethylhexyl 4-methoxycinnamate (EHMC) is one of the most commonly used sunscreen ingredient. In this study we investigated photodegradation of EHMC in the presence of such common oxidizing and chlorinating systems as H2O2, H2O2/HCl, H2O2/UV, and H2O2/HCl/UV. Reaction products were detected by gas chromatography with a mass spectrometric detector (GC-MS). As a result of experimental studies chloro-substituted 4-methoxycinnamic...