Filters
total: 7279
filtered: 5043
-
Catalog
- Publications 5043 available results
- Journals 60 available results
- Conferences 8 available results
- Publishing Houses 1 available results
- People 153 available results
- Inventions 1 available results
- Projects 11 available results
- Laboratories 2 available results
- Research Teams 1 available results
- Research Equipment 7 available results
- e-Learning Courses 72 available results
- Events 5 available results
- Open Research Data 1915 available results
Chosen catalog filters
displaying 1000 best results Help
Search results for: ECG MEASUREMENTS
-
Estimation of electrode contact in capacitive ECG measurement
PublicationIn the paper a method of electrode’s contact estimation in capacitive electrocardiogram (CECG) is presented. Proposed solution allows estimation of contact quality for each individual electrode. This enables construction of multi-electrode CECG systems, where electrode pairs can be selected on the basis of the individual electrode contact quality.
-
Capacitively coupled ECG measurements - a CMRR circuit improvement
PublicationA typical galvanic-connected electrocardiogram (ECG) measurement system utilizes two signal’s electrodes and a third one in driven-right-leg (DRL) circuit for improving a common-mode rejection ratio(CMRR) of the acquisition system. In capacitive-coupled ECG similar techniques are used, however it is expected, that the utilized DRL subsystem is formed using a capacitive coupling approach, too. An improvement of the acquisition system...
-
A scale with ECG measurements capability for home cardiac monitoring
PublicationPresented device -a scale developed for enabling extra measurements, in addition to body weight and composition, the electrical activity of the heart (electrocardiogram - ECG) and the level of oxygen saturation in the blood SaO2. Electrical activity is recorded in the form of six leads, socalled - limb leads. The device allows measurement of all standard limb leads and without the need for additional procedures. ECG, although the...
-
Electrodes array for contactless ECG measurement of a bathing person - a sensitivity analysis
PublicationAn applicability of a remote (contactless) electrocardiogram (ECG) measurements in a bathtub is presented in the paper. Possibility of ECG measurements in shallowly filled tube with a water was examined. A bathing person was, both, sitting and lying during experiments performed. The problem became non-trivial when the bathing person was moving in reference to a fixed set of electrodes and located at the longer walls of the bathtub....
-
Balance recognition on the basis of EEG measurement.
PublicationAlthough electroencephalography (EEG) is not typically used for verifying the sense of balance, it can be used for analysing cortical signals responsible for this phenomenon. Simple balance tasks can be proposed as a good indicator of whether the sense of balance is acting more or less actively. This article presents preliminary results for the potential of using EEG to balance sensing....
-
ECT image analysis methods for shear zone measurements during silo discharging process
PublicationW pracy przedstawiono wyniki pomiarów zmian koncentracji piasku bezkohezyjnego zachodzących w cylindrycznym modelu silosu opróżnianym grawitacyjnie, w którym występowały silne efekty dynamiczne. Pomiary wykonano z zastosowaniem tomografii pojemnościowej. Badania przeprowadzono dla zróżnicowanego zagęszczenia początkowego piasku oraz różnego stopnia szorstkości ścian. Szczegółowej analizie poddano zmianę koncentracji materiału sypkiego...
-
Application of ECT to solid concentration measurements during granular flow in a rectangular model silo.
PublicationW artykule przedstawiono wyniki doświadczeń pomiaru zmian koncentracji materiału granulowanego podczas przepływu silosowego w silosie prostokątnym. Zmiany zostały pomierzone przy pomocy tomografu. Doświadczenia wykonano w modelu silosu dla różnych szorstkości ścian i różnych zagęszczeń suchego piasku.
-
Measurement of dynamic pulsations in bulk solid during silo discharging using ECT method
PublicationW pracy przedstawiono wyniki pomiarów pulsacji materiału sypkiego pomieroznych z zastosowaniem metody pomiarowej ECT. Analizę dynamicznych zmian koncetracji przperowadzono dla podstawowych(surowych) danych pomiarowych oraz danych zrekonstruowanych
-
Smart Weighing Scale with Feet-Sampled ECG
PublicationIn a smart home, health and well-being monitoring systems could be embedded in everyday devices providing a pervasive care. A home bathroom scale is an example of such a device, typically used to measure body weight and very often its composition (e.g. body water/fat percentage). In this paper, we analyzed a potential use of the bathroom scale to measure electrocardiogram (ECG) from electrodes located on the scale's tile. In particular...
-
A body position influence on ECG derived respiration
PublicationAn influence of a human body position on ECG derived respiration (EDR) signal is presented in the paper. Examinations were performed during deep, suspended and normal breathing for eight people in four different body positions. EDR and thoracic impedance signals were compared using correlation and standard deviation coefficients. Obtained results have shown that it is possible to monitor breath activity of people being in different...
-
Optimal ECG lead for deriving respiratory signal
PublicationEDR is an interesting measuring technique that allows an indirect assessment of respiratory activity. This is an alternative solution to direct methods that are based on the measurement of air flow, which require a specialized sensor or even a system. However, due to inter-personal anatomical differences, the optimal ECG lead (placement of the electrodes) ensuring the best EDR signal quality is not fixed. An influence of ECG lead...
-
Application of electrical capacitance tomography (ECT) to measurement of sand concentration changes during silo flow
PublicationW artykule przedstawiono wyniki doświadczeń pomiaru zmian koncentracji materiału granulowanego podczas przepływu silosowego. Zmiany zostały pomierzone przy pomocy tomografu. Doświadczenia wykonano w silosie cylindrycznym dla 2 różnych szorstkości ścian.
-
ECG-based prediction of ventricular fibrillation by means of the PCA
PublicationA Sudden Cardiac Death (SCD) is a death resulting from cardiac failure with no significant symptoms earlier than one hour before occurrence. It is the cause of for approximately 400000 deaths per year in United States and millions of deaths worldwide. The proposed system, including two-stage algorithm and wearable diagnostic device allows for SCD risk estimation and continuous monitoring of high risk patients. A single channel...
-
The issue of uncertainty of visual measurement techniques for long distance measurements based on the example of applying electric traction elements in diagnostics and monitoring
PublicationRail transport is the most economical and energy-effective in the field of land transport, in particular electrified. In order to ensure efficient and reliable operation of electrified rail transport, the issues of monitoring and diagnostics of the traction infrastructure and vehicles are extremely important. The most critical point in the transmission of electric energy to the vehicle is the sliding contact of the current collector...
-
Non-Contact Monitoring of ECG in the Home Environment—Selecting Optimal Electrode Configuration
PublicationCapacitive electrocardiography (cECG) is most often used in wearable or embedded measurement systems. The latter is considered in the paper. An optimal electrocardiographic lead, as an individual feature, was determined based on model studies. It was defined as the possibly highest value of the R-wave amplitude measured on the back of the examined person. The lead configuration was also analyzed in terms of minimizing its susceptibility...
-
Field measurements
PublicationThe article presents the scope and methodologies used in the course of geodetic measurements accompanying archaeological excavations in the area of the Wisłoujście Fortress in Gdańsk
-
DETECTION OF BREATHING AND HEART RATE USING AN ECG SIGNAL MEASURED WHILE BATHING IN THE BATHTUB
PublicationNowadays a new area of interest is gaining importance - it is home biomedical examination. Intelligent home can be supported by set of devices for habitants observation. It can be particularly useful for elders or person with some health risks but living alone. One of critical locations within the house is bathroom. One of utilities in the bathroom is a bathtub which is sometimes preferred over shower. There are reports of problems...
-
APPLICATION OF STATISTICAL FEATURES AND MULTILAYER NEURAL NETWORK TO AUTOMATIC DIAGNOSIS OF ARRHYTHMIA BY ECG SIGNALS
PublicationAbnormal electrical activity of heart can produce a cardiac arrhythmia. The electrocardiogram (ECG) is a non-invasive technique which is used as a diagnostic tool for cardiac diseases. Non-stationarity and irregu- larity of heartbeat signal imposes many difficulties to clinicians (e.g., in the case of myocardial infarction arrhythmia). Fortunately, signal processing algorithms can expose hidden information within ECG signal contaminated...
-
Linearization in impedance measurements
Publication -
Stochastic resonance in measurements
PublicationNoise is usually associated with the negative phenomenon, hampering the measurements data and their analysis. This view has been broken in the '80s when the phenomenon of stochastic resonance (Stochastic Resonance - SR) was discovered. It is a phenomenon that occurs in nonlinear dynamic measurement systems when the selected input noise can optimize system performance. SR became a way to improve efficiency of weak signals detection....
-
HYDROACOUSTIC NOISE MEASUREMENTS
PublicationThe paper deals mainly with investigation of underwater noise that propagation is in shallow water. In this paper has been presented the experimental investigation results concerning the distribution of the sound field pressure generated by moving ships in the shallow water at the small distance from the ship. The main acoustical characteristics describing features of the field are spectrograms in pseudo 3D system – distance and frequency...
-
Asymmetric Properties of the Heart Rate Microstructure in Healthy Adults during 48 h ECG Recordings
Publication -
Entropy Measures of heart rate variability for short ECG datasets in patients with congestive heart failure
PublicationWe investigated the usefulness of entropy measures calculated for short ECG series in distinguishing healthy subjects from patients with congestive heart failure (CHF). Four entropy measures were tested: Approximate Entropy (ApEn), Sample Entropy (SampEn), Fuzzy Entropy (Fuzzy En) and Permutation Entropy (PE), each computed for ECG series of 1000, 500, 250 and 100 RR intervals. We found that with a reduction of the data set length...
-
Entropy measures of heart rate variability for short ECG datasets in patients with congestive heart failure
PublicationWe investigated the usefulness of entropy measures calculated for short ECG series in distinguishing healthy subjects from patients with congestive heart failure (CHF). Four entropy measures were tested: Approximate Entropy (ApEn), Sample Entropy (SampEn), Fuzzy Entropy (FuzzyEn) and Permutation Entropy (PE), each computed for ECG series of 1000, 500, 250 and 100 RR intervals. We found that with a reduction of the data set length...
-
Joint Analysis of National Eco-Efficiency, Eco-Innovation and SDGs in Europe: DEA Approach
PublicationThe growing complexity and intertwining of different socio-economic issues both in individual countries and internationally mean that single-theme analyses do not consider all the relationships and thus have cognitive limitations. Therefore, studies that combine several research areas are increasingly common in the literature to clarify the connections and relationships. In this study, considering the sequential nature of the...
-
JOINT ANALYSIS OF NATIONAL ECO-EFFICIENCY, ECO-INNOVATION AND SDGS IN EUROPE: DEA APPROACH
Publication -
A comprehensive survey on low-cost ECG acquisition systems: Advances on design specifications, challenges and future direction
Publication -
A comprehensive survey on low-cost ECG acquisition systems: Advances on design specifications, challenges and future direction
PublicationAvailability of low-cost, reliable, and portable Electrocardiography (ECG) devices is still very important in the medical world today. Despite the tremendous technological advancement, Cardiovascular Diseases (CVDs) remain a serious health burden claiming millions of lives on an annual basis globally. This is more prevalent in Low and Middle-Income Countries (LMICs) where there are huge financial instability and lack of critical...
-
Blood Pressure Estimation Based on Blood Flow, ECG and Respiratory Signals Using Recurrent Neural Networks
PublicationThe estimation of systolic and diastolic blood pressure using artificial neural network is considered in the paper. The blood pressure values are estimated using pulse arrival time, and additionally RR intervals of ECG signal together with respiration signal. A single layer recurrent neural network with hyperbolic tangent activation function was used. The average blood pressure estimation error for the data obtained from 21 subjects...
-
Techniki śródoperacyjnego monitorowania EKG
PublicationZ badania EKG lekarze uzyskują szereg cennych informacji niezbędnych do prawidłowego podejmowanie ważnych decyzji terapeutycznych. EKG stało się pierwszym parametrem monitorowanym standardowo i w sposób ciągły podczas znieczulenia. Współczesna technika umożliwia nie tylko ciągłe monitorowanie zapisu EKG, a także transmisję danych on-line do dowolnego miejsca w szpitalu, i ich cyfrową rejestrację. Najistotniejszym kryterium przydatności...
-
Mobility measurements in oxide semiconductors
PublicationPraca zawiera wyniki badań właściwości elektrycznych, optycznych i strukturalnych cienkich warstw ito i sno2. badania wykazały, że cienkie warstwy tlenków metali wykazują rezystywność charakterystyczną dla półprzewodników. poziom transmisji światła w zakresie widzialnym pozwala zaliczyć badane warstwy do materiałów przezroczystych. badane cienkie warstwy wykonano metodą rozpylania magnetronowego.
-
Speech Intelligibility Measurements in Auditorium
PublicationSpeech intelligibility was measured in Auditorium Novum on Technical University of Gdansk (seating capacity 408, volume 3300 m3). Articulation tests were conducted; STI and Early Decay Time EDT coefficients were measured. Negative noise contribution to speech intelligibility was taken into account. Subjective measurements and objective tests reveal high speech intelligibility at most seats in auditorium. Correlation was found between...
-
Reliability of Pulse Measurements in Videoplethysmography
PublicationReliable, remote pulse rate measurement is potentially very important for medical diagnostics and screening. In this paper the Videoplethysmography was analyzed especially to verify the possible use of signals obtained for the YUV color model in order to estimate the pulse rate, to examine what is the best pulse estimation method for short video sequences and finally, to analyze how potential PPG-signals can be distinguished from...
-
Optoelectronic device for hematocrit measurements
PublicationAn optoelectronic system for measurements of hematocrit level (HCT) in the whole human blood is presented. Proposed system integrates a dedicated optoelectronic sensor, a microcontroller and a small LCD display in a low cost, battery-powered, handheld device. Chosen method for determining blood hematocrit level is based on optical properties of whole blood in visible and NIR wavelength range. Measurements with the use of proposed...
-
Measurements of the Hydraulic Fluids Compressibility
PublicationPerformance of the hydrostatic high-pressure drive systems is affected by the changes of working fluid’s volume. Presence of air bubbles in the fluid cause this problem to be even more serious. To study this phenomenon precise measurements of fluid’s bulk modulus are necessary. Differ-ent measurement methods are applied, but they are either limited to low pressure range or give inaccurate results. To solve the problem the new...
-
Measurements of Subnanometer Molecular Layers
PublicationSelected methods of formation and detection of nanometer and subnanometer molecular layers were shown. Additionally, a new method of detection and measurement with subnanometer resolution of layers adsorbed or bonded to the gate dielectric of the ion selective field effect transistor (ISFET) was presented.
-
Measurements of relative frequency instability
PublicationFrequency constancy can be determined by the change in time for the subsequent periods. The article shows that classical the method of digital period measurement is not suitable for the measurement process. Therefore, a method using an integrating circuit is being proposed. Errors in the measurement of the given method have been analyzed.
-
Revisiting the Measurement of Anomie
Publication -
MEASUREMENT OF NOISE IN SUPERCAPACITORS
PublicationA developed method and measurement setup for measurement of noise generated in a supercapacitor is presented. The requirements for noise data recording are considered and correlated with working modes of supercapacitors. An example of results of low-frequency noise measurements in commercially available supercapacitors are presented. The ability of flicker noise measurements suggests that they can be used to assess quality of tested supercapacitors.
-
Accuracy Analysis of Measurements in Electrochemical Biosensing
Publication -
Rolling resistance measurements of studded tires
PublicationW pracy przedstawiono wyniki pomiaru oporu toczenia opon kolcowanych i po usunięciu kolców na nawierzchni poroelastycznej. Badania przeprowadzono na stanowisku bębnowym Katedry Pojazdów i Maszyn Roboczych Politechniki Gdańskiej. Opony kolcowane mają o około 5% wyższy współczynnik oporu toczenia w porównaniu z oponami nie kolcowanymi.
-
Hardness measurements for assessment of cavitation intensity
PublicationArtykuł opisuje możliwość zastosowania pomiarów teardości erodowanego materiału do oceny natężenia zjawiska kawitacji. Proponowana metoda zakłada, że cała energia implodujących pęcherzyków kawitacyjnych zamieniana jest na przyrost twardości warstwy wierzchniej materiału
-
Emissivity Measurements on Shape Memory Alloys
Publication -
AC loss measurements in superconducting magnet
PublicationThis report contains ordered theoretical informations about AC loss in superconducting magnets and cables. A software program to evaluate data from AC loss measurements with V-I method was made and it is also described. Examples of measurement data and result data are shown here.
-
Methods of Tire Rolling Resistance Measurements
PublicationTire rolling resistance is one of the factors related to tire/road interaction that has important influence on road vehicles performance. Raising fuel price and increased concern related to the environmental changes result in growing interest in reduction of tire rolling resistance that influences fuel consumption, especially in free-flowing highway traffic with moderate speeds. There are several methods of tire rolling resistance measurements....
-
Simulation and measurements for the substance identification by AFM
Publication -
Measurements of droplet contact angle of nanofluids
PublicationPrzedstawiono wyniki pomiarów kąta zwilżania trzech nanocieczy: woda-Al2O3, woda-TiO2 oraz woda-Cu. Koncentracja nanocząstek wynosiła: 0.01%, 0.1% oraz 1%. Pomiary przeprowadzono dla podłoża szklanego, aluminiowego i ze stali nierdzewnej. Kąt zwilżania mierzono za pomocą goniometru, a także na podstawie zdjęć wykonanych za pomocą kamery cyfrowej.
-
Measurements and Simulations of Engineered Ultrasound Loudspeakers
PublicationSimulation and measurement results of the sound emitted from an ultrasound custom-made system with high spatial directivity are presented. The proposed system is using modulated ultrasound waves which demodulate in nonlinear medium resulting in audible sound. The system is aimed at enhancing the users’ personal audio space, therefore the measurements are performed using the Head and Torso Simulator which provides realistic reproduction...
-
Measurements of electron drift velocity in OCS
PublicationWykonano pomiary prędkości dryfu elektronów w funkcji zredukowanego pola elektrycznego E/N. Wyniki tych pomiarów porównano z wynikami pomiarów w CO2 i N2O.
-
Computer-aided Measurements of Turbine Blades
PublicationPrzedstawiono skomputeryzowane pomiary profili łopatek turbinowych po szlifowaniu. W pracy wykorzystano program komputerowy, który może być zastosowany bezpośrednio przez operatora obrabiarki, opracowany na bazie Microsoft Excel.