Filters
total: 5064
-
Catalog
- Publications 2265 available results
- Journals 68 available results
- Conferences 1 available results
- Publishing Houses 1 available results
- People 108 available results
- Inventions 8 available results
- Projects 9 available results
- Laboratories 1 available results
- Research Equipment 2 available results
- e-Learning Courses 245 available results
- Events 4 available results
- Open Research Data 2352 available results
displaying 1000 best results Help
Search results for: MUSCLE EMG
-
Invasive breast carcinoma of no special type - Male, 33 - Tissue image [1160630015011801]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Atypical polypoid adenomyoma - Female, 38 - Tissue image [6120730031808401]
Open Research DataThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Ductal carcinoma in situ, NOS - Female, 40 - Tissue image [9210729554616761]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobular carcinoma, NOS - Female, 44 - Tissue image [10100730045427961]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
LanroNET, a non-interventional, prospective study to assess the resource utilization and cost of lanreotide autogel 120 mg in Polish patients with neuroendocrine tumors – results of interim analysis
Publication -
Expanded graphite assistant construction of gradient-structured char layer in PBS/Mg(OH)2 composites for improving flame retardancy, thermal stability and mechanical properties
Publication -
Rapid Re-Design and Bandwidth/Size Trade-Offs for Compact Wideband Circular Polarization Antennas Using Inverse Surrogates and Fast EM-Based Parameter Tuning
PublicationDesign of compact wideband circularly polarized (CP) antennas is challenging due to the necessity of simultaneous handling of several characteristics (reflection, axial ratio, gain) while maintaining a small size of the structure. Antenna re-design for various operating bands is clearly more difficult yet practically important because intentional reduction of the bandwidth (e.g., by moving the lower edge of the operating band up...
-
IMPULSE NOISE ASSOCIATED WITH FIRING HANDHELD MILITARY WEAPONS
PublicationSports, hunting and military shooting grounds are well known sources of noise that can be disruptive both for people present at those facilities, as well as for people and animals that live nearby. What is more, shooters are also subjected to very painful and dangerous impulse noise. The paper discusses the issues related to the noise immission during firing of small firearms of military type that are typical for Poland. The experiments...
-
Revista de Estudos e Pesquisas Interdisciplinares em Musicoterapia
Journals -
Revista de Gestao em Sistemas de Saude-RGSS
Journals -
REMEA-Revista Eletronica do Mestrado em Educacao Ambiental
Journals -
Perspectivas em Dialogo-Revista de Educacao e Sociedade
Journals -
Revista Gedecon Revista Gestao e Desenvolvimento em Contexto
Journals -
Intraductal papilloma - Female, 48 - Tissue image [10110730048229131]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Fibromatosis-like metaplastic carcinoma - Female, 65 - Tissue image [8120730007228551]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
The role of epigenetics in regeneration
PublicationComplex changes in chromatin structure and at the transcriptional level occur from the creation of a single parental gamete throughout fertilization, embryo development and the life of an adult organism. Epigenetic changes, such as methylation and hydroxymethylation of DNA or histone methylation and acetylation, are an important part of these processes. Epigenetic regulation has an essential influence on gene expression level. DNA...
-
ECG measurement from the hand with elbows in the air - Woman 27 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows in the air - Man 29 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows to the body - Man 29 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows to the body - Woman 27 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows to the body - Woman 49 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows in the air - Woman 49 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement in the bathtub - drl on the outside of the bathtub on one side- men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, drl behind the back - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement from the hand with elbows to the body - Man 53 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, sitting motionless - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement from the hand with elbows in the air - Woman 30 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, placed on the back - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement from the hand with elbows in the air - Man 53 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement in the bathtub - drl outside the bathtub on both sides- men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, bath simulation - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - sitting on measuring electrodes, drl in water - men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement from the hand with elbows in the air - Man 30 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows to the body - Man 30 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows to the body - Woman 24 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with elbows to the body - Woman 30 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement in the bathtub - drl in the bathtub, electrodes on the sides of the bathtub - men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement from the hand with elbows in the air - Woman 24 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
The conducted immunity test of a power supply unit in accordance with EMC standards
Open Research DataThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the DF1723003TC NDN power supply. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 150 kHz to 230 MHz are...
-
Modelowanie i symulacja zaburzeń przewodzonych z zastosowaniem programów Saber i TCad = Modeling and simulation of conducted emissions with TCad and Saber programs
PublicationPrzedstawiono symulacyjne badania porównawcze w zakresie kompatybilności elektromagnetycznej EMC modelu obwodowego przetwornicy DC-DC podwyższającej napięcie. Wskazano na specyfikę modelowania wynikającą z potrzeby przewidywania propagacji zaburzeń przewodzonych EMI w szerokim zakresie częstotliwości. Wyznaczono model układu dla symulatora Saber i porównano pomiary charakterystyki widma EMI z wynikami otrzymanymi z symulacji. Zbadano...
-
Robert Burczyk mgr inż.
PeopleRobert Burczyk received Eng. degree and M. SC. Eng. degree in electronics and telecommunictions engineering in 2017 and 2018 successively with specialization in radiocommunication systems and networks. The subject of the dissertations was focused on Wireless Body Area Network (WBAN). Currently, he is a PhD student and an employee at the Department of Radiocommunication Systems and Networks, Gdansk University of Technology. His...
-
Electrostatic Zipping Actuators—Analysis of the Pull-In Effect Depending on the Geometry Parameters
PublicationContinuous work on a new generation of actuators, referred to as artificial muscles, resulted in the initiation of work on electrostatic zipping actuators, the concept of which is derived from micro electro-mechanical devices. Despite partial knowledge of their basic operating parameters, a question remains whether electrostatic zipping actuators are able to meet the expectations in the context of generated forces and control possibilities....
-
Experimental economics in business education: Using simple games to achieve multifaceted effects
PublicationEconomics differs from other sciences not only because of its normative part, but also because of very limited use of experiments. In this way, economics is often perceived as being methodologically more similar to astronomy or meteorology rather than physics or chemistry. Over last decades, however, experimental economics has been significantly developed. This chapter presents some of the possibilities for academic teachers to...
-
Frequency bands selection of the Portevin-LeChatelier
PublicationEfekt Portevina-LeChateliera ujawnia się w postaci skokowych zmian naprężenia w trakcie procesu odkształcenia próbek pewnych stopów. Zjawisko PLC występuje w kilku odmianach charakteryzujących się istotnymi różnicami zarówno w przestrzennym rozkładzie pasm odkształcenia jak też przebiegu krzywej naprężeniowej. Przebiegi odpowiadające różnym odmianom serration charakteryzują się odmiennymi właściwościami rozkładu energetycznego...
-
Vision-based motion analysis of kitesurfer
PublicationKitesurfing is a relatively recent phenomenon with raising popularity worldwide – a recently developed extreme water sport considered a high-risk injury sport. It combines elements of several other sports, in particular sailing, surfing, windsurfing, wakeboarding, and snowboarding. The main purpose of authors’ research in the present paper is to use a vision system technique for measuring a kitesurfer’s body movements in order...
-
Wytrzymałość pętli wplatanych na linach podwójnie plecionych
PublicationCechą wyróżniającą statki żaglowe z grona innych obiektów pływających są żagle. To cecha widoczna, za którą kryją się mniej romantyczne elementy, takie jak maszty, liny i osprzęt. Rozpostarcie białych płócien na maszcie i następnie żeglowanie wymaga sprawnego operowania nimi, co wiąże się z doborem odpowiedniego ich zestawu, ułożenia i napięcia. To maszty są kręgosłupem takielunku, a liny jego mięśniami i ścięgnami. Do poprawnego...
-
Intensity Ratio of Kβ/Kα in Selected Elements from Mg to Cu, and the Chemical Effects of Cr Kα1,2 Diagram Lines and Cr Kβ/Kα Intensity Ratio in Cr Compounds
Publication -
Assessment of cardiovascular risk in assisted living
PublicationWady i choroby układu krążenia są jedną z podstawowych przyczyn problemów zdrowotnych oraz przyczyn śmierci. Wczesne ich wykrycie jest szczególnie cenne jako, że może zapobiec przez poważnymi incydentami (np. zawał, udar, itp.). W artykule przedstawiono nasobny system pomiarowy integrujący wiele pomiarów przydatnych do oceny problemów kardiologicznych.Disorders of the heart and blood vessels are the leading cause of health problems...
-
Natural Products Counteracting Cardiotoxicity during Cancer Chemotherapy: The Special Case of Doxorubicin, a Comprehensive Review
PublicationCardiotoxicity is a frequent undesirable phenomenon observed during oncological treatment that limits the therapeutic dose of antitumor drugs and thus may decrease the effec-‐‑ tiveness of cancer eradication. Almost all antitumor drugs exhibit toxic properties towards cardiac muscle. One of the underlying causes of cardiotoxicity is stimulation of oxidative...
-
Invasive breast carcinoma of no special type - Female, 55 - Tissue image [6130730026854851]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.