Filters
total: 20902
-
Catalog
- Publications 1700 available results
- Journals 32 available results
- People 55 available results
- Inventions 2 available results
- Projects 8 available results
- Laboratories 2 available results
- Research Equipment 5 available results
- e-Learning Courses 50 available results
- Events 13 available results
- Open Research Data 19035 available results
displaying 1000 best results Help
Search results for: GC-ECD
-
Optimization of Transport Properties of A-Site Ordered LnBa1-xSrxCo2-yFeyO5+ Perovskite-Type Cathode Materials
Publication -
Coking Study in Anode Materials for SOFCs: Physicochemical Properties and Behavior of Mo-Containing Perovskites in CO and CH4 Fuels
Publication -
Efficient and Economically Favorable Co-Free Air Electrodes for Solid Oxide Cells
Publication -
Evaluation of Praseodymium and Gadolinium Doped Ceria as a Possible Barrier Layer Material for Solid Oxide Cells
PublicationIn this work, nanocrystalline layers based on the Pr, Gd co-doped CeO2 were investigated. For the preparation of thin layers, lowtemperature spray pyrolysis technique was used. Different stoichiometries of the layers were produced for comparison on polished sapphire substrates. The microstructure of the prepared thin layers was studied by scanning electron microscopy (SEM), energydispersive X-ray spectroscopy (EDS) and X-ray diffractometry (XRD)....
-
The Influence of Iron Doping on Performance of SrTi1-XFexO3-δ Perovskite Oxygen Electrode for SOFC
PublicationSolid Oxide Fuel Cells (SOFC) are based on electrolytes and mixed ionic and electronic conductivity (MIEC) materials. The need to reduce costs causes an increase in interest of new compounds suitable for operating temperatures between 600 °C and 800 °C. The SrTi1-xFexO3 (STF) perovskite material is a perspective material that could be used for the oxygen electrodes. In this work STF materials with different content of iron (x =...
-
Materials for Mediator-free Electron Transfer in the Enzymatic Electrodes of Biobatteries and Biofuel Cells
PublicationWe present functionalization of single-walled carbon nanotubes (SWCNTs) and their application in the enzymatic fuel cells construction. SWCNTs were covalently modified with different types of aromatic moieties. Free radical reaction was employed to create direct carbon-carbon bond between moiety and SWCNTs. In second approach functionalization takes place through amide bonding. Functionalized SWCNTs were characterized by spectroscopy...
-
Development of gas chromatography - tandem mass spectrometry procedure for development of pesticide residues in honey and honeybee samples
PublicationA new analytical procedure of determination of multiresidue of pesticides based on application of the modified QuEChERS approach at the step of sample preparation and technique GC-MS/MS has been developed and applied for studies the real honey and honeybee samples. Samples were collected from northern Poland (Pomerania). The proposed procedure enables for the determination of 34 and 30 pesticides residues respectively on honey...
-
Some aspects of the analysis of environmental pollutants in sediments using pressurized liquid extraction and gas chromatography-mass spectrometry
PublicationOpisano wyniki badań nowej procedury oznaczania analitów z grupy wielopierścieniowych węglowodorów aromatycznych oraz polichlorowanych bifenyli w próbkach osadów dennych. Szczególnie dużo uwagi poświęcono zbadaniu możliwości wykorzystania techniki przyspieszonej ekstrakcji analitów za pomocą rozpuszczalnika na etapie izolacji wzbogacania. Ustalono również warunki oznaczeń końcowych z wykorzystaniem techniki GC-MS.
-
Analytical procedure for the determination of chlorobenzenes in sediments
PublicationW pracy przedstawiono badania nad opracowaniem procedury oznaczania chlorobenzenów w próbkach osadów dennych. Składa się ona z następujących etapów: ekstrakcji za pomocą rozpuszczalnika (wytrząsanie); oczyszczanie ekstraktu; odparowanie rozpuszczalnika (redukcja objętości ekstraktu); analiza z wykorzystaniem techniki GC-MS. Przeprowadzono badania stopnia odzysku z wykorzystaniem wzorca wewnętrznego (deuterowany 1,2-dibromobenzen).
-
Determination of volatile aliphatic amines in air by solid phase microex traction coupled with gas chromatography with flame ionization detection.
PublicationOpisano nową metodę oznaczania lotnych amin alifatycznych w powietrzu. Metodyka oparta jest na zastosowaniu techniki mikroekstrakcji do fazy stacjonarnej na etapie pobierania próbek oraz zestawu GC-FID do rozdzielania i oznaczania poszczególnych analitów.Badaniom poddano nowe typy faz stacjonarnych.Zbadano wpływ wilgotności powietrza na proces pobierania próbek analitów z powietrza.
-
Novel fast analytical method for indirect determination of MCPD fatty acid esters in edible oils and fats based on simultaneous extraction and derivatization
PublicationA novel method for indirect determination of MCPD esters levels in lipid samples has been developed. The method is based on combination of extraction and derivatisation in the same sample preparation step. It is achieved by the application of diethyl ether as extraction solvent for isolation of released from esterified forms analytes from water phase and dilution solvent for solid PBA – derivatisation agent. It is a noteworthy...
-
Dispersive liquid-liquid microextraction combined with gas chromatography–mass spectrometry for in situ determination of biogenic amines in meat: Estimation of meat's freshness
PublicationA dispersive liquid-liquid microextraction (DLLME) gas chromatography–mass spectrometry (GC–MS) technique was developed for the determination of selected biogenic amines (BAs) in samples of poultry, pork and beef. Prior to the extraction process, an appropriate volume of sodium hydroxide solution was added to each of the portioned samples. Next, samples were homogenized, centrifuged and finally sonicated at an increased temperature....
-
Demulgowanie jako efektywna technika rozdzielania stosowana w procesach oczyszczania ścieków przemysłowych
PublicationOczyszczanie ścieków przemysłowych ma na celu, z reguły kilku-etapową, redukcję ładunku zanieczyszczeń na drodze procesów fizycznych, chemicznych i biologicznych. W przypadku odprowadzania strumienia ścieków poza zakład, parametry ścieków muszą spełniać normy określające dopuszczalny poziom zanieczyszczeń organicznych i nieorganicznych w ściekach. Duże znaczenie w bilansie ekonomicznym oczyszczania ścieków ma dobór procesów wstępnego...
-
Comparison of the Physical and Sensory Properties of Hybrid Citrus Fruit Jaffa® Sweetie in Relation to the Parent Fruits
PublicationIn the presented study, an overall Jaffa sweetie evaluation was made to find a correlation between Citrus grandis Osbeck × Citrus paradisi Macf. and its parent fruits’ (Citrus grandis Osbeck, Citrus paradisi Macf.) properties. Based on the sensory analysis, it was found that the taste and aroma of the new hybrid fruit are close to pummelo. By the use of chromatographic analysis, the selected monoterpenes present in the fruits were...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Man 29 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Woman 27 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Woman 28 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 28 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Man 29 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Woman 28 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Man 29 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Woman 27 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 27 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 30 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Man 30 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Woman 30 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Woman 24 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the buttocks, drills at the feet, grounding the bathtub - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Woman 24 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
ECG measurement in the bathtub - drl on one side of the bath mass on the other - the person is moving- men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Man 53 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Man 53 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Woman 24 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
ECG measurement in the bathtub - conversation during measurement, electrodes on the sides of the bathtub, drl in water - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
PULSE and ECG measurement from the hand with elbows resting on the table top - Man 53 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Man 30 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows resting on the armrests of the chair - Man 30 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Woman 30 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
Podstawy użytkowania systemu EZD
e-Learning Courses -
Eco-design of cities and regions
e-Learning Courses -
Development of a vortex-assisted switchable-hydrophilicity solvent-based liquid phase microextraction for fast and reliable extraction of Zn (II), Fe (II), Pb (II), and Cd (II) from various baby food products
PublicationThis manuscript describes the development of a novel liquid phase microextraction (LPME) method for the extraction and determination of Zn (II), Fe (II), Pb (II), and Cd (II) in various infant/baby food and supplements products. The method is based on vortex-assisted extraction combined with a switchable-hydrophilicity solvent (SHS) sample preparation. The SHS, which undergoes reversible phase changes triggered by pH change, enables...
-
In-situ generation of Ag, Cd, Hg, In, Pb, Tl and Zn volatile species by flowing liquid anode atmospheric pressure glow discharge operated in gaseous jet mode – Evaluation of excitation processes and analytical performance
Publication -
Solid-contact lead(II) ion-selective electrodes for potentiometric determination of lead(II) in presence of high concentrations of Na(I), Cu(II), Cd(II), Zn(II), Ca(II) and Mg(II)
PublicationLead and its compounds are a serious threat to the environment. Monitoring of this toxic heavy metal is a driving force for the continuous development of novel lead(II) ionophores to be applied in ion-selective electrodes. In this work a highly selective lead(II) ionophore, namely 25,26,27,28-tetrakis(piperidinylthiocarbonylmethylene)-p-tert-butylcalix[4]arene, was used in solid-contact ion-selective electrodes for determination...
-
- -
ProjectsProject realized in Faculty of Chemistry according to Ventures/2009-3/3 agreement from 2009-08-06
-
Niebezpieczeństwo ukryte w żywności-aminy biogenne. Cz. II. Metody oznaczania i wyzwania.
PublicationZe względu na aktywność biologiczną amin biogennych ich oznaczanie zarówno jakościowe, jak i ilościowe w żywności ma istotne znaczenie w celu zapewnienia ochrony zdrowia i życia ludzkiego. Obecnie do monitoringu amin biogennych w żywności najczęściej wykorzystuje się: wysokosprawną chromatografię cieczową (HPLC), chromatografię cienkowarstwową (TLC) oraz absorpcyjną spektrofotometrię cząsteczkową. Są to jednak techniki czasochłonne,...
-
Studies on applicability of new solid-phase microextraction and determination of short - chain monocarboxylic acids
PublicationA convenient approach to monitor the short-chain monocaroboksylic acids (SCAMs) in different samples is gas chromatography (GC) preceded by sample preparation based on solid-phase microextraction (SPME). The fiber with polar coatings were used to extract the SCAMs from headspace of liquid and solid samples. Recently polimeric ionic liquid (PIL) fiber coatings have been proposed to extract volatile organic compounds, minly polar...
-
Preliminary studies comparing the chemical composition of goitschiteand Saxonian succinite = Wstępne badania dotyczące porównania chemicznego składu goitszytu i sukcynitu saksońskiego
PublicationChemiczny skład goitszytu i sukcynitu saksońskiego porównano metodą spektroskopową (FTIR). Dalsza analiza została przeprowadzona z ekstraktów niepolarnych za pomocą chromatografii gazowej sprzężonej ze spektrometrią mas (GC-MS). Potwierdzono podobieństwo składu chemicznego bursztynu bitterfeldzkiego i sukcynitu z regionu Morza Bałtyckiego. Substancje zidentyfikowane w ekstrakcie goitszytu mogą sugerować jego genetyczne podobieństwo...
-
Geometrically nonlinear FEM analysis of 6-parameter resultant shell theory based on 2-D Cosserat constitutive model
PublicationWe develop the elastic constitutive law for the resultant statically and kinematically exact, nonlinear, 6-parameter shell theory. The Cosserat plane stress equations are integrated through-the- thickness under assumption of the Reissner-Mindlin kinematics. The resulting constitutive equations for stress resultant and couple resultants are expressed in terms of two micropolar constants: the micropolar modulus Gc and the micropolar...
-
Andreas Hoff (ed.) (2011). Population Ageing in Central and Eastern Europe. Societal and Policy Implications. Farnham, UK & Burlington, VT, USA: Ashgate, 260 pp. ISBN 978 0 7546 7828 1 (hardback)
Publication -
Maciej Niedostatkiewicz dr hab. inż.
People